Skip to main content

Showing 1–4 of 4 results for author: Martin, Y

Searching in archive nucl-ex. Search in all archives.
.
  1. arXiv:2107.06007  [pdf, other

    physics.ins-det hep-ex nucl-ex

    The EXO-200 detector, part II: Auxiliary Systems

    Authors: N. Ackerman, J. Albert, M. Auger, D. J. Auty, I. Badhrees, P. S. Barbeau, L. Bartoszek, E. Baussan, V. Belov, C. Benitez-Medina, T. Bhatta, M. Breidenbach, T. Brunner, G. F. Cao, W. R. Cen, C. Chambers, B. Cleveland, R. Conley, S. Cook, M. Coon, W. Craddock, A. Craycraft, W. Cree, T. Daniels, L. Darroch , et al. (135 additional authors not shown)

    Abstract: The EXO-200 experiment searched for neutrinoless double-beta decay of $^{136}$Xe with a single-phase liquid xenon detector. It used an active mass of 110 kg of 80.6%-enriched liquid xenon in an ultra-low background time projection chamber with ionization and scintillation detection and readout. This paper describes the design and performance of the various support systems necessary for detector op… ▽ More

    Submitted 22 October, 2021; v1 submitted 13 July, 2021; originally announced July 2021.

    Comments: Manuscript updated in response to JINST reviewer comments

  2. arXiv:1108.4193  [pdf, ps, other

    nucl-ex hep-ex physics.ins-det

    Observation of Two-Neutrino Double-Beta Decay in Xe-136 with EXO-200

    Authors: N. Ackerman, B. Aharmim, M. Auger, D. J. Auty, P. S. Barbeau, K. Barry, L. Bartoszek, E. Beauchamp, V. Belov, C. Benitez-Medina, M. Breidenbach, A. Burenkov, B. Cleveland, R. Conley, E. Conti, J. Cook, S. Cook, A. Coppens, I. Counts, W. Craddock, T. Daniels, M. V. Danilov, C. G. Davis, J. Davis, R. deVoe , et al. (78 additional authors not shown)

    Abstract: We report the observation of two-neutrino double-beta decay in Xe-136 with T_1/2 = 2.11 +- 0.04 (stat.) +- 0.21 (sys.) x 10^21 yr. This second order process, predicted by the Standard Model, has been observed for several nuclei but not for Xe-136. The observed decay rate provides new input to matrix element calculations and to the search for the more interesting neutrino-less double-beta decay, th… ▽ More

    Submitted 22 November, 2011; v1 submitted 21 August, 2011; originally announced August 2011.

  3. arXiv:physics/0702122  [pdf, ps, other

    physics.atom-ph nucl-ex

    Observation of single collisionally cooled trapped ions in a buffer gas

    Authors: M. Green, J. Wodin, R. DeVoe, P. Fierlinger, B. Flatt, G. Gratta, F. LePort, M. Montero Diez, R. Neilson, K. OSullivan, A. Pocar, S. Waldman, D. S. Leonard, A. Piepke, C. Hargrove, D. Sinclair, V. Strickland, W. Fairbank Jr., K. Hall, B. Mong, M. Moe, J. Farine, D. Hallman, C. Virtue, E. Baussan , et al. (15 additional authors not shown)

    Abstract: Individual Ba ions are trapped in a gas-filled linear ion trap and observed with a high signal-to-noise ratio by resonance fluorescence. Single-ion storage times of ~5 min (~1 min) are achieved using He (Ar) as a buffer gas at pressures in the range 8e-5 - 4e-3 torr. Trap dynamics in buffer gases are experimentally studied in the simple case of single ions. In particular, the cooling effects of… ▽ More

    Submitted 5 July, 2007; v1 submitted 14 February, 2007; originally announced February 2007.

    Comments: 5 pages, 4 figures, accepted for publication in Phys. Rev. A. Minor text and figure changes

  4. arXiv:physics/0611183  [pdf, ps, other

    physics.ins-det nucl-ex

    A liquid xenon ionization chamber in an all-fluoropolymer vessel

    Authors: EXO Collaboration, F. LePort, A. Pocar, L. Bartoszek, R. DeVoe, P. Fierlinger, B. Flatt, G. Gratta, M. Green, T. Koffas, M. Montero Diez, R. Neilson, K. O'Sullivan, S. Waldman, J. Wodin, D. Woisard, E. Baussan, M. Breidenbach, R. Conley, W. Fairbank Jr., J. Farine, C. Hall, K. Hall, D. Hallman, C. Hargrove , et al. (20 additional authors not shown)

    Abstract: A novel technique has been developed to build vessels for liquid xenon ionization detectors entirely out of ultra-clean fluoropolymer. We describe the advantages in terms of low radioactivity contamination, provide some details of the construction techniques, and show the energy resolution achieved with a prototype all-fluoropolymer ionization detector.

    Submitted 19 November, 2006; originally announced November 2006.

    Comments: 12 pages, 9 figures

    Journal ref: Nucl.Instrum.Meth.A578:409-420,2007