Strange Hadron Spectroscopy with Secondary KL Beam in Hall D
Authors:
KLF Collaboration,
Moskov Amaryan,
Mikhail Bashkanov,
Sean Dobbs,
James Ritman,
Justin Stevens,
Igor Strakovsky,
Shankar Adhikari,
Arshak Asaturyan,
Alexander Austregesilo,
Marouen Baalouch,
Vitaly Baturin,
Vladimir Berdnikov,
Olga Cortes Becerra,
Timothy Black,
Werner Boeglin,
William Briscoe,
William Brooks,
Volker Burkert,
Eugene Chudakov,
Geraint Clash,
Philip Cole,
Volker Crede,
Donal Day,
Pavel Degtyarenko
, et al. (128 additional authors not shown)
Abstract:
We propose to create a secondary beam of neutral kaons in Hall D at Jefferson Lab to be used with the GlueX experimental setup for strange hadron spectroscopy. The superior CEBAF electron beam will enable a flux on the order of $1\times 10^4~K_L/sec$, which exceeds the flux of that previously attained at SLAC by three orders of magnitude. The use of a deuteron target will provide first measurement…
▽ More
We propose to create a secondary beam of neutral kaons in Hall D at Jefferson Lab to be used with the GlueX experimental setup for strange hadron spectroscopy. The superior CEBAF electron beam will enable a flux on the order of $1\times 10^4~K_L/sec$, which exceeds the flux of that previously attained at SLAC by three orders of magnitude. The use of a deuteron target will provide first measurements ever with neutral kaons on neutrons. The experiment will measure both differential cross sections and self-analyzed polarizations of the produced $Λ$, $Σ$, $Ξ$, and $Ω$ hyperons using the GlueX detector at the Jefferson Lab Hall D. The measurements will span CM $\cosθ$ from $-0.95$ to 0.95 in the range W = 1490 MeV to 2500 MeV. The new data will significantly constrain the partial wave analyses and reduce model-dependent uncertainties in the extraction of the properties and pole positions of the strange hyperon resonances, and establish the orbitally excited multiplets in the spectra of the $Ξ$ and $Ω$ hyperons. Comparison with the corresponding multiplets in the spectra of the charm and bottom hyperons will provide insight into he accuracy of QCD-based calculations over a large range of masses. The proposed facility will have a defining impact in the strange meson sector through measurements of the final state $Kπ$ system up to 2 GeV invariant mass. This will allow the determination of pole positions and widths of all relevant $K^\ast(Kπ)$ $S$-,$P$-,$D$-,$F$-, and $G$-wave resonances, settle the question of the existence or nonexistence of scalar meson $κ/K_0^\ast(700)$ and improve the constrains on their pole parameters. Subsequently improving our knowledge of the low-lying scalar nonet in general.
△ Less
Submitted 4 March, 2021; v1 submitted 18 August, 2020;
originally announced August 2020.
-
Conceptual Design of Beryllium Target for the KLF Project
Authors:
Igor Strakovsky,
Moskov Amaryan,
Mikhail Bashkanov,
William J. Briscoe,
Eugene Chudakov,
Pavel Degtyarenko,
Sean Dobbs,
Alexander Laptev,
Ilya Larin,
Alexander Somov,
Timothy Whitlatch
Abstract:
The Kaon Production Target (KPT) is an important component of the proposed K-Long facility which will be operated in JLab Hall~D, targeting strange baryon and meson spectroscopy. In this note we present a conceptual design for the Be-target assembly for the planned K-Long beam line, which will be used along with the GlueX spectrometer in its standard configuration for the proposed experiments. The…
▽ More
The Kaon Production Target (KPT) is an important component of the proposed K-Long facility which will be operated in JLab Hall~D, targeting strange baryon and meson spectroscopy. In this note we present a conceptual design for the Be-target assembly for the planned K-Long beam line, which will be used along with the GlueX spectrometer in its standard configuration for the proposed experiments. The high quality 12-GeV CEBAF electron beam enables production of a K$_L$ flux at the GlueX target on the order of $1\times 10^4 K_L/sec$, which exceeds the K$_L$ flux previously attained at SLAC by three orders of magnitude. An intense K$_L$ beam would open a new window of opportunity not only to locate "missing resonances" in the strange hadron spectrum, but also to establish their properties by studying different decay channels systematically. The most important and radiation damaging background in K$_L$ production is due to neutrons. The Monte Carlo simulations for the proposed conceptual design of KPT show that the resulting neutron and gamma flux lead to a prompt radiation dose rate for the KLF experiment that is below the JLab Radiation Control Department radiation dose rate limits in the experimental hall and at the site boundary, and will not substantially affect the performance of the spectrometer.
△ Less
Submitted 10 February, 2020;
originally announced February 2020.
-
Measurement of the normalized $^{238}$U(n,f)/$^{235}$U(n,f) cross section ratio from threshold to 30 MeV with the fission Time Projection Chamber
Authors:
R. J. Casperson,
D. M. Asner,
J. Baker,
R. G. Baker,
J. S. Barrett,
N. S. Bowden,
C. Brune,
J. Bundgaard,
E. Burgett,
D. A. Cebra,
T. Classen,
M. Cunningham,
J. Deaven,
D. L. Duke,
I. Ferguson,
J. Gearhart,
V. Geppert-Kleinrath,
U. Greife,
S. Grimes,
E. Guardincerri,
U. Hager,
C. Hagmann,
M. Heffner,
D. Hensle,
N. Hertel
, et al. (39 additional authors not shown)
Abstract:
The normalized $^{238}$U(n,f)/$^{235}$U(n,f) cross section ratio has been measured using the NIFFTE fission Time Projection Chamber from the reaction threshold to $30$~MeV. The fissionTPC is a two-volume MICROMEGAS time projection chamber that allows for full three-dimensional reconstruction of fission-fragment ionization profiles from neutron-induced fission. The measurement was performed at the…
▽ More
The normalized $^{238}$U(n,f)/$^{235}$U(n,f) cross section ratio has been measured using the NIFFTE fission Time Projection Chamber from the reaction threshold to $30$~MeV. The fissionTPC is a two-volume MICROMEGAS time projection chamber that allows for full three-dimensional reconstruction of fission-fragment ionization profiles from neutron-induced fission. The measurement was performed at the Los Alamos Neutron Science Center, where the neutron energy is determined from neutron time-of-flight. The $^{238}$U(n,f)/$^{235}$U(n,f) ratio reported here is the first cross section measurement made with the fissionTPC, and will provide new experimental data for evaluation of the $^{238}$U(n,f) cross section, an important standard used in neutron-flux measurements. Use of a development target in this work prevented the determination of an absolute normalization, to be addressed in future measurements. Instead, the measured cross section ratio has been normalized to ENDF/B-VIII.$β$5 at 14.5 MeV.
△ Less
Submitted 23 February, 2018;
originally announced February 2018.
-
Precision determination of absolute neutron flux
Authors:
A. T. Yue,
E. S. Anderson,
M. S. Dewey,
D. M. Gilliam,
G. L. Greene,
A. B. Laptev,
J. S. Nico,
W. M. Snow
Abstract:
A technique for establishing the total neutron rate of a highly-collimated monochromatic cold neutron beam was demonstrated using a method of an alpha-gamma counter. The method involves only the counting of measured rates and is independent of neutron cross sections, decay chain branching ratios, and neutron beam energy. For the measurement, a target of 10B-enriched boron carbide totally absorbed…
▽ More
A technique for establishing the total neutron rate of a highly-collimated monochromatic cold neutron beam was demonstrated using a method of an alpha-gamma counter. The method involves only the counting of measured rates and is independent of neutron cross sections, decay chain branching ratios, and neutron beam energy. For the measurement, a target of 10B-enriched boron carbide totally absorbed the neutrons in a monochromatic beam, and the rate of absorbed neutrons was determined by counting 478keV gamma rays from neutron capture on 10B with calibrated high-purity germanium detectors. A second measurement based on Bragg diffraction from a perfect silicon crystal was performed to determine the mean de Broglie wavelength of the beam to a precision of 0.024 %. With these measurements, the detection efficiency of a neutron monitor based on neutron absorption on 6Li was determined to an overall uncertainty of 0.058 %. We discuss the principle of the alpha-gamma method and present details of how the measurement was performed including the systematic effects. We also describe how this method may be used for applications in neutron dosimetry and metrology, fundamental neutron physics, and neutron cross section measurements.
△ Less
Submitted 8 January, 2018;
originally announced January 2018.
-
aCORN: an experiment to measure the electron-antineutrino correlation coefficient in free neutron decay
Authors:
B. Collett,
F. Bateman,
W. K. Bauder,
J. Byrne,
W. A. Byron,
W. Chen,
G. Darius,
C. DeAngelis,
M. S. Dewey,
T. R. Gentile,
M. T. Hassan,
G. L. Jones,
A. Komives,
A. Laptev,
M. P. Mendenhall,
J. S. Nico,
G. Noid,
H. Park,
E. J. Stephenson,
I. Stern,
K. J. S. Stockton,
C. Trull,
F. E. Wietfeldt,
B. G. Yerozolimsky
Abstract:
We describe an apparatus used to measure the electron-antineutrino angular correlation coefficient in free neutron decay. The apparatus employs a novel measurement technique in which the angular correlation is converted into a proton time-of-flight asymmetry that is counted directly, avoiding the need for proton spectroscopy. Details of the method, apparatus, detectors, data acquisition, and data…
▽ More
We describe an apparatus used to measure the electron-antineutrino angular correlation coefficient in free neutron decay. The apparatus employs a novel measurement technique in which the angular correlation is converted into a proton time-of-flight asymmetry that is counted directly, avoiding the need for proton spectroscopy. Details of the method, apparatus, detectors, data acquisition, and data reduction scheme are presented, along with a discussion of the important systematic effects.
△ Less
Submitted 21 February, 2017; v1 submitted 17 January, 2017;
originally announced January 2017.
-
A Time Projection Chamber for High Accuracy and Precision Fission Cross Section Measurements
Authors:
NIFFTE Collaboration,
M. Heffner,
D. M. Asner,
R. G. Baker,
J. Baker,
S. Barrett,
C. Brune,
J. Bundgaard,
E. Burgett,
D. Carter,
M. Cunningham,
J. Deaven,
D. L. Duke,
U. Greife,
S. Grimes,
U. Hager,
N. Hertel,
T. Hill,
D. Isenhower,
K. Jewell,
J. King,
J. L. Klay,
V. Kleinrath,
N. Kornilov,
R. Kudo
, et al. (25 additional authors not shown)
Abstract:
The fission Time Projection Chamber (fissionTPC) is a compact (15 cm diameter) two-chamber MICROMEGAS TPC designed to make precision cross section measurements of neutron-induced fission. The actinide targets are placed on the central cathode and irradiated with a neutron beam that passes axially through the TPC inducing fission in the target. The 4$π$ acceptance for fission fragments and complete…
▽ More
The fission Time Projection Chamber (fissionTPC) is a compact (15 cm diameter) two-chamber MICROMEGAS TPC designed to make precision cross section measurements of neutron-induced fission. The actinide targets are placed on the central cathode and irradiated with a neutron beam that passes axially through the TPC inducing fission in the target. The 4$π$ acceptance for fission fragments and complete charged particle track reconstruction are powerful features of the fissionTPC which will be used to measure fission cross sections and examine the associated systematic errors. This paper provides a detailed description of the design requirements, the design solutions, and the initial performance of the fissionTPC.
△ Less
Submitted 26 March, 2014;
originally announced March 2014.
-
Development of position-sensitive time-of-flight spectrometer for fission fragment research
Authors:
C. W. Arnold,
F. Tovesson,
K. Meierbachtol,
T. Bredeweg,
M. Jandel,
H. J. Jorgenson,
A. Laptev,
G. Rusev,
D. W. Shields,
M. White,
R. E. Blakeley,
D. M. Mader,
A. A. Hecht
Abstract:
A position-sensitive, high-resolution time-of-flight detector for fission fragments has been developed. The SPectrometer for Ion DEterminiation in fission Research (SPIDER) is a $2E-2v$ spectrometer designed to measure the mass of light fission fragments to a single mass unit. The time pick-off detector pairs to be used in SPIDER have been tested with $α$-particles from $^{229}$Th and its decay ch…
▽ More
A position-sensitive, high-resolution time-of-flight detector for fission fragments has been developed. The SPectrometer for Ion DEterminiation in fission Research (SPIDER) is a $2E-2v$ spectrometer designed to measure the mass of light fission fragments to a single mass unit. The time pick-off detector pairs to be used in SPIDER have been tested with $α$-particles from $^{229}$Th and its decay chain and $α$-particles and spontaneous fission fragments from $^{252}$Cf. Each detector module is comprised of a thin electron conversion foil, electrostatic mirror, microchannel plates, and delay-line anodes. Particle trajectories on the order of 700 mm are determined accurately to within 0.7 mm. Flight times on the order of 70 ns were measured with 200 ps resolution FWHM. Computed particle velocities are accurate to within 0.06 mm/ns corresponding to precision of 0.5%. An ionization chamber capable of 400 keV energy resolution coupled with the velocity measurements described here will pave the way for modestly efficient measurements of light fission fragments with unit mass resolution.
△ Less
Submitted 6 March, 2014;
originally announced March 2014.
-
Improved Determination of the Neutron Lifetime
Authors:
A. T. Yue,
M. S. Dewey,
D. M. Gilliam,
G. L. Greene,
A. B. Laptev,
J. S. Nico,
W. M. Snow,
F. E. Wietfeldt
Abstract:
The most precise determination of the neutron lifetime using the beam method was completed in 2005 and reported a result of $τ_n = (886.3 \pm 1.2 [\textrm{stat}] \pm 3.2 [\textrm{syst}])$ s. The dominant uncertainties were attributed to the absolute determination of the fluence of the neutron beam (2.7 s). The fluence was measured with a neutron monitor that counted the neutron-induced charged par…
▽ More
The most precise determination of the neutron lifetime using the beam method was completed in 2005 and reported a result of $τ_n = (886.3 \pm 1.2 [\textrm{stat}] \pm 3.2 [\textrm{syst}])$ s. The dominant uncertainties were attributed to the absolute determination of the fluence of the neutron beam (2.7 s). The fluence was measured with a neutron monitor that counted the neutron-induced charged particles from absorption in a thin, well-characterized 6Li deposit. The detection efficiency of the monitor was calculated from the areal density of the deposit, the detector solid angle, and the evaluated nuclear data file, ENDF/B-VI 6Li(n,t)4He thermal neutron cross section. In the current work, we have measured the detection efficiency of the same monitor used in the neutron lifetime measurement with a second, totally-absorbing neutron detector. This direct approach does not rely on the 6Li(n,t)4He cross section or any other nuclear data. The detection efficiency is consistent with the value used in 2005 but was measured with a precision of 0.057 %, which represents a five-fold improvement in the uncertainty. We have verified the temporal stability of the neutron monitor through ancillary measurements, allowing us to apply the measured neutron monitor efficiency to the lifetime result from the 2005 experiment. The updated lifetime is $τ_n = (887.7 \pm 1.2 [\textrm{stat}] \pm 1.9 [\textrm{syst}])$ s.
△ Less
Submitted 27 November, 2013; v1 submitted 10 September, 2013;
originally announced September 2013.
-
Targets for Precision Measurements
Authors:
W. Loveland,
L. Yao,
David M. Asner,
R. G. Baker,
J. Bundgaard,
E. Burgett,
M. Cunningham,
J. Deaven,
D. L. Duke,
U. Greife,
S. Grimes,
M. Heffer,
T. Hill,
D. Isenhower,
J. L. Klay,
V. Kleinrath,
N. Kornilov,
A. B. Laptev,
T. N. Massey,
R. Meharchand,
H. Qu,
J. Ruz,
S. Sangiorgio,
B. Selhan,
L. Snyder
, et al. (9 additional authors not shown)
Abstract:
The general properties needed in targets (sources) for high precision, high accuracy measurements are reviewed. The application of these principles to the problem of develo** targets for the Fission TPC is described. Longer term issues, such as the availability of actinide materials, improved knowledge of energy losses and straggling and the stability of targets during irradiation are also discu…
▽ More
The general properties needed in targets (sources) for high precision, high accuracy measurements are reviewed. The application of these principles to the problem of develo** targets for the Fission TPC is described. Longer term issues, such as the availability of actinide materials, improved knowledge of energy losses and straggling and the stability of targets during irradiation are also discussed.
△ Less
Submitted 9 March, 2013;
originally announced March 2013.
-
Absolute Total np and pp Cross Section Determinations
Authors:
R. A. Arndt,
W. J. Briscoe,
A. B. Laptev,
I. I. Strakovsky,
R. L. Workman
Abstract:
Absolute total cross sections for np and pp scattering below 1000 MeV are determined based on partial-wave analyses of NN scattering data. These cross sections are compared with most recent ENDF/B and JENDL data files, and the Nijmegen partial-wave analysis. Systematic deviations from the ENDF/B and JENDL evaluations are found to exist in the low-energy region.
Absolute total cross sections for np and pp scattering below 1000 MeV are determined based on partial-wave analyses of NN scattering data. These cross sections are compared with most recent ENDF/B and JENDL data files, and the Nijmegen partial-wave analysis. Systematic deviations from the ENDF/B and JENDL evaluations are found to exist in the low-energy region.
△ Less
Submitted 5 January, 2009; v1 submitted 6 June, 2008;
originally announced June 2008.