-
Obtaining high resolution excitation functions with an active thick-target approach and validating them with mirror nuclei
Authors:
S. Hudan,
J. E. Johnstone,
Rohit Kumar,
R. T. deSouza,
J. Allen,
D. W. Bardayan,
D. Blankstein,
C. Boomershine,
S. Carmichael,
A. Clark,
S. Coil,
S. L. Henderson,
P. D. O'Malley,
W. W. von Seeger
Abstract:
Measurement of fusion excitation functions for stable nuclei has largely been restricted to nuclei with significant natural abundance. Typically, to investigate neighboring nuclei with low natural abundance has required obtaining isotopically enriched material. This restriction often limits the ability to perform such measurements. We report the measurement of a high quality fusion excitation func…
▽ More
Measurement of fusion excitation functions for stable nuclei has largely been restricted to nuclei with significant natural abundance. Typically, to investigate neighboring nuclei with low natural abundance has required obtaining isotopically enriched material. This restriction often limits the ability to perform such measurements. We report the measurement of a high quality fusion excitation function for a $^{17}$O beam produced from unenriched material with 0.038\% natural abundance. The measurement is enabled by using an active thick-target approach and the accuracy of the result is validated using its mirror nucleus $^{17}$F and resonances. The result provides important information about the average fusion cross-section for the oxygen isotopic chain as a function of neutron excess.
△ Less
Submitted 18 April, 2023;
originally announced April 2023.
-
Proton and neutron exchange as a prelude to fusion at near-barrier energies
Authors:
J. E. Johnstone,
Varinderjit Singh,
R. Giri,
S. Hudan,
J. Vadas,
R. T. deSouza,
D. Ackermann,
A. Chbihi,
Q. Hourdille,
A. Abbott,
C. Balhoff,
A. Hannaman,
A. B. McIntosh,
M. Sorensen,
Z. Tobin,
A. Wakhle,
S. J. Yennello,
M. A. Famiano,
K. W. Brown,
C. Santamaria,
J. Lubian,
H. O. Soler,
B. V. Carlson
Abstract:
Systematic examination of fusion for $^{39,41,45,47}$K + $^{28}$Si and $^{36,44}$Ar + $^{28}$Si provides insight into the impact of neutron and proton exchange on fusion for nuclei at and near the N=20 and N=28 shells. Comparison of the reduced excitation functions reveals a marked difference between the behavior of open-shell and closed-shell systems. While coupled channels calculations provide a…
▽ More
Systematic examination of fusion for $^{39,41,45,47}$K + $^{28}$Si and $^{36,44}$Ar + $^{28}$Si provides insight into the impact of neutron and proton exchange on fusion for nuclei at and near the N=20 and N=28 shells. Comparison of the reduced excitation functions reveals a marked difference between the behavior of open-shell and closed-shell systems. While coupled channels calculations provide a good description for the closed-shell nuclei they significantly under-predict the fusion cross-section for open-shell nuclei. The observed trends are examined in the context of a potential energy surface, including shell effects, and multi-nucleon exchange with consideration of Pauli-blocking.
△ Less
Submitted 13 June, 2022;
originally announced June 2022.
-
MuSIC@Indiana: an effective tool for accurate measurement of fusion with low-intensity radioactive beams
Authors:
J. E. Johnstone,
Rohit Kumar,
S. Hudan,
Varinderjit Singh,
R. T. deSouza,
J. Allen,
D. W. Bardayan,
D. Blankstein,
C. Boomershine,
S. Carmichael,
A. M. Clark,
S. Coil,
S. L. Henderson,
P. D. O'Malley
Abstract:
The design, construction, and characterization of the Multi-Sampling Ionization Chamber, MuSIC@Indiana, are described. This detector provides efficient and accurate measurement of the fusion cross-section at near-barrier energies. The response of the detector to low-intensity beams of $^{17,18}$O, $^{19}$F, $^{23}$Na, $^{24,26}$Mg, $^{27}$Al, and $^{28}$Si at E$_{lab}$ = 50-60 MeV was examined. Mu…
▽ More
The design, construction, and characterization of the Multi-Sampling Ionization Chamber, MuSIC@Indiana, are described. This detector provides efficient and accurate measurement of the fusion cross-section at near-barrier energies. The response of the detector to low-intensity beams of $^{17,18}$O, $^{19}$F, $^{23}$Na, $^{24,26}$Mg, $^{27}$Al, and $^{28}$Si at E$_{lab}$ = 50-60 MeV was examined. MuSIC@Indiana was commissioned by measuring the $^{18}$O+$^{12}$C fusion excitation function for 11 $<$ E$_{cm}$ $<$ 20 MeV using CH$_{4}$ gas. A simple, effective analysis cleanly distinguishes proton capture and two-body scattering events from fusion on carbon. With MuSIC@Indiana, measurement of 15 points on the excitation function for a single incident beam energy is achieved. The resulting excitation function is shown to be in good agreement with literature data
△ Less
Submitted 12 July, 2021;
originally announced July 2021.
-
Measurement of the Positive Muon Anomalous Magnetic Moment to 0.46 ppm
Authors:
B. Abi,
T. Albahri,
S. Al-Kilani,
D. Allspach,
L. P. Alonzi,
A. Anastasi,
A. Anisenkov,
F. Azfar,
K. Badgley,
S. Baeßler,
I. Bailey,
V. A. Baranov,
E. Barlas-Yucel,
T. Barrett,
E. Barzi,
A. Basti,
F. Bedeschi,
A. Behnke,
M. Berz,
M. Bhattacharya,
H. P. Binney,
R. Bjorkquist,
P. Bloom,
J. Bono,
E. Bottalico
, et al. (212 additional authors not shown)
Abstract:
We present the first results of the Fermilab Muon g-2 Experiment for the positive muon magnetic anomaly $a_μ\equiv (g_μ-2)/2$. The anomaly is determined from the precision measurements of two angular frequencies. Intensity variation of high-energy positrons from muon decays directly encodes the difference frequency $ω_a$ between the spin-precession and cyclotron frequencies for polarized muons in…
▽ More
We present the first results of the Fermilab Muon g-2 Experiment for the positive muon magnetic anomaly $a_μ\equiv (g_μ-2)/2$. The anomaly is determined from the precision measurements of two angular frequencies. Intensity variation of high-energy positrons from muon decays directly encodes the difference frequency $ω_a$ between the spin-precession and cyclotron frequencies for polarized muons in a magnetic storage ring. The storage ring magnetic field is measured using nuclear magnetic resonance probes calibrated in terms of the equivalent proton spin precession frequency ${\tildeω'^{}_p}$ in a spherical water sample at 34.7$^{\circ}$C. The ratio $ω_a / {\tildeω'^{}_p}$, together with known fundamental constants, determines $a_μ({\rm FNAL}) = 116\,592\,040(54)\times 10^{-11}$ (0.46\,ppm). The result is 3.3 standard deviations greater than the standard model prediction and is in excellent agreement with the previous Brookhaven National Laboratory (BNL) E821 measurement. After combination with previous measurements of both $μ^+$ and $μ^-$, the new experimental average of $a_μ({\rm Exp}) = 116\,592\,061(41)\times 10^{-11}$ (0.35\,ppm) increases the tension between experiment and theory to 4.2 standard deviations
△ Less
Submitted 7 April, 2021;
originally announced April 2021.
-
The BGOOD experimental setup at ELSA
Authors:
S. Alef,
P. Bauer,
D. Bayadilov,
R. Beck,
M. Becker,
A. Bella,
J. Bieling,
S. Boese,
A. Braghieri,
K. -Th. Brinkmann,
P. Cole,
R. Di Salvo,
D. Elsner,
A. Fantini,
O. Freyermuth,
F. Frommberger,
G. Gervino,
F. Ghio,
S. Goertz,
A. Gridnev,
E. Gutz,
D. Hammann,
J. Hannappel,
W. Hillert,
O. Jahn
, et al. (36 additional authors not shown)
Abstract:
The BGOOD experiment at the ELSA facility in Bonn has been commissioned within the framework of an international collaboration. The experiment pursues a systematic investigation of non-strange and strange meson photoproduction, in particular $t$-channel processes at low momentum transfer. The setup uniquely combines a central almost $4π$ acceptance BGO crystal calorimeter with a large aperture for…
▽ More
The BGOOD experiment at the ELSA facility in Bonn has been commissioned within the framework of an international collaboration. The experiment pursues a systematic investigation of non-strange and strange meson photoproduction, in particular $t$-channel processes at low momentum transfer. The setup uniquely combines a central almost $4π$ acceptance BGO crystal calorimeter with a large aperture forward magnetic spectrometer providing excellent detection of both neutral and charged particles, complementary to other setups such as Crystal Barrel, Crystal Ball, LEPS and CLAS.
△ Less
Submitted 18 February, 2020; v1 submitted 24 October, 2019;
originally announced October 2019.
-
Characterising encapsulated nuclear waste using cosmic-ray muon tomography
Authors:
Anthony Clarkson,
David J. Hamilton,
Matthias Hoek,
David G. Ireland,
John R. Johnstone,
Ralf Kaiser,
Tibor Keri,
Scott Lumsden,
David F. Mahon,
Bryan McKinnon,
Morgan Murray,
Siân Nutbeam-Tuffs,
Craig Shearer,
Guangliang Yang,
Colin Zimmerman
Abstract:
Tomographic imaging techniques using the Coulomb scattering of cosmic-ray muons have been shown previously to successfully identify and characterise low- and high-Z materials within an air matrix using a prototype scintillating-fibre tracker system. Those studies were performed as the first in a series to assess the feasibility of this technology and image reconstruction techniques in characterisi…
▽ More
Tomographic imaging techniques using the Coulomb scattering of cosmic-ray muons have been shown previously to successfully identify and characterise low- and high-Z materials within an air matrix using a prototype scintillating-fibre tracker system. Those studies were performed as the first in a series to assess the feasibility of this technology and image reconstruction techniques in characterising the potential high-Z contents of legacy nuclear waste containers for the UK Nuclear Industry. The present work continues the feasibility study and presents the first images reconstructed from experimental data collected using this small-scale prototype system of low- and high-Z materials encapsulated within a concrete-filled stainless-steel container. Clear discrimination is observed between the thick steel casing, the concrete matrix and the sample materials assayed. These reconstructed objects are presented and discussed in detail alongside the implications for future industrial scenarios.
△ Less
Submitted 27 October, 2014;
originally announced October 2014.