Improved limit on neutrinoless double beta decay of \mohundred~from AMoRE-I
Authors:
A. Agrawal,
V. V. Alenkov,
P. Aryal,
J. Beyer,
B. Bhandari,
R. S. Boiko,
K. Boonin,
O. Buzanov,
C. R. Byeon,
N. Chanthima,
M. K. Cheoun,
J. S. Choe,
Seonho Choi,
S. Choudhury,
J. S. Chung,
F. A. Danevich,
M. Djamal,
D. Drung,
C. Enss,
A. Fleischmann,
A. M. Gangapshev,
L. Gastaldo,
Y. M. Gavrilyuk,
A. M. Gezhaev,
O. Gileva
, et al. (83 additional authors not shown)
Abstract:
AMoRE searches for the signature of neutrinoless double beta decay of $^{100}$Mo with a 100 kg sample of enriched $^{100}$Mo. Scintillating molybdate crystals coupled with a metallic magnetic calorimeter operate at milli-Kelvin temperatures to measure the energy of electrons emitted in the decay. As a demonstration of the full-scale AMoRE, we conducted AMoRE-I, a pre-experiment with 18 molybdate c…
▽ More
AMoRE searches for the signature of neutrinoless double beta decay of $^{100}$Mo with a 100 kg sample of enriched $^{100}$Mo. Scintillating molybdate crystals coupled with a metallic magnetic calorimeter operate at milli-Kelvin temperatures to measure the energy of electrons emitted in the decay. As a demonstration of the full-scale AMoRE, we conducted AMoRE-I, a pre-experiment with 18 molybdate crystals, at the Yangyang Underground Laboratory for over two years. The exposure was 8.02 kg$\cdot$year (or 3.89 kg$_{\mathrm{^{100}Mo}}\cdot$year) and the total background rate near the Q-value was 0.025 $\pm$ 0.002 counts/keV/kg/year. We observed no indication of $0νββ$ decay and report a new lower limit of the half-life of $^{100}$Mo $0νββ$ decay as $ T^{0ν}_{1/2}>3.0\times10^{24}~\mathrm{years}$ at 90\% confidence level. The effective Majorana mass limit range is $m_{ββ}<$(210--610) meV using nuclear matrix elements estimated in the framework of different models, including the recent shell model calculations.
△ Less
Submitted 8 July, 2024;
originally announced July 2024.
-
Background study of the AMoRE-pilot experiment
Authors:
A. Agrawal,
V. V. Alenkov,
P. Aryal,
J. Beyer,
B. Bhandari,
R. S. Boiko,
K. Boonin,
O. Buzanov,
C. R. Byeon,
N. Chanthima,
M. K. Cheoun,
J. S. Choe,
Seonho Choi,
S. Choudhury,
J. S. Chung,
F. A. Danevich,
M. Djamal,
D. Drung,
C. Enss,
A. Fleischmann,
A. M. Gangapshev,
L. Gastaldo,
Yu. M. Gavrilyuk,
A. M. Gezhaev,
O. Gileva
, et al. (83 additional authors not shown)
Abstract:
We report a study on the background of the Advanced Molybdenum-Based Rare process Experiment (AMoRE), a search for neutrinoless double beta decay (\znbb) of $^{100}$Mo. The pilot stage of the experiment was conducted using $\sim$1.9 kg of \CAMOO~ crystals at the Yangyang Underground Laboratory, South Korea, from 2015 to 2018. We compared the measured $β/γ$ energy spectra in three experimental conf…
▽ More
We report a study on the background of the Advanced Molybdenum-Based Rare process Experiment (AMoRE), a search for neutrinoless double beta decay (\znbb) of $^{100}$Mo. The pilot stage of the experiment was conducted using $\sim$1.9 kg of \CAMOO~ crystals at the Yangyang Underground Laboratory, South Korea, from 2015 to 2018. We compared the measured $β/γ$ energy spectra in three experimental configurations with the results of Monte Carlo simulations and identified the background sources in each configuration. We replaced several detector components and enhanced the neutron shielding to lower the background level between configurations. A limit on the half-life of $0νββ$ decay of $^{100}$Mo was found at $T_{1/2}^{0ν} \ge 3.0\times 10^{23}$ years at 90\% confidence level, based on the measured background and its modeling. Further reduction of the background rate in the AMoRE-I and AMoRE-II are discussed.
△ Less
Submitted 7 April, 2024; v1 submitted 15 January, 2024;
originally announced January 2024.
-
Characteristics of a matrix proportional counter with circular anodes
Authors:
R. A. Etezov,
Yu. M. Gavrilyuk,
A. M. Gangapshev,
V. V. Kazalov,
A. Kh. Khokonov,
V. V. Kuzminov,
S. I. Panasenko,
S. S Ratkevich
Abstract:
The construction of a butt-end multicell matrix proportional counter (MMPC) is presented in the work. Each cell is a butt-end proportional counter with a 5 mm cathode diameter and 0.8 mm circular anode diameter. In the example of the $3\times3$ matrix, it is shown that the gas multiplication of the central cell depends on the potentials at the anodes of the peripheral cells, the drift electrode, t…
▽ More
The construction of a butt-end multicell matrix proportional counter (MMPC) is presented in the work. Each cell is a butt-end proportional counter with a 5 mm cathode diameter and 0.8 mm circular anode diameter. In the example of the $3\times3$ matrix, it is shown that the gas multiplication of the central cell depends on the potentials at the anodes of the peripheral cells, the drift electrode, the forming rings, and the surrounding metal parts of the structure. The amplitude characteristics were measured when the MMPC was filled with mixtures of 96.3\% Ar + 3.7\% Xe and 90\% Ar + 10\% CH$_4$ at pressures of 620 Torr and 62 Torr. The calibration was carried out with $α$-particles and $γ$-quanta from a $^{238}$Pu source. For photons with energies of 7.5 keV, a resolution of 26\% was obtained. It is shown that, based on MMPC, it is possible to fabricate recording surfaces of arbitrary configuration.
△ Less
Submitted 4 January, 2022;
originally announced January 2022.
-
$^{222}$Rn content variations at ground and underground conditions
Authors:
R. A. Etezov,
Yu. M. Gavrilyuk,
A. M. Gangapshev,
A. M. Gezhaev,
V. V. Kazalov,
A. Kh. Khokonov,
V. V. Kuzminov,
S. I. Panasenko,
S. S. Ratkevich
Abstract:
The activity of $^{222}$Rn and its daughter isotopes was measured in the air of several underground laboratories of the Baksan Neutrino Observatory at various distances from the entrance. The measurements were carried out with the help of the cylindrical ionionization air chamber. We found that the radon content in the ventilated airflow within the measurement accuracy does not depend on the dista…
▽ More
The activity of $^{222}$Rn and its daughter isotopes was measured in the air of several underground laboratories of the Baksan Neutrino Observatory at various distances from the entrance. The measurements were carried out with the help of the cylindrical ionionization air chamber. We found that the radon content in the ventilated airflow within the measurement accuracy does not depend on the distance travelled along the adit. In addition, we observed that the radon content increases abruptly in those locations where underground gases and water are released. As a result, we review various mechanisms of air enrichment with radon. We also outline our research methodology and present the results of our measurements of radon release from the rocky walls of the underground laboratory. Finally, we present the results of the measurements of the radon content of various ground and underground water sources.
△ Less
Submitted 9 January, 2022; v1 submitted 28 October, 2021;
originally announced October 2021.
-
Annual variations of the $^{214}$Po, $^{213}$Po and $^{212}$Po half-life values
Authors:
E. N. Alexeev,
A. M. Gangapshev,
Yu. M. Gavrilyuk,
A. M. Gezhaev,
V. V. Kazalov,
V. V. Kuzminov,
S. I. Panasenko,
O. D. Petrenko,
S. S. Ratkevich
Abstract:
Results of a comparative analysis of the $^{214}$Po ($T_{1/2}= 163.47\pm0.03$ $μ$s), $^{213}$Po ($T_{1/2}=3.705 \pm 0.001$ $μ$s) and $^{212}$Po ($T_{1/2}=294.09\pm0.07$ ns) half-life annular variation parameters are presented. It is shown that two independent sequential sets of the $^{214}$Po $τ$-values $(τ\equiv T_{1/2})$ obtained in the spaced laboratories can be described by sinusoidal function…
▽ More
Results of a comparative analysis of the $^{214}$Po ($T_{1/2}= 163.47\pm0.03$ $μ$s), $^{213}$Po ($T_{1/2}=3.705 \pm 0.001$ $μ$s) and $^{212}$Po ($T_{1/2}=294.09\pm0.07$ ns) half-life annular variation parameters are presented. It is shown that two independent sequential sets of the $^{214}$Po $τ$-values $(τ\equiv T_{1/2})$ obtained in the spaced laboratories can be described by sinusoidal functions. The sinusoid curve with amplitude $A=(5.0 \pm1.5) \cdot 10^{-4}$, period $ω=(365\pm 8)$ days, and phase $φ=(170 \pm 7)$ days approximates the set of $^{214}$Po $τ$ values obtained at BNO INR RAS during the $\sim$973 days starting on January 4, 2012. The function approximates a set of $τ$-values with a time duration of $\sim1460$ days obtained at the KhNU has an amplitude $A=(4.9\pm1.8)\cdot10^{-4}$, a period $ω= (377\pm13)$ days and a phase $φ=(77\pm10)$ days. The $^{213}$Po $τ$-value set with a time duration of $\sim1700$ days can be described by a sinusoidal function with an amplitude $A=(3.9\pm1.2)\cdot10^{-4}$, a period $ω= (370\pm13)$ days and a phase $φ=(130\pm9)$ days. The $^{212}$Po $τ$-value set with a time duration of $\sim670$ days can be described by a sinusoidal function with an amplitude $A=(7.5\pm1.6)\cdot10^{-4}$, a period $ω= (375\pm13)$ days and a phase $φ=(40\pm10)$ days.
△ Less
Submitted 16 October, 2020;
originally announced October 2020.
-
Search for Variations of Po-213 Half-Life
Authors:
E. N. Alexeyev,
Yu. M. Gavrilyuk,
A. M. Gangapshev,
A. M. Gezhaev,
V. V. Kazalov,
V. V. Kuzminov,
S. I. Panasenko,
S. S. Ratkevich
Abstract:
A device with the parent $^{229}$Th source was constructed to search for variations of the daughter $^{213}$Po half-life ($T_{1/2} = 4.2$ $μ$s). A solar-daily variation with amplitude $A_{So}=(5.3 \pm 1.1) \times 10^{-4}$, a lunar-daily variation with amplitude $A_L = (4.8 \pm 2.1) \times 10^{-4}$, and a sidereal-daily variation with amplitude $A_S = (4.2 \pm 1.7) \times 10^{-4}$ were found upon p…
▽ More
A device with the parent $^{229}$Th source was constructed to search for variations of the daughter $^{213}$Po half-life ($T_{1/2} = 4.2$ $μ$s). A solar-daily variation with amplitude $A_{So}=(5.3 \pm 1.1) \times 10^{-4}$, a lunar-daily variation with amplitude $A_L = (4.8 \pm 2.1) \times 10^{-4}$, and a sidereal-daily variation with amplitude $A_S = (4.2 \pm 1.7) \times 10^{-4}$ were found upon proceeding the data series over a 622-day interval (from July 2015 to March 2017). The $^{213}$Po half-life mean value is found to be $T_{1/2} = 3.705 \pm 0.001$ $μ$s. The obtained half-life is in good agreement with some of the literature values obtained with great accuracy.
△ Less
Submitted 18 June, 2018; v1 submitted 4 June, 2018;
originally announced June 2018.
-
Recent results of search for solar axions using resonant absorption by $^{83}$Kr nuclei
Authors:
A. V. Derbin,
I. S. Drachnev,
A. M. Gangapshev,
Yu. M. Gavrilyuk,
V. V. Kazalov,
V. V. Kobychev,
V. V. Kuzminov,
V. N. Muratova,
S. I. Panasenko,
S. S. Ratkevich,
D. A. Tekueva,
E. V. Unzhakov,
S. P. Yakimenko
Abstract:
A search for resonant absorption of the solar axion by $^{83}\rm{Kr}$ nuclei was performed using the proportional counter installed inside the low-background setup at the Baksan Neutrino Observatory. The obtained model independent upper limit on the combination of isoscalar and isovector axion-nucleon couplings $|g_3-g_0|\leq 8.4\times 10^{-7}$ allowed us to set the new upper limit on the hadronic…
▽ More
A search for resonant absorption of the solar axion by $^{83}\rm{Kr}$ nuclei was performed using the proportional counter installed inside the low-background setup at the Baksan Neutrino Observatory. The obtained model independent upper limit on the combination of isoscalar and isovector axion-nucleon couplings $|g_3-g_0|\leq 8.4\times 10^{-7}$ allowed us to set the new upper limit on the hadronic axion mass of $m_{A}\leq 65$ eV (95\% C.L.) with the generally accepted values $S$=0.5 and $z$=0.56.
△ Less
Submitted 9 November, 2017;
originally announced November 2017.
-
Comparative study of the double $K$-shell-vacancy production in single- and double-electron capture decay
Authors:
S. S. Ratkevich,
A. M. Gangapshev,
Yu. M. Gavrilyuk,
F. F. Karpeshin,
V. V. Kazalov,
V. V. Kuzminov,
S. I. Panasenko,
M. B. Trzhaskovskaya,
S. P. Yakimenko
Abstract:
We carried out the comparative study of the signal from the decay of double $K$-shell vacancy production that follows after single $K$-shell electron capture of $^{81}$Kr and double $K$-shell electron capture of $^{78}$Kr. The radiative decay of a the double $1s$ vacancy state was identified by detecting the triple coincidence of two $K$ X-rays and several Auger electrons in the $ECEC$-decay, or b…
▽ More
We carried out the comparative study of the signal from the decay of double $K$-shell vacancy production that follows after single $K$-shell electron capture of $^{81}$Kr and double $K$-shell electron capture of $^{78}$Kr. The radiative decay of a the double $1s$ vacancy state was identified by detecting the triple coincidence of two $K$ X-rays and several Auger electrons in the $ECEC$-decay, or by detecting two $K$ X-rays and (Auger electrons + ejected $K$-shell electron) in the $EC$ decay. The number of $K$-shell vacancies per the $K$-electron capture, produced as a result of the shake-off process, has been measured for the decay of $^{81}$Kr. The probability for this decay was found to be $P_{KK}=(5.7\pm0.8)\times10^{-5}$ with a systematic error of $(ΔP_{KK})_{syst}=\pm0.4 \times10^{-5}$. For the $^{78}{\rm{Kr}}(2\nu2K)$ decay, the comparative study of single- and double-capture decays allowed us to obtain the signal-to-background ratio to be 15/1. The half-life $T_{1/2}^{2\nu2K}(g.s. \rightarrow g.s.) = [1.9^{+1.3}_{-0.7}(stat)\pm0.3(syst)]\times 10^{22}$ y is determined from the analysis of data that have been accumulated over 782 days of live measurements in the experiment that used samples consisted of 170.6 g of $^{78}$Kr.
△ Less
Submitted 6 September, 2017; v1 submitted 22 July, 2017;
originally announced July 2017.
-
Characteristics of a thermal neutrons scintillation detector with the [ZnS(Ag)+$^6$LiF] at different conditions of measurements
Authors:
V. V. Alekseenko,
I. R. Barabanov,
R. A. Etezov,
Yu. M. Gavrilyuk,
A. M. Gangapshev,
A. M. Gezhaev,
V. V. Kazalov,
A. Kh. Khokonov,
V. V. Kuzminov,
S. I. Panasenko,
S. S. Ratkevich
Abstract:
A construction of a thermal neutron testing detector with a thin [ZnS(Ag)+$^6$LiF] scintillator is described. Results of an investigation of sources of the detector pulse origin and the pulse features in a ground and underground conditions are presented. Measurements of the scintillator own background, registration efficiency and a neutron flux at different objects of the BNO INR RAS were performe…
▽ More
A construction of a thermal neutron testing detector with a thin [ZnS(Ag)+$^6$LiF] scintillator is described. Results of an investigation of sources of the detector pulse origin and the pulse features in a ground and underground conditions are presented. Measurements of the scintillator own background, registration efficiency and a neutron flux at different objects of the BNO INR RAS were performed. The results are compared with the ones measured by the $^3$He proportional counter.
△ Less
Submitted 30 October, 2015;
originally announced October 2015.
-
Results of measurements of an environment neutron background at BNO INR RAS objects with the helium proportional counter
Authors:
V. V. Alekseenko,
I. R. Barabanov,
R. A. Etezov,
Yu. M. Gavrilyuk,
A. M. Gangapshev,
A. M. Gezhaev,
V. V. Kazalov,
A. Kh. Khokonov,
V. V. Kuzminov,
S. I. Panasenko,
S. S. Ratkevich
Abstract:
A method of measurements of the environmental neutron background at the Baksan Neutrino Observatory of the INR RAS are described. Measurements were done by using of a proportional counter filled with mixture of Ar(2 at)+$^3$He(4 at). The results obtained at the surface and the underground laboratory of the BNO INR RAS are presented. It is shown that a neutron background in the underground laborato…
▽ More
A method of measurements of the environmental neutron background at the Baksan Neutrino Observatory of the INR RAS are described. Measurements were done by using of a proportional counter filled with mixture of Ar(2 at)+$^3$He(4 at). The results obtained at the surface and the underground laboratory of the BNO INR RAS are presented. It is shown that a neutron background in the underground laboratory at the 4900 m w.e. depth is decreased by $\sim 260$ times without any special shield in a comparison with the Earth surface. A neutron flux density in the 5-1323.5~cm air height region is constant within the determination error and equal to $(7.1\pm0.1_{\rm{stat}}\pm0.3_{\rm{syst}})\times10^{-3}$ s$^{-1}\cdot$cm$^{-2}$.
△ Less
Submitted 29 October, 2015; v1 submitted 17 October, 2015;
originally announced October 2015.
-
The study of the thermal neutron flux in the deep underground laboratory DULB-4900
Authors:
V. V. Alekseenko,
Yu. M. Gavrilyuk,
A. M. Gangapshev,
A. M. Gezhaev,
D. D. Dzhappuev,
V. V. Kazalov,
A. U. Kudzhaev,
V. V. Kuzminov,
S. I. Panasenko,
S. S. Ratkevich,
D. A. Tekueva,
S. P. Yakimenko,
Yu. V. Sten'kin
Abstract:
We report on the study of thermal neutron flux using monitors based on mixture of ZnS(Ag) and LiF enriched with a lithium-6 isotope at the deep underground laboratory DULB-4900 at the Baksan Neutrino Observatory. An annual modulation of thermal neutron flux in DULB-4900 is observed. Experimental evidences were obtained of correlation between the long-term thermal neutron flux variations and the ab…
▽ More
We report on the study of thermal neutron flux using monitors based on mixture of ZnS(Ag) and LiF enriched with a lithium-6 isotope at the deep underground laboratory DULB-4900 at the Baksan Neutrino Observatory. An annual modulation of thermal neutron flux in DULB-4900 is observed. Experimental evidences were obtained of correlation between the long-term thermal neutron flux variations and the absolute humidity of the air in laboratory. The amplitude of the modulation exceed 5\% of total neutron flux.
△ Less
Submitted 24 July, 2015; v1 submitted 20 July, 2015;
originally announced July 2015.
-
Search for 2K(2ν)-capture of Xe-124
Authors:
Yu. M. Gavrilyuk,
A. M. Gangapshev,
V. V. Kazalov,
V. V. Kuzminov,
S. I. Panasenko,
S. S. Ratkevich,
D. A. Tekueva,
S. P. Yakimenko
Abstract:
The results of a search for two neutrino mode of double K-capture of Xe-124 using a large copper low-background proportional counter are presented. Data collected during 3220 hours of measurements with 58.6 g of $^{124}$Xe provides us to a new limit on the half-life of Xe-124 regarding 2K-capture at the level: T_{1/2} >= 2.0*10^{21} years at a 90\% confidence level.
The results of a search for two neutrino mode of double K-capture of Xe-124 using a large copper low-background proportional counter are presented. Data collected during 3220 hours of measurements with 58.6 g of $^{124}$Xe provides us to a new limit on the half-life of Xe-124 regarding 2K-capture at the level: T_{1/2} >= 2.0*10^{21} years at a 90\% confidence level.
△ Less
Submitted 16 July, 2015;
originally announced July 2015.
-
The origin of the background radioactive isotope Xe-127 in the sample of Xe enriched in Xe-124
Authors:
Yu. M. Gavrilyuk,
A. M. Gangapshev,
V. V. Kazalov,
V. V. Kuzminov,
S. I. Panasenko,
S. S. Ratkevich,
D. A. Tekueva,
S. P. Yakimenko
Abstract:
The results of investigation of Xe-127 radioactive isotope production in the xenon sample enriched in Xe-124, Xe-126, Xe-128 are presented. The isotope is supposed to be the source of the background events in the low-background experiment on search for 2K-capture of Xe-124. In this work we consider two channels of Xe-127 production: the neutron knock-out from Xe-128 nucleus by cosmogenic muons and…
▽ More
The results of investigation of Xe-127 radioactive isotope production in the xenon sample enriched in Xe-124, Xe-126, Xe-128 are presented. The isotope is supposed to be the source of the background events in the low-background experiment on search for 2K-capture of Xe-124. In this work we consider two channels of Xe-127 production: the neutron knock-out from Xe-128 nucleus by cosmogenic muons and the neutron capture by Xe-126 nucleus. For the first channel the upper limit of the cross section of Xe-127 production was found to be sigma >= 0.007 barn at 95\% C.L. For the second channel the value obtained for the cross section was found to be equal to sigma =(2.74+-0.4) barn, which coincides well, within the statistical error, with reference value.
△ Less
Submitted 15 July, 2015;
originally announced July 2015.
-
Results of a search for daily and annual variations of the Po-214 half-life at the two year observation period
Authors:
E. N. Alexeyev,
Yu. M. Gavrilyuk,
A. M. Gangapshev,
V. V. Kazalov,
V. V. Kuzminov,
S. I. Panasenko,
S. S. Ratkevich
Abstract:
The brief description of installation TAU-2 intended for long-term monitoring of the half-life value $τ$ ($τ_{1/2}$) of the $^{214}$Po is presented. The methods of measurement and processing of collected data are reported. The results of analysis of time series values $τ$ with different time step are presented. Total of measurement time was equal to 590 days. Averaged value of the $^{214}$Po half-…
▽ More
The brief description of installation TAU-2 intended for long-term monitoring of the half-life value $τ$ ($τ_{1/2}$) of the $^{214}$Po is presented. The methods of measurement and processing of collected data are reported. The results of analysis of time series values $τ$ with different time step are presented. Total of measurement time was equal to 590 days. Averaged value of the $^{214}$Po half-life was obtained $τ=163.46\pm0.04$ $μ$s. The annual variation with an amplitude $A=(8.9\pm2.3)\cdot10^{-4}$, solar-daily variation with an amplitude $A_{So}=(7.5\pm1.2)\cdot10^{-4}$, lunar-daily variation with an amplitude $A_L=(6.9\pm2.0)\cdot10^{-4}$ and sidereal-daily variation with an amplitude $A_S=(7.2\pm1.2)\cdot10^{-4}$ were found in a series of $τ$ values. The maximal values of amplitude are observed at the moments when the projections of the installation Earth location velocity vectors toward the source of possible variation achieve its maximal magnitudes.
△ Less
Submitted 7 May, 2015;
originally announced May 2015.
-
First result of the experimental search for the 9.4 keV solar axion reactions with Kr-83 in the copper proportional counter
Authors:
Yu. M. Gavrilyuk,
A. M. Gangapshev,
A. V. Derbin,
V. V. Kazalov,
H. J. Kim,
Y. D. Kim,
V. V. Kobychev,
V. V. Kuzminov,
Luqman Ali,
V. N. Muratova,
S. I. Panasenko,
S. S. Ratkevich,
D. A. Semenov,
D. A. Tekueva,
S. P. Yakimenko,
E. V. Unzhakov
Abstract:
The experimental search for solar hadronic axions is started at the Baksan Neutrino Observatory of the Institute for Nuclear Researches Russian Academy of Science. It is assumed that axions are created in the Sun during M1-transition between the first thermally excited level at 9.4 keV and the ground state in Kr-83. The experiment is based on axion detection via resonant absorption process by the…
▽ More
The experimental search for solar hadronic axions is started at the Baksan Neutrino Observatory of the Institute for Nuclear Researches Russian Academy of Science. It is assumed that axions are created in the Sun during M1-transition between the first thermally excited level at 9.4 keV and the ground state in Kr-83. The experiment is based on axion detection via resonant absorption process by the same nucleus in the detector. The big copper proportional counter filled with krypton is used to detect signals from axions. The experimental setup is situated in the deep underground low background laboratory. No evidence of axion detection were found after the 26.5 days data collection. Resulting new upper limit on axion mass is m_{A} < 130 eV at 95% C.L.
△ Less
Submitted 6 May, 2014;
originally announced May 2014.
-
Sources of the systematic errors in measurements of Po-214 decay half-life time variations at the Baksan deep underground experiments
Authors:
E. N. Alexeyev,
Yu. M. Gavrilyuk,
A. M. Gangapshev,
V. V. Kazalov,
V. V. Kuzminov,
S. I. Panasenko,
S. S. Ratkevich
Abstract:
The design changes of the Baksan low-background TAU-1 and TAU-2 set-ups allowed to improve a sensitivity of Po-214 half-life (τ) measurements up to the 2.5 x 10^{-4} are described. Different possible sources of systematic errors influencing on the $τ$-value are studed. An annual variation of Po-214 half-life time measurements with an amplitude of A=(6.9 \pm 3) x 10^{-4} and a phase of (φ=93 \pm 10…
▽ More
The design changes of the Baksan low-background TAU-1 and TAU-2 set-ups allowed to improve a sensitivity of Po-214 half-life (τ) measurements up to the 2.5 x 10^{-4} are described. Different possible sources of systematic errors influencing on the $τ$-value are studed. An annual variation of Po-214 half-life time measurements with an amplitude of A=(6.9 \pm 3) x 10^{-4} and a phase of (φ=93 \pm 10) days was found in a sequence of the week-collected τ-values obtained from the TAU-2 data sample with total duration of 480 days. 24 hours' variation of the τ-value measurements with an amplitude of A=(10.0 \pm 2.6) x 10^{-4} and phase of (φ=1 \pm 0.5) hours was found in a solar day 1 hour step τ-value sequence formed from the same data sample. It was found that the Po-214 half-life averaged at 480 days is equal to (163.45 \pm 0.04) mks.
△ Less
Submitted 23 April, 2014;
originally announced April 2014.
-
First result of the experimental search for the 2K-capture of Xe-124 with the copper proportional counter
Authors:
Yu. M. Gavrilyuk,
A. M. Gangapshev,
V. V. Kazalov,
V. V. Kuzminov,
S. I. Panasenko,
S. S. Ratkevich,
D. A. Tekueva,
S. P. Yakimenko
Abstract:
First result of experiment for searching of 2K-capture of Xe-124 with the large-volume copper proportional counter is given. The 12 litre sample with 63.3% (44 g) of Xe-124 was used in measurements. The limit on the half-life of Xe-124 with regard to 2K(2ν)-capture for the ground state of Te-124 has been found: T_{1/2} > 4.67x10^{20} y (90% C.L.). A sample with volume 52 L comprising of Xe-124 (10…
▽ More
First result of experiment for searching of 2K-capture of Xe-124 with the large-volume copper proportional counter is given. The 12 litre sample with 63.3% (44 g) of Xe-124 was used in measurements. The limit on the half-life of Xe-124 with regard to 2K(2ν)-capture for the ground state of Te-124 has been found: T_{1/2} > 4.67x10^{20} y (90% C.L.). A sample with volume 52 L comprising of Xe-124 (10.6 L - 58.6 g) and Xe-126 (14.1 L - 79.3 g) will used at the next step of the experiment to increase a sensitivity of 2K-caption of Xe-124 registration. In this case sensitivity to the investigated process will be at the level of S=1.46 x 10^{21} y (90% C.L.) for 1 year measurement.
△ Less
Submitted 22 April, 2014;
originally announced April 2014.
-
Results of wavelet processing of the 2K-capture Kr-78 experiment statistics
Authors:
Yu. M. Gavrilyuk,
A. M. Gangapshev,
V. V. Kazalov,
V. V. Kuzminov,
S. I. Panasenko,
S. S. Ratkevich
Abstract:
Results of a search for Kr-78 double K-capture with the large low-background proportional counter (2005-2008 years) at the Baksan Neutrino Observatory are presented. An experimental method and characteristics of detectors are described. Basic features of the digitized pulses processing using wavelet transform are considered. With due account taken of the analysis of individual noise characteristic…
▽ More
Results of a search for Kr-78 double K-capture with the large low-background proportional counter (2005-2008 years) at the Baksan Neutrino Observatory are presented. An experimental method and characteristics of detectors are described. Basic features of the digitized pulses processing using wavelet transform are considered. With due account taken of the analysis of individual noise characteristic it has been shown that the appropriate choice of both wavelet characteristics and sequence of processing algorithms allows one to decrease the background in the energy region of useful events with a unique set of characteristics by ~2000 times. New limit on the half-life of Kr-78 with regard to 2K-capture has been found: T_{1/2} >= 2.4E21 yrs (90% C.L.).
△ Less
Submitted 26 June, 2010;
originally announced June 2010.