-
Detailed Report on the Measurement of the Positive Muon Anomalous Magnetic Moment to 0.20 ppm
Authors:
D. P. Aguillard,
T. Albahri,
D. Allspach,
A. Anisenkov,
K. Badgley,
S. Baeßler,
I. Bailey,
L. Bailey,
V. A. Baranov,
E. Barlas-Yucel,
T. Barrett,
E. Barzi,
F. Bedeschi,
M. Berz,
M. Bhattacharya,
H. P. Binney,
P. Bloom,
J. Bono,
E. Bottalico,
T. Bowcock,
S. Braun,
M. Bressler,
G. Cantatore,
R. M. Carey,
B. C. K. Casey
, et al. (168 additional authors not shown)
Abstract:
We present details on a new measurement of the muon magnetic anomaly, $a_μ= (g_μ-2)/2$. The result is based on positive muon data taken at Fermilab's Muon Campus during the 2019 and 2020 accelerator runs. The measurement uses $3.1$ GeV$/c$ polarized muons stored in a $7.1$-m-radius storage ring with a $1.45$ T uniform magnetic field. The value of $ a_μ$ is determined from the measured difference b…
▽ More
We present details on a new measurement of the muon magnetic anomaly, $a_μ= (g_μ-2)/2$. The result is based on positive muon data taken at Fermilab's Muon Campus during the 2019 and 2020 accelerator runs. The measurement uses $3.1$ GeV$/c$ polarized muons stored in a $7.1$-m-radius storage ring with a $1.45$ T uniform magnetic field. The value of $ a_μ$ is determined from the measured difference between the muon spin precession frequency and its cyclotron frequency. This difference is normalized to the strength of the magnetic field, measured using Nuclear Magnetic Resonance (NMR). The ratio is then corrected for small contributions from beam motion, beam dispersion, and transient magnetic fields. We measure $a_μ= 116 592 057 (25) \times 10^{-11}$ (0.21 ppm). This is the world's most precise measurement of this quantity and represents a factor of $2.2$ improvement over our previous result based on the 2018 dataset. In combination, the two datasets yield $a_μ(\text{FNAL}) = 116 592 055 (24) \times 10^{-11}$ (0.20 ppm). Combining this with the measurements from Brookhaven National Laboratory for both positive and negative muons, the new world average is $a_μ$(exp) $ = 116 592 059 (22) \times 10^{-11}$ (0.19 ppm).
△ Less
Submitted 22 May, 2024; v1 submitted 23 February, 2024;
originally announced February 2024.
-
A first test of CUPID prototypal light detectors with NTD-Ge sensors in a pulse-tube cryostat
Authors:
CUPID collaboration,
K. Alfonso,
A. Armatol,
C. Augier,
F. T. Avignone III,
O. Azzolini,
M. Balata,
A. S. Barabash,
G. Bari,
A. Barresi,
D. Baudin,
F. Bellini,
G. Benato,
V. Berest,
M. Beretta,
M. Bettelli,
M. Biassoni,
J. Billard,
V. Boldrini,
A. Branca,
C. Brofferio,
C. Bucci,
J. Camilleri,
A. Campani,
C. Capelli
, et al. (154 additional authors not shown)
Abstract:
CUPID is a next-generation bolometric experiment aiming at searching for neutrinoless double-beta decay with ~250 kg of isotopic mass of $^{100}$Mo. It will operate at $\sim$10 mK in a cryostat currently hosting a similar-scale bolometric array for the CUORE experiment at the Gran Sasso National Laboratory (Italy). CUPID will be based on large-volume scintillating bolometers consisting of…
▽ More
CUPID is a next-generation bolometric experiment aiming at searching for neutrinoless double-beta decay with ~250 kg of isotopic mass of $^{100}$Mo. It will operate at $\sim$10 mK in a cryostat currently hosting a similar-scale bolometric array for the CUORE experiment at the Gran Sasso National Laboratory (Italy). CUPID will be based on large-volume scintillating bolometers consisting of $^{100}$Mo-enriched Li$_2$MoO$_4$ crystals, facing thin Ge-wafer-based bolometric light detectors. In the CUPID design, the detector structure is novel and needs to be validated. In particular, the CUORE cryostat presents a high level of mechanical vibrations due to the use of pulse tubes and the effect of vibrations on the detector performance must be investigated. In this paper we report the first test of the CUPID-design bolometric light detectors with NTD-Ge sensors in a dilution refrigerator equipped with a pulse tube in an above-ground lab. Light detectors are characterized in terms of sensitivity, energy resolution, pulse time constants, and noise power spectrum. Despite the challenging noisy environment due to pulse-tube-induced vibrations, we demonstrate that all the four tested light detectors comply with the CUPID goal in terms of intrinsic energy resolution of 100 eV RMS baseline noise. Indeed, we have measured 70--90 eV RMS for the four devices, which show an excellent reproducibility. We have also obtained outstanding energy resolutions at the 356 keV line from a $^{133}$Ba source with one light detector achieving 0.71(5) keV FWHM, which is -- to our knowledge -- the best ever obtained when compared to $γ$ detectors of any technology in this energy range.
△ Less
Submitted 10 April, 2023;
originally announced April 2023.
-
Twelve-crystal prototype of Li$_2$MoO$_4$ scintillating bolometers for CUPID and CROSS experiments
Authors:
CUPID,
CROSS collaborations,
:,
K. Alfonso,
A. Armatol,
C. Augier,
F. T. Avignone III,
O. Azzolini,
M. Balata,
I. C. Bandac,
A. S. Barabash,
G. Bari,
A. Barresi,
D. Baudin,
F. Bellini,
G. Benato,
V. Berest,
M. Beretta,
M. Bettelli,
M. Biassoni,
J. Billard,
V. Boldrini,
A. Branca,
C. Brofferio,
C. Bucci
, et al. (160 additional authors not shown)
Abstract:
An array of twelve 0.28 kg lithium molybdate (LMO) low-temperature bolometers equipped with 16 bolometric Ge light detectors, aiming at optimization of detector structure for CROSS and CUPID double-beta decay experiments, was constructed and tested in a low-background pulse-tube-based cryostat at the Canfranc underground laboratory in Spain. Performance of the scintillating bolometers was studied…
▽ More
An array of twelve 0.28 kg lithium molybdate (LMO) low-temperature bolometers equipped with 16 bolometric Ge light detectors, aiming at optimization of detector structure for CROSS and CUPID double-beta decay experiments, was constructed and tested in a low-background pulse-tube-based cryostat at the Canfranc underground laboratory in Spain. Performance of the scintillating bolometers was studied depending on the size of phonon NTD-Ge sensors glued to both LMO and Ge absorbers, shape of the Ge light detectors (circular vs. square, from two suppliers), in different light collection conditions (with and without reflector, with aluminum coated LMO crystal surface). The scintillating bolometer array was operated over 8 months in the low-background conditions that allowed to probe a very low, $μ$Bq/kg, level of the LMO crystals radioactive contamination by $^{228}$Th and $^{226}$Ra.
△ Less
Submitted 10 April, 2023;
originally announced April 2023.
-
Toward CUPID-1T
Authors:
A. Armatol,
C. Augier,
F. T. Avignone III,
O. Azzolini,
M. Balata,
K. Ballen,
A. S. Barabash,
G. Bari,
A. Barresi,
D. Baudin,
F. Bellini,
G. Benato,
M. Beretta,
M. Bettelli,
M. Biassoni,
J. Billard,
V. Boldrini,
A. Branca,
C. Brofferio,
C. Bucci,
J. Camilleri,
C. Capelli,
S. Capelli,
L. Cappelli,
L. Cardani
, et al. (150 additional authors not shown)
Abstract:
Current experiments to search for broken lepton-number symmetry through the observation of neutrinoless double-beta decay ($0\mathrm{νββ}$) provide the most stringent limits on the Majorana nature of neutrinos and the effective Majorana neutrino mass ($m_{ββ}$). The next-generation experiments will focus on the sensitivity to the $0\mathrm{νββ}$ half-life of $\mathcal{O}(10^{27}$--$10^{28}$~years…
▽ More
Current experiments to search for broken lepton-number symmetry through the observation of neutrinoless double-beta decay ($0\mathrm{νββ}$) provide the most stringent limits on the Majorana nature of neutrinos and the effective Majorana neutrino mass ($m_{ββ}$). The next-generation experiments will focus on the sensitivity to the $0\mathrm{νββ}$ half-life of $\mathcal{O}(10^{27}$--$10^{28}$~years$)$ and $m_{ββ}\lesssim15$~meV, which would provide complete coverage of the so-called Inverted Ordering region of the neutrino mass parameter space. By taking advantage of recent technological breakthroughs, new, future calorimetric experiments at the 1-ton scale can increase the sensitivity by at least another order of magnitude, exploring the large fraction of the parameter space that corresponds to the Normal neutrino mass ordering. In case of a discovery, such experiments could provide important insights toward a new understanding of the mechanism of $0\mathrm{νββ}$.
We present here a series of projects underway that will provide advancements in background reduction, cryogenic readout, and physics searches beyond $0\mathrm{νββ}$, all moving toward the next-to-next generation CUPID-1T detector.
△ Less
Submitted 8 April, 2022; v1 submitted 16 March, 2022;
originally announced March 2022.
-
Optimization of the first CUPID detector module
Authors:
CUPID collaboration,
A. Armatol,
C. Augier,
F. T. Avignone III,
O. Azzolini,
M. Balata,
K. Ballen,
A. S. Barabash,
G. Bari,
A. Barresi,
D. Baudin,
F. Bellini,
G. Benato,
M. Beretta,
M. Bettelli,
M. Biassoni,
J. Billard,
V. Boldrini,
A. Branca,
C. Brofferio,
C. Bucci,
J. Camilleri,
C. Capelli,
S. Capelli,
L. Cappelli
, et al. (153 additional authors not shown)
Abstract:
CUPID will be a next generation experiment searching for the neutrinoless double $β$ decay, whose discovery would establish the Majorana nature of the neutrino. Based on the experience achieved with the CUORE experiment, presently taking data at LNGS, CUPID aims to reach a background free environment by means of scintillating Li$_{2}$$^{100}$MoO$_4$ crystals coupled to light detectors. Indeed, the…
▽ More
CUPID will be a next generation experiment searching for the neutrinoless double $β$ decay, whose discovery would establish the Majorana nature of the neutrino. Based on the experience achieved with the CUORE experiment, presently taking data at LNGS, CUPID aims to reach a background free environment by means of scintillating Li$_{2}$$^{100}$MoO$_4$ crystals coupled to light detectors. Indeed, the simultaneous heat and light detection allows us to reject the dominant background of $α$ particles, as proven by the CUPID-0 and CUPID-Mo demonstrators. In this work we present the results of the first test of the CUPID baseline module. In particular, we propose a new optimized detector structure and light sensors design to enhance the engineering and the light collection, respectively. We characterized the heat detectors, achieving an energy resolution of (5.9 $\pm$ 0.2) keV FWHM at the $Q$-value of $^{100}$Mo (about 3034 keV). We studied the light collection of the baseline CUPID design with respect to an alternative configuration which features gravity-assisted light detectors' mounting. In both cases we obtained an improvement in the light collection with respect to past measures and we validated the particle identification capability of the detector, which ensures an $α$ particle rejection higher than 99.9%, fully satisfying the requirements for CUPID.
△ Less
Submitted 13 February, 2022;
originally announced February 2022.
-
Measurement of the Positive Muon Anomalous Magnetic Moment to 0.46 ppm
Authors:
B. Abi,
T. Albahri,
S. Al-Kilani,
D. Allspach,
L. P. Alonzi,
A. Anastasi,
A. Anisenkov,
F. Azfar,
K. Badgley,
S. Baeßler,
I. Bailey,
V. A. Baranov,
E. Barlas-Yucel,
T. Barrett,
E. Barzi,
A. Basti,
F. Bedeschi,
A. Behnke,
M. Berz,
M. Bhattacharya,
H. P. Binney,
R. Bjorkquist,
P. Bloom,
J. Bono,
E. Bottalico
, et al. (212 additional authors not shown)
Abstract:
We present the first results of the Fermilab Muon g-2 Experiment for the positive muon magnetic anomaly $a_μ\equiv (g_μ-2)/2$. The anomaly is determined from the precision measurements of two angular frequencies. Intensity variation of high-energy positrons from muon decays directly encodes the difference frequency $ω_a$ between the spin-precession and cyclotron frequencies for polarized muons in…
▽ More
We present the first results of the Fermilab Muon g-2 Experiment for the positive muon magnetic anomaly $a_μ\equiv (g_μ-2)/2$. The anomaly is determined from the precision measurements of two angular frequencies. Intensity variation of high-energy positrons from muon decays directly encodes the difference frequency $ω_a$ between the spin-precession and cyclotron frequencies for polarized muons in a magnetic storage ring. The storage ring magnetic field is measured using nuclear magnetic resonance probes calibrated in terms of the equivalent proton spin precession frequency ${\tildeω'^{}_p}$ in a spherical water sample at 34.7$^{\circ}$C. The ratio $ω_a / {\tildeω'^{}_p}$, together with known fundamental constants, determines $a_μ({\rm FNAL}) = 116\,592\,040(54)\times 10^{-11}$ (0.46\,ppm). The result is 3.3 standard deviations greater than the standard model prediction and is in excellent agreement with the previous Brookhaven National Laboratory (BNL) E821 measurement. After combination with previous measurements of both $μ^+$ and $μ^-$, the new experimental average of $a_μ({\rm Exp}) = 116\,592\,061(41)\times 10^{-11}$ (0.35\,ppm) increases the tension between experiment and theory to 4.2 standard deviations
△ Less
Submitted 7 April, 2021;
originally announced April 2021.
-
Measurement of the anomalous precession frequency of the muon in the Fermilab Muon g-2 experiment
Authors:
T. Albahri,
A. Anastasi,
A. Anisenkov,
K. Badgley,
S. Baeßler,
I. Bailey,
V. A. Baranov,
E. Barlas-Yucel,
T. Barrett,
A. Basti,
F. Bedeschi,
M. Berz,
M. Bhattacharya,
H. P. Binney,
P. Bloom,
J. Bono,
E. Bottalico,
T. Bowcock,
G. Cantatore,
R. M. Carey,
B. C. K. Casey,
D. Cauz,
R. Chakraborty,
S. P. Chang,
A. Chapelain
, et al. (153 additional authors not shown)
Abstract:
The Muon g-2 Experiment at Fermi National Accelerator Laboratory (FNAL) has measured the muon anomalous precession frequency $ω_a$ to an uncertainty of 434 parts per billion (ppb), statistical, and 56 ppb, systematic, with data collected in four storage ring configurations during its first physics run in 2018. When combined with a precision measurement of the magnetic field of the experiment's muo…
▽ More
The Muon g-2 Experiment at Fermi National Accelerator Laboratory (FNAL) has measured the muon anomalous precession frequency $ω_a$ to an uncertainty of 434 parts per billion (ppb), statistical, and 56 ppb, systematic, with data collected in four storage ring configurations during its first physics run in 2018. When combined with a precision measurement of the magnetic field of the experiment's muon storage ring, the precession frequency measurement determines a muon magnetic anomaly of $a_μ({\rm FNAL}) = 116\,592\,040(54) \times 10^{-11}$ (0.46 ppm). This article describes the multiple techniques employed in the reconstruction, analysis and fitting of the data to measure the precession frequency. It also presents the averaging of the results from the eleven separate determinations of ω_a, and the systematic uncertainties on the result.
△ Less
Submitted 7 April, 2021;
originally announced April 2021.
-
Magnetic Field Measurement and Analysis for the Muon g-2 Experiment at Fermilab
Authors:
T. Albahri,
A. Anastasi,
K. Badgley,
S. Baeßler,
I. Bailey,
V. A. Baranov,
E. Barlas-Yucel,
T. Barrett,
F. Bedeschi,
M. Berz,
M. Bhattacharya,
H. P. Binney,
P. Bloom,
J. Bono,
E. Bottalico,
T. Bowcock,
G. Cantatore,
R. M. Carey,
B. C. K. Casey,
D. Cauz,
R. Chakraborty,
S. P. Chang,
A. Chapelain,
S. Charity,
R. Chislett
, et al. (148 additional authors not shown)
Abstract:
The Fermi National Accelerator Laboratory has measured the anomalous precession frequency $a^{}_μ= (g^{}_μ-2)/2$ of the muon to a combined precision of 0.46 parts per million with data collected during its first physics run in 2018. This paper documents the measurement of the magnetic field in the muon storage ring. The magnetic field is monitored by nuclear magnetic resonance systems and calibrat…
▽ More
The Fermi National Accelerator Laboratory has measured the anomalous precession frequency $a^{}_μ= (g^{}_μ-2)/2$ of the muon to a combined precision of 0.46 parts per million with data collected during its first physics run in 2018. This paper documents the measurement of the magnetic field in the muon storage ring. The magnetic field is monitored by nuclear magnetic resonance systems and calibrated in terms of the equivalent proton spin precession frequency in a spherical water sample at 34.7$^\circ$C. The measured field is weighted by the muon distribution resulting in $\tildeω'^{}_p$, the denominator in the ratio $ω^{}_a$/$\tildeω'^{}_p$ that together with known fundamental constants yields $a^{}_μ$. The reported uncertainty on $\tildeω'^{}_p$ for the Run-1 data set is 114 ppb consisting of uncertainty contributions from frequency extraction, calibration, map**, tracking, and averaging of 56 ppb, and contributions from fast transient fields of 99 ppb.
△ Less
Submitted 17 June, 2022; v1 submitted 7 April, 2021;
originally announced April 2021.