-
Final Search for Short-Baseline Neutrino Oscillations with the PROSPECT-I Detector at HFIR
Authors:
M. Andriamirado,
B. Balantekin,
C. D. Bass,
O. Benevides Rodrigues,
E. P. Bernard,
N. S. Bowden,
C. D. Bryan,
R. Carr,
T. Classen,
A. J. Conant,
G. Deichert,
M. J. Dolinski,
A. Erickson,
A. Galindo-Uribarri,
S. Gokhale,
C. Grant,
S. Hans,
A. B. Hansell,
K. M. Heeger,
B. Heffron,
D. E. Jaffe,
S. Jayakumar,
J. R. Koblanski,
P. Kunkle,
C. E. Lane
, et al. (22 additional authors not shown)
Abstract:
The PROSPECT experiment is designed to perform precise searches for antineutrino disappearance at short distances (7 - 9~m) from compact nuclear reactor cores. This Letter reports results from a new neutrino oscillation analysis performed using the complete data sample from the PROSPECT-I detector operated at the High Flux Isotope Reactor in 2018. The analysis uses a multi-period selection of inve…
▽ More
The PROSPECT experiment is designed to perform precise searches for antineutrino disappearance at short distances (7 - 9~m) from compact nuclear reactor cores. This Letter reports results from a new neutrino oscillation analysis performed using the complete data sample from the PROSPECT-I detector operated at the High Flux Isotope Reactor in 2018. The analysis uses a multi-period selection of inverse beta decay neutrino interactions with reduced backgrounds and enhanced statistical power to set limits on electron-flavor disappearance caused by mixing with sterile neutrinos with 0.2 - 20 eV$^2$ mass splittings. Inverse beta decay positron energy spectra from six different reactor-detector distance ranges are found to be statistically consistent with one another, as would be expected in the absence of sterile neutrino oscillations. The data excludes at 95% confidence level the existence of sterile neutrinos in regions above 3~eV$^2$ previously unexplored by terrestrial experiments, including all space below 10~eV$^2$ suggested by the recently strengthened Gallium Anomaly. The best-fit point of the Neutrino-4 reactor experiment's claimed observation of short-baseline oscillation is ruled out at more than five standard deviations.
△ Less
Submitted 14 June, 2024;
originally announced June 2024.
-
Reactor Antineutrino Directionality Measurement with the PROSPECT-I Detector
Authors:
M. Andriamirado,
B. Balantekin,
C. D. Bass,
O. Benevides Rodrigues,
E. P. Bernard,
N. S. Bowden,
C. D. Bryan,
R. Carr,
T. Classen,
A. J. Conant,
G. Deichert,
M. J. Dolinski,
A. Erickson,
A. Galindo-Uribarri,
S. Gokhale,
C. Grant,
S. Hans,
A. B. Hansell,
K. M. Heeger,
B. Heffron,
D. E. Jaffe,
S. Jayakumar,
D. C. Jones,
J. R. Koblanski,
P. Kunkle
, et al. (24 additional authors not shown)
Abstract:
The PROSPECT-I detector has several features that enable measurement of the direction of a compact neutrino source. In this paper, a detailed report on the directional measurements made on electron antineutrinos emitted from the High Flux Isotope Reactor is presented. With an estimated true neutrino (reactor to detector) direction of $φ= 40.8\unicode{xB0} \pm 0.7\unicode{xB0}$ and…
▽ More
The PROSPECT-I detector has several features that enable measurement of the direction of a compact neutrino source. In this paper, a detailed report on the directional measurements made on electron antineutrinos emitted from the High Flux Isotope Reactor is presented. With an estimated true neutrino (reactor to detector) direction of $φ= 40.8\unicode{xB0} \pm 0.7\unicode{xB0}$ and $θ= 98.6\unicode{xB0} \pm 0.4\unicode{xB0}$, the PROSPECT-I detector is able to reconstruct an average neutrino direction of $φ= 39.4\unicode{xB0} \pm 2.9\unicode{xB0}$ and $θ= 97.6\unicode{xB0} \pm 1.6\unicode{xB0}$. This measurement is made with approximately 48000 Inverse Beta Decay signal events and is the most precise directional reconstruction of reactor antineutrinos to date.
△ Less
Submitted 11 July, 2024; v1 submitted 12 June, 2024;
originally announced June 2024.
-
Final Measurement of the U235 Antineutrino Energy Spectrum with the PROSPECT-I Detector at HFIR
Authors:
M. Adriamirado,
A. B. Balantekin,
C. D. Bass,
D. E. Bergeron,
E. P. Bernard,
N. S. Bowden,
C. D. Bryan,
R. Carr,
T. Classen,
A. J. Conant,
G. Deichert,
A. Delgado,
M. V. Diwan,
M. J. Dolinski,
A. Erickson,
B. T. Foust,
J. K. Gaison,
A. Galindo-Uribari,
C. E. Gilbert,
S. Gokhale,
C. Grant,
S. Hans,
A. B. Hansell,
K. M. Heeger,
B. Heffron
, et al. (39 additional authors not shown)
Abstract:
This Letter reports one of the most precise measurements to date of the antineutrino spectrum from a purely U235-fueled reactor, made with the final dataset from the PROSPECT-I detector at the High Flux Isotope Reactor. By extracting information from previously unused detector segments, this analysis effectively doubles the statistics of the previous PROSPECT measurement. The reconstructed energy…
▽ More
This Letter reports one of the most precise measurements to date of the antineutrino spectrum from a purely U235-fueled reactor, made with the final dataset from the PROSPECT-I detector at the High Flux Isotope Reactor. By extracting information from previously unused detector segments, this analysis effectively doubles the statistics of the previous PROSPECT measurement. The reconstructed energy spectrum is unfolded into antineutrino energy and compared with both the Huber-Mueller model and a spectrum from a commercial reactor burning multiple fuel isotopes. A local excess over the model is observed in the 5MeV to 7MeV energy region. Comparison of the PROSPECT results with those from commercial reactors provides new constraints on the origin of this excess, disfavoring at 2.2 and 3.2 standard deviations the hypotheses that antineutrinos from U235 are solely responsible and non-contributors to the excess observed at commercial reactors respectively.
△ Less
Submitted 16 August, 2023; v1 submitted 20 December, 2022;
originally announced December 2022.
-
Calibration strategy of the PROSPECT-II detector with external and intrinsic sources
Authors:
M. Andriamirado,
A. B. Balantekin,
C. D. Bass,
D. E. Bergeron,
E. P. Bernard,
N. S. Bowden,
C. D. Bryan,
R. Carr,
T. Classen,
A. J. Conant,
A. Delgado,
M. V. Diwan,
M. J. Dolinski,
A. Erickson,
B. T. Foust,
J. K. Gaison,
A. Galindo-Uribarri,
C. E. Gilbert,
S. Gokhale,
C. Grant,
S. Hans,
A. B. Hansell,
K. M. Heeger,
B. Heffron,
D. E. Jaffe
, et al. (36 additional authors not shown)
Abstract:
This paper presents an energy calibration scheme for an upgraded reactor antineutrino detector for the Precision Reactor Oscillation and Spectrum Experiment (PROSPECT). The PROSPECT collaboration is preparing an upgraded detector, PROSPECT-II (P-II), to advance capabilities for the investigation of fundamental neutrino physics, fission processes and associated reactor neutrino flux, and nuclear se…
▽ More
This paper presents an energy calibration scheme for an upgraded reactor antineutrino detector for the Precision Reactor Oscillation and Spectrum Experiment (PROSPECT). The PROSPECT collaboration is preparing an upgraded detector, PROSPECT-II (P-II), to advance capabilities for the investigation of fundamental neutrino physics, fission processes and associated reactor neutrino flux, and nuclear security applications. P-II will expand the statistical power of the original PROSPECT (P-I) dataset by at least an order of magnitude. The new design builds upon previous P-I design and focuses on improving the detector robustness and long-term stability to enable multi-year operation at one or more sites. The new design optimizes the fiducial volume by elimination of dead space previously occupied by internal calibration channels, which in turn necessitates the external deployment. In this paper, we describe a calibration strategy for P-II. The expected performance of externally deployed calibration sources is evaluated using P-I data and a well-benchmarked simulation package by varying detector segmentation configurations in the analysis. The proposed external calibration scheme delivers a compatible energy scale model and achieves comparable performance with the inclusion of an additional AmBe neutron source, in comparison to the previous internal arrangement. Most importantly, the estimated uncertainty contribution from the external energy scale calibration model meets the precision requirements of the P-II experiment.
△ Less
Submitted 10 April, 2023; v1 submitted 17 November, 2022;
originally announced November 2022.
-
Physics Opportunities with PROSPECT-II
Authors:
M. Andriamirado,
A. B. Balantekin,
C. D. Bass,
D. E. Bergeron,
E. Bernard,
N. S. Bowden,
C. D. Bryan,
R. Carr,
T. Classen,
A. J. Conant,
G. Deichert,
A. Delgado,
M. V. Diwan,
M. J. Dolinski,
A. Erickson,
B. T. Foust,
J. K. Gaison,
A. Galindo-Uribari,
C. E. Gilbert,
S. Gokhale,
C. Grant,
S. Hans,
A. B. Hansell,
K. M. Heeger,
B. Heffron
, et al. (39 additional authors not shown)
Abstract:
The PROSPECT experiment has substantially addressed the original 'Reactor Antineutrino Anomaly' by performing a high-resolution spectrum measurement from an enriched compact reactor core and a reactor model-independent sterile neutrino oscillation search based on the unique spectral distortions the existence of eV$^2$-scale sterile neutrinos would impart. But as the field has evolved, the current…
▽ More
The PROSPECT experiment has substantially addressed the original 'Reactor Antineutrino Anomaly' by performing a high-resolution spectrum measurement from an enriched compact reactor core and a reactor model-independent sterile neutrino oscillation search based on the unique spectral distortions the existence of eV$^2$-scale sterile neutrinos would impart. But as the field has evolved, the current short-baseline (SBL) landscape supports many complex phenomenological interpretations, establishing a need for complementary experimental approaches to resolve the situation.
While the global suite of SBL reactor experiments, including PROSPECT, have probed much of the sterile neutrino parameter space, there remains a large region above 1 eV$^2$ that remains unaddressed. Recent results from BEST confirm the Gallium Anomaly, increasing its significance to $\sim 5σ$, with sterile neutrinos providing a possible explanation of this anomaly. Separately, the MicroBooNE exclusion of electron-like signatures causing the MiniBooNE low-energy excess does not eliminate the possibility of sterile neutrinos as an explanation. Focusing specifically on the future use of reactors as a neutrino source for beyond-the-standard-model physics and applications, higher-precision spectral measurements still have a role to play.
These recent results have created a confusing landscape which requires new data to disentangle the seemingly contradictory measurements. To directly probe $\overlineν_{e}$ disappearance from high $Δm^2$ sterile neutrinos, the PROSPECT collaboration proposes to build an upgraded and improved detector, PROSPECT-II. It features an evolutionary detector design which can be constructed and deployed within one year and have impactful physics with as little as one calendar year of data.
△ Less
Submitted 14 July, 2022; v1 submitted 24 February, 2022;
originally announced February 2022.
-
Nu Tools: Exploring Practical Roles for Neutrinos in Nuclear Energy and Security
Authors:
Oluwatomi Akindele,
Nathaniel Bowden,
Rachel Carr,
Andrew Conant,
Milind Diwan,
Anna Erickson,
Michael Foxe,
Bethany L. Goldblum,
Patrick Huber,
Igor Jovanovic,
Jonathan Link,
Bryce Littlejohn,
Pieter Mumm,
Jason Newby
Abstract:
For decades, physicists have used neutrinos from nuclear reactors to advance basic science. These pursuits have inspired many ideas for application of neutrino detectors in nuclear energy and security. While developments in neutrino detectors are now making some of these ideas technically feasible, their value in the context of real needs and constraints has been unclear. This report seeks to help…
▽ More
For decades, physicists have used neutrinos from nuclear reactors to advance basic science. These pursuits have inspired many ideas for application of neutrino detectors in nuclear energy and security. While developments in neutrino detectors are now making some of these ideas technically feasible, their value in the context of real needs and constraints has been unclear. This report seeks to help focus the picture of where neutrino technology may find practical roles in nuclear energy and security.
This report is the final product of the Nu Tools study, commissioned in 2019 by the DOE National Nuclear Security Administration (NNSA) Office of Defense Nuclear Nonproliferation Research and Development (DNN R&D). The study was conducted over two years by a group of neutrino physicists and nuclear engineers. A central theme of the study and this report is that useful application of neutrinos will depend not only on advancing physics and technology but also on understanding the needs and constraints of potential end-users.
The Study Approach emphasized broad end-user engagement. The major effort, undertaken from May to December 2020, was a series of engagements with the wider nuclear energy and security communities. Interviews with 41 experts revealed points of common understanding, which this report captures in three Cross-Cutting Findings, a Framework for Evaluating Utility, and seven Use Case Findings. The report concludes with two Recommendations. The findings and recommendations are summarized below. The respective ordering within each category does not represent a prioritization or implied value judgement.
△ Less
Submitted 20 December, 2021;
originally announced December 2021.
-
PROSPECT-II Physics Opportunities
Authors:
M. Andriamirado,
A. B. Balantekin,
H. R. Band,
C. D. Bass,
D. E. Bergeron,
N. S. Bowden,
C. D. Bryan,
R. Carr,
T. Classen,
A. J. Conant,
G. Deichert,
A. Delgado,
M. V. Diwan,
M. J. Dolinski,
A. Erickson,
B. T. Foust,
J. K. Gaison,
A. Galindo-Uribari,
C. E. Gilbert,
C. Grant,
S. Hans,
A. B. Hansell,
K. M. Heeger,
B. Heffron,
D. E. Jaffe
, et al. (37 additional authors not shown)
Abstract:
The Precision Reactor Oscillation and Spectrum Experiment, PROSPECT, has made world-leading measurements of reactor antineutrinos at short baselines. In its first phase, conducted at the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory, PROSPECT produced some of the strongest limits on eV-scale sterile neutrinos, made a precision measurement of the reactor antineutrino spectrum fr…
▽ More
The Precision Reactor Oscillation and Spectrum Experiment, PROSPECT, has made world-leading measurements of reactor antineutrinos at short baselines. In its first phase, conducted at the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory, PROSPECT produced some of the strongest limits on eV-scale sterile neutrinos, made a precision measurement of the reactor antineutrino spectrum from $^{235}$U, and demonstrated the observation of reactor antineutrinos in an aboveground detector with good energy resolution and well-controlled backgrounds. The PROSPECT collaboration is now preparing an upgraded detector, PROSPECT-II, to probe yet unexplored parameter space for sterile neutrinos and contribute to a full resolution of the Reactor Antineutrino Anomaly, a longstanding puzzle in neutrino physics. By pressing forward on the world's most precise measurement of the $^{235}$U antineutrino spectrum and measuring the absolute flux of antineutrinos from $^{235}$U, PROSPECT-II will sharpen a tool with potential value for basic neutrino science, nuclear data validation, and nuclear security applications. Following a two-year deployment at HFIR, an additional PROSPECT-II deployment at a low enriched uranium reactor could make complementary measurements of the neutrino yield from other fission isotopes. PROSPECT-II provides a unique opportunity to continue the study of reactor antineutrinos at short baselines, taking advantage of demonstrated elements of the original PROSPECT design and close access to a highly enriched uranium reactor core.
△ Less
Submitted 3 September, 2022; v1 submitted 8 July, 2021;
originally announced July 2021.
-
Antineutrino Detectors Remain Impractical for Nuclear Explosion Monitoring
Authors:
Michael Foxe,
Theodore Bowyer,
Rachel Carr,
John Orrell,
Brent VanDevender
Abstract:
Fission explosions produce large numbers of antineutrinos. It is occasionally asked whether this distinctive, unshieldable emission could help reveal clandestine nuclear weapon explosions. The practical challenge encountered is that detectors large enough for this application are cost prohibitive, likely on the multi-billion-dollar scale. In this paper, we review several hypothetical use cases for…
▽ More
Fission explosions produce large numbers of antineutrinos. It is occasionally asked whether this distinctive, unshieldable emission could help reveal clandestine nuclear weapon explosions. The practical challenge encountered is that detectors large enough for this application are cost prohibitive, likely on the multi-billion-dollar scale. In this paper, we review several hypothetical use cases for antineutrino detectors as supplements to the seismic, infrasound, hydroacoustic, and airborne radionuclide sensors of the Comprehensive Nuclear-Test-Ban Treaty Organization's International Monitoring System. In each case, if an anti-neutrino detector could be constructed that would compete with existing capabilities, we conclude that the cost would considerably outstrip the value it might add to the existing monitoring network, compared to the significantly lower costs for the same or superior capability.
△ Less
Submitted 27 March, 2020;
originally announced May 2020.
-
Improved limits on Fierz Interference using asymmetry measurements from the UCNA experiment
Authors:
Xuan Sun,
E. Adamek,
B. Allgeier,
Y. Bagdasarova,
D. B. Berguno,
M. Blatnik,
T. J. Bowles,
L. J. Broussard,
M. A. -P. Brown,
R. Carr,
S. Clayton,
C. Cude-Woods,
S. Currie,
E. B. Dees,
X. Ding,
B. W. Filippone,
A. García,
P. Geltenbort,
S. Hasan,
K. P. Hickerson,
J. Hoagland,
R. Hong,
A. T. Holley,
T. M. Ito,
A. Knecht
, et al. (34 additional authors not shown)
Abstract:
The Ultracold Neutron Asymmetry (UCNA) experiment was designed to measure the $β$-decay asymmetry parameter, $A_0$, for free neutron decay. In the experiment, polarized ultracold neutrons are transported into a decay trap, and their $β$-decay electrons are detected with $\approx 4π$ acceptance into two detector packages which provide position and energy reconstruction. The experiment also has sens…
▽ More
The Ultracold Neutron Asymmetry (UCNA) experiment was designed to measure the $β$-decay asymmetry parameter, $A_0$, for free neutron decay. In the experiment, polarized ultracold neutrons are transported into a decay trap, and their $β$-decay electrons are detected with $\approx 4π$ acceptance into two detector packages which provide position and energy reconstruction. The experiment also has sensitivity to $b_{n}$, the Fierz interference term in the neutron $β$-decay rate. In this work, we determine $b_{n}$ from the energy dependence of $A_0$ using the data taken during the UCNA 2011-2013 run. In addition, we present the same type of analysis using the earlier 2010 $A$ dataset. Motivated by improved statistics and comparable systematic errors compared to the 2010 data-taking run, we present a new $b_{n}$ measurement using the weighted average of our asymmetry dataset fits, to obtain $b_{n} = 0.066 \pm 0.041_{\text{stat}} \pm 0.024_{\text{syst}}$ which corresponds to a limit of $-0.012 < b_{n} < 0.144$ at the 90% confidence level.
△ Less
Submitted 13 November, 2019;
originally announced November 2019.
-
A New Cryogenic Apparatus to Search for the Neutron Electric Dipole Moment
Authors:
M. W. Ahmed,
R. Alarcon,
A. Aleksandrova,
S. Baessler,
L. Barron-Palos,
L. M. Bartoszek,
D. H. Beck,
M. Behzadipour,
I. Berkutov,
J. Bessuille,
M. Blatnik,
M. Broering,
L. J. Broussard,
M. Busch,
R. Carr,
V. Cianciolo,
S. M. Clayton,
M. D. Cooper,
C. Crawford,
S. A. Currie,
C. Daurer,
R. Dipert,
K. Dow,
D. Dutta,
Y. Efremenko
, et al. (69 additional authors not shown)
Abstract:
A cryogenic apparatus is described that enables a new experiment, nEDM@SNS, with a major improvement in sensitivity compared to the existing limit in the search for a neutron Electric Dipole Moment (EDM). It uses superfluid $^4$He to produce a high density of Ultra-Cold Neutrons (UCN) which are contained in a suitably coated pair of measurement cells. The experiment, to be operated at the Spallati…
▽ More
A cryogenic apparatus is described that enables a new experiment, nEDM@SNS, with a major improvement in sensitivity compared to the existing limit in the search for a neutron Electric Dipole Moment (EDM). It uses superfluid $^4$He to produce a high density of Ultra-Cold Neutrons (UCN) which are contained in a suitably coated pair of measurement cells. The experiment, to be operated at the Spallation Neutron Source at Oak Ridge National Laboratory, uses polarized $^3$He from an Atomic Beam Source injected into the superfluid $^4$He and transported to the measurement cells as a co-magnetometer. The superfluid $^4$He is also used as an insulating medium allowing significantly higher electric fields, compared to previous experiments, to be maintained across the measurement cells. These features provide an ultimate statistical uncertainty for the EDM of $2-3\times 10^{-28}$ e-cm, with anticipated systematic uncertainties below this level.
△ Less
Submitted 20 November, 2019; v1 submitted 26 August, 2019;
originally announced August 2019.
-
Final results for the neutron $β$-asymmetry parameter $A_0$ from the UCNA experiment
Authors:
B. Plaster,
E. Adamek,
B. Allgeier,
J. Anaya,
H. O. Back,
Y. Bagdasarova,
D. B. Berguno,
M. Blatnik,
J. G. Boissevain,
T. J. Bowles,
L. J. Broussard,
M. A. -P. Brown,
R. Carr,
D. J. Clark,
S. Clayton,
C. Cude-Woods,
S. Currie,
E. B. Dees,
X. Ding,
S. Du,
B. W. Filippone,
A. Garcia,
P. Geltenbort,
S. Hasan,
A. Hawari
, et al. (69 additional authors not shown)
Abstract:
The UCNA experiment was designed to measure the neutron $β$-asymmetry parameter $A_0$ using polarized ultracold neutrons (UCN). UCN produced via downscattering in solid deuterium were polarized via transport through a 7 T magnetic field, and then directed to a 1 T solenoidal electron spectrometer, where the decay electrons were detected in electron detector packages located on the two ends of the…
▽ More
The UCNA experiment was designed to measure the neutron $β$-asymmetry parameter $A_0$ using polarized ultracold neutrons (UCN). UCN produced via downscattering in solid deuterium were polarized via transport through a 7 T magnetic field, and then directed to a 1 T solenoidal electron spectrometer, where the decay electrons were detected in electron detector packages located on the two ends of the spectrometer. A value for $A_0$ was then extracted from the asymmetry in the numbers of counts in the two detector packages. We summarize all of the results from the UCNA experiment, obtained during run periods in 2007, 2008--2009, 2010, and 2011--2013, which ultimately culminated in a 0.67\% precision result for $A_0$.
△ Less
Submitted 10 April, 2019;
originally announced April 2019.
-
The neutron electric dipole moment experiment at the Spallation Neutron Source
Authors:
K. K. H. Leung,
M. Ahmed,
R. Alarcon,
A. Aleksandrova,
S. Baeßler,
L. Barrón-Palos,
L. Bartoszek,
D. H. Beck,
M. Behzadipour,
J. Bessuille,
M. A. Blatnik,
M. Broering,
L. J. Broussard,
M. Busch,
R. Carr,
P. -H. Chu,
V. Cianciolo,
S. M. Clayton,
M. D. Cooper,
C. Crawford,
S. A. Currie,
C. Daurer,
R. Dipert,
K. Dow,
D. Dutta
, et al. (68 additional authors not shown)
Abstract:
Novel experimental techniques are required to make the next big leap in neutron electric dipole moment experimental sensitivity, both in terms of statistics and systematic error control. The nEDM experiment at the Spallation Neutron Source (nEDM@SNS) will implement the scheme of Golub & Lamoreaux [Phys. Rep., 237, 1 (1994)]. The unique properties of combining polarized ultracold neutrons, polarize…
▽ More
Novel experimental techniques are required to make the next big leap in neutron electric dipole moment experimental sensitivity, both in terms of statistics and systematic error control. The nEDM experiment at the Spallation Neutron Source (nEDM@SNS) will implement the scheme of Golub & Lamoreaux [Phys. Rep., 237, 1 (1994)]. The unique properties of combining polarized ultracold neutrons, polarized $^3$He, and superfluid $^4$He will be exploited to provide a sensitivity to $\sim 10^{-28}\,e{\rm \,\cdot\, cm}$. Our cryogenic apparatus will deploy two small ($3\,{\rm L}$) measurement cells with a high density of ultracold neutrons produced and spin analyzed in situ. The electric field strength, precession time, magnetic shielding, and detected UCN number will all be enhanced compared to previous room temperature Ramsey measurements. Our $^3$He co-magnetometer offers unique control of systematic effects, in particular the Bloch-Siegert induced false EDM. Furthermore, there will be two distinct measurement modes: free precession and dressed spin. This will provide an important self-check of our results. Following five years of "critical component demonstration," our collaboration transitioned to a "large scale integration" phase in 2018. An overview of our measurement techniques, experimental design, and brief updates are described in these proceedings.
△ Less
Submitted 4 October, 2019; v1 submitted 6 March, 2019;
originally announced March 2019.
-
Rejecting cosmic background for exclusive neutrino interaction studies with Liquid Argon TPCs; a case study with the MicroBooNE detector
Authors:
MicroBooNE collaboration,
C. Adams,
M. Alrashed,
R. An,
J. Anthony,
J. Asaadi,
A. Ashkenazi,
M. Auger,
S. Balasubramanian,
B. Baller,
C. Barnes,
G. Barr,
M. Bass,
F. Bay,
A. Bhat,
K. Bhattacharya,
M. Bishai,
A. Blake,
T. Bolton,
L. Camilleri,
D. Caratelli,
I. Caro Terrazas,
R. Carr,
R. Castillo Fernandez,
F. Cavanna
, et al. (150 additional authors not shown)
Abstract:
Cosmic ray (CR) interactions can be a challenging source of background for neutrino oscillation and cross-section measurements in surface detectors. We present methods for CR rejection in measurements of charged-current quasielastic-like (CCQE-like) neutrino interactions, with a muon and a proton in the final state, measured using liquid argon time projection chambers (LArTPCs). Using a sample of…
▽ More
Cosmic ray (CR) interactions can be a challenging source of background for neutrino oscillation and cross-section measurements in surface detectors. We present methods for CR rejection in measurements of charged-current quasielastic-like (CCQE-like) neutrino interactions, with a muon and a proton in the final state, measured using liquid argon time projection chambers (LArTPCs). Using a sample of cosmic data collected with the MicroBooNE detector, mixed with simulated neutrino scattering events, a set of event selection criteria is developed that produces an event sample with minimal contribution from CR background. Depending on the selection criteria used a purity between 50% and 80% can be achieved with a signal selection efficiency between 50% and 25%, with higher purity coming at the expense of lower efficiency. While using a specific dataset from the MicroBooNE detector and selection criteria values optimized for CCQE-like events, the concepts presented here are generic and can be adapted for various studies of exclusive νμ interactions in LArTPCs.
△ Less
Submitted 2 January, 2019; v1 submitted 9 December, 2018;
originally announced December 2018.
-
Ionization Electron Signal Processing in Single Phase LArTPCs II. Data/Simulation Comparison and Performance in MicroBooNE
Authors:
MicroBooNE collaboration,
C. Adams,
R. An,
J. Anthony,
J. Asaadi,
M. Auger,
S. Balasubramanian,
B. Baller,
C. Barnes,
G. Barr,
M. Bass,
F. Bay,
A. Bhat,
K. Bhattacharya,
M. Bishai,
A. Blake,
T. Bolton,
L. Camilleri,
D. Caratelli,
R. Carr,
I. Caro Terrazas,
R. Castillo Fernandez,
F. Cavanna,
G. Cerati,
H. Chen
, et al. (146 additional authors not shown)
Abstract:
The single-phase liquid argon time projection chamber (LArTPC) provides a large amount of detailed information in the form of fine-grained drifted ionization charge from particle traces. To fully utilize this information, the deposited charge must be accurately extracted from the raw digitized waveforms via a robust signal processing chain. Enabled by the ultra-low noise levels associated with cry…
▽ More
The single-phase liquid argon time projection chamber (LArTPC) provides a large amount of detailed information in the form of fine-grained drifted ionization charge from particle traces. To fully utilize this information, the deposited charge must be accurately extracted from the raw digitized waveforms via a robust signal processing chain. Enabled by the ultra-low noise levels associated with cryogenic electronics in the MicroBooNE detector, the precise extraction of ionization charge from the induction wire planes in a single-phase LArTPC is qualitatively demonstrated on MicroBooNE data with event display images, and quantitatively demonstrated via waveform-level and track-level metrics. Improved performance of induction plane calorimetry is demonstrated through the agreement of extracted ionization charge measurements across different wire planes for various event topologies. In addition to the comprehensive waveform-level comparison of data and simulation, a calibration of the cryogenic electronics response is presented and solutions to various MicroBooNE-specific TPC issues are discussed. This work presents an important improvement in LArTPC signal processing, the foundation of reconstruction and therefore physics analyses in MicroBooNE.
△ Less
Submitted 11 June, 2018; v1 submitted 7 April, 2018;
originally announced April 2018.
-
Search for dark matter decay of the free neutron from the UCNA experiment: n $\rightarrow χ+ e^+e^-$
Authors:
X. Sun,
E. Adamek,
B. Allgeier,
M. Blatnik,
T. J. Bowles,
L. J. Broussard,
M. A. -P. Brown,
R. Carr,
S. Clayton,
C. Cude-Woods,
S. Currie,
E. B. Dees,
X. Ding,
B. W. Filippone,
A. García,
P. Geltenbort,
S. Hasan,
K. P. Hickerson,
J. Hoagland,
R. Hong,
G. E. Hogan,
A. T. Holley,
T. M. Ito,
A. Knecht,
C. -Y. Liu
, et al. (35 additional authors not shown)
Abstract:
It has been proposed recently that a previously unobserved neutron decay branch to a dark matter particle ($χ$) could account for the discrepancy in the neutron lifetime observed in experiments that use two different measurement techniques. One of the possible final states discussed includes a single $χ$ along with an $e^{+}e^{-}$ pair. We use data from the UCNA (Ultracold Neutron Asymmetry) exper…
▽ More
It has been proposed recently that a previously unobserved neutron decay branch to a dark matter particle ($χ$) could account for the discrepancy in the neutron lifetime observed in experiments that use two different measurement techniques. One of the possible final states discussed includes a single $χ$ along with an $e^{+}e^{-}$ pair. We use data from the UCNA (Ultracold Neutron Asymmetry) experiment to set limits on this decay channel. Coincident electron-like events are detected with $\sim 4π$ acceptance using a pair of detectors that observe a volume of stored Ultracold Neutrons (UCNs). The summed kinetic energy ($E_{e^{+}e^{-}}$) from such events is used to set limits, as a function of the $χ$ mass, on the branching fraction for this decay channel. For $χ$ masses consistent with resolving the neutron lifetime discrepancy, we exclude this as the dominant dark matter decay channel at $\gg~5σ$ level for $100~\text{keV} < E_{e^{+}e^{-}} < 644~\text{keV}$. If the $χ+e^{+}e^{-}$ final state is not the only one, we set limits on its branching fraction of $< 10^{-4}$ for the above $E_{e^{+}e^{-}}$ range at $> 90\%$ confidence level.
△ Less
Submitted 28 March, 2018;
originally announced March 2018.
-
Sensitivity of seismically cued antineutrino detectors to nuclear explosions
Authors:
Rachel Carr,
Ferenc Dalnoki-Veress,
Adam Bernstein
Abstract:
We evaluate the sensitivity of large, gadolinium-doped water detectors to antineutrinos released by nuclear fission explosions, using updated signal and background models and taking advantage of the capacity for seismic observations to provide an analysis trigger. Under certain realistic conditions, the antineutrino signature of a 250-kiloton pure fission explosion could be identified several hund…
▽ More
We evaluate the sensitivity of large, gadolinium-doped water detectors to antineutrinos released by nuclear fission explosions, using updated signal and background models and taking advantage of the capacity for seismic observations to provide an analysis trigger. Under certain realistic conditions, the antineutrino signature of a 250-kiloton pure fission explosion could be identified several hundred kilometers away in a detector about the size of the largest module currently proposed for a basic physics experiment. In principle, such an observation could provide rapid confirmation that the seismic signal coincided with a fission event, possibly useful for international monitoring of nuclear weapon tests. We discuss the limited potential for seismically cued antineutrino observations to constrain fission yield, differentiate pure fission from fusion-enhanced weapon tests, indicate that the seismic evidence of an explosion had been intentionally masked, or verify the absence of explosive testing in a targeted area. We conclude that advances in seismic monitoring and neutrino physics have made the detection of explosion-derived antineutrinos more conceivable than previously asserted, but the size and cost of sufficiently sensitive detectors continue to limit applications.
△ Less
Submitted 11 September, 2018; v1 submitted 11 December, 2017;
originally announced December 2017.
-
New result for the neutron $β$-asymmetry parameter $A_0$ from UCNA
Authors:
M. A. -P. Brown,
E. B. Dees,
E. Adamek,
B. Allgeier,
M. Blatnik,
T. J. Bowles,
L. J. Broussard,
R. Carr,
S. Clayton,
C. Cude-Woods,
S. Currie,
X. Ding,
B. W. Filippone,
A. Garcia,
P. Geltenbort,
S. Hasan,
K. P. Hickerson,
J. Hoagland,
R. Hong,
G. E. Hogan,
A. T. Holley,
T. M. Ito,
A. Knecht,
C. -Y. Liu,
J. Liu
, et al. (34 additional authors not shown)
Abstract:
The neutron $β$-decay asymmetry parameter $A_0$ defines the correlation between the spin of the neutron and the momentum of the emitted electron, which determines $λ=\frac{g_{A}}{g_{V}}$, the ratio of the axial-vector to vector weak coupling constants. The UCNA Experiment, located at the Ultracold Neutron facility at the Los Alamos Neutron Science Center, is the first to measure such a correlation…
▽ More
The neutron $β$-decay asymmetry parameter $A_0$ defines the correlation between the spin of the neutron and the momentum of the emitted electron, which determines $λ=\frac{g_{A}}{g_{V}}$, the ratio of the axial-vector to vector weak coupling constants. The UCNA Experiment, located at the Ultracold Neutron facility at the Los Alamos Neutron Science Center, is the first to measure such a correlation coefficient using ultracold neutrons (UCN). Following improvements to the systematic uncertainties and increased statistics, we report the new result $A_0 = -0.12054(44)_{\mathrm{stat}}(68)_{\mathrm{syst}}$ which yields $λ\equiv \frac{g_{A}}{g_{V}}=-1.2783(22)$. Combination with the previous UCNA result and accounting for correlated systematic uncertainties produces $A_0=-0.12015(34)_{\mathrm{stat}}(63)_{\mathrm{syst}}$ and $λ\equiv \frac{g_{A}}{g_{V}}=-1.2772(20)$.
△ Less
Submitted 14 August, 2018; v1 submitted 3 December, 2017;
originally announced December 2017.
-
First direct constraints on Fierz interference in free neutron $β$ decay
Authors:
K. P. Hickerson,
X. Sun,
Y. Bagdasarova,
D. Bravo-Berguño,
L. J. Broussard,
M. A. -P. Brown,
R. Carr,
S. Currie,
X. Ding,
B. W. Filippone,
A. García,
P. Geltenbort,
J. Hoagland,
A. T. Holley,
R. Hong,
T. M. Ito,
A. Knecht,
C. -Y. Liu,
J. L. Liu,
M. Makela,
R. R. Mammei,
J. W. Martin,
D. Melconian,
M. P. Mendenhall,
S. D. Moore
, et al. (18 additional authors not shown)
Abstract:
Precision measurements of free neutron $β$-decay have been used to precisely constrain our understanding of the weak interaction. However the neutron Fierz interference term $b_n$, which is particularly sensitive to Beyond-Standard-Model tensor currents at the TeV scale, has thus far eluded measurement. Here we report the first direct constraints on this term, finding…
▽ More
Precision measurements of free neutron $β$-decay have been used to precisely constrain our understanding of the weak interaction. However the neutron Fierz interference term $b_n$, which is particularly sensitive to Beyond-Standard-Model tensor currents at the TeV scale, has thus far eluded measurement. Here we report the first direct constraints on this term, finding $b_n = 0.067 \pm 0.005_{\text{stat}} {}^{+0.090}_{- 0.061}{}_{\text{sys}}$, consistent with the Standard Model. The uncertainty is dominated by absolute energy reconstruction and the linearity of the beta spectrometer energy response.
△ Less
Submitted 8 July, 2017; v1 submitted 3 July, 2017;
originally announced July 2017.
-
Cryogenic magnetic coil and superconducting magnetic shield for neutron electric dipole moment searches
Authors:
S. Slutsky,
C. M. Swank,
A. Biswas,
R. Carr,
J. Escribano,
B. W. Filippone,
W. C. Griffith,
M. Mendenhall,
N. Nouri,
C. Osthelder,
A. Pérez Galván,
R. Picker,
B. Plaster
Abstract:
A magnetic coil operated at cryogenic temperatures is used to produce spatial, relative field gradients below 6 ppm/cm, stable for several hours. The apparatus is a prototype of the magnetic components for a neutron electric dipole moment (nEDM) search, which will take place at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory using ultra-cold neutrons (UCN). That search require…
▽ More
A magnetic coil operated at cryogenic temperatures is used to produce spatial, relative field gradients below 6 ppm/cm, stable for several hours. The apparatus is a prototype of the magnetic components for a neutron electric dipole moment (nEDM) search, which will take place at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory using ultra-cold neutrons (UCN). That search requires a uniform magnetic field to mitigate systematic effects and obtain long polarization lifetimes for neutron spin precession measurements. This paper details upgrades to a previously described apparatus, particularly the introduction of super-conducting magnetic shielding and the associated cryogenic apparatus. The magnetic gradients observed are sufficiently low for the nEDM search at SNS.
△ Less
Submitted 20 June, 2017; v1 submitted 10 January, 2017;
originally announced January 2017.
-
Coherent Neutrino Scattering with Low Temperature Bolometers at Chooz Reactor Complex
Authors:
J. Billard,
R. Carr,
J. Dawson,
E. Figueroa-Feliciano,
J. A. Formaggio,
J. Gascon,
M. De Jesus,
J. Johnston,
T. Lasserre,
A. Leder,
K. J. Palladino,
S. H. Trowbridge,
M. Vivier,
L. Winslow
Abstract:
We present the potential sensitivity of a future recoil detector for a first detection of the process of coherent elastic neutrino nucleus scattering (CE$ν$NS). We use the Chooz reactor complex in France as our luminous source of reactor neutrinos. Leveraging the ability to cleanly separate the rate correlated with the reactor thermal power against (uncorrelated) backgrounds, we show that a 10 kil…
▽ More
We present the potential sensitivity of a future recoil detector for a first detection of the process of coherent elastic neutrino nucleus scattering (CE$ν$NS). We use the Chooz reactor complex in France as our luminous source of reactor neutrinos. Leveraging the ability to cleanly separate the rate correlated with the reactor thermal power against (uncorrelated) backgrounds, we show that a 10 kilogram cryogenic bolometric array with 100 eV threshold should be able to extract a CE$ν$NS signal within one year of running.
△ Less
Submitted 20 September, 2017; v1 submitted 25 December, 2016;
originally announced December 2016.
-
Muon capture on light isotopes in Double Chooz
Authors:
Double Chooz collaboration,
Y. Abe,
T. Abrahão,
H. Almazan,
C. Alt,
S. Appel,
J. C. Barriere,
E. Baussan,
I. Bekman,
M. Bergevin,
T. J. C. Bezerra,
L. Bezrukov,
E. Blucher,
T. Brugière,
C. Buck,
J. Busenitz,
A. Cabrera,
L. Camilleri,
R. Carr,
M. Cerrada,
E. Chauveau,
P. Chimenti,
A. P. Collin,
E. Conover,
J. M. Conrad
, et al. (122 additional authors not shown)
Abstract:
Using the Double Chooz detector, designed to measure the neutrino mixing angle $θ_{13}$, the products of $μ^-$ capture on $^{12}$C, $^{13}$C, $^{14}$N and $^{16}$O have been measured. Over a period of 489.5 days, $2.3\times10^6$ stop** cosmic $μ^-$ have been collected, of which $1.8\times10^5$ captured on carbon, nitrogen, or oxygen nuclei in the inner detector scintillator or acrylic vessels. T…
▽ More
Using the Double Chooz detector, designed to measure the neutrino mixing angle $θ_{13}$, the products of $μ^-$ capture on $^{12}$C, $^{13}$C, $^{14}$N and $^{16}$O have been measured. Over a period of 489.5 days, $2.3\times10^6$ stop** cosmic $μ^-$ have been collected, of which $1.8\times10^5$ captured on carbon, nitrogen, or oxygen nuclei in the inner detector scintillator or acrylic vessels. The resulting isotopes were tagged using prompt neutron emission (when applicable), the subsequent beta decays, and, in some cases, $β$-delayed neutrons. The most precise measurement of the rate of $^{12}\mathrm C(μ^-,ν)^{12}\mathrm B$ to date is reported: $6.57^{+0.11}_{-0.21}\times10^{3}\,\mathrm s^{-1}$, or $(17.35^{+0.35}_{-0.59})\%$ of nuclear captures. By tagging excited states emitting gammas, the ground state transition rate to $^{12}$B has been determined to be $5.68^{+0.14}_{-0.23}\times10^3\,\mathrm s^{-1}$. The heretofore unobserved reactions $^{12}\mathrm C(μ^-,να)^{8}\mathrm{Li}$, $^{13}\mathrm C(μ^-,ν\mathrm nα)^{8}\mathrm{Li}$, and $^{13}\mathrm C(μ^-,ν\mathrm n)^{12}\mathrm B$ are measured. Further, a population of $β$n decays following stop** muons is identified with $5.5σ$ significance. Statistics limit our ability to identify these decays definitively. Assuming negligible production of $^{8}$He, the reaction $^{13}\mathrm C(μ^-,να)^{9}\mathrm{Li}$ is found to be present at the $2.7σ$ level. Limits are set on a variety of other processes.
△ Less
Submitted 17 May, 2016; v1 submitted 23 December, 2015;
originally announced December 2015.
-
A prototype vector magnetic field monitoring system for a neutron electric dipole moment experiment
Authors:
N. Nouri,
A. Biswas,
M. A. Brown,
R. Carr,
B. Filippone,
C. Osthelder,
B. Plaster,
S. Slutsky,
C. Swank
Abstract:
We present results from a first demonstration of a magnetic field monitoring system for a neutron electric dipole moment experiment. The system is designed to reconstruct the vector components of the magnetic field in the interior measurement region solely from exterior measurements.
We present results from a first demonstration of a magnetic field monitoring system for a neutron electric dipole moment experiment. The system is designed to reconstruct the vector components of the magnetic field in the interior measurement region solely from exterior measurements.
△ Less
Submitted 10 November, 2015; v1 submitted 17 August, 2015;
originally announced August 2015.
-
The Intermediate Neutrino Program
Authors:
C. Adams,
J. R. Alonso,
A. M. Ankowski,
J. A. Asaadi,
J. Ashenfelter,
S. N. Axani,
K. Babu,
C. Backhouse,
H. R. Band,
P. S. Barbeau,
N. Barros,
A. Bernstein,
M. Betancourt,
M. Bishai,
E. Blucher,
J. Bouffard,
N. Bowden,
S. Brice,
C. Bryan,
L. Camilleri,
J. Cao,
J. Carlson,
R. E. Carr,
A. Chatterjee,
M. Chen
, et al. (164 additional authors not shown)
Abstract:
The US neutrino community gathered at the Workshop on the Intermediate Neutrino Program (WINP) at Brookhaven National Laboratory February 4-6, 2015 to explore opportunities in neutrino physics over the next five to ten years. Scientists from particle, astroparticle and nuclear physics participated in the workshop. The workshop examined promising opportunities for neutrino physics in the intermedia…
▽ More
The US neutrino community gathered at the Workshop on the Intermediate Neutrino Program (WINP) at Brookhaven National Laboratory February 4-6, 2015 to explore opportunities in neutrino physics over the next five to ten years. Scientists from particle, astroparticle and nuclear physics participated in the workshop. The workshop examined promising opportunities for neutrino physics in the intermediate term, including possible new small to mid-scale experiments, US contributions to large experiments, upgrades to existing experiments, R&D plans and theory. The workshop was organized into two sets of parallel working group sessions, divided by physics topics and technology. Physics working groups covered topics on Sterile Neutrinos, Neutrino Mixing, Neutrino Interactions, Neutrino Properties and Astrophysical Neutrinos. Technology sessions were organized into Theory, Short-Baseline Accelerator Neutrinos, Reactor Neutrinos, Detector R&D and Source, Cyclotron and Meson Decay at Rest sessions.This report summarizes discussion and conclusions from the workshop.
△ Less
Submitted 1 April, 2015; v1 submitted 23 March, 2015;
originally announced March 2015.
-
Spectral measurement of electron antineutrino oscillation amplitude and frequency at Daya Bay
Authors:
Daya Bay Collaboration,
F. P. An,
A. B. Balantekin,
H. R. Band,
W. Beriguete,
M. Bishai,
S. Blyth,
R. L. Brown,
I. Butorov,
G. F. Cao,
J. Cao,
R. Carr,
Y. L. Chan,
J. F. Chang,
Y. Chang,
C. Chasman,
H. S. Chen,
H. Y. Chen,
S. J. Chen,
S. M. Chen,
X. C. Chen,
X. H. Chen,
Y. Chen,
Y. X. Chen,
Y. P. Cheng
, et al. (214 additional authors not shown)
Abstract:
A measurement of the energy dependence of antineutrino disappearance at the Daya Bay Reactor Neutrino Experiment is reported. Electron antineutrinos ($\overlineν_{e}$) from six $2.9$ GW$_{\rm th}$ reactors were detected with six detectors deployed in two near (effective baselines 512 m and 561 m) and one far (1579 m) underground experimental halls. Using 217 days of data, 41589 (203809 and 92912)…
▽ More
A measurement of the energy dependence of antineutrino disappearance at the Daya Bay Reactor Neutrino Experiment is reported. Electron antineutrinos ($\overlineν_{e}$) from six $2.9$ GW$_{\rm th}$ reactors were detected with six detectors deployed in two near (effective baselines 512 m and 561 m) and one far (1579 m) underground experimental halls. Using 217 days of data, 41589 (203809 and 92912) antineutrino candidates were detected in the far hall (near halls). An improved measurement of the oscillation amplitude $\sin^{2}2θ_{13} = 0.090^{+0.008}_{-0.009} $ and the first direct measurement of the $\overlineν_{e}$ mass-squared difference $|Δm^{2}_{ee}|= (2.59_{-0.20}^{+0.19}) \times 10^{-3}\ {\rm eV}^2 $ is obtained using the observed $\overlineν_{e}$ rates and energy spectra in a three-neutrino framework.
This value of $|Δm^{2}_{ee}|$ is consistent with $|Δm^{2}_{μμ}|$ measured by muon neutrino disappearance, supporting the three-flavor oscillation model.
△ Less
Submitted 15 January, 2014; v1 submitted 24 October, 2013;
originally announced October 2013.
-
Assembly and Installation of the Daya Bay Antineutrino Detectors
Authors:
H. R. Band,
R. L. Brown,
R. Carr,
X. C. Chen,
X. H. Chen,
J. J. Cherwinka,
M. C. Chu,
E. Draeger,
D. A. Dwyer,
W. R. Edwards,
R. Gill,
J. Goett,
L. S. Greenler,
W. Q. Gu,
W. S. He,
K. M. Heeger,
Y. K. Heng,
P. Hinrichs,
T. H. Ho,
M. Hoff,
Y. B. Hsiung,
Y. **,
L. Kang,
S. H. Kettell,
M. Kramer
, et al. (44 additional authors not shown)
Abstract:
The Daya Bay reactor antineutrino experiment is designed to make a precision measurement of the neutrino mixing angle theta13, and recently made the definitive discovery of its nonzero value. It utilizes a set of eight, functionally identical antineutrino detectors to measure the reactor flux and spectrum at baselines of 300 - 2000m from the Daya Bay and Ling Ao Nuclear Power Plants. The Daya Bay…
▽ More
The Daya Bay reactor antineutrino experiment is designed to make a precision measurement of the neutrino mixing angle theta13, and recently made the definitive discovery of its nonzero value. It utilizes a set of eight, functionally identical antineutrino detectors to measure the reactor flux and spectrum at baselines of 300 - 2000m from the Daya Bay and Ling Ao Nuclear Power Plants. The Daya Bay antineutrino detectors were built in an above-ground facility and deployed side-by-side at three underground experimental sites near and far from the nuclear reactors. This configuration allows the experiment to make a precision measurement of reactor antineutrino disappearance over km-long baselines and reduces relative systematic uncertainties between detectors and nuclear reactors. This paper describes the assembly and installation of the Daya Bay antineutrino detectors.
△ Less
Submitted 6 September, 2013;
originally announced September 2013.
-
Precision Measurement of the Neutron Beta-Decay Asymmetry
Authors:
M. P. Mendenhall,
R. W. Pattie Jr,
Y. Bagdasarova,
D. B. Berguno,
L. J. Broussard,
R. Carr,
S. Currie,
X. Ding,
B. W. Filippone,
A. García,
P. Geltenbort,
K. P. Hickerson,
J. Hoagland,
A. T. Holley,
R. Hong,
T. M. Ito,
A. Knecht,
C. -Y. Liu,
J. L. Liu,
M. Makela,
R. R. Mammei,
J. W. Martin,
D. Melconian,
S. D. Moore,
C. L. Morris
, et al. (16 additional authors not shown)
Abstract:
A new measurement of the neutron $β$-decay asymmetry $A_0$ has been carried out by the UCNA collaboration using polarized ultracold neutrons (UCN) from the solid deuterium UCN source at the Los Alamos Neutron Science Center (LANSCE). Improvements in the experiment have led to reductions in both statistical and systematic uncertainties leading to $A_0 = -0.11954(55)_{\rm stat.}(98)_{\rm syst.}$, co…
▽ More
A new measurement of the neutron $β$-decay asymmetry $A_0$ has been carried out by the UCNA collaboration using polarized ultracold neutrons (UCN) from the solid deuterium UCN source at the Los Alamos Neutron Science Center (LANSCE). Improvements in the experiment have led to reductions in both statistical and systematic uncertainties leading to $A_0 = -0.11954(55)_{\rm stat.}(98)_{\rm syst.}$, corresponding to the ratio of axial-vector to vector coupling $λ\equiv g_A/g_V = -1.2756(30)$.
△ Less
Submitted 19 February, 2013; v1 submitted 25 October, 2012;
originally announced October 2012.
-
Improved Measurement of Electron Antineutrino Disappearance at Daya Bay
Authors:
Daya Bay Collaboration,
F. P. An,
Q. An,
J. Z. Bai,
A. B. Balantekin,
H. R. Band,
W. Beriguete,
M. Bishai,
S. Blyth,
R. L. Brown,
G. F. Cao,
J. Cao,
R. Carr,
W. T. Chan,
J. F. Chang,
Y. Chang,
C. Chasman,
H. S. Chen,
H. Y. Chen,
S. J. Chen,
S. M. Chen,
X. C. Chen,
X. H. Chen,
X. S. Chen,
Y. Chen
, et al. (207 additional authors not shown)
Abstract:
We report an improved measurement of the neutrino mixing angle $θ_{13}$ from the Daya Bay Reactor Neutrino Experiment. We exclude a zero value for $\sin^22θ_{13}$ with a significance of 7.7 standard deviations. Electron antineutrinos from six reactors of 2.9 GW$_{\rm th}$ were detected in six antineutrino detectors deployed in two near (flux-weighted baselines of 470 m and 576 m) and one far (1648…
▽ More
We report an improved measurement of the neutrino mixing angle $θ_{13}$ from the Daya Bay Reactor Neutrino Experiment. We exclude a zero value for $\sin^22θ_{13}$ with a significance of 7.7 standard deviations. Electron antineutrinos from six reactors of 2.9 GW$_{\rm th}$ were detected in six antineutrino detectors deployed in two near (flux-weighted baselines of 470 m and 576 m) and one far (1648 m) underground experimental halls. Using 139 days of data, 28909 (205308) electron antineutrino candidates were detected at the far hall (near halls). The ratio of the observed to the expected number of antineutrinos assuming no oscillations at the far hall is $0.944\pm 0.007({\rm stat.}) \pm 0.003({\rm syst.})$. An analysis of the relative rates in six detectors finds $\sin^22θ_{13}=0.089\pm 0.010({\rm stat.})\pm0.005({\rm syst.})$ in a three-neutrino framework.
△ Less
Submitted 17 November, 2012; v1 submitted 23 October, 2012;
originally announced October 2012.
-
Direct Measurement of Backgrounds using Reactor-Off Data in Double Chooz
Authors:
Y. Abe,
C. Aberle,
J. C. dos Anjos,
J. C. Barriere,
M. Bergevin,
A. Bernstein,
T. J. C. Bezerra,
L. Bezrukhov,
E. Blucher,
N. S. Bowden,
C. Buck,
J. Busenitz,
A. Cabrera,
E. Caden,
L. Camilleri,
R. Carr,
M. Cerrada,
P. -J. Chang,
P. Chimenti,
T. Classen,
A. P. Collin,
E. Conover,
J. M. Conrad,
J. I. Crespo-Anadon,
K. Crum
, et al. (148 additional authors not shown)
Abstract:
Double Chooz is unique among modern reactor-based neutrino experiments studying $\bar ν_e$ disappearance in that data can be collected with all reactors off. In this paper, we present data from 7.53 days of reactor-off running. Applying the same selection criteria as used in the Double Chooz reactor-on oscillation analysis, a measured background rate of 1.0$\pm$0.4 events/day is obtained. The back…
▽ More
Double Chooz is unique among modern reactor-based neutrino experiments studying $\bar ν_e$ disappearance in that data can be collected with all reactors off. In this paper, we present data from 7.53 days of reactor-off running. Applying the same selection criteria as used in the Double Chooz reactor-on oscillation analysis, a measured background rate of 1.0$\pm$0.4 events/day is obtained. The background model for accidentals, cosmogenic $β$-$n$-emitting isotopes, fast neutrons from cosmic muons, and stopped-$μ$ decays used in the oscillation analysis is demonstrated to be correct within the uncertainties. Kinematic distributions of the events, which are dominantly cosmic-ray-produced correlated-background events, are provided. The background rates are scaled to the shielding depths of two other reactor-based oscillation experiments, Daya Bay and RENO.
△ Less
Submitted 20 October, 2012; v1 submitted 13 October, 2012;
originally announced October 2012.
-
Measurement of the neutron $β$-asymmetry parameter $A_0$ with ultracold neutrons
Authors:
UCNA Collaboration,
B. Plaster,
R. Rios,
H. O. Back,
T. J. Bowles,
L. J. Broussard,
R. Carr,
S. Clayton,
S. Currie,
B. W. Filippone,
A. Garcia,
P. Geltenbort,
K. P. Hickerson,
J. Hoagland,
G. E. Hogan,
B. Hona,
A. T. Holley,
T. M. Ito,
C. -Y. Liu,
J. Liu,
M. Makela,
R. R. Mammei,
J. W. Martin,
D. Melconian,
M. P. Mendenhall
, et al. (21 additional authors not shown)
Abstract:
We present a detailed report of a measurement of the neutron $β$-asymmetry parameter $A_0$, the parity-violating angular correlation between the neutron spin and the decay electron momentum, performed with polarized ultracold neutrons (UCN). UCN were extracted from a pulsed spallation solid deuterium source and polarized via transport through a 7-T magnetic field. The polarized UCN were then trans…
▽ More
We present a detailed report of a measurement of the neutron $β$-asymmetry parameter $A_0$, the parity-violating angular correlation between the neutron spin and the decay electron momentum, performed with polarized ultracold neutrons (UCN). UCN were extracted from a pulsed spallation solid deuterium source and polarized via transport through a 7-T magnetic field. The polarized UCN were then transported through an adiabatic-fast-passage spin-flipper field region, prior to storage in a cylindrical decay volume situated within a 1-T $2 \times 2π$ solenoidal spectrometer. The asymmetry was extracted from measurements of the decay electrons in multiwire proportional chamber and plastic scintillator detector packages located on both ends of the spectrometer. From an analysis of data acquired during runs in 2008 and 2009, we report $A_0 = -0.11966 \pm 0.00089_{-0.00140} ^{+0.00123}$, from which we extract a value for the ratio of the weak axial-vector and vector coupling constants of the nucleon, $λ= g_A/g_V = -1.27590 \pm 0.00239_{-0.00377}^{+0.00331}$. Complete details of the analysis are presented.
△ Less
Submitted 25 July, 2012;
originally announced July 2012.
-
A side-by-side comparison of Daya Bay antineutrino detectors
Authors:
Daya Bay Collaboration,
F. P. An,
Q. An,
J. Z. Bai,
A. B. Balantekin,
H. R. Band,
W. Beriguete,
M. Bishai,
S. Blyth,
R. L. Brown,
G. F. Cao,
J. Cao,
R. Carr,
J. F. Chang,
Y. Chang,
C. Chasman,
H. S. Chen,
S. J. Chen,
S. M. Chen,
X. C. Chen,
X. H. Chen,
X. S. Chen,
Y. Chen,
J. J. Cherwinka,
M. C. Chu
, et al. (218 additional authors not shown)
Abstract:
The Daya Bay Reactor Neutrino Experiment is designed to determine precisely the neutrino mixing angle $θ_{13}$ with a sensitivity better than 0.01 in the parameter sin$^22θ_{13}$ at the 90% confidence level. To achieve this goal, the collaboration will build eight functionally identical antineutrino detectors. The first two detectors have been constructed, installed and commissioned in Experimenta…
▽ More
The Daya Bay Reactor Neutrino Experiment is designed to determine precisely the neutrino mixing angle $θ_{13}$ with a sensitivity better than 0.01 in the parameter sin$^22θ_{13}$ at the 90% confidence level. To achieve this goal, the collaboration will build eight functionally identical antineutrino detectors. The first two detectors have been constructed, installed and commissioned in Experimental Hall 1, with steady data-taking beginning September 23, 2011. A comparison of the data collected over the subsequent three months indicates that the detectors are functionally identical, and that detector-related systematic uncertainties exceed requirements.
△ Less
Submitted 28 February, 2012;
originally announced February 2012.
-
The G0 Experiment: Apparatus for Parity-Violating Electron Scattering Measurements at Forward and Backward Angles
Authors:
G0 Collaboration,
D. Androic,
D. S. Armstrong,
J. Arvieux,
R. Asaturyan,
T. D. Averett,
S. L. Bailey,
G. Batigne,
D. H. Beck,
E. J. Beise,
J. Benesch,
F. Benmokhtar,
L. Bimbot,
J. Birchall,
A. Biselli,
P. Bosted,
H. Breuer,
P. Brindza,
C. L. Capuano,
R. D. Carlini,
R. Carr,
N. Chant,
Y. -C. Chao,
R. Clark,
A. Coppens
, et al. (105 additional authors not shown)
Abstract:
In the G0 experiment, performed at Jefferson Lab, the parity-violating elastic scattering of electrons from protons and quasi-elastic scattering from deuterons is measured in order to determine the neutral weak currents of the nucleon. Asymmetries as small as 1 part per million in the scattering of a polarized electron beam are determined using a dedicated apparatus. It consists of specialized bea…
▽ More
In the G0 experiment, performed at Jefferson Lab, the parity-violating elastic scattering of electrons from protons and quasi-elastic scattering from deuterons is measured in order to determine the neutral weak currents of the nucleon. Asymmetries as small as 1 part per million in the scattering of a polarized electron beam are determined using a dedicated apparatus. It consists of specialized beam-monitoring and control systems, a cryogenic hydrogen (or deuterium) target, and a superconducting, toroidal magnetic spectrometer equipped with plastic scintillation and aerogel Cerenkov detectors, as well as fast readout electronics for the measurement of individual events. The overall design and performance of this experimental system is discussed.
△ Less
Submitted 3 March, 2011;
originally announced March 2011.
-
Determination of the Axial-Vector Weak Coupling Constant with Ultracold Neutrons
Authors:
UCNA Collaboration,
J. Liu,
M. P. Mendenhall,
A. T. Holley,
H. O. Back,
T. J. Bowles,
L. J. Broussard,
R. Carr,
S. Clayton,
S. Currie,
B. W. Filippone,
A. Garcia,
P. Geltenbort,
K. P. Hickerson,
J. Hoagland,
G. E. Hogan,
B. Hona,
T. M. Ito,
C. -Y. Liu,
M. Makela,
R. R. Mammei,
J. W. Martin,
D. Melconian,
C. L. Morris,
R. W. Pattie Jr.
, et al. (15 additional authors not shown)
Abstract:
A precise measurement of the neutron decay $β$-asymmetry $A_0$ has been carried out using polarized ultracold neutrons (UCN) from the pulsed spallation UCN source at the Los Alamos Neutron Science Center (LANSCE). Combining data obtained in 2008 and 2009, we report $A_0 = -0.11966 \pm 0.00089_{-0.00140}^{+0.00123}$, from which we determine the ratio of the axial-vector to vector weak coupling of t…
▽ More
A precise measurement of the neutron decay $β$-asymmetry $A_0$ has been carried out using polarized ultracold neutrons (UCN) from the pulsed spallation UCN source at the Los Alamos Neutron Science Center (LANSCE). Combining data obtained in 2008 and 2009, we report $A_0 = -0.11966 \pm 0.00089_{-0.00140}^{+0.00123}$, from which we determine the ratio of the axial-vector to vector weak coupling of the nucleon $g_A/g_V = -1.27590_{-0.00445}^{+0.00409}$.
△ Less
Submitted 24 September, 2010; v1 submitted 21 July, 2010;
originally announced July 2010.
-
A solenoidal electron spectrometer for a precision measurement of the neutron $β$-asymmetry with ultracold neutrons
Authors:
B. Plaster,
R. Carr,
B. W. Filippone,
D. Harrison,
J. Hsiao,
T. M. Ito,
J. Liu,
J. W. Martin,
B. Tipton,
J. Yuan
Abstract:
We describe an electron spectrometer designed for a precision measurement of the neutron $β$-asymmetry with spin-polarized ultracold neutrons. The spectrometer consists of a 1.0-Tesla solenoidal field with two identical multiwire proportional chamber and plastic scintillator electron detector packages situated within 0.6-Tesla field-expansion regions. Select results from performance studies of t…
▽ More
We describe an electron spectrometer designed for a precision measurement of the neutron $β$-asymmetry with spin-polarized ultracold neutrons. The spectrometer consists of a 1.0-Tesla solenoidal field with two identical multiwire proportional chamber and plastic scintillator electron detector packages situated within 0.6-Tesla field-expansion regions. Select results from performance studies of the spectrometer with calibration sources are reported.
△ Less
Submitted 12 June, 2008;
originally announced June 2008.
-
A Multiwire Proportional Chamber for Precision Studies of Neutron Beta Decay Angular Correlations
Authors:
T. M. Ito,
R. Carr,
B. W. Filippone,
J. W. Martin,
B. Plaster,
G. Rybka,
J. Yuan
Abstract:
A new multiwire proportional chamber (MWPC) was designed and constructed for precision studies of neutron beta decay angular correlations. Its design has several novel features, including the use of low pressure neopentane as the MWPC gas and an entrance window made of thin Mylar sheet reinforced with Kevlar fibers. In the initial off-line performance tests, the gas gain of neopentane and the po…
▽ More
A new multiwire proportional chamber (MWPC) was designed and constructed for precision studies of neutron beta decay angular correlations. Its design has several novel features, including the use of low pressure neopentane as the MWPC gas and an entrance window made of thin Mylar sheet reinforced with Kevlar fibers. In the initial off-line performance tests, the gas gain of neopentane and the position resolution were studied.
△ Less
Submitted 10 February, 2007;
originally announced February 2007.
-
The Cryogenic Target for the G$^0$ Experiment at Jefferson Lab
Authors:
S. D. Covrig,
E. J. Beise,
R. Carr,
K. K. Gustafsson,
L. Hannelius,
M. -C. Herda,
C. E. Jones,
J. Liu,
R. D. McKeown,
R. Neveling,
A. W. Rauf,
G. Smith
Abstract:
A cryogenic horizontal single loop target has been designed, built, tested and operated for the G$^0$ experiment in Hall C at Jefferson Lab. The target cell is 20 cm long, the loop volume is 6.5 l and the target operates with the cryogenic pump fully immersed in the fluid. The target has been designed to operate at 30 Hz rotational pump speed with either liquid hydrogen or liquid deuterium. The…
▽ More
A cryogenic horizontal single loop target has been designed, built, tested and operated for the G$^0$ experiment in Hall C at Jefferson Lab. The target cell is 20 cm long, the loop volume is 6.5 l and the target operates with the cryogenic pump fully immersed in the fluid. The target has been designed to operate at 30 Hz rotational pump speed with either liquid hydrogen or liquid deuterium. The high power heat exchanger is able to remove 1000 W of heat from the liquid hydrogen, while the nominal electron beam with current of 40 $μ$A and energy of 3 GeV deposits about 320 W of heat into the liquid. The increase in the systematic uncertainty due to the liquid hydrogen target is negligible on the scale of a parity violation experiment. The global normalized yield reduction for 40 $μ$A beam is about 1.5 % and the target density fluctuations contribute less than 238 ppm (parts per million) to the total asymmetry width, typically about 1200 ppm, in a Q$^2$ bin.
△ Less
Submitted 22 February, 2005;
originally announced February 2005.
-
Measurement of the vector analyzing power in elastic electron-proton scattering as a probe of double photon exchange amplitudes
Authors:
S. P. Wells,
T. Averett,
D. Barkhuff,
D. H. Beck,
E. J. Beise,
C. Benson,
H. Breuer,
R. Carr,
S. Covrig,
J. DelCorso,
G. Dodson,
C. Eppstein,
M. Farkhondeh,
B. W. Filippone,
T. Forest,
P. Frasier,
R. Hasty,
T. M. Ito,
C. Jones,
W. Korsch,
S. Kowalski,
P. Lee,
E. Maneva,
K. McCarty,
R. D. McKeown
, et al. (12 additional authors not shown)
Abstract:
We report the first measurement of the vector analyzing power in inclusive transversely polarized elastic electron-proton scattering at Q^2 = 0.1 (GeV/c)^2 and large scattering angles. This quantity should vanish in the single virtual photon exchange, plane wave impulse approximation for this reaction, and can therefore provide information on double photon exchange amplitudes for electromagnetic…
▽ More
We report the first measurement of the vector analyzing power in inclusive transversely polarized elastic electron-proton scattering at Q^2 = 0.1 (GeV/c)^2 and large scattering angles. This quantity should vanish in the single virtual photon exchange, plane wave impulse approximation for this reaction, and can therefore provide information on double photon exchange amplitudes for electromagnetic interactions with hadronic systems. We find a non-zero value of A=-15.4+/-5.4 ppm. No calculations of this observable for nuclei other than spin 0 have been carried out in these kinematics, and the calculation using the spin orbit interaction from a charged point nucleus of spin 0 cannot describe these data.
△ Less
Submitted 22 February, 2000;
originally announced February 2000.
-
Measurement of the Proton's Neutral Weak Magnetic Form Factor
Authors:
B. Mueller,
D. H. Beck,
E. J. Beise,
E. Candell,
L. Cardman,
R. Carr,
R. C. DiBari,
G. Dodson,
K. Dow,
F. Duncan,
M. Farkhondeh,
B. W. Filippone,
T. Forest,
H. Gao,
W. Korsch,
S. Kowalski,
A. Lung,
R. D. McKeown,
R. Mohring,
J. Napolitano,
D. Nilsson,
M. Pitt,
N. Simicevic,
B. Terburg,
S. P. Wells
Abstract:
We report the first measurement of the parity-violating asymmetry in elastic electron scattering from the proton. The asymmetry depends on the neutral weak magnetic form factor of the proton which contains new information on the contribution of strange quark-antiquark pairs to the magnetic moment of the proton. We obtain the value $G_M^Z= 0.34 \pm 0.09 \pm 0.04 \pm 0.05$ n.m. at $Q^2=0.1$ (GeV/c…
▽ More
We report the first measurement of the parity-violating asymmetry in elastic electron scattering from the proton. The asymmetry depends on the neutral weak magnetic form factor of the proton which contains new information on the contribution of strange quark-antiquark pairs to the magnetic moment of the proton. We obtain the value $G_M^Z= 0.34 \pm 0.09 \pm 0.04 \pm 0.05$ n.m. at $Q^2=0.1$ (GeV/c)${}^2$.
△ Less
Submitted 26 February, 1997;
originally announced February 1997.
-
A High Power Hydrogen Target for Parity Violation Experiments
Authors:
E. J. Beise,
D. H. Beck,
E. Candell,
R. Carr,
F. Duncan,
T. Forest,
W. Korsch,
J. W. Mark,
R. D. McKeown,
B. A. Mueller,
S. Wells
Abstract:
Parity-violating electron scattering measurements on hydrogen and deuterium, such as those underway at the Bates and CEBAF laboratories, require luminosities exceeding $10^{38}$cm$^{-2}$s$^{-1}$, resulting in large beam power deposition into cryogenic liquid. Such targets must be able to absorb 500 watts or more with minimal change in target density. A 40~cm long liquid hydrogen target, designed…
▽ More
Parity-violating electron scattering measurements on hydrogen and deuterium, such as those underway at the Bates and CEBAF laboratories, require luminosities exceeding $10^{38}$cm$^{-2}$s$^{-1}$, resulting in large beam power deposition into cryogenic liquid. Such targets must be able to absorb 500 watts or more with minimal change in target density. A 40~cm long liquid hydrogen target, designed to absorb 500~watts of beam power without boiling, has been developed for the SAMPLE experiment at Bates. In recent tests with 40~$μ$A of incident beam, no evidence was seen for density fluctuations in the target, at a sensitivity level of better than 1\%. A summary of the target design and operational experience will be presented.
△ Less
Submitted 14 February, 1996;
originally announced February 1996.
-
SAMPLE: Parity Violating Electron Scattering from Hydrogen and Deuterium
Authors:
E. J. Beise,
J. Arrington,
D. H. Beck,
E. Candell,
R. Carr,
G. Dodson,
K. Dow,
F. Duncan,
M. Farkhondeh,
B. W. Filippone,
T. FOrest,
H. Gao,
W. Korsch,
S. Kowalski,
A. Lung,
R. D. McKeown,
R. Mohring,
B. A. Mueller,
J. Napolitano,
M. Pitt,
N. Simicevic,
E. Tsentalovich,
S. Wells
Abstract:
Recently, there has been considerable theoretical interest in determining strange quark contributions to hadronic matrix elements. Such matrix elements can be accessed through the nucleon's neutral weak form factors as determined in parity violating electron scattering. The SAMPLE experiment will measure the strange magnetic form factor $G_M^s$ at low momentum transfer. By combining measurements…
▽ More
Recently, there has been considerable theoretical interest in determining strange quark contributions to hadronic matrix elements. Such matrix elements can be accessed through the nucleon's neutral weak form factors as determined in parity violating electron scattering. The SAMPLE experiment will measure the strange magnetic form factor $G_M^s$ at low momentum transfer. By combining measurements from hydrogen and deuterium the theoretical uncertainties in the measurement can be greatly reduced and the result will be limited by experimental errors only. A summary of recent progress on the SAMPLE experiment is presented.
△ Less
Submitted 6 February, 1996;
originally announced February 1996.