Detector performance of the Gamma-ray Transient Monitor onboard DRO-A Satellite
Authors:
Pei-Yi Feng,
Zheng-Hua An,
Da-Li Zhang,
Chen-Wei Wang,
Chao Zheng,
Sheng Yang,
Shao-Lin Xiong,
Jia-Cong Liu,
Xin-Qiao Li,
Ke Gong,
Xiao-**g Liu,
Min Gao,
Xiang-Yang Wen,
Ya-Qing liu,
Xiao-Yun Zhao,
Fan Zhang,
Xi-Lei Sun,
Hong Lu
Abstract:
Gamma-ray Transient Monitor (GTM) is an all-sky monitor onboard the Distant Retrograde Orbit-A (DRO-A) satellite with the scientific objective of detecting gamma-ray transients ranging from 20 keV to 1 MeV. GTM is equipped with 5 Gamma-ray Transient Probe (GTP) detector modules, utilizing the NaI(Tl) scintillator coupled with a SiPM array. To reduce the SiPM noise, GTP makes use of a dedicated dua…
▽ More
Gamma-ray Transient Monitor (GTM) is an all-sky monitor onboard the Distant Retrograde Orbit-A (DRO-A) satellite with the scientific objective of detecting gamma-ray transients ranging from 20 keV to 1 MeV. GTM is equipped with 5 Gamma-ray Transient Probe (GTP) detector modules, utilizing the NaI(Tl) scintillator coupled with a SiPM array. To reduce the SiPM noise, GTP makes use of a dedicated dual-channel coincident readout design. In this work, we firstly studied the impact of different coincidence times on detection efficiency and ultimately selected the 500 ns time coincidence window for offline data processing. To test the performance of GTPs and validate the Monte Carlo simulated energy response, we conducted comprehensive ground calibration tests using Hard X-ray Calibration Facility (HXCF) and radioactive sources, including energy response, detection efficiency, spatial response, bias-voltage response, and temperature dependence. We extensively presented the ground calibration results, and validated the design and mass model of GTP detector. These work paved the road for the in-flight observation and science data analysis.
△ Less
Submitted 15 January, 2024;
originally announced January 2024.
-
The Intrinsic Energy Resolution of LaBr$_3$(Ce) Crystal for GECAM
Authors:
Pei-Yi Feng,
Xi-Lei Sun,
Cheng-Er Wang,
Yong Deng,
Zheng-Hua An,
Da-Li Zhang,
Chao Zheng,
Xin-Qiao Li,
Shao-Lin Xiong,
Hong Lu
Abstract:
The intrinsic resolution is the primary limitation on the total energy resolution of LaBr$_3$(Ce) crystal. This intrinsic resolution arises from two effects: fluctuations occurring in the process of energy transfer to luminescent centers within the LaBr$_3$(Ce) crystal and the LaBr$_3$(Ce) crystal's non-proportional luminescence. Presently, experimental measurements regarding the intrinsic resolut…
▽ More
The intrinsic resolution is the primary limitation on the total energy resolution of LaBr$_3$(Ce) crystal. This intrinsic resolution arises from two effects: fluctuations occurring in the process of energy transfer to luminescent centers within the LaBr$_3$(Ce) crystal and the LaBr$_3$(Ce) crystal's non-proportional luminescence. Presently, experimental measurements regarding the intrinsic resolution of LaBr$_3$(Ce) crystal are scarce, and the underlying physical mechanisms remain incompletely understood. In this paper, we aim to elucidate the concept of intrinsic resolution. We investigated the entire physical process of luminescence following energy deposition in the LaBr$_3$(Ce) crystal, quantifying the various components in the total energy resolution. We conducted a series of experimental measurements and Geant4 simulations, determining the intrinsic resolution of LaBr$_3$(Ce) crystal to 100 keV electrons as 2.12%. The non-proportionality contributes significantly at 1.43%, while fluctuations in the energy transfer process accounted for 0.27%. It is evident that non-proportionality in light output constitutes the primary source of intrinsic resolution. Horizontal and vertical unevenness in light collection contributed 0.25% and 0.07%, respectively. Statistical fluctuations showed the largest impact on the total energy resolution, at 2.86%. The contribution from fluctuations in single-photoelectron events was 0.77%. Furthermore, we reconstructed the photon response using Geant4, and the consistency between the simulated relative light yield and the experimentally measured one confirmed the reliability of the LaBr$_3$(Ce) detector mass model employed in the simulation.
△ Less
Submitted 30 December, 2023;
originally announced January 2024.
-
The Energy Response of LaBr3(Ce), LaBr3(Ce,Sr) and NaI(Tl) Crystals for GECAM
Authors:
Pei-Yi Feng,
Xi-Lei Sun,
Zheng-Hua An,
Yong Deng,
Cheng-Er Wang,
Huang Jiang,
Jun-Jie Li,
Da-Li Zhang,
Xin-Qiao Li,
Shao-Lin Xiong,
Chao Zheng,
Ke Gong,
Sheng Yang,
Xiao-**g Liu,
Min Gao,
Xiang-Yang Wen,
Ya-Qing Liu,
Yan-Bing Xu,
Xiao-Yun Zhao,
Jia-Cong Liu,
Fan Zhang,
Hong Lu
Abstract:
The GECAM series of satellites utilize LaBr3(Ce), LaBr3(Ce,Sr), and NaI(Tl) crystals as sensitive materials for gamma-ray detectors (GRDs). To investigate the non-linearity in the detection of low-energy gamma rays and address errors in the E-C relationship calibration, comprehensive tests and comparative studies of the non-linearity of these three crystals were conducted using Compton electrons,…
▽ More
The GECAM series of satellites utilize LaBr3(Ce), LaBr3(Ce,Sr), and NaI(Tl) crystals as sensitive materials for gamma-ray detectors (GRDs). To investigate the non-linearity in the detection of low-energy gamma rays and address errors in the E-C relationship calibration, comprehensive tests and comparative studies of the non-linearity of these three crystals were conducted using Compton electrons, radioactive sources, and mono-energetic X-rays. The non-linearity test results for Compton electrons and X-rays displayed substantial differences, with all three crystals showing higher non-linearity for X-rays and gamma-rays than for Compton electrons. Despite LaBr3(Ce) and LaBr3(Ce,Sr) crystals having higher absolute light yields, they exhibited a noticeable non-linear decrease in light yield, especially at energies below 400 keV. The NaI(Tl) crystal demonstrated excess light output in the 6~200 keV range, reaching a maximum excess of 9.2% at 30 keV in X-ray testing and up to 15.5% at 14 keV during Compton electron testing, indicating a significant advantage in the detection of low-energy gamma rays. Furthermore, this paper explores the underlying causes of the observed non-linearity in these crystals. This study not only elucidates the detector responses of GECAM, but also marks the inaugural comprehensive investigation into the non-linearity of domestically produced lanthanum bromide and sodium iodide crystals.
△ Less
Submitted 27 December, 2023;
originally announced December 2023.
-
Deep underground laboratory measurement of $^{13}$C($α$,$n$)$^{16}$O in the Gamow windows of the $s$- and $i$-processes
Authors:
B. Gao,
T. Y. Jiao,
Y. T. Li,
H. Chen,
W. P. Lin,
Z. An,
L. H. Ru,
Z. C. Zhang,
X. D. Tang,
X. Y. Wang,
N. T. Zhang,
X. Fang,
D. H. Xie,
Y. H. Fan,
L. Ma,
X. Zhang,
F. Bai,
P. Wang,
Y. X. Fan,
G. Liu,
H. X. Huang,
Q. Wu,
Y. B. Zhu,
J. L. Chai,
J. Q. Li
, et al. (50 additional authors not shown)
Abstract:
The $^{13}$C($α$,$n$)$^{16}$O reaction is the main neutron source for the slow-neutron-capture (s-) process in Asymptotic Giant Branch stars and for the intermediate (i-) process. Direct measurements at astrophysical energies in above-ground laboratories are hindered by the extremely small cross sections and vast cosmic-ray induced background. We performed the first consistent direct measurement i…
▽ More
The $^{13}$C($α$,$n$)$^{16}$O reaction is the main neutron source for the slow-neutron-capture (s-) process in Asymptotic Giant Branch stars and for the intermediate (i-) process. Direct measurements at astrophysical energies in above-ground laboratories are hindered by the extremely small cross sections and vast cosmic-ray induced background. We performed the first consistent direct measurement in the range of $E_{\rm c.m.}=$0.24 MeV to 1.9 MeV using the accelerators at the China **** Underground Laboratory (CJPL) and Sichuan University. Our measurement covers almost the entire i-process Gamow window in which the large uncertainty of the previous experiments has been reduced from 60\% down to 15\%, eliminates the large systematic uncertainty in the extrapolation arising from the inconsistency of existing data sets, and provides a more reliable reaction rate for the studies of the s- and i-processes along with the first direct determination of the alpha strength for the near-threshold state.
△ Less
Submitted 6 October, 2022;
originally announced October 2022.
-
Neutron capture measurement and resonance parameter analysis of natSm
Authors:
X. X. Li,
L. X. Liu,
W. Jiang,
J. Ren,
H. W. Wang,
G. T. Fan,
J. J. He,
D. X. Wang,
S. Y Zhang,
Z. D. An,
X. G. Cao,
L. L. Song,
Y. Zhang,
X. R. Hu,
Z. R. Hao,
P. Kuang,
B. Jiang,
X. H. Wang,
J. F. Hu,
Y. D. Liu,
X. Ma,
C. W. Ma,
Y. T. Wang,
J. Su,
L. Y. Zhang
, et al. (5 additional authors not shown)
Abstract:
Multiple isotopes of samarium element are the isotopes produced by the s process, and 154Sm is produced by the r process. In addition, 144Sm is p nuclei in nuclear astrophysics. The measurement of these can help us to better understand the results of relevant photonuclear reaction experiments. On the other hand, 149Sm is a 235U fission product with a 1% yield, its cross sections are important to r…
▽ More
Multiple isotopes of samarium element are the isotopes produced by the s process, and 154Sm is produced by the r process. In addition, 144Sm is p nuclei in nuclear astrophysics. The measurement of these can help us to better understand the results of relevant photonuclear reaction experiments. On the other hand, 149Sm is a 235U fission product with a 1% yield, its cross sections are important to reactor neutronics. In this work, the neutron capture yield of the natural samarium target was measured at the back-streaming white neutron beamline (Back-n) of the China Spallation Neutron Source (CSNS), and the resonance parameters were analyzed by SAMMY code. The resonance peaks and the neutron separation energies contributed by the different isotopes are considered individually. The results of the capture yield found signs of the possibility of two resonance peaks at 8 eV, which awaits further experimental examination. Cross-section was calculated according to resonance parameters and was compared with other experimental results and evaluation databases of ENDF/B-VIII.0 and CENDL-3.2. A clear difference between ENDF/B VIII.0 and CENDL-3.2 database appears at 23.2 eV, the experimental result at this energy is smaller than data of ENDF/B VIII.0 database but CENDL-3.2 database. Most of the controversial experimental results invariably come from the samarium 149 isotope.
△ Less
Submitted 8 April, 2022;
originally announced April 2022.
-
Astrophysical $S_{E2}$ factor of the ${}^{12}\mathrm{C}(α,γ){}^{16}\mathrm{O}$ reaction through the ${}^{12}\mathrm{C}({}^{11}\mathrm{B},{}^{7}\mathrm{Li}){}^{16}\mathrm{O}$ transfer reaction
Authors:
Y. P. Shen,
B. Guo,
Z. H. Li,
Y. J. Li,
D. Y. Pang,
S. Adhikari,
Z. D. An,
J. Su,
S. Q. Yan,
X. C. Du,
Q. W. Fan,
L. Gan,
Z. Y. Han,
D. H. Li,
E. T. Li,
G. Lian,
J. C. Liu,
T. L. Ma,
C. J. Pei,
Y. Su,
Y. B. Wang,
Y. Zhou,
W. P. Liu
Abstract:
The ${}^{12}\mathrm{C}(α,γ){}^{16}\mathrm{O}$ reaction plays a key role in the evolution of stars with masses of $M >$ 0.55 $M_\odot$. The cross-section of the ${}^{12}\mathrm{C}(α,γ){}^{16}\mathrm{O}$ reaction within the Gamow window ($E_\textrm{c.m.}$ = 300 keV, $T_\textrm9$ = 0.2) is extremely small (about $10^{-17}$ barn), which makes the direct measurement in a ground-based laboratory with ex…
▽ More
The ${}^{12}\mathrm{C}(α,γ){}^{16}\mathrm{O}$ reaction plays a key role in the evolution of stars with masses of $M >$ 0.55 $M_\odot$. The cross-section of the ${}^{12}\mathrm{C}(α,γ){}^{16}\mathrm{O}$ reaction within the Gamow window ($E_\textrm{c.m.}$ = 300 keV, $T_\textrm9$ = 0.2) is extremely small (about $10^{-17}$ barn), which makes the direct measurement in a ground-based laboratory with existing techniques unfeasible. Up until now, the cross-sections at lower energies can only be extrapolated from the data at higher energies. However, two subthreshold resonances, located at $E_x$ = 7.117 MeV and $E_x$ = 6.917 MeV, make this extrapolation more complicated. In this work, the 6.917 MeV subthreshold resonance in the ${}^{12}\mathrm{C}(α,γ){}^{16}\mathrm{O}$ reaction was investigated via the ${}^{12}\mathrm{C}({}^{11}\mathrm{B},{}^{7}\mathrm{Li}){}^{16}\mathrm{O}$ reaction. The experiment was performed using the Q3D magnetic spectrograph at the HI-13 tandem accelerator. We measured the angular distribution of the ${}^{12}\mathrm{C}({}^{11}\mathrm{B},{}^{7}\mathrm{Li}){}^{16}\mathrm{O}$ transfer reaction leading to the 6.917 MeV state. Based on the FRDWBA analysis, we derived the asymptotic normalization coefficient (ANC) of the 6.917 MeV level in $^{16}$O to be (1.10 $\pm$ 0.29) $\times 10^{10}$ fm$^{-1}$, with which the reduced $α$ width was computed to be $18.0\pm4.7$ keV at the channel radius of 6.5 fm. Finally, we calculated the astrophysical $S_{E2}(300)$ factor of the ground-state transitions to be 46.2 $\pm$ 7.7 keV b. The result for the astrophysical $S_{E2}(300)$ factor confirms the values obtained in various direct and indirect measurements and presents an independent examination of the most important data in nuclear astrophysics.
△ Less
Submitted 15 November, 2018;
originally announced November 2018.
-
Energy Response of GECAM Gamma-Ray Detector Based on LaBr3:Ce and SiPM Array
Authors:
Da-Li Zhang,
Xin-Qiao Li,
Shao-Lin Xiong,
Wen-xi Peng,
Fan-Zhang,
Yanguo-Li,
Zheng-Hua An,
Yan-Bing Xu,
Xi-Lei Sun,
Yue Zhu
Abstract:
The Gravitational wave high-energy Electromagnetic Counterpart All-sky Monitor (GECAM) , composed of two small satellites, is a new mission to monitor the Gamma-Ray Bursts (GRBs) coincident with Gravitational Wave (GW) events with a FOV of 100% all-sky.Each GECAM satellite detects and localizes GRBs using 25 compact and novel Gamma-Ray Detectors (GRDs) in 6 keV-5 MeV. Each GRD module is comprised…
▽ More
The Gravitational wave high-energy Electromagnetic Counterpart All-sky Monitor (GECAM) , composed of two small satellites, is a new mission to monitor the Gamma-Ray Bursts (GRBs) coincident with Gravitational Wave (GW) events with a FOV of 100% all-sky.Each GECAM satellite detects and localizes GRBs using 25 compact and novel Gamma-Ray Detectors (GRDs) in 6 keV-5 MeV. Each GRD module is comprised of LaBr3:Ce scintillator, SiPM array and preamplifier. A large dynamic range of GRD is achieved by the high gain and low gain channels of the preamplifier. The energy response of GRD prototype was evaluated using radioactive sources in the range of 5.9-1332.5 keV. A energy resolution of 5.3% at 662 keV was determined from the 137Cs pulse height spectra, which meets the GECAM requirement (< 8% at 662 keV). Energy to channel conversion was evaluated and a nonlinearity correction was performed to reduce the residuals (< 1.5%). Also, a Geant4-based simulated in-flight background and a measured GRD LaBr3:Ce intrinsic activity were used to evaluate the capability of in-flight calibration. These results demonstrate the design of GRD.
△ Less
Submitted 13 December, 2021; v1 submitted 10 April, 2018;
originally announced April 2018.
-
New Astrophysical Reaction Rate for the $^{12}\textrm{C}(α,γ)^{16}\textrm{O}$ Reaction
Authors:
Z. D. An,
Y. G. Ma,
G. T. Fan,
Y. J. Li,
Z. P. Chen,
Y. Y. Sun
Abstract:
A new astrophysical reaction rate for $^{12}$C($α,γ$)$^{16}$O has been evaluated on the basis of a global R-matrix fitting to the available experimental data. The reaction rates of $^{12}$C($α,γ$)$^{16}$O for stellar temperatures between 0.04 $\leq$ $T_9$ $\leq$ 10 are provided in a tabular form and by an analytical fitting expression. At $T_9$ = 0.2, the reaction rate is (7.83 $\pm$ 0.35)…
▽ More
A new astrophysical reaction rate for $^{12}$C($α,γ$)$^{16}$O has been evaluated on the basis of a global R-matrix fitting to the available experimental data. The reaction rates of $^{12}$C($α,γ$)$^{16}$O for stellar temperatures between 0.04 $\leq$ $T_9$ $\leq$ 10 are provided in a tabular form and by an analytical fitting expression. At $T_9$ = 0.2, the reaction rate is (7.83 $\pm$ 0.35)$\times10^{15}$ $\rm{cm^3 mol^{-1} s^{-1}}$, where stellar helium burning occurs.
△ Less
Submitted 4 February, 2016;
originally announced February 2016.
-
Astrophysical S factor of {$^{12}$C($α,γ$)$^{16}$O} Calculated with the Reduced R-matrix Theory
Authors:
Zhen-Dong An,
Zhen-Peng Chen,
Yu-Gang Ma,
Jian-Kai Yu,
Ye-Ying Sun,
Gong-Tao Fan,
Yong-Jiang Li,
Hang-Hua Xu,
Bo-Song Huang,
Kan Wang
Abstract:
Determination of the accurate astrophysical S factor of {$^{12}$C($α,γ$)$^{16}$O} reaction has been regarded as a holy grail of nuclear astrophysics for decades. In current stellar models, a knowledge of that value to better than 10\% is desirable. Due to the practical issues, tremendous experimental and theoretical efforts over nearly 50 years are not able to reach this goal, and the published va…
▽ More
Determination of the accurate astrophysical S factor of {$^{12}$C($α,γ$)$^{16}$O} reaction has been regarded as a holy grail of nuclear astrophysics for decades. In current stellar models, a knowledge of that value to better than 10\% is desirable. Due to the practical issues, tremendous experimental and theoretical efforts over nearly 50 years are not able to reach this goal, and the published values contradicted with each other strongly and their uncertainties are 2 times larger than the required precision. To this end we have developed a Reduced R-matrix Theory, based on the classical R-matrix theory of Lane and Thomas, which treats primary transitions to ground state and four bound states as the independent reaction channels in the channel spin representation. With the coordination of covariance statistics and error propagation theory, a global fitting for almost all available experimental data of $^{16}$O system has been multi-iteratively analyzed by our powerful code. A reliable, accurate and self-consistent astrophysical S factor of {$^{12}$C($α,γ$)$^{16}$O} was obtained with a recommended value $S_{tot}$ (300) = 162.7 $\pm$ 7.3 keV b (4.5\%) which could meet the required precision.
△ Less
Submitted 2 September, 2015;
originally announced September 2015.
-
Tritium and helium analyses in thin films by enhanced proton backscattering
Authors:
Tao Fu,
Zhu An,
**g-Jun Zhu,
Man-Tian Liu,
Li Mao
Abstract:
In order to perform quantitative tritium and helium analysis in thin film sample by using enhanced proton backscattering (EPBS), EPBS spectra for several samples consisting of non-RBS light elements (i.e., T, 4He, 12C, 16O, natSi), medium and heavy elements have been measured and analyzed by using analytical SIMNRA and Monte Carlo-based CORTEO codes. The CORTEO code used in this paper is modified…
▽ More
In order to perform quantitative tritium and helium analysis in thin film sample by using enhanced proton backscattering (EPBS), EPBS spectra for several samples consisting of non-RBS light elements (i.e., T, 4He, 12C, 16O, natSi), medium and heavy elements have been measured and analyzed by using analytical SIMNRA and Monte Carlo-based CORTEO codes. The CORTEO code used in this paper is modified and some non-RBS cross sections of proton scattering from T, 4He, 12C, 14N, 16O and natSi elements taken from ENDF/B-VII.1 database and the calculations of SigmaCalc code are incorporated. All cross section data needed in CORTEO code over the entire proton incident energy-scattering angle plane are obtained by interpolation. It is quantitatively observed that the multiple and plural scattering effects have little impact on energy spectra for light elements like T, He, C, O and Si, and the RBS cross sections of light elements, instead of the non-RBS cross sections, can be used in SIMNRA code for dual scattering calculations for EPBS analysis. It is also observed that at the low energy part of energy spectrum the results given by CORTEO code are higher than the results of SIMNRA code and are in better agreement with the experimental data, especially when heavier elements exist in samples. For tritium analysis, the tritium depth distributions should not be simply adjusted to fit the experimental spectra when the multiple and plural scattering contributions are not completely accounted, or else inaccurate results may be obtained. For medium and heavy matrix elements, when full Monte Carlo RBS calculations are used in CORTEO code, the results from CORTEO code are in good agreement with the experimental results at the low energy part of energy spectra, at this moment quantitative tritium and helium analysis in thin film sample by using enhanced proton backscattering can be performed reliably.
△ Less
Submitted 14 October, 2013;
originally announced October 2013.