An Online Feedback Optimization Approach to Voltage Regulation in Inverter-Based Power Distribution Networks
Authors:
Alejandro D. Dominguez-Garcia,
Madi Zholbaryssov,
Temitope Amuda,
Olaoluwapo Ajala
Abstract:
We address the problem of controlling the reactive power setpoints of a set of distributed energy resources (DERs) in a power distribution network so as to mitigate the impact of variability in uncontrolled power injections associated with, e.g., renewable-based generation. We formulate the control design problem as a stochastic optimization problem, which we solve online using a modified version…
▽ More
We address the problem of controlling the reactive power setpoints of a set of distributed energy resources (DERs) in a power distribution network so as to mitigate the impact of variability in uncontrolled power injections associated with, e.g., renewable-based generation. We formulate the control design problem as a stochastic optimization problem, which we solve online using a modified version of a projected stochastic gradient descent (PSGD) algorithm. The proposed PSGD-based algorithm utilizes sensitivities of changes in bus voltage magnitudes to changes in DER reactive power setpoints; such sensitivities are learned online via a recursive least squares estimator (rLSE). To ensure proper operation of the rLSE, the sequence of incremental changes in DER reactive power setpoints needs to be persistently exciting, which is guaranteed by a mechanism built into the controller. We analyze the stability of the closed-loop system and showcase controller performance via numerical simulations on the IEEE 123-bus distribution test feeder.
△ Less
Submitted 14 March, 2023;
originally announced March 2023.
-
Integrated System Models for Networks with Generators & Inverters
Authors:
D. Venkatramanan,
Manish K. Singh,
Olaolu Ajala,
Alejandro Dominguez-Garcia,
Sairaj Dhople
Abstract:
Synchronous generators and inverter-based resources are complex systems with dynamics that cut across multiple intertwined physical domains and control loops. Modeling individual generators and inverters is, in itself, a very involved activity and has attracted dedicated attention from power engineers and control theorists over the years. Control and stability challenges associated with increasing…
▽ More
Synchronous generators and inverter-based resources are complex systems with dynamics that cut across multiple intertwined physical domains and control loops. Modeling individual generators and inverters is, in itself, a very involved activity and has attracted dedicated attention from power engineers and control theorists over the years. Control and stability challenges associated with increasing penetration of grid-following inverters have generated tremendous interest in grid-forming inverter technology. The envisioned coexistence of inverter technologies alongside rotating machines call for modeling frameworks that can accurately describe networked dynamics of interconnected generators and inverters across timescales. We put forth a comprehensive integrated system model for such a setting by: i) adopting a combination of circuit- and system-theoretic constructs, ii) unifying representations of three-phase signals across reference-frame transformations and phasor types, and iii) leveraging domain-level knowledge, engineering insights, and reasonable approximations. A running theme through our effort is to offer a clear distinction between physics-based models and the task of modeling. Among several insights spanning the spectrum from analytical to practical, we highlight how differential-algebraic-equation models and algebraic power-flow phasor models fall out of the detailed originating electromagnetic transient models.
△ Less
Submitted 24 July, 2022; v1 submitted 15 March, 2022;
originally announced March 2022.
-
Robust synchronization of electric power generators
Authors:
Olaoluwapo Ajala,
Alejandro Dominguez-Garcia,
Daniel Liberzon
Abstract:
We consider the problem of synchronizing two electric power generators, one of which (the leader) is serving a time-varying electrical load, so that they can ultimately be connected to form a single power system. Each generator is described by a second-order reduced state-space model. We assume that the generator not serving an external load initially (the follower) has access to measurements of t…
▽ More
We consider the problem of synchronizing two electric power generators, one of which (the leader) is serving a time-varying electrical load, so that they can ultimately be connected to form a single power system. Each generator is described by a second-order reduced state-space model. We assume that the generator not serving an external load initially (the follower) has access to measurements of the leader's phase angle, corrupted by some additive disturbances. By using these measurements, and leveraging results on reduced-order observers with ISS-type robustness, we propose a procedure that drives (i) the angular velocity of the follower close enough to that of the leader, and (ii) the phase angle of the follower close enough to that of the point at which both systems will be electrically connected. An explicit bound on the synchronization error in terms of the measurement disturbance and the variations in the electrical load served by the leader is computed. We illustrate the procedure via numerical simulations.
△ Less
Submitted 9 September, 2019;
originally announced September 2019.
-
A library of second-order models for synchronous machines
Authors:
Olaoluwapo Ajala,
Alejandro Dominguez-garcia,
Peter Sauer,
Daniel Liberzon
Abstract:
This paper presents a library of second-order models for synchronous machines that can be utilized in power system dynamic performance analysis and control design tasks. The models have a similar structure to the classical model in that they consist of two dynamic states, the power angle and the angular speed. However, unlike the classical model, the models find applications beyond first swing sta…
▽ More
This paper presents a library of second-order models for synchronous machines that can be utilized in power system dynamic performance analysis and control design tasks. The models have a similar structure to the classical model in that they consist of two dynamic states, the power angle and the angular speed. However, unlike the classical model, the models find applications beyond first swing stability analysis; for example, they can also be utilized in transient stability studies. The models are developed through a systematic reduction of a nineteenth-order model, using singular perturbation techniques, and they are validated by comparing their voltage, frequency, and phase profiles with that of the high-order model and that of the classical model.
△ Less
Submitted 19 September, 2019; v1 submitted 21 March, 2018;
originally announced March 2018.