-
RADES axion search results with a High-Temperature Superconducting cavity in an 11.7 T magnet
Authors:
S. Ahyoune,
A. Álvarez Melcón,
S. Arguedas Cuendis,
S. Calatroni,
C. Cogollos,
A. Díaz-Morcillo,
B. Döbrich,
J. D. Gallego,
J. M. García-Barceló,
B. Gimeno,
J. Golm,
X. Granados,
J. Gutierrez,
L. Herwig,
I. G. Irastorza,
N. Lamas,
A. Lozano-Guerrero,
W. L. Millar,
C. Malbrunot,
J. Miralda-Escudé,
P. Navarro,
J. R. Navarro-Madrid,
T. Puig,
M. Siodlaczek,
G. T. Telles
, et al. (1 additional authors not shown)
Abstract:
We describe the results of a haloscope axion search performed with an 11.7 T dipole magnet at CERN. The search used a custom-made radio-frequency cavity coated with high-temperature superconducting tape. A set of 27 h of data at a resonant frequency of around 8.84 GHz was analysed. In the range of axion mass 36.5676 $μ$eV to 36.5699 $μ$eV, corresponding to a width of 554 kHz, no signal excess hint…
▽ More
We describe the results of a haloscope axion search performed with an 11.7 T dipole magnet at CERN. The search used a custom-made radio-frequency cavity coated with high-temperature superconducting tape. A set of 27 h of data at a resonant frequency of around 8.84 GHz was analysed. In the range of axion mass 36.5676 $μ$eV to 36.5699 $μ$eV, corresponding to a width of 554 kHz, no signal excess hinting at an axion-like particle was found. Correspondingly, in this mass range, a limit on the axion to photon coupling-strength was set in the range between g$_{aγ}\gtrsim$ 6.2e-13 GeV$^{-1}$ and g$_{aγ}\gtrsim$ 1.54e-13 GeV$^{-1}$ with a 95% confidence level.
△ Less
Submitted 12 March, 2024;
originally announced March 2024.
-
Mechanical tuning of a rectangular axion haloscope operating around 8.4 GHz
Authors:
Jessica Golm,
Jose María García-Barceló,
Sergio Calatroni,
Walter Wuensch,
Babette Döbrich
Abstract:
The axion haloscope is the currently most sensitive method to probe the vanishingly small coupling of this prominent Dark Matter candidate to photons. To scan a sizeable axion Dark Matter parameter space, the cavities that make up the haloscope need to be tuned efficiently. In this article, we describe a novel technique to tune axion haloscopes around $8.4$ GHz in a purely mechanical manner withou…
▽ More
The axion haloscope is the currently most sensitive method to probe the vanishingly small coupling of this prominent Dark Matter candidate to photons. To scan a sizeable axion Dark Matter parameter space, the cavities that make up the haloscope need to be tuned efficiently. In this article, we describe a novel technique to tune axion haloscopes around $8.4$ GHz in a purely mechanical manner without the use of dielectrics. We achieve tuning by introducing a gap along the cavity geometry. Losses are added due to the leaking of the field out of the structure only if the gap becomes too large concerning the total width. A tuning range of around $600$ MHz is achieved, depending on the environmental conditions. We present the results of a corresponding prototype and outline prospects to further develop this technique.
△ Less
Submitted 20 December, 2023;
originally announced December 2023.
-
On the use of ferroelectric material in the detection of dark matter axions
Authors:
J. M. García Barceló,
A. Álvarez Melcón,
S. Arguedas Cuendis,
A. Díaz-Morcillo,
B. Gimeno,
A. Kanareykin,
A. J. Lozano-Guerrero,
P. Navarro,
W. Wuensch
Abstract:
Tuning is an essential requirement for the search of dark matter axions employing haloscopes since its mass is not known yet to the scientific community. At the present day, most haloscope tuning systems are based on mechanical devices which can lead to failures due to the complexity of the environment in which they are used. However, the electronic tuning making use of ferroelectric materials can…
▽ More
Tuning is an essential requirement for the search of dark matter axions employing haloscopes since its mass is not known yet to the scientific community. At the present day, most haloscope tuning systems are based on mechanical devices which can lead to failures due to the complexity of the environment in which they are used. However, the electronic tuning making use of ferroelectric materials can provide a path that is less vulnerable to mechanical failures and thus complements and expands current tuning systems. In this work, we present and design a novel concept for using the ferroelectric Potassium Tantalate ($KTaO_3$ or KTO) material as a tuning element in haloscopes based on coupled microwave cavities. In this line, the structures used in the Relic Axion Detector Exploratory Setup (RADES) group are based on several cavities that are connected by metallic irises, which act as interresonator coupling elements. In this article, we also show how to use these $KTaO_3$ films as interresonator couplings between cavities, instead of inductive or capacitive metallic windows used in the past. These two concepts represent a crucial upgrade over the current systems employed in the dark matter axions community, achieving a tuning range of $2.23 \, \%$ which represents a major improvement as compared to previous works ($<0.1 \, \%$) for the same class of tuning systems. The theoretical and simulated results shown in this work demonstrate the interest of the novel concepts proposed for the incorporation of this kind of ferroelectric media in multicavity resonant haloscopes in the search for dark matter axions.
△ Less
Submitted 7 December, 2022; v1 submitted 25 April, 2022;
originally announced April 2022.
-
The CLIC project
Authors:
O. Brunner,
P. N. Burrows,
S. Calatroni,
N. Catalan Lasheras,
R. Corsini,
G. D'Auria,
S. Doebert,
A. Faus-Golfe,
A. Grudiev,
A. Latina,
T. Lefevre,
G. Mcmonagle,
J. Osborne,
Y. Papaphilippou,
A. Robson,
C. Rossi,
R. Ruber,
D. Schulte,
S. Stapnes,
I. Syratchev,
W. Wuensch
Abstract:
The Compact Linear Collider (CLIC) is a multi-TeV high-luminosity linear e$^+$e$^-$-collider under development by the CLIC accelerator collaboration, hosted by CERN. The CLIC accelerator has been optimised for three energy stages at centre-of-mass energies 380 GeV, 1.5 TeV and 3 TeV. CLIC uses a novel two-beam acceleration technique, with normal-conducting accelerating structures operating in the…
▽ More
The Compact Linear Collider (CLIC) is a multi-TeV high-luminosity linear e$^+$e$^-$-collider under development by the CLIC accelerator collaboration, hosted by CERN. The CLIC accelerator has been optimised for three energy stages at centre-of-mass energies 380 GeV, 1.5 TeV and 3 TeV. CLIC uses a novel two-beam acceleration technique, with normal-conducting accelerating structures operating in the range of 70-100 MV/m.
The report describes recent achievements in accelerator design, technology development and prototy**, system tests and beam tests. Large-scale CLIC-specific beam tests have taken place, for example, at the CLIC Test Facility CTF3 at CERN, at the Accelerator Test Facility ATF2 at KEK, at the FACET facility at SLAC and at the FERMI facility in Trieste. Together, they demonstrate that all implications of the CLIC design parameters are well understood and reproducible in beam tests and prove that the CLIC performance goals are realistic. The implementation of CLIC near CERN has been investigated. Focusing on a staged approach starting at 380 GeV, this includes civil engineering aspects, electrical networks, cooling and ventilation and installation scheduling, transport. All CLIC studies have put emphasis on optimising cost and energy efficiency, and the resulting power and cost estimates are reported. The report follows very closely the accelerator project description in the CLIC Summary Report for the European Particle Physics Strategy update 2018-19.
Detailed studies of the physics potential and detector for CLIC, and R&D on detector technologies, have been carried out by the CLIC detector and physics (CLICdp) collaboration. CLIC provides excellent sensitivity to Beyond Standard Model physics, through direct searches and via a broad set of precision measurements of Standard Model processes, particularly in the Higgs and top-quark sectors.
△ Less
Submitted 18 April, 2022; v1 submitted 17 March, 2022;
originally announced March 2022.
-
Design of new resonant haloscopes in the search for the darkmatter axion: a review of the first steps in the RADES collaboration
Authors:
A. Díaz-Morcillo,
J. M. García Barceló,
A. J. Lozano-Guerrero,
P. Navarro,
B. Gimeno,
S. Arguedas Cuendis,
A. Álvarez Melcón,
C. Cogollos,
S. Calatroni,
B. Döbrich,
J. D. Gallego,
J. Golm,
I. G. Irastorza,
C. Malbrunot,
Jordi Miralda-Escudé,
C. Peña Garay,
J. Redondo,
W. Wuensch
Abstract:
Within the increasing interest in the dark matter axion detection through haloscopes, in which different international groups are currently involved, the RADES group was established in 2016 with the goal of develo** very sensitive detection systems to be operated in dipole magnets. This review deals with the work developed by this collaboration during its first five years, from the first designs…
▽ More
Within the increasing interest in the dark matter axion detection through haloscopes, in which different international groups are currently involved, the RADES group was established in 2016 with the goal of develo** very sensitive detection systems to be operated in dipole magnets. This review deals with the work developed by this collaboration during its first five years, from the first designs, based on the multi-cavity concept, aiming to increase the haloscope volume and, so, to improve its sensitivity, their evolution, the data acquisition design, and, finally, the first experimental run. Moreover, the envisaged work within RADES, for both dipole and solenoid magnets, in the short and medium term is also presented.
△ Less
Submitted 22 January, 2022; v1 submitted 29 November, 2021;
originally announced November 2021.
-
Thin Film (High Temperature) Superconducting Radiofrequency Cavities for the Search of Axion Dark Matter
Authors:
J. Golm,
S. Arguedas Cuendis,
S. Calatroni,
C. Cogollos,
B. Döbrich,
J. D. Gallego,
J. M. García Barceló,
X. Granados,
J. Gutierrez,
I. G. Irastorza,
T. Koettig,
N. Lamas,
J. Liberadzka-Porret,
C. Malbrunot,
W. L. Millar,
P. Navarro,
C. Pereira Carlos,
T. Puig,
G. J. Rosaz,
M. Siodlaczek,
G. Telles,
W. Wuensch
Abstract:
The axion is a hypothetical particle which is a candidate for cold dark matter. Haloscope experiments directly search for these particles in strong magnetic fields with RF cavities as detectors. The Relic Axion Detector Exploratory Setup (RADES) at CERN in particular is searching for axion dark matter in a mass range above 30 $μ$eV. The figure of merit of our detector depends linearly on the quali…
▽ More
The axion is a hypothetical particle which is a candidate for cold dark matter. Haloscope experiments directly search for these particles in strong magnetic fields with RF cavities as detectors. The Relic Axion Detector Exploratory Setup (RADES) at CERN in particular is searching for axion dark matter in a mass range above 30 $μ$eV. The figure of merit of our detector depends linearly on the quality factor of the cavity and therefore we are researching the possibility of coating our cavities with different superconducting materials to increase the quality factor. Since the experiment operates in strong magnetic fields of 11 T and more, superconductors with high critical magnetic fields are necessary. Suitable materials for this application are for example REBa$_2$Cu$_3$O$_{7-x}$, Nb$_3$Sn or NbN. We designed a microwave cavity which resonates at around 9~GHz, with a geometry optimized to facilitate superconducting coating and designed to fit in the bore of available high-field accelerator magnets at CERN. Several prototypes of this cavity were coated with different superconducting materials, employing different coating techniques. These prototypes were characterized in strong magnetic fields at 4.2 K.
△ Less
Submitted 9 February, 2022; v1 submitted 4 October, 2021;
originally announced October 2021.
-
First results of the CAST-RADES haloscope search for axions at 34.67 $μ$eV
Authors:
A. Álvarez Melcón,
S. Arguedas Cuendis,
J. Baier,
K. Barth,
H. Bräuniger,
S. Calatroni,
G. Cantatore,
F. Caspers,
J. F Castel,
S. A. Cetin,
C. Cogollos,
T. Dafni,
M. Davenport,
A. Dermenev,
K. Desch,
A. Díaz-Morcillo,
B. Döbrich,
H. Fischer,
W. Funk,
J. D Gallego,
J. M García Barceló,
A. Gardikiotis,
J. Garza,
B. Gimeno,
S. Gninenko
, et al. (34 additional authors not shown)
Abstract:
We present results of the Relic Axion Dark-Matter Exploratory Setup (RADES), a detector which is part of the CERN Axion Solar Telescope (CAST), searching for axion dark matter in the 34.67$μ$eV mass range. A radio frequency cavity consisting of 5 sub-cavities coupled by inductive irises took physics data inside the CAST dipole magnet for the first time using this filter-like haloscope geometry. An…
▽ More
We present results of the Relic Axion Dark-Matter Exploratory Setup (RADES), a detector which is part of the CERN Axion Solar Telescope (CAST), searching for axion dark matter in the 34.67$μ$eV mass range. A radio frequency cavity consisting of 5 sub-cavities coupled by inductive irises took physics data inside the CAST dipole magnet for the first time using this filter-like haloscope geometry. An exclusion limit with a 95% credibility level on the axion-photon coupling constant of g$_{aγ}\gtrsim 4\times10^{-13} \text{GeV}^{-1}$ over a mass range of 34.6738 $μ$eV < $m_a$ < 34.6771 $μ$eV is set. This constitutes a significant improvement over the current strongest limit set by CAST at this mass and is at the same time one of the most sensitive direct searches for an axion dark matter candidate above the mass of 25 $μ$eV. The results also demonstrate the feasibility of exploring a wider mass range around the value probed by CAST-RADES in this work using similar coherent resonant cavities.
△ Less
Submitted 27 October, 2021; v1 submitted 28 April, 2021;
originally announced April 2021.
-
Conceptual Design of BabyIAXO, the intermediate stage towards the International Axion Observatory
Authors:
A. Abeln,
K. Altenmüller,
S. Arguedas Cuendis,
E. Armengaud,
D. Attié,
S. Aune,
S. Basso,
L. Bergé,
B. Biasuzzi,
P. T. C. Borges De Sousa,
P. Brun,
N. Bykovskiy,
D. Calvet,
J. M. Carmona,
J. F. Castel,
S. Cebrián,
V. Chernov,
F. E. Christensen,
M. M. Civitani,
C. Cogollos,
T. Dafní,
A. Derbin,
K. Desch,
D. Díez,
M. Dinter
, et al. (101 additional authors not shown)
Abstract:
This article describes BabyIAXO, an intermediate experimental stage of the International Axion Observatory (IAXO), proposed to be sited at DESY. IAXO is a large-scale axion helioscope that will look for axions and axion-like particles (ALPs), produced in the Sun, with unprecedented sensitivity. BabyIAXO is conceived to test all IAXO subsystems (magnet, optics and detectors) at a relevant scale for…
▽ More
This article describes BabyIAXO, an intermediate experimental stage of the International Axion Observatory (IAXO), proposed to be sited at DESY. IAXO is a large-scale axion helioscope that will look for axions and axion-like particles (ALPs), produced in the Sun, with unprecedented sensitivity. BabyIAXO is conceived to test all IAXO subsystems (magnet, optics and detectors) at a relevant scale for the final system and thus serve as prototype for IAXO, but at the same time as a fully-fledged helioscope with relevant physics reach itself, and with potential for discovery. The BabyIAXO magnet will feature two 10 m long, 70 cm diameter bores, and will host two detection lines (optics and detector) of dimensions similar to the final ones foreseen for IAXO. BabyIAXO will detect or reject solar axions or ALPs with axion-photon couplings down to $g_{aγ} \sim 1.5 \times 10^{-11}$ GeV$^{-1}$, and masses up to $m_a\sim 0.25$ eV. BabyIAXO will offer additional opportunities for axion research in view of IAXO, like the development of precision x-ray detectors to identify particular spectral features in the solar axion spectrum, and the implementation of radiofrequency-cavity-based axion dark matter setups.
△ Less
Submitted 4 March, 2021; v1 submitted 22 October, 2020;
originally announced October 2020.
-
A primary electron beam facility at CERN -- eSPS Conceptual design report
Authors:
M. Aicheler,
T. Akesson,
F. Antoniou,
A. Arnalich,
P. A. Arrutia Sota,
P. Bettencourt Moniz Cabral,
D. Bozzini,
M. Brugger,
O. Brunner,
P. N. Burrows,
R. Calaga,
M. J. Capstick,
R. Corsini,
S. Doebert,
L. A. Dougherty,
Y. Dutheil,
L. A. Dyks,
O. Etisken,
L. Evans,
A. Farricker,
R. Fernandez Ortega,
M. A. Fraser,
J. Gall,
S. J. Gessner,
B. Goddard
, et al. (30 additional authors not shown)
Abstract:
The design of a primary electron beam facility at CERN is described. The study has been carried out within the framework of the wider Physics Beyond Colliders study. It re-enables the Super Proton Synchrotron (SPS) as an electron accelerator, and leverages the development invested in Compact Linear Collider (CLIC) technology for its injector and as an accelerator research and development infrastru…
▽ More
The design of a primary electron beam facility at CERN is described. The study has been carried out within the framework of the wider Physics Beyond Colliders study. It re-enables the Super Proton Synchrotron (SPS) as an electron accelerator, and leverages the development invested in Compact Linear Collider (CLIC) technology for its injector and as an accelerator research and development infrastructure. The facility would be relevant for several of the key priorities in the 2020 update of the European Strategy for Particle Physics, such as an electron-positron Higgs factory, accelerator R\&D, dark sector physics, and neutrino physics. In addition, it could serve experiments in nuclear physics. The electron beam delivered by this facility would provide access to light dark matter production significantly beyond the targets predicted by a thermal dark matter origin, and for natures of dark matter particles that are not accessible by direct detection experiments. It would also enable electro-nuclear measurements crucial for precise modelling the energy dependence of neutrino-nucleus interactions, which is needed to precisely measure neutrino oscillations as a function of energy. The implementation of the facility is the natural next step in the development of X-band high-gradient acceleration technology, a key technology for compact and cost-effective electron/positron linacs. It would also become the only facility with multi-GeV drive bunches and truly independent electron witness bunches for plasma wakefield acceleration. A second phase capable to deliver positron witness bunches would make it a complete facility for plasma wakefield collider studies. [...]
△ Less
Submitted 21 December, 2020; v1 submitted 15 September, 2020;
originally announced September 2020.
-
Scalable haloscopes for axion dark matter detection in the 30$μ$eV range with RADES
Authors:
A. Álvarez Melcón,
S. Arguedas Cuendis,
C. Cogollos,
A. Díaz-Morcillo,
B. Döbrich,
J. D. Gallego,
J. M. García Barceló,
B. Gimeno,
J. Golm,
I. G. Irastorza,
A. J. Lozano-Guerrero,
C. Malbrunot,
A. Millar,
P. Navarro,
C. Peña Garay,
J. Redondo,
W. Wuensch
Abstract:
RADES (Relic Axion Detector Exploratory Setup) is a project with the goal of directly searching for axion dark matter above the $30 μ$eV scale employing custom-made microwave filters in magnetic dipole fields. Currently RADES is taking data at the LHC dipole of the CAST experiment. In the long term, the RADES cavities are envisioned to take data in the (baby)-IAXO magnet. In this article we report…
▽ More
RADES (Relic Axion Detector Exploratory Setup) is a project with the goal of directly searching for axion dark matter above the $30 μ$eV scale employing custom-made microwave filters in magnetic dipole fields. Currently RADES is taking data at the LHC dipole of the CAST experiment. In the long term, the RADES cavities are envisioned to take data in the (baby)-IAXO magnet. In this article we report on the modelling, building and characterisation of an optimised microwave-filter design with alternating irises that exploits maximal coupling to axions while being scalable in length without suffering from mode-mixing. We develop the mathematical formalism and theoretical study which justifies the performance of the chosen design. We also point towards the applicability of this formalism to optimise the MADMAX dielectric haloscopes.
△ Less
Submitted 22 June, 2020; v1 submitted 18 February, 2020;
originally announced February 2020.
-
DC vacuum breakdown in an external magnetic field
Authors:
S. Lebedynskyi,
O. Karpenko,
R. Kholodov,
V. Baturin,
Ia. Profatilova,
N. Shipman,
W. Wuensch
Abstract:
The subject of the present theoretical and experimental investigations is the effect of the external magnetic field induction on dark current and a possibility of breakdown. The generalization of the Fowler-Nordheim equation makes it possible to take into account the influence of a magnetic field parallel to the cathode surface on the field emission current. The reduction in the breakdown voltage…
▽ More
The subject of the present theoretical and experimental investigations is the effect of the external magnetic field induction on dark current and a possibility of breakdown. The generalization of the Fowler-Nordheim equation makes it possible to take into account the influence of a magnetic field parallel to the cathode surface on the field emission current. The reduction in the breakdown voltage due to the increment in electron-impact ionization was theoretical predicted. Experimentally shown that the presence of a magnetic field about a tenth as a large as the cutoff magnetic field [18] reduces the breakdown voltage by 10% to 20% for practically all cathodes no matter what their surface treatment.
△ Less
Submitted 30 September, 2019;
originally announced October 2019.
-
The 3 cavity prototypes of RADES, an axion detector using microwave filters at CAST
Authors:
S. Arguedas Cuendis,
A. Álvarez Melcón,
C. Cogollos,
A. Díaz-Morcillo,
B. Döbrich,
J. D. Gallego,
B. Gimeno,
I. G. Irastorza,
A. J. Lozano-Guerrero,
C. Malbrunot,
P. Navarro,
C. Peña Garay,
J. Redondo,
T. Vafeiadis,
W. Wuensch
Abstract:
The Relic Axion Detector Experimental Setup (RADES) is an axion search project that uses a microwave filter as resonator for Dark Matter conversion. The main focus of this publication is the description of the 3 different cavity prototypes of RADES. The result of the first tests of one of the prototypes is also presented. The filters consist of 5 or 6 stainless steel sub-cavities joined by rectang…
▽ More
The Relic Axion Detector Experimental Setup (RADES) is an axion search project that uses a microwave filter as resonator for Dark Matter conversion. The main focus of this publication is the description of the 3 different cavity prototypes of RADES. The result of the first tests of one of the prototypes is also presented. The filters consist of 5 or 6 stainless steel sub-cavities joined by rectangular irises. The size of the sub-cavities determines the working frequency, the amount of sub-cavities determine the working volume. The first cavity prototype was built in 2017 to work at a frequency of $\sim$ 8.4 GHz and it was placed at the 9 T CAST dipole magnet at CERN. Two more prototypes were designed and built in 2018. The aim of the new designs is to find and test the best cavity geometry in order to scale up in volume and to introduce an effective tuning mechanism. Our results demonstrate the promising potential of this type of filter to reach QCD axion sensitivity at X-Band frequencies.
△ Less
Submitted 11 March, 2019;
originally announced March 2019.
-
Improved Search for Solar Chameleons with a GridPix Detector at CAST
Authors:
V. Anastassopoulos,
S. Aune,
K. Barth,
A. Belov,
H. Bräuninger,
G. Cantatore,
J. M. Carmona,
J. F. Castel,
S. A. Cetin,
F. Christensen,
T. Dafni,
M. Davenport,
A. Dermenev,
K. Desch,
B. Döbrich,
C. Eleftheriadis,
G. Fanourakis,
E. Ferrer-Ribas,
H. Fischer,
W. Funk,
J. A. García,
A. Gardikiotis,
J. G. Garza,
E. N. Gazis,
T. Geralis
, et al. (44 additional authors not shown)
Abstract:
We report on a new search for solar chameleons with the CERN Axion Solar Telescope (CAST). A GridPix detector was used to search for soft X-ray photons in the energy range from 200 eV to 10 keV from converted solar chameleons. No signiffcant excess over the expected background has been observed in the data taken in 2014 and 2015. We set an improved limit on the chameleon photon coupling,…
▽ More
We report on a new search for solar chameleons with the CERN Axion Solar Telescope (CAST). A GridPix detector was used to search for soft X-ray photons in the energy range from 200 eV to 10 keV from converted solar chameleons. No signiffcant excess over the expected background has been observed in the data taken in 2014 and 2015. We set an improved limit on the chameleon photon coupling, $β_γ< 5.7\times10^{10}$ for $1<β_\mathrm{m}<10^6$ at 95% C.L. improving our previous results by a factor two and for the first time reaching sensitivity below the solar luminosity bound for tachocline magnetic fields up to $12.5\,\mathrm{T}$.
△ Less
Submitted 8 November, 2018; v1 submitted 31 July, 2018;
originally announced August 2018.
-
Axion Searches with Microwave Filters: the RADES project
Authors:
Alejandro Álvarez Melcón,
Sergio Arguedas Cuendis,
Cristian Cogollos,
Alejandro Díaz-Morcillo,
Babette Döbrich,
Juan Daniel Gallego,
Benito Gimeno,
Igor G. Irastorza,
Antonio José Lozano-Guerrero,
Chloé Malbrunot,
Pablo Navarro,
Carlos Peña Garay,
Javier Redondo,
Theodoros Vafeiadis,
Walter Wuensch
Abstract:
We propose, design and construct a variant of the conventional axion haloscope concept that could be competitive in the search for dark matter axions of masses in the decade 10-100 $μ$eV. Theses masses are located somewhat above the mass range in which existing experiments have reached sensitivity to benchmark QCD axion models. Our haloscope consists of an array of small microwave cavities connect…
▽ More
We propose, design and construct a variant of the conventional axion haloscope concept that could be competitive in the search for dark matter axions of masses in the decade 10-100 $μ$eV. Theses masses are located somewhat above the mass range in which existing experiments have reached sensitivity to benchmark QCD axion models. Our haloscope consists of an array of small microwave cavities connected by rectangular irises, in an arrangement commonly used in radio-frequency filters. The size of the unit cavity determines the main resonant frequency, while the possibility to connect a {large} number of cavities allows to reach large detection volumes. We develop the theoretical framework of the detection concept, and present design prescriptions to optimize detection capabilities. We describe the design and realization of a first small-scale prototype of this concept, called Relic Axion Detector Exploratory Setup (RADES). It consists of a copper-coated stainless steel five-cavities microwave filter with the detecting mode operating at around 8.4 GHz. This structure has been electromagnetically characterized at 2 K and 298 K, and it is now placed in ultra-high vacuum in one of the twin-bores of the 9 T CAST dipole magnet at CERN. We describe the data acquisition system developed for relic axion detection, and present preliminary results of the electromagnetic properties of the microwave filter, which show the potential of filters to reach QCD axion window sensitivity at X-band frequencies.
△ Less
Submitted 17 May, 2018; v1 submitted 3 March, 2018;
originally announced March 2018.
-
Updated baseline for a staged Compact Linear Collider
Authors:
The CLIC,
CLICdp collaborations,
:,
M. J. Boland,
U. Felzmann,
P. J. Giansiracusa,
T. G. Lucas,
R. P. Rassool,
C. Balazs,
T. K. Charles,
K. Afanaciev,
I. Emeliantchik,
A. Ignatenko,
V. Makarenko,
N. Shumeiko,
A. Patapenka,
I. Zhuk,
A. C. Abusleme Hoffman,
M. A. Diaz Gutierrez,
M. Vogel Gonzalez,
Y. Chi,
X. He,
G. Pei,
S. Pei,
G. Shu
, et al. (493 additional authors not shown)
Abstract:
The Compact Linear Collider (CLIC) is a multi-TeV high-luminosity linear e+e- collider under development. For an optimal exploitation of its physics potential, CLIC is foreseen to be built and operated in a staged approach with three centre-of-mass energy stages ranging from a few hundred GeV up to 3 TeV. The first stage will focus on precision Standard Model physics, in particular Higgs and top-q…
▽ More
The Compact Linear Collider (CLIC) is a multi-TeV high-luminosity linear e+e- collider under development. For an optimal exploitation of its physics potential, CLIC is foreseen to be built and operated in a staged approach with three centre-of-mass energy stages ranging from a few hundred GeV up to 3 TeV. The first stage will focus on precision Standard Model physics, in particular Higgs and top-quark measurements. Subsequent stages will focus on measurements of rare Higgs processes, as well as searches for new physics processes and precision measurements of new states, e.g. states previously discovered at LHC or at CLIC itself. In the 2012 CLIC Conceptual Design Report, a fully optimised 3 TeV collider was presented, while the proposed lower energy stages were not studied to the same level of detail. This report presents an updated baseline staging scenario for CLIC. The scenario is the result of a comprehensive study addressing the performance, cost and power of the CLIC accelerator complex as a function of centre-of-mass energy and it targets optimal physics output based on the current physics landscape. The optimised staging scenario foresees three main centre-of-mass energy stages at 380 GeV, 1.5 TeV and 3 TeV for a full CLIC programme spanning 22 years. For the first stage, an alternative to the CLIC drive beam scheme is presented in which the main linac power is produced using X-band klystrons.
△ Less
Submitted 27 March, 2017; v1 submitted 26 August, 2016;
originally announced August 2016.