-
XENONnT WIMP Search: Signal & Background Modeling and Statistical Inference
Authors:
XENON Collaboration,
E. Aprile,
J. Aalbers,
K. Abe,
S. Ahmed Maouloud,
L. Althueser,
B. Andrieu,
E. Angelino,
D. Antón Martin,
F. Arneodo,
L. Baudis,
M. Bazyk,
L. Bellagamba,
R. Biondi,
A. Bismark,
K. Boese,
A. Brown,
G. Bruno,
R. Budnik,
J. M. R. Cardoso,
A. P. Cimental Chávez,
A. P. Colijn,
J. Conrad,
J. J. Cuenca-García,
V. D'Andrea
, et al. (139 additional authors not shown)
Abstract:
The XENONnT experiment searches for weakly-interacting massive particle (WIMP) dark matter scattering off a xenon nucleus. In particular, XENONnT uses a dual-phase time projection chamber with a 5.9-tonne liquid xenon target, detecting both scintillation and ionization signals to reconstruct the energy, position, and type of recoil. A blind search for nuclear recoil WIMPs with an exposure of 1.1 t…
▽ More
The XENONnT experiment searches for weakly-interacting massive particle (WIMP) dark matter scattering off a xenon nucleus. In particular, XENONnT uses a dual-phase time projection chamber with a 5.9-tonne liquid xenon target, detecting both scintillation and ionization signals to reconstruct the energy, position, and type of recoil. A blind search for nuclear recoil WIMPs with an exposure of 1.1 tonne-years yielded no signal excess over background expectations, from which competitive exclusion limits were derived on WIMP-nucleon elastic scatter cross sections, for WIMP masses ranging from 6 GeV/$c^2$ up to the TeV/$c^2$ scale. This work details the modeling and statistical methods employed in this search. By means of calibration data, we model the detector response, which is then used to derive background and signal models. The construction and validation of these models is discussed, alongside additional purely data-driven backgrounds. We also describe the statistical inference framework, including the definition of the likelihood function and the construction of confidence intervals.
△ Less
Submitted 19 June, 2024;
originally announced June 2024.
-
Offline tagging of radon-induced backgrounds in XENON1T and applicability to other liquid xenon detectors
Authors:
E. Aprile,
J. Aalbers,
K. Abe,
S. Ahmed Maouloud,
L. Althueser,
B. Andrieu,
E. Angelino,
J. R. Angevaare,
D. Antón Martin,
F. Arneodo,
L. Baudis,
A. L. Baxter,
M. Bazyk,
L. Bellagamba,
R. Biondi,
A. Bismark,
E. J. Brookes,
A. Brown,
G. Bruno,
R. Budnik,
T. K. Bui,
J. M. R. Cardoso,
A. P. Cimental Chavez,
A. P. Colijn,
J. Conrad
, et al. (142 additional authors not shown)
Abstract:
This paper details the first application of a software tagging algorithm to reduce radon-induced backgrounds in liquid noble element time projection chambers, such as XENON1T and XENONnT. The convection velocity field in XENON1T was mapped out using $^{222}\text{Rn}$ and $^{218}\text{Po}$ events, and the root-mean-square convection speed was measured to be $0.30 \pm 0.01$ cm/s. Given this velocity…
▽ More
This paper details the first application of a software tagging algorithm to reduce radon-induced backgrounds in liquid noble element time projection chambers, such as XENON1T and XENONnT. The convection velocity field in XENON1T was mapped out using $^{222}\text{Rn}$ and $^{218}\text{Po}$ events, and the root-mean-square convection speed was measured to be $0.30 \pm 0.01$ cm/s. Given this velocity field, $^{214}\text{Pb}$ background events can be tagged when they are followed by $^{214}\text{Bi}$ and $^{214}\text{Po}$ decays, or preceded by $^{218}\text{Po}$ decays. This was achieved by evolving a point cloud in the direction of a measured convection velocity field, and searching for $^{214}\text{Bi}$ and $^{214}\text{Po}$ decays or $^{218}\text{Po}$ decays within a volume defined by the point cloud. In XENON1T, this tagging system achieved a $^{214}\text{Pb}$ background reduction of $6.2^{+0.4}_{-0.9}\%$ with an exposure loss of $1.8\pm 0.2 \%$, despite the timescales of convection being smaller than the relevant decay times. We show that the performance can be improved in XENONnT, and that the performance of such a software-tagging approach can be expected to be further improved in a diffusion-limited scenario. Finally, a similar method might be useful to tag the cosmogenic $^{137}\text{Xe}$ background, which is relevant to the search for neutrinoless double-beta decay.
△ Less
Submitted 19 June, 2024; v1 submitted 21 March, 2024;
originally announced March 2024.
-
The XENONnT Dark Matter Experiment
Authors:
XENON Collaboration,
E. Aprile,
J. Aalbers,
K. Abe,
S. Ahmed Maouloud,
L. Althueser,
B. Andrieu,
E. Angelino,
J. R. Angevaare,
V. C. Antochi,
D. Antón Martin,
F. Arneodo,
M. Balata,
L. Baudis,
A. L. Baxter,
M. Bazyk,
L. Bellagamba,
R. Biondi,
A. Bismark,
E. J. Brookes,
A. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
T. K. Bui
, et al. (170 additional authors not shown)
Abstract:
The multi-staged XENON program at INFN Laboratori Nazionali del Gran Sasso aims to detect dark matter with two-phase liquid xenon time projection chambers of increasing size and sensitivity. The XENONnT experiment is the latest detector in the program, planned to be an upgrade of its predecessor XENON1T. It features an active target of 5.9 tonnes of cryogenic liquid xenon (8.5 tonnes total mass in…
▽ More
The multi-staged XENON program at INFN Laboratori Nazionali del Gran Sasso aims to detect dark matter with two-phase liquid xenon time projection chambers of increasing size and sensitivity. The XENONnT experiment is the latest detector in the program, planned to be an upgrade of its predecessor XENON1T. It features an active target of 5.9 tonnes of cryogenic liquid xenon (8.5 tonnes total mass in cryostat). The experiment is expected to extend the sensitivity to WIMP dark matter by more than an order of magnitude compared to XENON1T, thanks to the larger active mass and the significantly reduced background, improved by novel systems such as a radon removal plant and a neutron veto. This article describes the XENONnT experiment and its sub-systems in detail and reports on the detector performance during the first science run.
△ Less
Submitted 15 February, 2024;
originally announced February 2024.
-
Optimum filter-based analysis for the characterization of a high-resolution magnetic microcalorimeter towards the DELight experiment
Authors:
Francesco Toschi,
Benedikt Maier,
Greta Heine,
Torben Ferber,
Sebastian Kempf,
Markus Klute,
Belina von Krosigk
Abstract:
Ultra-sensitive cryogenic calorimeters have become a favored technology with widespread application where eV-scale energy resolutions are needed. In this article, we characterize the performance of an X-ray magnetic microcalorimeter (MMC) using a Fe-55 source. Employing an optimum filter-based amplitude estimation and energy reconstruction, we demonstrate that an unprecedented FWHM resolution of…
▽ More
Ultra-sensitive cryogenic calorimeters have become a favored technology with widespread application where eV-scale energy resolutions are needed. In this article, we characterize the performance of an X-ray magnetic microcalorimeter (MMC) using a Fe-55 source. Employing an optimum filter-based amplitude estimation and energy reconstruction, we demonstrate that an unprecedented FWHM resolution of $ΔE_\mathrm{FWHM} = \left(1.25\pm0.17\mathrm{\scriptsize{(stat)}}^{+0.05}_{-0.07}\mathrm{\scriptsize{(syst)}}\right)\,\text{eV}$ can be achieved. We also derive the best possible resolution and discuss limiting factors affecting the measurement. The analysis pipeline for the MMC data developed in this paper is furthermore an important step for the realization of the proposed superfluid helium-based experiment DELight, which will search for direct interaction of dark matter with masses below 100 MeV/c$^2$.
△ Less
Submitted 12 October, 2023;
originally announced October 2023.
-
Design and performance of the field cage for the XENONnT experiment
Authors:
E. Aprile,
K. Abe,
S. Ahmed Maouloud,
L. Althueser,
B. Andrieu,
E. Angelino,
J. R. Angevaare,
V. C. Antochi,
D. Antón Martin,
F. Arneodo,
L. Baudis,
A. L. Baxter,
M. Bazyk,
L. Bellagamba,
R. Biondi,
A. Bismark,
E. J. Brookes,
A. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
T. K. Bui,
C. Cai,
J. M. R. Cardoso,
D. Cichon
, et al. (139 additional authors not shown)
Abstract:
The precision in reconstructing events detected in a dual-phase time projection chamber depends on an homogeneous and well understood electric field within the liquid target. In the XENONnT TPC the field homogeneity is achieved through a double-array field cage, consisting of two nested arrays of field sha** rings connected by an easily accessible resistor chain. Rather than being connected to t…
▽ More
The precision in reconstructing events detected in a dual-phase time projection chamber depends on an homogeneous and well understood electric field within the liquid target. In the XENONnT TPC the field homogeneity is achieved through a double-array field cage, consisting of two nested arrays of field sha** rings connected by an easily accessible resistor chain. Rather than being connected to the gate electrode, the topmost field sha** ring is independently biased, adding a degree of freedom to tune the electric field during operation. Two-dimensional finite element simulations were used to optimize the field cage, as well as its operation. Simulation results were compared to ${}^{83m}\mathrm{Kr}$ calibration data. This comparison indicates an accumulation of charge on the panels of the TPC which is constant over time, as no evolution of the reconstructed position distribution of events is observed. The simulated electric field was then used to correct the charge signal for the field dependence of the charge yield. This correction resolves the inconsistent measurement of the drift electron lifetime when using different calibrations sources and different field cage tuning voltages.
△ Less
Submitted 21 September, 2023;
originally announced September 2023.
-
Search for events in XENON1T associated with Gravitational Waves
Authors:
XENON Collaboration,
E. Aprile,
K. Abe,
S. Ahmed Maouloud,
L. Althueser,
B. Andrieu,
E. Angelino,
J. R. Angevaare,
V. C. Antochi,
D. Antoń Martin,
F. Arneodo,
L. Baudis,
A. L. Baxter,
M. Bazyk,
L. Bellagamba,
R. Biondi,
A. Bismark,
E. J. Brookes,
A. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
T. K. Bui,
C. Cai,
J. M. R. Cardoso
, et al. (138 additional authors not shown)
Abstract:
We perform a blind search for particle signals in the XENON1T dark matter detector that occur close in time to gravitational wave signals in the LIGO and Virgo observatories. No particle signal is observed in the nuclear recoil, electronic recoil, CE$ν$NS, and S2-only channels within $\pm$ 500 seconds of observations of the gravitational wave signals GW170104, GW170729, GW170817, GW170818, and GW1…
▽ More
We perform a blind search for particle signals in the XENON1T dark matter detector that occur close in time to gravitational wave signals in the LIGO and Virgo observatories. No particle signal is observed in the nuclear recoil, electronic recoil, CE$ν$NS, and S2-only channels within $\pm$ 500 seconds of observations of the gravitational wave signals GW170104, GW170729, GW170817, GW170818, and GW170823. We use this null result to constrain mono-energetic neutrinos and Beyond Standard Model particles emitted in the closest coalescence GW170817, a binary neutron star merger. We set new upper limits on the fluence (time-integrated flux) of coincident neutrinos down to 17 keV at 90% confidence level. Furthermore, we constrain the product of coincident fluence and cross section of Beyond Standard Model particles to be less than $10^{-29}$ cm$^2$/cm$^2$ in the [5.5-210] keV energy range at 90% confidence level.
△ Less
Submitted 27 October, 2023; v1 submitted 20 June, 2023;
originally announced June 2023.
-
Searching for Heavy Dark Matter near the Planck Mass with XENON1T
Authors:
E. Aprile,
K. Abe,
S. Ahmed Maouloud,
L. Althueser,
B. Andrieu,
E. Angelino,
J. R. Angevaare,
V. C. Antochi,
D. Antón Martin,
F. Arneodo,
L. Baudis,
A. L. Baxter,
M. Bazyk,
L. Bellagamba,
R. Biondi,
A. Bismark,
E. J. Brookes,
A. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
T. K. Bui,
C. Cai,
J. M. R. Cardoso,
D. Cichon
, et al. (142 additional authors not shown)
Abstract:
Multiple viable theoretical models predict heavy dark matter particles with a mass close to the Planck mass, a range relatively unexplored by current experimental measurements. We use 219.4 days of data collected with the XENON1T experiment to conduct a blind search for signals from Multiply-Interacting Massive Particles (MIMPs). Their unique track signature allows a targeted analysis with only 0.…
▽ More
Multiple viable theoretical models predict heavy dark matter particles with a mass close to the Planck mass, a range relatively unexplored by current experimental measurements. We use 219.4 days of data collected with the XENON1T experiment to conduct a blind search for signals from Multiply-Interacting Massive Particles (MIMPs). Their unique track signature allows a targeted analysis with only 0.05 expected background events from muons. Following unblinding, we observe no signal candidate events. This work places strong constraints on spin-independent interactions of dark matter particles with a mass between 1$\times$10$^{12}\,$GeV/c$^2$ and 2$\times$10$^{17}\,$GeV/c$^2$. In addition, we present the first exclusion limits on spin-dependent MIMP-neutron and MIMP-proton cross-sections for dark matter particles with masses close to the Planck scale.
△ Less
Submitted 21 April, 2023;
originally announced April 2023.
-
Detector signal characterization with a Bayesian network in XENONnT
Authors:
XENON Collaboration,
E. Aprile,
K. Abe,
S. Ahmed Maouloud,
L. Althueser,
B. Andrieu,
E. Angelino,
J. R. Angevaare,
V. C. Antochi,
D. Antón Martin,
F. Arneodo,
L. Baudis,
A. L. Baxter,
M. Bazyk,
L. Bellagamba,
R. Biondi,
A. Bismark,
E. J. Brookes,
A. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
T. K. Bui,
C. Cai,
J. M. R. Cardoso
, et al. (142 additional authors not shown)
Abstract:
We developed a detector signal characterization model based on a Bayesian network trained on the waveform attributes generated by a dual-phase xenon time projection chamber. By performing inference on the model, we produced a quantitative metric of signal characterization and demonstrate that this metric can be used to determine whether a detector signal is sourced from a scintillation or an ioniz…
▽ More
We developed a detector signal characterization model based on a Bayesian network trained on the waveform attributes generated by a dual-phase xenon time projection chamber. By performing inference on the model, we produced a quantitative metric of signal characterization and demonstrate that this metric can be used to determine whether a detector signal is sourced from a scintillation or an ionization process. We describe the method and its performance on electronic-recoil (ER) data taken during the first science run of the XENONnT dark matter experiment. We demonstrate the first use of a Bayesian network in a waveform-based analysis of detector signals. This method resulted in a 3% increase in ER event-selection efficiency with a simultaneously effective rejection of events outside of the region of interest. The findings of this analysis are consistent with the previous analysis from XENONnT, namely a background-only fit of the ER data.
△ Less
Submitted 26 July, 2023; v1 submitted 11 April, 2023;
originally announced April 2023.
-
First Dark Matter Search with Nuclear Recoils from the XENONnT Experiment
Authors:
XENON Collaboration,
E. Aprile,
K. Abe,
F. Agostini,
S. Ahmed Maouloud,
L. Althueser,
B. Andrieu,
E. Angelino,
J. R. Angevaare,
V. C. Antochi,
D. Antón Martin,
F. Arneodo,
L. Baudis,
A. L. Baxter,
M. Bazyk,
L. Bellagamba,
R. Biondi,
A. Bismark,
E. J. Brookes,
A. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
T. K. Bui,
C. Cai
, et al. (141 additional authors not shown)
Abstract:
We report on the first search for nuclear recoils from dark matter in the form of weakly interacting massive particles (WIMPs) with the XENONnT experiment which is based on a two-phase time projection chamber with a sensitive liquid xenon mass of $5.9$ t. During the approximately 1.1 tonne-year exposure used for this search, the intrinsic $^{85}$Kr and $^{222}$Rn concentrations in the liquid targe…
▽ More
We report on the first search for nuclear recoils from dark matter in the form of weakly interacting massive particles (WIMPs) with the XENONnT experiment which is based on a two-phase time projection chamber with a sensitive liquid xenon mass of $5.9$ t. During the approximately 1.1 tonne-year exposure used for this search, the intrinsic $^{85}$Kr and $^{222}$Rn concentrations in the liquid target were reduced to unprecedentedly low levels, giving an electronic recoil background rate of $(15.8\pm1.3)~\mathrm{events}/(\mathrm{t\cdot y \cdot keV})$ in the region of interest. A blind analysis of nuclear recoil events with energies between $3.3$ keV and $60.5$ keV finds no significant excess. This leads to a minimum upper limit on the spin-independent WIMP-nucleon cross section of $2.58\times 10^{-47}~\mathrm{cm}^2$ for a WIMP mass of $28~\mathrm{GeV}/c^2$ at $90\%$ confidence level. Limits for spin-dependent interactions are also provided. Both the limit and the sensitivity for the full range of WIMP masses analyzed here improve on previous results obtained with the XENON1T experiment for the same exposure.
△ Less
Submitted 5 August, 2023; v1 submitted 26 March, 2023;
originally announced March 2023.
-
The Triggerless Data Acquisition System of the XENONnT Experiment
Authors:
E. Aprile,
J. Aalbers,
K. Abe,
F. Agostini,
S. Ahmed Maouloud,
L. Althueser,
B. Andrieu,
E. Angelino,
J. R. Angevaare,
V. C. Antochi,
D. Antón Martin,
F. Arneodo,
L. Baudis,
A. L. Baxter,
L. Bellagamba,
R. Biondi,
A. Bismark,
E. J. Brookes,
A. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
T. K. Bui,
C. Cai,
J. M. R. Cardoso
, et al. (140 additional authors not shown)
Abstract:
The XENONnT detector uses the latest and largest liquid xenon-based time projection chamber (TPC) operated by the XENON Collaboration, aimed at detecting Weakly Interacting Massive Particles and conducting other rare event searches. The XENONnT data acquisition (DAQ) system constitutes an upgraded and expanded version of the XENON1T DAQ system. For its operation, it relies predominantly on commerc…
▽ More
The XENONnT detector uses the latest and largest liquid xenon-based time projection chamber (TPC) operated by the XENON Collaboration, aimed at detecting Weakly Interacting Massive Particles and conducting other rare event searches. The XENONnT data acquisition (DAQ) system constitutes an upgraded and expanded version of the XENON1T DAQ system. For its operation, it relies predominantly on commercially available hardware accompanied by open-source and custom-developed software. The three constituent subsystems of the XENONnT detector, the TPC (main detector), muon veto, and the newly introduced neutron veto, are integrated into a single DAQ, and can be operated both independently and as a unified system. In total, the DAQ digitizes the signals of 698 photomultiplier tubes (PMTs), of which 253 from the top PMT array of the TPC are digitized twice, at $\times10$ and $\times0.5$ gain. The DAQ for the most part is a triggerless system, reading out and storing every signal that exceeds the digitization thresholds. Custom-developed software is used to process the acquired data, making it available within $\mathcal{O}\left(10\text{ s}\right)$ for live data quality monitoring and online analyses. The entire system with all the three subsystems was successfully commissioned and has been operating continuously, comfortably withstanding readout rates that exceed $\sim500$ MB/s during calibration. Livetime during normal operation exceeds $99\%$ and is $\sim90\%$ during most high-rate calibrations. The combined DAQ system has collected more than 2 PB of both calibration and science data during the commissioning of XENONnT and the first science run.
△ Less
Submitted 21 December, 2022;
originally announced December 2022.
-
Low-energy Calibration of XENON1T with an Internal $^{37}$Ar Source
Authors:
E. Aprile,
K. Abe,
F. Agostini,
S. Ahmed Maouloud,
M. Alfonsi,
L. Althueser,
B. Andrieu,
E. Angelino,
J. R. Angevaare,
V. C. Antochi,
D. Antón Martin,
F. Arneodo,
L. Baudis,
A. L. Baxter,
L. Bellagamba,
R. Biondi,
A. Bismark,
A. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
T. K. Bui,
C. Cai,
C. Capelli,
J. M. R. Cardoso
, et al. (139 additional authors not shown)
Abstract:
A low-energy electronic recoil calibration of XENON1T, a dual-phase xenon time projection chamber, with an internal $^{37}$Ar source was performed. This calibration source features a 35-day half-life and provides two mono-energetic lines at 2.82 keV and 0.27 keV. The photon yield and electron yield at 2.82 keV are measured to be (32.3$\pm$0.3) photons/keV and (40.6$\pm$0.5) electrons/keV, respecti…
▽ More
A low-energy electronic recoil calibration of XENON1T, a dual-phase xenon time projection chamber, with an internal $^{37}$Ar source was performed. This calibration source features a 35-day half-life and provides two mono-energetic lines at 2.82 keV and 0.27 keV. The photon yield and electron yield at 2.82 keV are measured to be (32.3$\pm$0.3) photons/keV and (40.6$\pm$0.5) electrons/keV, respectively, in agreement with other measurements and with NEST predictions. The electron yield at 0.27 keV is also measured and it is (68.0$^{+6.3}_{-3.7}$) electrons/keV. The $^{37}$Ar calibration confirms that the detector is well-understood in the energy region close to the detection threshold, with the 2.82 keV line reconstructed at (2.83$\pm$0.02) keV, which further validates the model used to interpret the low-energy electronic recoil excess previously reported by XENON1T. The ability to efficiently remove argon with cryogenic distillation after the calibration proves that $^{37}$Ar can be considered as a regular calibration source for multi-tonne xenon detectors.
△ Less
Submitted 21 March, 2023; v1 submitted 25 November, 2022;
originally announced November 2022.
-
Effective Field Theory and Inelastic Dark Matter Results from XENON1T
Authors:
E. Aprile,
K. Abe,
F. Agostini,
S. Ahmed Maouloud,
L. Althueser,
B. Andrieu,
E. Angelino,
J. R. Angevaare,
V. C. Antochi,
D. Antón Martin,
F. Arneodo,
L. Baudis,
A. L. Baxter,
L. Bellagamba,
R. Biondi,
A. Bismark,
A. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
C. Cai,
C. Capelli,
J. M. R. Cardoso,
D. Cichon,
M. Clark
, et al. (135 additional authors not shown)
Abstract:
In this work, we expand on the XENON1T nuclear recoil searches to study the individual signals of dark matter interactions from operators up to dimension-eight in a Chiral Effective Field Theory (ChEFT) and a model of inelastic dark matter (iDM). We analyze data from two science runs of the XENON1T detector totaling 1\,tonne$\times$year exposure. For these analyses, we extended the region of inter…
▽ More
In this work, we expand on the XENON1T nuclear recoil searches to study the individual signals of dark matter interactions from operators up to dimension-eight in a Chiral Effective Field Theory (ChEFT) and a model of inelastic dark matter (iDM). We analyze data from two science runs of the XENON1T detector totaling 1\,tonne$\times$year exposure. For these analyses, we extended the region of interest from [4.9, 40.9]$\,$keV$_{\text{NR}}$ to [4.9, 54.4]$\,$keV$_{\text{NR}}$ to enhance our sensitivity for signals that peak at nonzero energies. We show that the data is consistent with the background-only hypothesis, with a small background over-fluctuation observed peaking between 20 and 50$\,$keV$_{\text{NR}}$, resulting in a maximum local discovery significance of 1.7\,$σ$ for the Vector$\otimes$Vector$_{\text{strange}}$ ($VV_s$) ChEFT channel for a dark matter particle of 70$\,$GeV/c$^2$, and $1.8\,σ$ for an iDM particle of 50$\,$GeV/c$^2$ with a mass splitting of 100$\,$keV/c$^2$. For each model, we report 90\,\% confidence level (CL) upper limits. We also report upper limits on three benchmark models of dark matter interaction using ChEFT where we investigate the effect of isospin-breaking interactions. We observe rate-driven cancellations in regions of the isospin-breaking couplings, leading to up to 6 orders of magnitude weaker upper limits with respect to the isospin-conserving case.
△ Less
Submitted 17 October, 2022; v1 submitted 14 October, 2022;
originally announced October 2022.
-
An approximate likelihood for nuclear recoil searches with XENON1T data
Authors:
E. Aprile,
K. Abe,
F. Agostini,
S. Ahmed Maouloud,
M. Alfonsi,
L. Althueser,
B. Andrieu,
E. Angelino,
J. R. Angevaare,
V. C. Antochi,
D. Antón Martin,
F. Arneodo,
L. Baudis,
A. L. Baxter,
L. Bellagamba,
R. Biondi,
A. Bismark,
A. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
C. Capelli,
J. M. R. Cardoso,
D. Cichon,
B. Cimmino
, et al. (129 additional authors not shown)
Abstract:
The XENON collaboration has published stringent limits on specific dark matter -nucleon recoil spectra from dark matter recoiling on the liquid xenon detector target. In this paper, we present an approximate likelihood for the XENON1T 1 tonne-year nuclear recoil search applicable to any nuclear recoil spectrum. Alongside this paper, we publish data and code to compute upper limits using the method…
▽ More
The XENON collaboration has published stringent limits on specific dark matter -nucleon recoil spectra from dark matter recoiling on the liquid xenon detector target. In this paper, we present an approximate likelihood for the XENON1T 1 tonne-year nuclear recoil search applicable to any nuclear recoil spectrum. Alongside this paper, we publish data and code to compute upper limits using the method we present. The approximate likelihood is constructed in bins of reconstructed energy, profiled along the signal expectation in each bin. This approach can be used to compute an approximate likelihood and therefore most statistical results for any nuclear recoil spectrum. Computing approximate results with this method is approximately three orders of magnitude faster than the likelihood used in the original publications of XENON1T, where limits were set for specific families of recoil spectra. Using this same method, we include toy Monte Carlo simulation-derived binwise likelihoods for the upcoming XENONnT experiment that can similarly be used to assess the sensitivity to arbitrary nuclear recoil signatures in its eventual 20 tonne-year exposure.
△ Less
Submitted 13 October, 2022;
originally announced October 2022.
-
DELight: a Direct search Experiment for Light dark matter with superfluid helium
Authors:
Belina von Krosigk,
Klaus Eitel,
Christian Enss,
Torben Ferber,
Loredana Gastaldo,
Felix Kahlhoefer,
Sebastian Kempf,
Markus Klute,
Sebastian Lindemann,
Marc Schumann,
Francesco Toschi,
Kathrin Valerius
Abstract:
To reach ultra-low detection thresholds necessary to probe unprecedentedly low Dark Matter masses, target material alternatives and novel detector designs are essential. One such target material is superfluid $^4$He which has the potential to probe so far uncharted light Dark Matter parameter space at sub-GeV masses. The new ``Direct search Experiment for Light dark matter'', DELight, will be usin…
▽ More
To reach ultra-low detection thresholds necessary to probe unprecedentedly low Dark Matter masses, target material alternatives and novel detector designs are essential. One such target material is superfluid $^4$He which has the potential to probe so far uncharted light Dark Matter parameter space at sub-GeV masses. The new ``Direct search Experiment for Light dark matter'', DELight, will be using superfluid helium as active target, instrumented with magnetic micro-calorimeters. It is being designed to reach sensitivity to masses well below 100\,MeV in Dark Matter-nucleus scattering interactions.
△ Less
Submitted 22 September, 2022;
originally announced September 2022.
-
Search for New Physics in Electronic Recoil Data from XENONnT
Authors:
E. Aprile,
K. Abe,
F. Agostini,
S. Ahmed Maouloud,
L. Althueser,
B. Andrieu,
E. Angelino,
J. R. Angevaare,
V. C. Antochi,
D. Antón Martin,
F. Arneodo,
L. Baudis,
A. L. Baxter,
L. Bellagamba,
R. Biondi,
A. Bismark,
A. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
T. K. Bui,
C. Cai,
C. Capelli,
J. M. R. Cardoso,
D. Cichon
, et al. (141 additional authors not shown)
Abstract:
We report on a blinded analysis of low-energy electronic-recoil data from the first science run of the XENONnT dark matter experiment. Novel subsystems and the increased 5.9 tonne liquid xenon target reduced the background in the (1, 30) keV search region to $(15.8 \pm 1.3)$ events/(tonne$\times$year$\times$keV), the lowest ever achieved in a dark matter detector and $\sim$5 times lower than in XE…
▽ More
We report on a blinded analysis of low-energy electronic-recoil data from the first science run of the XENONnT dark matter experiment. Novel subsystems and the increased 5.9 tonne liquid xenon target reduced the background in the (1, 30) keV search region to $(15.8 \pm 1.3)$ events/(tonne$\times$year$\times$keV), the lowest ever achieved in a dark matter detector and $\sim$5 times lower than in XENON1T. With an exposure of 1.16 tonne-years, we observe no excess above background and set stringent new limits on solar axions, an enhanced neutrino magnetic moment, and bosonic dark matter.
△ Less
Submitted 15 November, 2022; v1 submitted 22 July, 2022;
originally announced July 2022.
-
Double-Weak Decays of $^{124}$Xe and $^{136}$Xe in the XENON1T and XENONnT Experiments
Authors:
E. Aprile,
K. Abe,
F. Agostini,
S. Ahmed Maouloud,
M. Alfonsi,
L. Althueser,
B. Andrieu,
E. Angelino,
J. R. Angevaare,
V. C. Antochi,
D. Antón Martin,
F. Arneodo,
L. Baudis,
A. L. Baxter,
L. Bellagamba,
R. Biondi,
A. Bismark,
A. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
C. Cai,
C. Capelli,
J. M. R. Cardoso,
D. Cichon
, et al. (135 additional authors not shown)
Abstract:
We present results on the search for double-electron capture ($2ν\text{ECEC}$) of $^{124}$Xe and neutrinoless double-$β$ decay ($0νββ$) of $^{136}$Xe in XENON1T. We consider captures from the K- up to the N-shell in the $2ν\text{ECEC}$ signal model and measure a total half-life of $T_{1/2}^{2ν\text{ECEC}}=(1.1\pm0.2_\text{stat}\pm0.1_\text{sys})\times 10^{22}\;\text{yr}$ with a…
▽ More
We present results on the search for double-electron capture ($2ν\text{ECEC}$) of $^{124}$Xe and neutrinoless double-$β$ decay ($0νββ$) of $^{136}$Xe in XENON1T. We consider captures from the K- up to the N-shell in the $2ν\text{ECEC}$ signal model and measure a total half-life of $T_{1/2}^{2ν\text{ECEC}}=(1.1\pm0.2_\text{stat}\pm0.1_\text{sys})\times 10^{22}\;\text{yr}$ with a $0.87\;\text{kg}\times\text{yr}$ isotope exposure. The statistical significance of the signal is $7.0\,σ$. We use XENON1T data with $36.16\;\text{kg}\times\text{yr}$ of $^{136}$Xe exposure to search for $0νββ$. We find no evidence of a signal and set a lower limit on the half-life of $T_{1/2}^{0νββ} > 1.2 \times 10^{24}\;\text{yr}\; \text{at}\; 90\,\%\;\text{CL}$. This is the best result from a dark matter detector without an enriched target to date. We also report projections on the sensitivity of XENONnT to $0νββ$. Assuming a $275\;\text{kg}\times\text{yr}$ $^{136}$Xe exposure, the expected sensitivity is $T_{1/2}^{0νββ} > 2.1 \times 10^{25}\;\text{yr}\; \text{at}\; 90\,\%\;\text{CL}$, corresponding to an effective Majorana mass range of $\langle m_{ββ} \rangle < (0.19 - 0.59)\;\text{eV/c}^2$.
△ Less
Submitted 6 September, 2022; v1 submitted 9 May, 2022;
originally announced May 2022.
-
A Next-Generation Liquid Xenon Observatory for Dark Matter and Neutrino Physics
Authors:
J. Aalbers,
K. Abe,
V. Aerne,
F. Agostini,
S. Ahmed Maouloud,
D. S. Akerib,
D. Yu. Akimov,
J. Akshat,
A. K. Al Musalhi,
F. Alder,
S. K. Alsum,
L. Althueser,
C. S. Amarasinghe,
F. D. Amaro,
A. Ames,
T. J. Anderson,
B. Andrieu,
N. Angelides,
E. Angelino,
J. Angevaare,
V. C. Antochi,
D. Antón Martin,
B. Antunovic,
E. Aprile,
H. M. Araújo
, et al. (572 additional authors not shown)
Abstract:
The nature of dark matter and properties of neutrinos are among the most pressing issues in contemporary particle physics. The dual-phase xenon time-projection chamber is the leading technology to cover the available parameter space for Weakly Interacting Massive Particles (WIMPs), while featuring extensive sensitivity to many alternative dark matter candidates. These detectors can also study neut…
▽ More
The nature of dark matter and properties of neutrinos are among the most pressing issues in contemporary particle physics. The dual-phase xenon time-projection chamber is the leading technology to cover the available parameter space for Weakly Interacting Massive Particles (WIMPs), while featuring extensive sensitivity to many alternative dark matter candidates. These detectors can also study neutrinos through neutrinoless double-beta decay and through a variety of astrophysical sources. A next-generation xenon-based detector will therefore be a true multi-purpose observatory to significantly advance particle physics, nuclear physics, astrophysics, solar physics, and cosmology. This review article presents the science cases for such a detector.
△ Less
Submitted 4 March, 2022;
originally announced March 2022.
-
Application and modeling of an online distillation method to reduce krypton and argon in XENON1T
Authors:
E. Aprile,
K. Abe,
F. Agostini,
S. Ahmed Maouloud,
M. Alfonsi,
L. Althueser,
E. Angelino,
J. R. Angevaare,
V. C. Antochi,
D. Antón Martin,
F. Arneodo,
L. Baudis,
A. L. Baxter,
L. Bellagamba,
A. Bernard,
R. Biondi,
A. Bismark,
A. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
C. Capelli,
J. M. R. Cardoso,
D. Cichon,
B. Cimmino
, et al. (129 additional authors not shown)
Abstract:
A novel online distillation technique was developed for the XENON1T dark matter experiment to reduce intrinsic background components more volatile than xenon, such as krypton or argon, while the detector was operating. The method is based on a continuous purification of the gaseous volume of the detector system using the XENON1T cryogenic distillation column. A krypton-in-xenon concentration of…
▽ More
A novel online distillation technique was developed for the XENON1T dark matter experiment to reduce intrinsic background components more volatile than xenon, such as krypton or argon, while the detector was operating. The method is based on a continuous purification of the gaseous volume of the detector system using the XENON1T cryogenic distillation column. A krypton-in-xenon concentration of $(360 \pm 60)$ ppq was achieved. It is the lowest concentration measured in the fiducial volume of an operating dark matter detector to date. A model was developed and fit to the data to describe the krypton evolution in the liquid and gas volumes of the detector system for several operation modes over the time span of 550 days, including the commissioning and science runs of XENON1T. The online distillation was also successfully applied to remove Ar-37 after its injection for a low energy calibration in XENON1T. This makes the usage of Ar-37 as a regular calibration source possible in the future. The online distillation can be applied to next-generation experiments to remove krypton prior to, or during, any science run. The model developed here allows further optimization of the distillation strategy for future large scale detectors.
△ Less
Submitted 14 June, 2022; v1 submitted 22 December, 2021;
originally announced December 2021.
-
Emission of Single and Few Electrons in XENON1T and Limits on Light Dark Matter
Authors:
E. Aprile,
K. Abe,
F. Agostini,
S. Ahmed Maouloud,
M. Alfonsi,
L. Althueser,
E. Angelino,
J. R. Angevaare,
V. C. Antochi,
D. Antón Martin,
F. Arneodo,
L. Baudis,
A. L. Baxter,
L. Bellagamba,
A. Bernard,
R. Biondi,
A. Bismark,
A. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
C. Capelli,
J. M. R. Cardoso,
D. Cichon,
B. Cimmino
, et al. (130 additional authors not shown)
Abstract:
Delayed single- and few-electron emissions plague dual-phase time projection chambers, limiting their potential to search for light-mass dark matter. This paper examines the origins of these events in the XENON1T experiment. Characterization of the intensity of delayed electron backgrounds shows that the resulting emissions are correlated, in time and position, with high-energy events and can effe…
▽ More
Delayed single- and few-electron emissions plague dual-phase time projection chambers, limiting their potential to search for light-mass dark matter. This paper examines the origins of these events in the XENON1T experiment. Characterization of the intensity of delayed electron backgrounds shows that the resulting emissions are correlated, in time and position, with high-energy events and can effectively be vetoed. In this work we extend previous S2-only analyses down to a single electron. From this analysis, after removing the correlated backgrounds, we observe rates < 30 events/(electron*kg*day) in the region of interest spanning 1 to 5 electrons. We derive 90% confidence upper limits for dark matter-electron scattering, first direct limits on the electric dipole, magnetic dipole, and anapole interactions, and bosonic dark matter models, where we exclude new parameter space for dark photons and solar dark photons.
△ Less
Submitted 28 June, 2022; v1 submitted 22 December, 2021;
originally announced December 2021.
-
Search for Coherent Elastic Scattering of Solar $^8$B Neutrinos in the XENON1T Dark Matter Experiment
Authors:
E. Aprile,
J. Aalbers,
F. Agostini,
S. Ahmed Maouloud,
M. Alfonsi,
L. Althueser,
F. D. Amaro,
S. Andaloro,
V. C. Antochi,
E. Angelino,
J. R. Angevaare,
F. Arneodo,
L. Baudis,
B. Bauermeister,
L. Bellagamba,
M. L. Benabderrahmane,
A. Brown,
E. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
C. Capelli,
J. M. R. Cardoso,
D. Cichon,
B. Cimmino
, et al. (113 additional authors not shown)
Abstract:
We report on a search for nuclear recoil signals from solar $^8$B neutrinos elastically scattering off xenon nuclei in XENON1T data, lowering the energy threshold from 2.6 keV to 1.6 keV. We develop a variety of novel techniques to limit the resulting increase in backgrounds near the threshold. No significant $^8$B neutrino-like excess is found in an exposure of 0.6 t $\times$ y. For the first tim…
▽ More
We report on a search for nuclear recoil signals from solar $^8$B neutrinos elastically scattering off xenon nuclei in XENON1T data, lowering the energy threshold from 2.6 keV to 1.6 keV. We develop a variety of novel techniques to limit the resulting increase in backgrounds near the threshold. No significant $^8$B neutrino-like excess is found in an exposure of 0.6 t $\times$ y. For the first time, we use the non-detection of solar neutrinos to constrain the light yield from 1-2 keV nuclear recoils in liquid xenon, as well as non-standard neutrino-quark interactions. Finally, we improve upon world-leading constraints on dark matter-nucleus interactions for dark matter masses between 3 GeV/c$^2$ and 11 GeV/c$^2$ by as much as an order of magnitude.
△ Less
Submitted 15 March, 2021; v1 submitted 4 December, 2020;
originally announced December 2020.
-
Search for inelastic scattering of WIMP dark matter in XENON1T
Authors:
XENON Collaboration,
E. Aprile,
J. Aalbers,
F. Agostini,
M. Alfonsi,
L. Althueser,
F. D. Amaro,
S. Andaloro,
E. Angelino,
J. R. Angevaare,
V. C. Antochi,
F. Arneodo,
L. Baudis,
B. Bauermeister,
L. Bellagamba,
M. L. Benabderrahmane,
A. Brown,
E. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
C. Capelli,
J. M. R. Cardoso,
D. Cichon,
B. Cimmino
, et al. (116 additional authors not shown)
Abstract:
We report the results of a search for the inelastic scattering of weakly interacting massive particles (WIMPs) in the XENON1T dark matter experiment. Scattering off $^{129}$Xe is the most sensitive probe of inelastic WIMP interactions, with a signature of a 39.6 keV de-excitation photon detected simultaneously with the nuclear recoil. Using an exposure of 0.89 tonne-years, we find no evidence of i…
▽ More
We report the results of a search for the inelastic scattering of weakly interacting massive particles (WIMPs) in the XENON1T dark matter experiment. Scattering off $^{129}$Xe is the most sensitive probe of inelastic WIMP interactions, with a signature of a 39.6 keV de-excitation photon detected simultaneously with the nuclear recoil. Using an exposure of 0.89 tonne-years, we find no evidence of inelastic WIMP scattering with a significance of more than 2$σ$. A profile-likelihood ratio analysis is used to set upper limits on the cross-section of WIMP-nucleus interactions. We exclude new parameter space for WIMPs heavier than 100 GeV/c${}^2$, with the strongest upper limit of $3.3 \times 10^{-39}$ cm${}^2$ for 130 GeV/c${}^2$ WIMPs at 90\% confidence level.
△ Less
Submitted 26 February, 2021; v1 submitted 20 November, 2020;
originally announced November 2020.
-
$^{222}$Rn emanation measurements for the XENON1T experiment
Authors:
E. Aprile,
J. Aalbers,
F. Agostini,
M. Alfonsi,
L. Althueser,
F. D. Amaro,
V. C. Antochi,
E. Angelino,
J. R. Angevaare,
F. Arneodo,
D. Barge,
L. Baudis,
B. Bauermeister,
L. Bellagamba,
M. L. Benabderrahmane,
T. Berger,
P. A. Breur,
A. Brown,
E. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
C. Capelli,
J. M. R. Cardoso,
D. Cichon
, et al. (118 additional authors not shown)
Abstract:
The selection of low-radioactive construction materials is of utmost importance for the success of low-energy rare event search experiments. Besides radioactive contaminants in the bulk, the emanation of radioactive radon atoms from material surfaces attains increasing relevance in the effort to further reduce the background of such experiments. In this work, we present the $^{222}$Rn emanation me…
▽ More
The selection of low-radioactive construction materials is of utmost importance for the success of low-energy rare event search experiments. Besides radioactive contaminants in the bulk, the emanation of radioactive radon atoms from material surfaces attains increasing relevance in the effort to further reduce the background of such experiments. In this work, we present the $^{222}$Rn emanation measurements performed for the XENON1T dark matter experiment. Together with the bulk impurity screening campaign, the results enabled us to select the radio-purest construction materials, targeting a $^{222}$Rn activity concentration of 10 $μ$Bq/kg in 3.2 t of xenon. The knowledge of the distribution of the $^{222}$Rn sources allowed us to selectively eliminate critical components in the course of the experiment. The predictions from the emanation measurements were compared to data of the $^{222}$Rn activity concentration in XENON1T. The final $^{222}$Rn activity concentration of (4.5 $\pm$ 0.1) $μ$Bq/kg in the target of XENON1T is the lowest ever achieved in a xenon dark matter experiment.
△ Less
Submitted 25 November, 2020; v1 submitted 29 September, 2020;
originally announced September 2020.
-
Projected WIMP Sensitivity of the XENONnT Dark Matter Experiment
Authors:
The XENON collaboration,
E. Aprile,
J. Aalbers,
F. Agostini,
M. Alfonsi,
L. Althueser,
F. D. Amaro,
V. C. Antochi,
E. Angelino,
J. R. Angevaare,
F. Arneodo,
D. Barge,
L. Baudis,
B. Bauermeister,
L. Bellagamba,
M. L. Benabderrahmane,
T. Berger,
A. Brown,
E. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
C. Capelli,
J. M. R. Cardoso,
D. Cichon
, et al. (115 additional authors not shown)
Abstract:
XENONnT is a dark matter direct detection experiment, utilizing 5.9 t of instrumented liquid xenon, located at the INFN Laboratori Nazionali del Gran Sasso. In this work, we predict the experimental background and project the sensitivity of XENONnT to the detection of weakly interacting massive particles (WIMPs). The expected average differential background rate in the energy region of interest, c…
▽ More
XENONnT is a dark matter direct detection experiment, utilizing 5.9 t of instrumented liquid xenon, located at the INFN Laboratori Nazionali del Gran Sasso. In this work, we predict the experimental background and project the sensitivity of XENONnT to the detection of weakly interacting massive particles (WIMPs). The expected average differential background rate in the energy region of interest, corresponding to (1, 13) keV and (4, 50) keV for electronic and nuclear recoils, amounts to $12.3 \pm 0.6$ (keV t y)$^{-1}$ and $(2.2\pm 0.5)\times 10^{-3}$ (keV t y)$^{-1}$, respectively, in a 4 t fiducial mass. We compute unified confidence intervals using the profile construction method, in order to ensure proper coverage. With the exposure goal of 20 t$\,$y, the expected sensitivity to spin-independent WIMP-nucleon interactions reaches a cross-section of $1.4\times10^{-48}$ cm$^2$ for a 50 GeV/c$^2$ mass WIMP at 90% confidence level, more than one order of magnitude beyond the current best limit, set by XENON1T. In addition, we show that for a 50 GeV/c$^2$ WIMP with cross-sections above $2.6\times10^{-48}$ cm$^2$ ($5.0\times10^{-48}$ cm$^2$) the median XENONnT discovery significance exceeds 3$σ$ (5$σ$). The expected sensitivity to the spin-dependent WIMP coupling to neutrons (protons) reaches $2.2\times10^{-43}$ cm$^2$ ($6.0\times10^{-42}$ cm$^2$).
△ Less
Submitted 17 November, 2020; v1 submitted 17 July, 2020;
originally announced July 2020.
-
Excess Electronic Recoil Events in XENON1T
Authors:
E. Aprile,
J. Aalbers,
F. Agostini,
M. Alfonsi,
L. Althueser,
F. D. Amaro,
V. C. Antochi,
E. Angelino,
J. R. Angevaare,
F. Arneodo,
D. Barge,
L. Baudis,
B. Bauermeister,
L. Bellagamba,
M. L. Benabderrahmane,
T. Berger,
A. Brown,
E. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
C. Capelli,
J. M. R. Cardoso,
D. Cichon,
B. Cimmino
, et al. (114 additional authors not shown)
Abstract:
We report results from searches for new physics with low-energy electronic recoil data recorded with the XENON1T detector. With an exposure of 0.65 t-y and an unprecedentedly low background rate of $76\pm2$ events/(t y keV) between 1 and 30 keV, the data enables sensitive searches for solar axions, an enhanced neutrino magnetic moment, and bosonic dark matter. An excess over known backgrounds is o…
▽ More
We report results from searches for new physics with low-energy electronic recoil data recorded with the XENON1T detector. With an exposure of 0.65 t-y and an unprecedentedly low background rate of $76\pm2$ events/(t y keV) between 1 and 30 keV, the data enables sensitive searches for solar axions, an enhanced neutrino magnetic moment, and bosonic dark matter. An excess over known backgrounds is observed at low energies and most prominent between 2 and 3 keV. The solar axion model has a 3.4$σ$ significance, and a 3D 90% confidence surface is reported for axion couplings to electrons, photons, and nucleons. This surface is inscribed in the cuboid defined by $g_{ae}<3.8 \times 10^{-12}$, $g_{ae}g_{an}^{eff}<4.8\times 10^{-18}$, and $g_{ae}g_{aγ}<7.7\times10^{-22} GeV^{-1}$, and excludes either $g_{ae}=0$ or $g_{ae}g_{aγ}=g_{ae}g_{an}^{eff}=0$. The neutrino magnetic moment signal is similarly favored over background at 3.2$σ$ and a confidence interval of $μ_ν \in (1.4,2.9)\times10^{-11}μ_B$ (90% C.L.) is reported. Both results are in strong tension with stellar constraints. The excess can also be explained by $β$ decays of tritium at 3.2$σ$ with a trace amount that can neither be confirmed nor excluded with current knowledge of its production and reduction mechanisms. The significances of the solar axion and neutrino magnetic moment hypotheses are reduced to 2.0$σ$ and 0.9$σ$, respectively, if an unconstrained tritium component is included in the fitting. With respect to bosonic dark matter, the excess favors a monoenergetic peak at ($2.3\pm0.2$) keV (68% C.L.) with a 3.0$σ$ global (4.0$σ$ local) significance. We also consider the possibility that $^{37}$Ar may be present in the detector and yield a 2.82 keV peak. Contrary to tritium, the $^{37}$Ar concentration can be tightly constrained and is found to be negligible.
△ Less
Submitted 16 October, 2020; v1 submitted 17 June, 2020;
originally announced June 2020.
-
Energy resolution and linearity of XENON1T in the MeV energy range
Authors:
E. Aprile,
J. Aalbers,
F. Agostini,
M. Alfonsi,
L. Althueser,
F. D. Amaro,
V. C. Antochi,
E. Angelino,
J. Angevaare,
F. Arneodo,
D. Barge,
L. Baudis,
B. Bauermeister,
L. Bellagamba,
M. L. Benabderrahmane,
T. Berger,
P. A. Breur,
A. Brown,
E. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
C. Capelli,
J. M. R. Cardoso,
D. Cichon
, et al. (113 additional authors not shown)
Abstract:
Xenon dual-phase time projection chambers designed to search for Weakly Interacting Massive Particles have so far shown a relative energy resolution which degrades with energy above $\sim$200 keV due to the saturation effects. This has limited their sensitivity in the search for rare events like the neutrinoless double-beta decay of $^{136}$Xe at its $Q$-value, $Q_{ββ}\simeq$ 2.46 MeV. For the XEN…
▽ More
Xenon dual-phase time projection chambers designed to search for Weakly Interacting Massive Particles have so far shown a relative energy resolution which degrades with energy above $\sim$200 keV due to the saturation effects. This has limited their sensitivity in the search for rare events like the neutrinoless double-beta decay of $^{136}$Xe at its $Q$-value, $Q_{ββ}\simeq$ 2.46 MeV. For the XENON1T dual-phase time projection chamber, we demonstrate that the relative energy resolution at 1 $σ/μ$ is as low as (0.80$\pm$0.02) % in its one-ton fiducial mass, and for single-site interactions at $Q_{ββ}$. We also present a new signal correction method to rectify the saturation effects of the signal readout system, resulting in more accurate position reconstruction and indirectly improving the energy resolution. The very good result achieved in XENON1T opens up new windows for the xenon dual-phase dark matter detectors to simultaneously search for other rare events.
△ Less
Submitted 9 September, 2020; v1 submitted 8 March, 2020;
originally announced March 2020.
-
Search for Light Dark Matter Interactions Enhanced by the Migdal effect or Bremsstrahlung in XENON1T
Authors:
E. Aprile,
J. Aalbers,
F. Agostini,
M. Alfonsi,
L. Althueser,
F. D. Amaro,
V. C. Antochi,
E. Angelino,
F. Arneodo,
D. Barge,
L. Baudis,
B. Bauermeister,
L. Bellagamba,
M. L. Benabderrahmane,
T. Berger,
P. A. Breur,
A. Brown,
E. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
C. Capelli,
J. M. R. Cardoso,
D. Cichon,
D. Coderre
, et al. (109 additional authors not shown)
Abstract:
Direct dark matter detection experiments based on a liquid xenon target are leading the search for dark matter particles with masses above $\sim$ 5 GeV/c$^2$, but have limited sensitivity to lighter masses because of the small momentum transfer in dark matter-nucleus elastic scattering. However, there is an irreducible contribution from inelastic processes accompanying the elastic scattering, whic…
▽ More
Direct dark matter detection experiments based on a liquid xenon target are leading the search for dark matter particles with masses above $\sim$ 5 GeV/c$^2$, but have limited sensitivity to lighter masses because of the small momentum transfer in dark matter-nucleus elastic scattering. However, there is an irreducible contribution from inelastic processes accompanying the elastic scattering, which leads to the excitation and ionization of the recoiling atom (the Migdal effect) or the emission of a Bremsstrahlung photon. In this letter, we report on a probe of low-mass dark matter with masses down to about 85 MeV/c$^2$ by looking for electronic recoils induced by the Migdal effect and Bremsstrahlung, using data from the XENON1T experiment. Besides the approach of detecting both scintillation and ionization signals, we exploit an approach that uses ionization signals only, which allows for a lower detection threshold. This analysis significantly enhances the sensitivity of XENON1T to light dark matter previously beyond its reach.
△ Less
Submitted 18 August, 2020; v1 submitted 30 July, 2019;
originally announced July 2019.
-
Light Dark Matter Search with Ionization Signals in XENON1T
Authors:
E. Aprile,
J. Aalbers,
F. Agostini,
M. Alfonsi,
L. Althueser,
F. D. Amaro,
V. C. Antochi,
E. Angelino,
F. Arneodo,
D. Barge,
L. Baudis,
B. Bauermeister,
L. Bellagamba,
M. L. Benabderrahmane,
T. Berger,
P. A. Breur,
A. Brown,
E. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
C. Capelli,
J. M. R. Cardoso,
D. Cichon,
D. Coderre
, et al. (108 additional authors not shown)
Abstract:
We report constraints on light dark matter (DM) models using ionization signals in the XENON1T experiment. We mitigate backgrounds with strong event selections, rather than requiring a scintillation signal, leaving an effective exposure of $(22 \pm 3)$ tonne-days. Above $\sim\!0.4\,\mathrm{keV}_\mathrm{ee}$, we observe…
▽ More
We report constraints on light dark matter (DM) models using ionization signals in the XENON1T experiment. We mitigate backgrounds with strong event selections, rather than requiring a scintillation signal, leaving an effective exposure of $(22 \pm 3)$ tonne-days. Above $\sim\!0.4\,\mathrm{keV}_\mathrm{ee}$, we observe $<1 \, \text{event}/(\text{tonne} \times \text{day} \times \text{keV}_\text{ee})$, which is more than one thousand times lower than in similar searches with other detectors. Despite observing a higher rate at lower energies, no DM or CEvNS detection may be claimed because we cannot model all of our backgrounds. We thus exclude new regions in the parameter spaces for DM-nucleus scattering for DM masses $m_χ$ within $3-6\,\mathrm{GeV}/\mathrm{c}^2$, DM-electron scattering for $m_χ> 30\,\mathrm{MeV}/\mathrm{c}^2$, and absorption of dark photons and axion-like particles for $m_χ$ within $0.186 - 1 \, \mathrm{keV}/\mathrm{c}^2$.
△ Less
Submitted 17 December, 2019; v1 submitted 26 July, 2019;
originally announced July 2019.
-
XENON1T Dark Matter Data Analysis: Signal Reconstruction, Calibration and Event Selection
Authors:
E. Aprile,
J. Aalbers,
F. Agostini,
M. Alfonsi,
L. Althueser,
F. D. Amaro,
V. C. Antochi,
F. Arneodo,
L. Baudis,
B. Bauermeister,
L. Bellagamba,
M. L. Benabderrahmane,
T. Berger,
P. A. Breur,
A. Brown,
E. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
C. Capelli,
J. M. R. Cardoso,
D. Cichon,
D. Coderre,
A. P. Colijn,
J. Conrad
, et al. (103 additional authors not shown)
Abstract:
The XENON1T experiment at the Laboratori Nazionali del Gran Sasso is the most sensitive direct detection experiment for dark matter in the form of weakly interacting particles (WIMPs) with masses above $6\,$GeV/$c^2$ scattering off nuclei. The detector employs a dual-phase time projection chamber with 2.0 metric tons of liquid xenon in the target. A one metric $\mathrm{ton}\times\mathrm{year}$ exp…
▽ More
The XENON1T experiment at the Laboratori Nazionali del Gran Sasso is the most sensitive direct detection experiment for dark matter in the form of weakly interacting particles (WIMPs) with masses above $6\,$GeV/$c^2$ scattering off nuclei. The detector employs a dual-phase time projection chamber with 2.0 metric tons of liquid xenon in the target. A one metric $\mathrm{ton}\times\mathrm{year}$ exposure of science data was collected between October 2016 and February 2018. This article reports on the performance of the detector during this period and describes details of the data analysis that led to the most stringent exclusion limits on various WIMP-nucleon interaction models to date. In particular, signal reconstruction, event selection and calibration of the detector response to nuclear and electronic recoils in XENON1T are discussed.
△ Less
Submitted 4 November, 2019; v1 submitted 11 June, 2019;
originally announced June 2019.
-
XENON1T Dark Matter Data Analysis: Signal & Background Models, and Statistical Inference
Authors:
E. Aprile,
J. Aalbers,
F. Agostini,
M. Alfonsi,
L. Althueser,
F. D. Amaro,
V. C. Antochi,
F. Arneodo,
L. Baudis,
B. Bauermeister,
M. L. Benabderrahmane,
T. Berger,
P. A. Breur,
A. Brown,
E. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
C. Capelli,
J. M. R. Cardoso,
D. Cichon,
D. Coderre,
A. P. Colijn,
J. Conrad,
J. P. Cussonneau
, et al. (101 additional authors not shown)
Abstract:
The XENON1T experiment searches for dark matter particles through their scattering off xenon atoms in a 2 tonne liquid xenon target. The detector is a dual-phase time projection chamber, which measures simultaneously the scintillation and ionization signals produced by interactions in target volume, to reconstruct energy and position, as well as the type of the interaction. The background rate in…
▽ More
The XENON1T experiment searches for dark matter particles through their scattering off xenon atoms in a 2 tonne liquid xenon target. The detector is a dual-phase time projection chamber, which measures simultaneously the scintillation and ionization signals produced by interactions in target volume, to reconstruct energy and position, as well as the type of the interaction. The background rate in the central volume of XENON1T detector is the lowest achieved so far with a liquid xenon-based direct detection experiment. In this work we describe the response model of the detector, the background and signal models, and the statistical inference procedures used in the dark matter searches with a 1 tonne$\times$year exposure of XENON1T data, that leaded to the best limit to date on WIMP-nucleon spin-independent elastic scatter cross-section for WIMP masses above 6 GeV/c$^2$.
△ Less
Submitted 28 February, 2019; v1 submitted 28 February, 2019;
originally announced February 2019.
-
First results on the scalar WIMP-pion coupling, using the XENON1T experiment
Authors:
E. Aprile,
J. Aalbers,
F. Agostini,
M. Alfonsi,
L. Althueser,
F. D. Amaro,
M. Anthony,
V. C. Antochi,
F. Arneodo,
L. Baudis,
B. Bauermeister,
M. L. Benabderrahmane,
T. Berger,
P. A. Breur,
A. Brown,
A. Brown,
E. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
C. Capelli,
J. M. R. Cardoso,
D. Cichon,
D. Coderre,
A. P. Colijn
, et al. (107 additional authors not shown)
Abstract:
We present first results on the scalar WIMP-pion coupling from 1 t$\times$yr of exposure with the XENON1T experiment. This interaction is generated when the WIMP couples to a virtual pion exchanged between the nucleons in a nucleus. In contrast to most non-relativistic operators, these pion-exchange currents can be coherently enhanced by the total number of nucleons, and therefore may dominate in…
▽ More
We present first results on the scalar WIMP-pion coupling from 1 t$\times$yr of exposure with the XENON1T experiment. This interaction is generated when the WIMP couples to a virtual pion exchanged between the nucleons in a nucleus. In contrast to most non-relativistic operators, these pion-exchange currents can be coherently enhanced by the total number of nucleons, and therefore may dominate in scenarios where spin-independent WIMP-nucleon interactions are suppressed. Moreover, for natural values of the couplings, they dominate over the spin-dependent channel due to their coherence in the nucleus. Using the signal model of this new WIMP-pion channel, no significant excess is found, leading to an upper limit cross section of $6.4\times10^{-46}$ cm$^2$ (90 % confidence level) at 30 GeV/c$^2$ WIMP mass.
△ Less
Submitted 22 February, 2019; v1 submitted 29 November, 2018;
originally announced November 2018.
-
Dark Matter Search Results from a One Tonne$\times$Year Exposure of XENON1T
Authors:
E. Aprile,
J. Aalbers,
F. Agostini,
M. Alfonsi,
L. Althueser,
F. D. Amaro,
M. Anthony,
F. Arneodo,
L. Baudis,
B. Bauermeister,
M. L. Benabderrahmane,
T. Berger,
P. A. Breur,
A. Brown,
A. Brown,
E. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
C. Capelli,
J. M. R. Cardoso,
D. Cichon,
D. Coderre,
A. P. Colijn,
J. Conrad
, et al. (95 additional authors not shown)
Abstract:
We report on a search for Weakly Interacting Massive Particles (WIMPs) using 278.8 days of data collected with the XENON1T experiment at LNGS. XENON1T utilizes a liquid xenon time projection chamber with a fiducial mass of $(1.30 \pm 0.01)$ t, resulting in a 1.0 t$\times$yr exposure. The energy region of interest, [1.4, 10.6] $\mathrm{keV_{ee}}$ ([4.9, 40.9] $\mathrm{keV_{nr}}$), exhibits an ultra…
▽ More
We report on a search for Weakly Interacting Massive Particles (WIMPs) using 278.8 days of data collected with the XENON1T experiment at LNGS. XENON1T utilizes a liquid xenon time projection chamber with a fiducial mass of $(1.30 \pm 0.01)$ t, resulting in a 1.0 t$\times$yr exposure. The energy region of interest, [1.4, 10.6] $\mathrm{keV_{ee}}$ ([4.9, 40.9] $\mathrm{keV_{nr}}$), exhibits an ultra-low electron recoil background rate of $(82\substack{+5 \\ -3}\textrm{ (sys)}\pm3\textrm{ (stat)})$ events/$(\mathrm{t}\times\mathrm{yr}\times\mathrm{keV_{ee}})$. No significant excess over background is found and a profile likelihood analysis parameterized in spatial and energy dimensions excludes new parameter space for the WIMP-nucleon spin-independent elastic scatter cross-section for WIMP masses above 6 GeV/c${}^2$, with a minimum of $4.1\times10^{-47}$ cm$^2$ at 30 GeV/c${}^2$ and 90% confidence level.
△ Less
Submitted 13 September, 2018; v1 submitted 31 May, 2018;
originally announced May 2018.