-
Search for Dark Photon Dark Matter in the Mass Range 41--74 $μ\mathrm{eV}$ using Millimeter-Wave Receiver and Radioshielding Box
Authors:
S. Adachi,
F. Fu**aka,
S. Honda,
Y. Muto,
H. Nakata,
Y. Sueno,
T. Sumida,
J. Suzuki,
O. Tajima,
H. Takeuchi
Abstract:
Dark photons have been considered potential candidates for dark matter. The dark photon dark matter (DPDM) has a mass and interacts with electromagnetic fields via kinetic mixing with a coupling constant of $χ$. Thus, DPDMs are converted into ordinary photons at metal surfaces. Using a millimeter-wave receiver set in a radioshielding box, we performed experiments to detect the conversion photons f…
▽ More
Dark photons have been considered potential candidates for dark matter. The dark photon dark matter (DPDM) has a mass and interacts with electromagnetic fields via kinetic mixing with a coupling constant of $χ$. Thus, DPDMs are converted into ordinary photons at metal surfaces. Using a millimeter-wave receiver set in a radioshielding box, we performed experiments to detect the conversion photons from the DPDM in the frequency range 10--18 GHz, which corresponds to a mass range 41--74 $μ\mathrm{eV}$. We found no conversion photon signal in this range and set the upper limits to $χ< (0.5\text{--}3.9) \times 10^{-10}$ at a 95% confidence level.
△ Less
Submitted 16 November, 2023; v1 submitted 28 August, 2023;
originally announced August 2023.
-
Search for Dark Photon Dark Matter in the Mass Range $74\mbox{--}110\,μ\mathrm{eV}/c^2$ with a Cryogenic Millimeter-Wave Receiver
Authors:
Shumpei Kotaka,
Shunsuke Adachi,
Ryo Fu**aka,
Shunsuke Honda,
Hironobu Nakata,
Yudai Seino,
Yoshinori Sueno,
Toshi Sumida,
Junya Suzuki,
Osamu Tajima,
Soichiro Takeichi
Abstract:
We search for the dark photon dark matter (DPDM) using a cryogenic millimeter-wave receiver. DPDM has a kinetic coupling with electromagnetic fields with a coupling constant of $χ$, and is converted into ordinary photons at the surface of a metal plate. We search for signal of this conversion in the frequency range $18\text{--}26.5\,\mathrm{GHz}$, which corresponds to the mass range…
▽ More
We search for the dark photon dark matter (DPDM) using a cryogenic millimeter-wave receiver. DPDM has a kinetic coupling with electromagnetic fields with a coupling constant of $χ$, and is converted into ordinary photons at the surface of a metal plate. We search for signal of this conversion in the frequency range $18\text{--}26.5\,\mathrm{GHz}$, which corresponds to the mass range $74\text{--}110\,mu\mathrm{eV}/c^2$. We observed no significant signal excess, allowing us to set an upper bound of $χ< (0.3\text{--}2.0)\times 10^{-10}$ at 95\% confidence level. This is the most stringent constraint to date, and tighter than cosmological constraints. Improvements from previous studies are obtained by employing a cryogenic optical path and a fast spectrometer.
△ Less
Submitted 19 February, 2023; v1 submitted 7 May, 2022;
originally announced May 2022.
-
A forecast of the sensitivity on the measurement of the optical depth to reionization with the GroundBIRD experiment
Authors:
Kyungmin Lee,
Ricardo T. Génova-Santos,
Masashi Hazumi,
Shunsuke Honda,
Hiroki Kutsuma,
Shugo Oguri,
Chiko Otani,
Mike W. Peel,
Yoshinori Sueno,
Junya Suzuki,
Osamu Tajima,
Eunil Won
Abstract:
We compute the expected sensitivity on measurements of optical depth to reionization for a ground-based experiment at Teide Observatory. We simulate polarized partial sky maps for the GroundBIRD experiment at the frequencies 145 and 220 GHz. We perform fits for the simulated maps with our pixel-based likelihood to extract the optical depth to reionization. The noise levels of polarization maps are…
▽ More
We compute the expected sensitivity on measurements of optical depth to reionization for a ground-based experiment at Teide Observatory. We simulate polarized partial sky maps for the GroundBIRD experiment at the frequencies 145 and 220 GHz. We perform fits for the simulated maps with our pixel-based likelihood to extract the optical depth to reionization. The noise levels of polarization maps are estimated as 110 $μ\mathrm{K~arcmin}$ and 780 $ μ\mathrm{K~arcmin}$ for 145 and 220 GHz, respectively, by assuming a three-year observing campaign and sky coverages of 0.537 for 145 GHz and 0.462 for 220 GHz. Our sensitivities for the optical depth to reionization are found to be $σ_τ$=0.030 with the simulated GroundBIRD maps, and $σ_τ$=0.012 by combining with the simulated QUIJOTE maps at 11, 13, 17, 19, 30, and 40 GHz.
△ Less
Submitted 9 May, 2021; v1 submitted 5 February, 2021;
originally announced February 2021.