-
Interpretable machine learning approach for electron antineutrino selection in a large liquid scintillator detector
Authors:
A. Gavrikov,
V. Cerrone,
A. Serafini,
R. Brugnera,
A. Garfagnini,
M. Grassi,
B. Jelmini,
L. Lastrucci,
S. Aiello,
G. Andronico,
V. Antonelli,
A. Barresi,
D. Basilico,
M. Beretta,
A. Bergnoli,
M. Borghesi,
A. Brigatti,
R. Bruno,
A. Budano,
B. Caccianiga,
A. Cammi,
R. Caruso,
D. Chiesa,
C. Clementi,
S. Dusini
, et al. (43 additional authors not shown)
Abstract:
Several neutrino detectors, KamLAND, Daya Bay, Double Chooz, RENO, and the forthcoming large-scale JUNO, rely on liquid scintillator to detect reactor antineutrino interactions. In this context, inverse beta decay represents the golden channel for antineutrino detection, providing a pair of correlated events, thus a strong experimental signature to distinguish the signal from a variety of backgrou…
▽ More
Several neutrino detectors, KamLAND, Daya Bay, Double Chooz, RENO, and the forthcoming large-scale JUNO, rely on liquid scintillator to detect reactor antineutrino interactions. In this context, inverse beta decay represents the golden channel for antineutrino detection, providing a pair of correlated events, thus a strong experimental signature to distinguish the signal from a variety of backgrounds. However, given the low cross-section of antineutrino interactions, the development of a powerful event selection algorithm becomes imperative to achieve effective discrimination between signal and backgrounds. In this study, we introduce a machine learning (ML) model to achieve this goal: a fully connected neural network as a powerful signal-background discriminator for a large liquid scintillator detector. We demonstrate, using the JUNO detector as an example, that, despite the already high efficiency of a cut-based approach, the presented ML model can further improve the overall event selection efficiency. Moreover, it allows for the retention of signal events at the detector edges that would otherwise be rejected because of the overwhelming amount of background events in that region. We also present the first interpretable analysis of the ML approach for event selection in reactor neutrino experiments. This method provides insights into the decision-making process of the model and offers valuable information for improving and updating traditional event selection approaches.
△ Less
Submitted 9 June, 2024;
originally announced June 2024.
-
Distillation and Strip** purification plants for JUNO liquid scintillator
Authors:
C. Landini,
M. Beretta,
P. Lombardi,
A. Brigatti,
M. Montuschi,
S. Parmeggiano,
G. Ranucci,
V. Antonelli,
D. Basilico,
B. Caccianiga,
M. G. Giammarchi,
L. Miramonti,
E. Percalli,
A. C. Re,
P. Saggese,
M. D. C. Torri,
S. Aiello,
G. Andronico,
A. Barresi,
A. Bergnoli,
M. Borghesi,
R. Brugnera,
R. Bruno,
A. Budano,
A. Cammi
, et al. (42 additional authors not shown)
Abstract:
The optical and radiochemical purification of the scintillating liquid, which will fill the central detector of the JUNO experiment, plays a crucial role in achieving its scientific goals. Given its gigantic mass and dimensions and an unprecedented target value of about 3% @ 1 MeV in energy resolution, JUNO has set severe requirements on the parameters of its scintillator, such as attenuation leng…
▽ More
The optical and radiochemical purification of the scintillating liquid, which will fill the central detector of the JUNO experiment, plays a crucial role in achieving its scientific goals. Given its gigantic mass and dimensions and an unprecedented target value of about 3% @ 1 MeV in energy resolution, JUNO has set severe requirements on the parameters of its scintillator, such as attenuation length (Lat>20 m at 430 nm), transparency, light yield, and content of radioactive contaminants (238U,232Th<10-15 g/g). To accomplish these needs, the scintillator will be processed using several purification methods, including distillation in partial vacuum and gas strip**, which are performed in two large scale plants installed at the JUNO site. In this paper, layout, operating principles, and technical aspects which have driven the design and construction of the distil- lation and gas strip** plants are reviewed. The distillation is effective in enhancing the optical properties and removing heavy radio-impurities (238U,232Th, 40K), while the strip** process exploits pure water steam and high-purity nitrogen to extract gaseous contaminants (222Rn, 39Ar, 85Kr, O2) from the scintillator. The plant operating parameters have been tuned during the recent com- missioning phase at the JUNO site and several QA/QC measurements and tests have been performed to evaluate the performances of the plants. Some preliminary results on the efficiency of these purification processes will be shown.
△ Less
Submitted 3 June, 2024;
originally announced June 2024.
-
Refractive index in the JUNO liquid scintillator
Authors:
H. S. Zhang,
M. Beretta,
S. Cialdi,
C. X. Yang,
J. H. Huang,
F. Ferraro,
G. F. Cao,
G. Reina,
Z. Y. Deng,
E. Suerra,
S. Altilia,
V. Antonelli,
D. Basilico,
A. Brigatti,
B. Caccianiga,
M. G. Giammarchi,
C. Landini,
P. Lombardi,
L. Miramonti,
E. Percalli,
G. Ranucci,
A. C. Re,
P. Saggese,
M. D. C. Torri,
S. Aiello
, et al. (51 additional authors not shown)
Abstract:
In the field of rare event physics, it is common to have huge masses of organic liquid scintillator as detection medium. In particular, they are widely used to study neutrino properties or astrophysical neutrinos. Thanks to its safety properties (such as low toxicity and high flash point) and easy scalability, linear alkyl benzene is the most common solvent used to produce liquid scintillators for…
▽ More
In the field of rare event physics, it is common to have huge masses of organic liquid scintillator as detection medium. In particular, they are widely used to study neutrino properties or astrophysical neutrinos. Thanks to its safety properties (such as low toxicity and high flash point) and easy scalability, linear alkyl benzene is the most common solvent used to produce liquid scintillators for large mass experiments. The knowledge of the refractive index is a pivotal point to understand the detector response, as this quantity (and its wavelength dependence) affects the Cherenkov radiation and photon propagation in the medium. In this paper, we report the measurement of the refractive index of the JUNO liquid scintillator between 260-1064 nm performed with two different methods (an ellipsometer and a refractometer), with a sub percent level precision. In addition, we used an interferometer to measure the group velocity in the JUNO liquid scintillator and verify the expected value derived from the refractive index measurements.
△ Less
Submitted 30 May, 2024;
originally announced May 2024.
-
Validation and integration tests of the JUNO 20-inch PMTs readout electronics
Authors:
Vanessa Cerrone,
Katharina von Sturm,
Marco Bellato,
Antonio Bergnoli,
Matteo Bolognesi,
Riccardo Brugnera,
Chao Chen,
Barbara Clerbaux,
Alberto Coppi,
Flavio dal Corso,
Daniele Corti,
Jianmeng Dong,
Wei Dou,
Lei Fan,
Alberto Garfagnini,
Guanghua Gong,
Marco Grassi,
Shuang Hang,
Rosa Maria Guizzetti,
Cong He,
Jun Hu,
Roberto Isocrate,
Beatrice Jelmini,
Xiaolu Ji,
Xiaoshan Jiang
, et al. (105 additional authors not shown)
Abstract:
The Jiangmen Underground Neutrino Observatory (JUNO) is a large neutrino detector currently under construction in China. JUNO will be able to study the neutrino mass ordering and to perform leading measurements detecting terrestrial and astrophysical neutrinos in a wide energy range, spanning from 200 keV to several GeV. Given the ambitious physics goals of JUNO, the electronic system has to meet…
▽ More
The Jiangmen Underground Neutrino Observatory (JUNO) is a large neutrino detector currently under construction in China. JUNO will be able to study the neutrino mass ordering and to perform leading measurements detecting terrestrial and astrophysical neutrinos in a wide energy range, spanning from 200 keV to several GeV. Given the ambitious physics goals of JUNO, the electronic system has to meet specific tight requirements, and a thorough characterization is required. The present paper describes the tests performed on the readout modules to measure their performances.
△ Less
Submitted 16 December, 2022;
originally announced December 2022.
-
Embedded Readout Electronics R&D for the Large PMTs in the JUNO Experiment
Authors:
M. Bellato,
A. Bergnoli,
A. Brugnera,
S. Chen,
Z. Chen,
B. Clerbaux,
F. dal Corso,
D. Corti,
J. Dong,
G. Galet,
A. Garfagnini,
A. Giaz,
G. Gong,
C. Grewing,
J. Hu,
R. Isocrate,
X. Jiang,
F. Li,
I. Lippi,
F. Marini,
Z. Ning,
A. G. Olshevskiyi,
D. Pedretti,
P. A. Petitjean,
M. Robens
, et al. (69 additional authors not shown)
Abstract:
Jiangmen Underground neutrino Observatory (JUNO) is a next generation liquid scintillator neutrino experiment under construction phase in South China. Thanks to the anti-neutrinos produced by the nearby nuclear power plants, JUNO will primarily study the neutrino mass hierarchy, one of the open key questions in neutrino physics. One key ingredient for the success of the measurement is to use high…
▽ More
Jiangmen Underground neutrino Observatory (JUNO) is a next generation liquid scintillator neutrino experiment under construction phase in South China. Thanks to the anti-neutrinos produced by the nearby nuclear power plants, JUNO will primarily study the neutrino mass hierarchy, one of the open key questions in neutrino physics. One key ingredient for the success of the measurement is to use high speed, high resolution sampling electronics located very close to the detector signal. Linearity in the response of the electronics in another important ingredient for the success of the experiment. During the initial design phase of the electronics, a custom design, with the Front-End and Read-Out electronics located very close to the detector analog signal has been developed and successfully tested. The present paper describes the electronics structure and the first tests performed on the prototypes. The electronics prototypes have been tested and they show good linearity response, with a maximum deviation of 1.3% over the full dynamic range (1-1000 p.e.), fulfilling the JUNO experiment requirements.
△ Less
Submitted 17 May, 2020; v1 submitted 18 March, 2020;
originally announced March 2020.