-
Axion-Like Particle Detection in Alkali-Noble-Gas Haloscopes
Authors:
Xiaofei Huang,
Xiaolin Ma,
Lei Cong,
Wei Ji,
Jia Liu,
Wei Quan,
Kai Wei
Abstract:
Revealing the essence of dark matter (DM) and dark energy is essential for understanding our universe. Ultralight (rest energy $<$10 eV) bosonic particles, including pseudoscalar axions and axion-like particles (ALPs) have emerged among leading candidates to explain the composition of DM and searching for them has become an important part of precision-measurement science. Ultrahigh-sensitivity alk…
▽ More
Revealing the essence of dark matter (DM) and dark energy is essential for understanding our universe. Ultralight (rest energy $<$10 eV) bosonic particles, including pseudoscalar axions and axion-like particles (ALPs) have emerged among leading candidates to explain the composition of DM and searching for them has become an important part of precision-measurement science. Ultrahigh-sensitivity alkali-noble-gas based comagnetometers and magnetometers are being used as powerful haloscopes, i.e., devices designed to search for DM present in the galactic halo. A broad variety of such devices include clock-comparison comagnetometers, self-compensating comagnetometers, hybrid-spin-resonance magnetometer, spin-exchange-relaxation-free magnetometers, nuclear magnetic-resonance magnetometers, Floquet magnetometers, masers, as well as devices like the cosmic axion spin-precession experiment (CASPEr) using liquid $^{129}$Xe, prepolarized via spin-exchange optical pum** with rubidium atoms. The combination of alkali metal and noble gas allows one to take the best advantage of the complementary properties of the two spin systems. This review summarizes the operational principles, experimental setups and the successful explorations of new physics using these haloscopes. Additionally, some limiting factors are pointed out for further improvement.
△ Less
Submitted 9 July, 2024; v1 submitted 14 December, 2023;
originally announced December 2023.
-
Dark matter search with a strongly-coupled hybrid spin system
Authors:
Kai Wei,
Zitong Xu,
Yuxuan He,
Xiaolin Ma,
Xing Heng,
Xiaofei Huang,
Wei Quan,
Wei Ji,
Jia Liu,
** Wang,
Jiancheng Fang,
Dmitry Budker
Abstract:
Observational evidence suggests the existence of dark matter (DM), which comprises approximately $84.4\%$ of matter in the universe. Recent advances in tabletop quantum sensor technology have enabled searches for nongravitational interactions of DM. Our experiment named ChangE utilizes Coupled Hot Atom eNsembles to search for liGht dark mattEr and new physics. We identify a strongly-coupled hybrid…
▽ More
Observational evidence suggests the existence of dark matter (DM), which comprises approximately $84.4\%$ of matter in the universe. Recent advances in tabletop quantum sensor technology have enabled searches for nongravitational interactions of DM. Our experiment named ChangE utilizes Coupled Hot Atom eNsembles to search for liGht dark mattEr and new physics. We identify a strongly-coupled hybrid spin-resonance (HSR) regime that enhances the bandwidth of $^{21}$Ne nuclear spin by three orders of magnitude while maintaining high sensitivity. In combination with a self-compensating mode (SC) for low frequencies, we present a comprehensive broadband search for axion-like dark matter with Compton frequencies in the range of $[0.01, 1000]$ Hz. We set new constraints on the DM interactions with neutrons and protons, accounting for the stochastic effect. For the axion-neutron coupling, our results reach a low value of $|g_{ann}|\le 3\times 10^{-10}$ in the frequency range $[0.02 , 4]$ Hz surpassing astrophysical limits and provide the strongest laboratory constraints in the $[10, 100]$ Hz range. For the axion-proton coupling, we offer the best terrestrial constraints for the frequency below 100 Hz.
△ Less
Submitted 13 June, 2023;
originally announced June 2023.
-
Searching for axion-like time-dependent cosmic birefringence with data from SPT-3G
Authors:
K. R. Ferguson,
A. J. Anderson,
N. Whitehorn,
P. A. R. Ade,
M. Archipley,
J. S. Avva,
L. Balkenhol,
K. Benabed,
A. N. Bender,
B. A. Benson,
F. Bianchini,
L. E. Bleem,
F. R. Bouchet,
L. Bryant,
E. Camphuis,
J. E. Carlstrom,
T. W. Cecil,
C. L. Chang,
P. Chaubal,
P. M. Chichura,
T. -L. Chou,
T. M. Crawford,
A. Cukierman,
C. Daley,
T. de Haan
, et al. (56 additional authors not shown)
Abstract:
Ultralight axionlike particles (ALPs) are compelling dark matter candidates because of their potential to resolve small-scale discrepancies between $Λ$CDM predictions and cosmological observations. Axion-photon coupling induces a polarization rotation in linearly polarized photons traveling through an ALP field; thus, as the local ALP dark matter field oscillates in time, distant static polarized…
▽ More
Ultralight axionlike particles (ALPs) are compelling dark matter candidates because of their potential to resolve small-scale discrepancies between $Λ$CDM predictions and cosmological observations. Axion-photon coupling induces a polarization rotation in linearly polarized photons traveling through an ALP field; thus, as the local ALP dark matter field oscillates in time, distant static polarized sources will appear to oscillate with a frequency proportional to the ALP mass. We use observations of the cosmic microwave background from SPT-3G, the current receiver on the South Pole Telescope, to set upper limits on the value of the axion-photon coupling constant $g_{φγ}$ over the approximate mass range $10^{-22} - 10^{-19}$ eV, corresponding to oscillation periods from 12 hours to 100 days. For periods between 1 and 100 days ($4.7 \times 10^{-22} \text{ eV} \leq m_φ\leq 4.7 \times 10^{-20} \text{ eV}$), where the limit is approximately constant, we set a median 95% C.L. upper limit on the amplitude of on-sky polarization rotation of 0.071 deg. Assuming that dark matter comprises a single ALP species with a local dark matter density of $0.3\text{ GeV/cm}^3$, this corresponds to $g_{φγ} < 1.18 \times 10^{-12}\text{ GeV}^{-1} \times \left( \frac{m_φ}{1.0 \times 10^{-21} \text{ eV}} \right)$. These new limits represent an improvement over the previous strongest limits set using the same effect by a factor of ~3.8.
△ Less
Submitted 29 August, 2022; v1 submitted 30 March, 2022;
originally announced March 2022.
-
Year two instrument status of the SPT-3G cosmic microwave background receiver
Authors:
A. N. Bender,
P. A. R. Ade,
Z. Ahmed,
A. J. Anderson,
J. S. Avva,
K. Aylor,
P. S. Barry,
R. Basu Thakur,
B. A. Benson,
L. S. Bleem,
S. Bocquet,
K. Byrum,
J. E. Carlstrom,
F. W. Carter,
T. W. Cecil,
C. L. Chang,
H. -M. Cho,
J. F. Cliche,
T. M. Crawford,
A. Cukierman,
T. de Haan,
E. V. Denison,
J. Ding,
M. A. Dobbs,
S. Dodelson
, et al. (64 additional authors not shown)
Abstract:
The South Pole Telescope (SPT) is a millimeter-wavelength telescope designed for high-precision measurements of the cosmic microwave background (CMB). The SPT measures both the temperature and polarization of the CMB with a large aperture, resulting in high resolution maps sensitive to signals across a wide range of angular scales on the sky. With these data, the SPT has the potential to make a br…
▽ More
The South Pole Telescope (SPT) is a millimeter-wavelength telescope designed for high-precision measurements of the cosmic microwave background (CMB). The SPT measures both the temperature and polarization of the CMB with a large aperture, resulting in high resolution maps sensitive to signals across a wide range of angular scales on the sky. With these data, the SPT has the potential to make a broad range of cosmological measurements. These include constraining the effect of massive neutrinos on large-scale structure formation as well as cleaning galactic and cosmological foregrounds from CMB polarization data in future searches for inflationary gravitational waves. The SPT began observing in January 2017 with a new receiver (SPT-3G) containing $\sim$16,000 polarization-sensitive transition-edge sensor bolometers. Several key technology developments have enabled this large-format focal plane, including advances in detectors, readout electronics, and large millimeter-wavelength optics. We discuss the implementation of these technologies in the SPT-3G receiver as well as the challenges they presented. In late 2017 the implementations of all three of these technologies were modified to optimize total performance. Here, we present the current instrument status of the SPT-3G receiver.
△ Less
Submitted 31 August, 2018;
originally announced September 2018.