-
Constraints on the Blazar-Boosted Dark Matter from the CDEX-10 Experiment
Authors:
R. Xu,
L. T. Yang,
Q. Yue,
K. J. Kang,
Y. J. Li,
H. P. An,
Greeshma C.,
J. P. Chang,
Y. H. Chen,
J. P. Cheng,
W. H. Dai,
Z. Deng,
C. H. Fang,
X. P. Geng,
H. Gong,
Q. J. Guo,
T. Guo,
X. Y. Guo,
L. He,
S. M. He,
J. W. Hu,
H. X. Huang,
T. C. Huang,
L. Jiang,
S. Karmakar
, et al. (59 additional authors not shown)
Abstract:
We report new constraints on light dark matter (DM) boosted by blazars using the 205.4 kg day data from the CDEX-10 experiment located at the China **** Underground Laboratory. Two representative blazars, TXS 0506+56 and BL Lacertae are studied. The results derived from TXS 0506+56 exclude DM-nucleon elastic scattering cross sections from $4.6\times 10^{-33}\ \rm cm^2$ to…
▽ More
We report new constraints on light dark matter (DM) boosted by blazars using the 205.4 kg day data from the CDEX-10 experiment located at the China **** Underground Laboratory. Two representative blazars, TXS 0506+56 and BL Lacertae are studied. The results derived from TXS 0506+56 exclude DM-nucleon elastic scattering cross sections from $4.6\times 10^{-33}\ \rm cm^2$ to $1\times10^{-26}\ \rm cm^2$ for DM masses between 10 keV and 1 GeV, and the results derived from BL Lacertae exclude DM-nucleon elastic scattering cross sections from $2.4\times 10^{-34}\ \rm cm^2$ to $1\times10^{-26}\ \rm cm^2$ for the same range of DM masses. The constraints correspond to the best sensitivities among solid-state detector experiments in the sub-MeV mass range.
△ Less
Submitted 29 March, 2024;
originally announced March 2024.
-
Probing Dark Matter Particles from Evaporating Primordial Black Holes via Electron Scattering in the CDEX-10 Experiment
Authors:
Z. H. Zhang,
L. T. Yang,
Q. Yue,
K. J. Kang,
Y. J. Li,
H. P. An,
Greeshma C.,
J. P. Chang,
Y. H. Chen,
J. P. Cheng,
W. H. Dai,
Z. Deng,
C. H. Fang,
X. P. Geng,
H. Gong,
Q. J. Guo,
T. Guo,
X. Y. Guo,
L. He,
S. M. He,
J. W. Hu,
H. X. Huang,
T. C. Huang,
L. Jiang,
S. Karmakar
, et al. (59 additional authors not shown)
Abstract:
Dark matter (DM) is a major constituent of the Universe. However, no definite evidence of DM particles (denoted as ``$χ$") has been found in DM direct detection (DD) experiments to date. There is a novel concept that detecting $χ$ from evaporating primordial black holes (PBHs). We search for $χ$ emitted from PBHs by investigating their interaction with target electrons. The examined PBH masses ran…
▽ More
Dark matter (DM) is a major constituent of the Universe. However, no definite evidence of DM particles (denoted as ``$χ$") has been found in DM direct detection (DD) experiments to date. There is a novel concept that detecting $χ$ from evaporating primordial black holes (PBHs). We search for $χ$ emitted from PBHs by investigating their interaction with target electrons. The examined PBH masses range from 1$\times$10$^{15}$ to 7$\times$10$^{16}$ g under the current limits of PBH abundance $f_{PBH}$. Using 205.4 kg$\cdot$day data obtained from the CDEX-10 experiment conducted in the China **** Underground Laboratory, we exclude the $χ$--electron ($χ$--$e$) elastic-scattering cross section $σ_{χe} \sim 5\times10^{-29}$ cm$^2$ for $χ$ with a mass $m_χ\lesssim$ 0.1 keV from our results. If ($m_χ$, $σ_{χe}$) can be determined in the future, DD experiments are expected to impose strong constraints on $f_{PBH}$ for large $M_{PBH}$s.
△ Less
Submitted 29 March, 2024;
originally announced March 2024.
-
Experimental Limits on Solar Reflected Dark Matter with a New Approach on Accelerated-Dark-Matter-Electron Analysis in Semiconductors
Authors:
Z. Y. Zhang,
L. T. Yang,
Q. Yue,
K. J. Kang,
Y. J. Li,
H. P. An,
Greeshma C.,
J. P. Chang,
Y. H. Chen,
J. P. Cheng,
W. H. Dai,
Z. Deng,
C. H. Fang,
X. P. Geng,
H. Gong,
Q. J. Guo,
T. Guo,
X. Y. Guo,
L. He,
S. M. He,
J. W. Hu,
H. X. Huang,
T. C. Huang,
L. Jiang,
S. Karmakar
, et al. (59 additional authors not shown)
Abstract:
Recently a dark matter-electron (DM-electron) paradigm has drawn much attention. Models beyond the standard halo model describing DM accelerated by high energy celestial bodies are under intense examination as well. In this Letter, a velocity components analysis (VCA) method dedicated to swift analysis of accelerated DM-electron interactions via semiconductor detectors is proposed and the first HP…
▽ More
Recently a dark matter-electron (DM-electron) paradigm has drawn much attention. Models beyond the standard halo model describing DM accelerated by high energy celestial bodies are under intense examination as well. In this Letter, a velocity components analysis (VCA) method dedicated to swift analysis of accelerated DM-electron interactions via semiconductor detectors is proposed and the first HPGe detector-based accelerated DM-electron analysis is realized. Utilizing the method, the first germanium based constraint on sub-GeV solar reflected DM-electron interaction is presented with the 205.4 kg$\cdot$day dataset from the CDEX-10 experiment. In the heavy mediator scenario, our result excels in the mass range of 5$-$15 keV/$c^2$, achieving a 3 orders of magnitude improvement comparing with previous semiconductor experiments. In the light mediator scenario, the strongest laboratory constraint for DM lighter than 0.1 MeV/$c^2$ is presented. The result proves the feasibility and demonstrates the vast potential of the VCA technique in future accelerated DM-electron analyses with semiconductor detectors.
△ Less
Submitted 24 April, 2024; v1 submitted 26 September, 2023;
originally announced September 2023.
-
Projected WIMP sensitivity of the CDEX-50 dark matter experiment
Authors:
X. P. Geng,
L. T. Yang,
Q. Yue,
K. J. Kang,
Y. J. Li,
H. P. An,
Greeshma C.,
J. P. Chang,
Y. H. Chen,
J. P. Cheng,
W. H. Dai,
Z. Deng,
C. H. Fang,
H. Gong,
Q. J. Guo,
T. Guo,
X. Y. Guo,
L. He,
S. M. He,
J. W. Hu,
H. X. Huang,
T. C. Huang,
L. Jiang,
S. Karmakar,
H. B. Li
, et al. (59 additional authors not shown)
Abstract:
CDEX-50 is a next-generation project of the China Dark Matter Experiment (CDEX) that aims to search for dark matter using a 50-kg germanium detector array. This paper comprises a thorough summary of the CDEX-50 dark matter experiment, including an investigation of potential background sources and the development of a background model. Based on the baseline model, the projected sensitivity of weakl…
▽ More
CDEX-50 is a next-generation project of the China Dark Matter Experiment (CDEX) that aims to search for dark matter using a 50-kg germanium detector array. This paper comprises a thorough summary of the CDEX-50 dark matter experiment, including an investigation of potential background sources and the development of a background model. Based on the baseline model, the projected sensitivity of weakly interacting massive particle (WIMP) is also presented. The expected background level within the energy region of interest, set to 2--2.5 keVee, is $\sim$0.01 counts keVee$^{-1}$ kg$^{-1}$ day$^{-1}$. At 90\% confidence level, the expected sensitivity to spin-independent WIMP-nucleon couplings is estimated to reach a cross-section of 5.1 $\times$ 10$^{-45}$ cm$^{2}$ for a WIMP mass of 5 GeV/c$^{2}$ with an exposure objective of 150 kg$\cdot$year and an analysis threshold of 160 eVee. This science goal will correspond to the most sensitive results for WIMPs with a mass of 2.2--8 GeV/c$^{2}$.
△ Less
Submitted 4 July, 2024; v1 submitted 4 September, 2023;
originally announced September 2023.
-
Searching for $^{76}$Ge neutrinoless double beta decay with the CDEX-1B experiment
Authors:
B. T. Zhang,
L. T. Yang,
Q. Yue,
K. J. Kang,
Y. J. Li,
H. P. An,
Greeshma C.,
J. P. Chang,
Y. H. Chen,
J. P. Cheng,
W. H. Dai,
Z. Deng,
C. H. Fang,
X. P. Geng,
H. Gong,
Q. J. Guo,
X. Y. Guo,
L. He,
S. M. He,
J. W. Hu,
H. X. Huang,
T. C. Huang,
H. T. Jia,
X. Jiang,
S. Karmakar
, et al. (59 additional authors not shown)
Abstract:
We operated a p-type point contact high purity germanium (PPCGe) detector (CDEX-1B, 1.008 kg) in the China **** Underground Laboratory (CJPL) for 500.3 days to search for neutrinoless double beta ($0νββ$) decay of $^{76}$Ge. A total of 504.3 kg $\cdot$ day effective exposure data was accumulated. The anti-coincidence and the multi/single-site event (MSE/SSE) discrimination methods were used to…
▽ More
We operated a p-type point contact high purity germanium (PPCGe) detector (CDEX-1B, 1.008 kg) in the China **** Underground Laboratory (CJPL) for 500.3 days to search for neutrinoless double beta ($0νββ$) decay of $^{76}$Ge. A total of 504.3 kg $\cdot$ day effective exposure data was accumulated. The anti-coincidence and the multi/single-site event (MSE/SSE) discrimination methods were used to suppress the background in the energy region of interest (ROI, $1989-2089$ keV for this work) with a factor of 23. A background level of 0.33 counts/(keV $\cdot$ kg $\cdot$ yr) was achieved. The lower limit on the half life of $^{76}$Ge $0νββ$ decay was constrained as $T_{1/2}^{0ν}\ > \ {2.2}\times 10^{23}\ \rm yr\ (90\% \ C.L.)$, corresponding to the upper limits on the effective Majorana neutrino mass: $\langle m_{ββ}\rangle < 2.3-5.2\ \mathrm{eV}$.
△ Less
Submitted 8 May, 2023; v1 submitted 1 May, 2023;
originally announced May 2023.
-
Search for boosted keV-MeV light dark matter particles from evaporating primordial black holes at the CDEX-10 experiment
Authors:
Z. H. Zhang,
L. T. Yang,
Q. Yue,
K. J. Kang,
Y. J. Li,
H. P. An,
Greeshma C.,
J. P. Chang,
Y. H. Chen,
J. P. Cheng,
W. H. Dai,
Z. Deng,
C. H. Fang,
X. P. Geng,
H. Gong,
Q. J. Guo,
X. Y. Guo,
L. He,
S. M. He,
J. W. Hu,
H. X. Huang,
T. C. Huang,
H. T. Jia,
X. Jiang,
S. Karmakar
, et al. (59 additional authors not shown)
Abstract:
We present novel constraints on boosted light dark matter particles (denoted as ``$χ$'') from evaporating primordial black holes (PBHs) using 205.4 kg$\cdot$day data from the China **** Underground Laboratory's CDEX-10 p-type point contact germanium detector with a 160 eVee analysis threshold. $χ$ from PBHs with masses ranging from 1$\times$10$^{15}$ g to 7$\times$10$^{16}$ g are searched in th…
▽ More
We present novel constraints on boosted light dark matter particles (denoted as ``$χ$'') from evaporating primordial black holes (PBHs) using 205.4 kg$\cdot$day data from the China **** Underground Laboratory's CDEX-10 p-type point contact germanium detector with a 160 eVee analysis threshold. $χ$ from PBHs with masses ranging from 1$\times$10$^{15}$ g to 7$\times$10$^{16}$ g are searched in this work. In the presence of PBH abundance compatible with present bounds, our result excludes the $χ$-nucleon elastic-scattering cross section region from 3.4$\times$10$^{-32}$ cm$^{2}$ to 2.3$\times$10$^{-29}$ cm$^{2}$ for $χ$ of 1 keV to 24 MeV from PBHs with masses of 5$\times$10$^{15}$ g, as well as from 1.1$\times$10$^{-28}$ cm$^{2}$ to 7.6$\times$10$^{-28}$ cm$^{2}$ for $χ$ of 1 keV to 0.6 MeV from PBHs with masses of 7$\times$10$^{16}$ g. If the $χ$-nucleon elastic-scattering cross section can be determined in the future, the abundance of PBHs may be severely constrained by $χ$ evaporation. With the lower threshold (160 eVee) of the CDEX-10 experiment compared to the previously used experiments, this work allows for a better reach at soft spectra produced by heavier PBHs, which demonstrates the vast potential of such a technical route to pursue $χ$ from larger PBHs with a low threshold.
△ Less
Submitted 7 September, 2023; v1 submitted 14 November, 2022;
originally announced November 2022.
-
Search for exotic interactions of solar neutrinos in the CDEX-10 experiment
Authors:
X. P. Geng,
L. T. Yang,
Q. Yue,
K. J. Kang,
Y. J. Li,
H. P. An,
Greeshma C.,
J. P. Chang,
Y. H. Chen,
J. P. Cheng,
W. H. Dai,
Z. Deng,
C. H. Fang,
H. Gong,
Q. J. Guo,
X. Y. Guo,
L. He,
S. M. He,
J. W. Hu,
H. X. Huang,
T. C. Huang,
H. T. Jia,
X. Jiang,
S. Karmakar,
H. B. Li
, et al. (60 additional authors not shown)
Abstract:
We investigate exotic neutrino interactions using the 205.4 kg$\cdot$day dataset from the CDEX-10 experiment at the China **** Underground Laboratory. New constraints on the mass and couplings of new gauge bosons are presented. Two nonstandard neutrino interactions are considered: a $U(1)_{B-L}$ gauge-boson-induced interaction between an active neutrino and electron/nucleus, and a dark-photon-i…
▽ More
We investigate exotic neutrino interactions using the 205.4 kg$\cdot$day dataset from the CDEX-10 experiment at the China **** Underground Laboratory. New constraints on the mass and couplings of new gauge bosons are presented. Two nonstandard neutrino interactions are considered: a $U(1)_{B-L}$ gauge-boson-induced interaction between an active neutrino and electron/nucleus, and a dark-photon-induced interaction between a sterile neutrino and electron/nucleus via kinetic mixing with a photon. This work probes an unexplored parameter space involving sterile neutrino coupling with a dark photon. New laboratory limits are derived on dark photon masses below $1~{\rm eV}/c^{2}$ at some benchmark values of $Δm_{41}^{2}$ and $g^{\prime2}{\rm{sin}}^{2}2θ_{14}$.
△ Less
Submitted 2 June, 2023; v1 submitted 4 October, 2022;
originally announced October 2022.
-
Exotic Dark Matter Search with CDEX-10 Experiment at China's **** Underground Laboratory
Authors:
W. H. Dai,
L. P. Jia,
H. Ma,
Q. Yue,
K. J. Kang,
Y. J. Li,
H. P. An,
Greeshma C.,
J. P. Chang,
Y. H. Chen,
J. P. Cheng,
Z. Deng,
C. H. Fang,
X. P. Geng,
H. Gong,
Q. J. Guo,
X. Y. Guo,
L. He,
S. M. He,
J. W. Hu,
H. X. Huang,
T. C. Huang,
H. T. Jia,
X. Jiang,
S. Karmakar
, et al. (59 additional authors not shown)
Abstract:
A search for exotic dark matter (DM) in the sub-GeV mass range has been conducted using 205 kg$\cdot$day data taken from a p-type point contact germanium detector of CDEX-10 experiment at China **** underground laboratory. New low-mass dark matter searching channels, neutral current fermionic DM absorption ($χ+A\rightarrow ν+A$) and DM-nucleus 3$\rightarrow$2 scattering ($χ+χ+A\rightarrow φ+A$)…
▽ More
A search for exotic dark matter (DM) in the sub-GeV mass range has been conducted using 205 kg$\cdot$day data taken from a p-type point contact germanium detector of CDEX-10 experiment at China **** underground laboratory. New low-mass dark matter searching channels, neutral current fermionic DM absorption ($χ+A\rightarrow ν+A$) and DM-nucleus 3$\rightarrow$2 scattering ($χ+χ+A\rightarrow φ+A$), have been analyzed with an energy threshold of 160 eVee. No significant signal was found. Thus new limits on the DM-nucleon interaction cross section are set for both models at sub-GeV DM mass region. A cross section limit for the fermionic DM absorption is set to be $\rm 2.5\times 10^{-46} cm^2$(90\% C.L.) at DM mass of 10 MeV/c$^2$. For the DM-nucleus 3$\rightarrow$2 scattering scenario, limits are extended to DM mass of 5 MeV/c$^2$ and 14 MeV/c$^2$ for the massless dark photon and bound DM final state, respectively.
△ Less
Submitted 23 November, 2022; v1 submitted 2 September, 2022;
originally announced September 2022.
-
Constraints on Sub-GeV Dark Matter--Electron Scattering from the CDEX-10 Experiment
Authors:
Z. Y. Zhang,
L. T. Yang,
Q. Yue,
K. J. Kang,
Y. J. Li,
M. Agartioglu,
H. P. An,
J. P. Chang,
Y. H. Chen,
J. P. Cheng,
W. H. Dai,
Z. Deng,
C. H. Fang,
X. P. Geng,
H. Gong,
Q. J. Guo,
X. Y. Guo,
L. He,
S. M. He,
J. W. Hu,
H. X. Huang,
T. C. Huang,
H. T. Jia,
X. Jiang,
H. B. Li
, et al. (60 additional authors not shown)
Abstract:
We present improved germanium-based constraints on sub-GeV dark matter via dark matter--electron ($χ$-$e$) scattering using the 205.4 kg$\cdot$day dataset from the CDEX-10 experiment. Using a novel calculation technique, we attain predicted $χ$-$e$ scattering spectra observable in high-purity germanium detectors. In the heavy mediator scenario, our results achieve 3 orders of magnitude of improvem…
▽ More
We present improved germanium-based constraints on sub-GeV dark matter via dark matter--electron ($χ$-$e$) scattering using the 205.4 kg$\cdot$day dataset from the CDEX-10 experiment. Using a novel calculation technique, we attain predicted $χ$-$e$ scattering spectra observable in high-purity germanium detectors. In the heavy mediator scenario, our results achieve 3 orders of magnitude of improvement for $m_χ$ larger than 80 MeV/c$^2$ compared to previous germanium-based $χ$-$e$ results. We also present the most stringent $χ$-$e$ cross-section limit to date among experiments using solid-state detectors for $m_χ$ larger than 90 MeV/c$^2$ with heavy mediators and $m_χ$ larger than 100 MeV/c$^2$ with electric dipole coupling. The result proves the feasibility and demonstrates the vast potential of a new $χ$-$e$ detection method with high-purity germanium detectors in ultralow radioactive background.
△ Less
Submitted 21 November, 2022; v1 submitted 8 June, 2022;
originally announced June 2022.
-
Search for Neutrinoless Double-Beta Decay of $^{76}$Ge with a Natural Broad Energy Germanium Detector
Authors:
CDEX collaboration,
W. H. Dai,
H. Ma,
Q. Yue,
Z. She,
K. J. Kang,
Y. J. Li,
M. Agartioglu,
H. P. An,
J. P. Chang,
Y. H. Chen,
J. P. Cheng,
Z. Deng,
C. H. Fang,
X. P. Geng,
H. Gong,
Q. J. Guo,
X. Y. Guo,
L. He,
S. M. He,
J. W. Hu,
H. X. Huang,
T. C. Huang,
H. T. Jia,
X. Jiang
, et al. (61 additional authors not shown)
Abstract:
A natural broad energy germanium (BEGe) detector is operated in the China **** Underground Laboratory (CJPL) for a feasibility study of building the next generation experiment of the neutrinoless double-beta (0{$νββ$}) decay of $^{76}$Ge. The setup of the prototype facility, characteristics of the BEGe detector, background reduction methods, and data analysis are described in this paper. A back…
▽ More
A natural broad energy germanium (BEGe) detector is operated in the China **** Underground Laboratory (CJPL) for a feasibility study of building the next generation experiment of the neutrinoless double-beta (0{$νββ$}) decay of $^{76}$Ge. The setup of the prototype facility, characteristics of the BEGe detector, background reduction methods, and data analysis are described in this paper. A background index of 6.4$\times$10$^{-3}$ counts/(keV$\cdot$kg$\cdot$day) is achieved and 1.86 times lower than our previous result of the CDEX-1 detector. No signal is observed with an exposure of 186.4 kg$\cdot$day, thus a limit on the half life of $^{76}$Ge 0$νββ$ decay is set at T$_{1/2}^{0ν}$ $>$ 5.62$\times$10$^{22}$ yr at 90% C.L.. The limit corresponds to an effective Majorana neutrino mass in the range of 4.6 $\sim$ 10.3 eV, dependent on the nuclear matrix elements.
△ Less
Submitted 5 August, 2022; v1 submitted 21 May, 2022;
originally announced May 2022.
-
Study of background from accidental coincidence signals in the PandaX-II experiment
Authors:
PandaX-II Collaboration,
:,
Abdusalam Abdukerim,
Wei Chen,
Xun Chen,
Yunhua Chen,
Chen Cheng,
Xiangyi Cui,
Yingjie Fan,
Deqing Fang,
Changbo Fu,
Mengting Fu,
Lisheng Geng,
Karl Giboni,
Linhui Gu,
Xuyuan Guo,
Ke Han,
Changda He,
Di Huang,
Yan Huang,
Yanlin Huang,
Zhou Huang,
Xiangdong Ji,
Yonglin Ju,
Shuaijie Li
, et al. (42 additional authors not shown)
Abstract:
The PandaX-II experiment employed a 580kg liquid xenon detector to search for the interactions between dark matter particles and the target xenon atoms. The accidental coincidences of isolated signals result in a dangerous background which mimic the signature of the dark matter. We performed a detailed study on the accidental coincidence background in PandaX-II, including the possible origin of th…
▽ More
The PandaX-II experiment employed a 580kg liquid xenon detector to search for the interactions between dark matter particles and the target xenon atoms. The accidental coincidences of isolated signals result in a dangerous background which mimic the signature of the dark matter. We performed a detailed study on the accidental coincidence background in PandaX-II, including the possible origin of the isolated signals, the background level and corresponding background suppression method. With a boosted-decision-tree algorithm, the accidental coincidence background is reduced by 70% in the dark matter signal region, thus the sensitivity of dark matter search at PandaX-II is improved.
△ Less
Submitted 1 July, 2022; v1 submitted 23 April, 2022;
originally announced April 2022.
-
Constraints on sub-GeV dark matter boosted by cosmic rays from the CDEX-10 experiment at the China **** Underground Laboratory
Authors:
R. Xu,
L. T. Yang,
Q. Yue,
K. J. Kang,
Y. J. Li,
M. Agartioglu,
H. P. An,
J. P. Chang,
Y. H. Chen,
J. P. Cheng,
W. H. Dai,
Z. Deng,
C. H. Fang,
X. P. Geng,
H. Gong,
X. Y. Guo,
Q. J. Guo,
L. He,
S. M. He,
J. W. Hu,
H. X. Huang,
T. C. Huang,
H. T. Jia,
X. Jiang,
H. B. Li
, et al. (60 additional authors not shown)
Abstract:
We present new constraints on light dark matter boosted by cosmic rays (CRDM) using the 205.4 kg day data of the CDEX-10 experiment conducted at the China **** Underground Laboratory. The Monte Carlo simulation package CJPL\_ESS was employed to evaluate the Earth shielding effect. Several key factors have been introduced and discussed in our CRDM analysis, including the contributions from heavi…
▽ More
We present new constraints on light dark matter boosted by cosmic rays (CRDM) using the 205.4 kg day data of the CDEX-10 experiment conducted at the China **** Underground Laboratory. The Monte Carlo simulation package CJPL\_ESS was employed to evaluate the Earth shielding effect. Several key factors have been introduced and discussed in our CRDM analysis, including the contributions from heavier CR nuclei than proton and helium, the inhomogeneity of CR distribution, and the impact of the form factor in the Earth attenuation calculation. Our result excludes the dark matter--nucleon elastic scattering cross-section region from $1.7\times 10^{-30}$ to $10^{-26}~\rm cm^2$ for dark matter of 10 keV$/c^2$ to 1 GeV$/c^2$.
△ Less
Submitted 16 September, 2022; v1 submitted 5 January, 2022;
originally announced January 2022.
-
Studies of the Earth shielding effect to direct dark matter searches at the China **** Underground Laboratory
Authors:
Z. Z. Liu,
L. T. Yang,
Q. Yue,
C. H. Yeh,
K. J. Kang,
Y. J. Li,
M. Agartioglu,
H. P. An,
J. P. Chang,
J. H. Chen,
Y. H. Chen,
J. P. Cheng,
W. H. Dai,
Z. Deng,
C. H. Fang,
X. P. Geng,
H. Gong,
X. Y. Guo,
Q. J. Guo,
L. He,
S. M. He,
J. W. Hu,
H. X. Huang,
T. C. Huang,
H. T. Jia
, et al. (58 additional authors not shown)
Abstract:
Dark matter direct detection experiments mostly operate at deep underground laboratories. It is necessary to consider shielding effect of the Earth, especially for dark matter particles interacting with a large cross section. We analyzed and simulated the Earth shielding effect for dark matter at the China **** Underground Laboratory (CJPL) with a simulation package, CJPL Earth Shielding Simula…
▽ More
Dark matter direct detection experiments mostly operate at deep underground laboratories. It is necessary to consider shielding effect of the Earth, especially for dark matter particles interacting with a large cross section. We analyzed and simulated the Earth shielding effect for dark matter at the China **** Underground Laboratory (CJPL) with a simulation package, CJPL Earth Shielding Simulation code (CJPL\_ESS), which is applicable to other underground locations. The further constraints on the $χ$-N cross section exclusion regions are derived based on the studies with CDEX experiment data.
△ Less
Submitted 9 March, 2022; v1 submitted 22 November, 2021;
originally announced November 2021.
-
Horizontal Position Reconstruction in PandaX-II
Authors:
Dan Zhang,
Andi Tan,
Abdusalam Abdukerim,
Wei Chen,
Xun Chen,
Yunhua Chen,
Chen Cheng,
Xiangyi Cui,
Yingjie Fan,
Deqing Fang,
Changbo Fu,
Mengting Fu,
Lisheng Geng,
Karl Giboni,
Linhui Gu,
Xuyuan Guo,
Ke Han,
Changda He,
Shengming He,
Di Huang,
Yan Huang,
Yanlin Huang,
Zhou Huang,
Xiangdong Ji,
Yonglin Ju
, et al. (47 additional authors not shown)
Abstract:
Dual-phase noble-gas time projection chambers (TPCs) have improved the sensitivities for dark matter direct search in past decades. The capability of TPCs to reconstruct 3-D vertexes of keV scale recoilings is one of the most advantageous features. In this work, we develop two horizontal position reconstruction algorithms for the PandaX-II dark matter search experiment using the dual-phase liquid…
▽ More
Dual-phase noble-gas time projection chambers (TPCs) have improved the sensitivities for dark matter direct search in past decades. The capability of TPCs to reconstruct 3-D vertexes of keV scale recoilings is one of the most advantageous features. In this work, we develop two horizontal position reconstruction algorithms for the PandaX-II dark matter search experiment using the dual-phase liquid xenon TPC. Both algorithms are optimized by the $^{83m}$Kr calibration events and use photon distribution of ionization signals among photomultiplier tubes to infer the positions. According to the events coming from the gate electrode, the uncertainties in the horizontal positions are 3.4 mm (3.9 mm) in the analytical (simulation-based) algorithm for an ionization signal with several thousand photon electrons in the center of the TPC
△ Less
Submitted 7 October, 2021; v1 submitted 15 June, 2021;
originally announced June 2021.
-
Constraining self-interacting dark matter with the full dataset of PandaX-II
Authors:
Jijun Yang,
Abdusalam Abdukerim,
Wei Chen,
Xun Chen,
Yunhua Chen,
Chen Cheng,
Xiangyi Cui,
Yingjie Fan,
Deqing Fang,
Changbo Fu,
Mengting Fu,
Lisheng Geng,
Karl Giboni,
Linhui Gu,
Xuyuan Guo,
Ke Han,
Changda He,
Shengming He,
Di Huang,
Yan Huang,
Ran Huo,
Yanlin Huang,
Zhou Huang,
Xiangdong Ji,
Yonglin Ju
, et al. (47 additional authors not shown)
Abstract:
Self-interacting Dark Matter (SIDM) is a leading candidate proposed to solve discrepancies between predictions of the prevailing cold dark matter theory and observations of galaxies. Many SIDM models predict the existence of a light force carrier that mediate strong dark matter self-interactions. If the mediator couples to the standard model particles, it could produce characteristic signals in da…
▽ More
Self-interacting Dark Matter (SIDM) is a leading candidate proposed to solve discrepancies between predictions of the prevailing cold dark matter theory and observations of galaxies. Many SIDM models predict the existence of a light force carrier that mediate strong dark matter self-interactions. If the mediator couples to the standard model particles, it could produce characteristic signals in dark matter direct detection experiments. We report searches for SIDM models with a light mediator using the full dataset of the PandaX-II experiment, based on a total exposure of 132 tonne-days. No significant excess over background is found, and our likelihood analysis leads to a strong upper limit on the dark matter-nucleon coupling strength. We further combine the PandaX-II constraints and those from observations of the light element abundances in the early universe, and show that direct detection and cosmological probes can provide complementary constraints on dark matter models with a light mediator.
△ Less
Submitted 24 October, 2021; v1 submitted 29 April, 2021;
originally announced April 2021.
-
Search for Light Dark Matter-Electron Scatterings in the PandaX-II Experiment
Authors:
Chen Cheng,
Pengwei Xie,
Abdusalam Abdukerim,
Wei Chen,
Xun Chen,
Yunhua Chen,
Xiangyi Cui,
Yingjie Fan,
Deqing Fang,
Changbo Fu,
Mengting Fu,
Lisheng Geng,
Karl Giboni,
Linhui Gu,
Xuyuan Guo,
Ke Han,
Changda He,
Di Huang,
Yan Huang,
Yanlin Huang,
Zhou Huang,
Xiangdong Ji,
Yonglin Ju,
Shuaijie Li,
Qing Lin
, et al. (45 additional authors not shown)
Abstract:
We report constraints on light dark matter through its interactions with shell electrons in the PandaX-II liquid xenon detector with a total 46.9 tonne$\cdot$day exposure. To effectively search for these very low energy electron recoils, ionization-only signals are selected from the data. 1821 candidates are identified within ionization signal range between 50 to 75 photoelectrons, corresponding t…
▽ More
We report constraints on light dark matter through its interactions with shell electrons in the PandaX-II liquid xenon detector with a total 46.9 tonne$\cdot$day exposure. To effectively search for these very low energy electron recoils, ionization-only signals are selected from the data. 1821 candidates are identified within ionization signal range between 50 to 75 photoelectrons, corresponding to a mean electronic recoil energy from 0.08 to 0.15 keV. The 90% C.L. exclusion limit on the scattering cross section between the dark matter and electron is calculated based on Poisson statistics. Under the assumption of point interaction, we provide the world's most stringent limit within the dark matter mass range from 15 to 30 $\rm MeV/c^2$, with the corresponding cross section from $2.5\times10^{-37}$ to $3.1\times10^{-38}$ cm$^2$.
△ Less
Submitted 7 May, 2021; v1 submitted 19 January, 2021;
originally announced January 2021.
-
A search for solar axions and anomalous neutrino magnetic moment with the complete PandaX-II data
Authors:
Xiaopeng Zhou,
Xinning Zeng,
Xuyang Ning,
Abdusalam Abdukerim,
Wei Chen,
Xun Chen,
Yunhua Chen,
Chen Cheng,
Xiangyi Cui,
Yingjie Fan,
Deqing Fang,
Changbo Fu,
Mengting Fu,
Lisheng Geng,
Karl Giboni,
Linhui Gu,
Xuyuan Guo,
Ke Han,
Changda He,
Di Huang,
Yan Huang,
Yanlin Huang,
Zhou Huang,
Xiangdong Ji,
Yonglin Ju
, et al. (41 additional authors not shown)
Abstract:
We report a search for new physics signals using the low energy electron recoil events in the complete data set from PandaX-II, in light of the recent event excess reported by XENON1T. The data correspond to a total exposure of 100.7 ton-day with liquid xenon. With robust estimates of the dominant background spectra, we perform sensitive searches on solar axions and neutrinos with enhanced magneti…
▽ More
We report a search for new physics signals using the low energy electron recoil events in the complete data set from PandaX-II, in light of the recent event excess reported by XENON1T. The data correspond to a total exposure of 100.7 ton-day with liquid xenon. With robust estimates of the dominant background spectra, we perform sensitive searches on solar axions and neutrinos with enhanced magnetic moment. We find that the axion-electron coupling $g_{Ae}<4.6\times 10^{-12}$ for an axion mass less than $\rm 0.1~keV/c^2$ and the neutrino magnetic moment $μ_ν<4.9\times 10^{-11}μ_{B}$ at 90% confidence level. The observed excess from XENON1T is within our experimental constraints.
△ Less
Submitted 23 November, 2021; v1 submitted 14 August, 2020;
originally announced August 2020.
-
First experimental constraints on WIMP couplings in the effective field theory framework from CDEX
Authors:
Y. Wang,
Z. Zeng,
Q. Yue,
L. T. Yang,
K. J. Kang,
Y. J. Li,
M. Agartioglu,
H. P. An,
J. P. Chang,
J. H. Chen,
Y. H. Chen,
J. P. Cheng,
C. Y. Chiang,
W. H. Dai,
Z. Deng,
C. H. Fang,
X. P. Geng,
H. Gong,
Q. J. Guo,
X. Y. Guo,
H. J. He,
L. He,
S. M. He,
J. W. Hu,
T. C. Huang
, et al. (63 additional authors not shown)
Abstract:
We present weakly interacting massive particles (WIMPs) search results performed using two approaches of effective field theory from the China Dark Matter Experiment (CDEX), based on the data from both CDEX-1B and CDEX-10 stages. In the nonrelativistic effective field theory approach, both time-integrated and annual modulation analyses were used to set new limits for the coupling of WIMP-nucleon e…
▽ More
We present weakly interacting massive particles (WIMPs) search results performed using two approaches of effective field theory from the China Dark Matter Experiment (CDEX), based on the data from both CDEX-1B and CDEX-10 stages. In the nonrelativistic effective field theory approach, both time-integrated and annual modulation analyses were used to set new limits for the coupling of WIMP-nucleon effective operators at 90% confidence level (C.L.) and improve over the current bounds in the low $m_χ$ region. In the chiral effective field theory approach, data from CDEX-10 were used to set an upper limit on WIMP-pion coupling at 90% C.L. We for the first time extended the limit to the $m_χ<$ 6 GeV/$c^2$ region.
△ Less
Submitted 26 April, 2021; v1 submitted 30 July, 2020;
originally announced July 2020.
-
Results of Dark Matter Search using the Full PandaX-II Exposure
Authors:
Qiuhong Wang,
Abdusalam Abdukerim,
Wei Chen,
Xun Chen,
Yunhua Chen,
Chen Cheng,
Xiangyi Cui,
Yingjie Fan,
Deqing Fang,
Changbo Fu,
Mengting Fu,
Lisheng Geng,
Karl Giboni,
Linhui Gu,
Xuyuan Guo,
Ke Han,
Changda He,
Di Huang,
Yan Huang,
Yanlin Huang,
Zhou Huang,
Xiangdong Ji,
Yonglin Ju,
Shuaijie Li,
Huaxuan Liu
, et al. (40 additional authors not shown)
Abstract:
We report the dark matter search results obtained using the full 132 ton$\cdot$day exposure of the PandaX-II experiment, including all data from March 2016 to August 2018. No significant excess of events is identified above the expected background. Upper limits are set on the spin-independent dark matter-nucleon interactions. The lowest 90% confidence level exclusion on the spin-independent cross…
▽ More
We report the dark matter search results obtained using the full 132 ton$\cdot$day exposure of the PandaX-II experiment, including all data from March 2016 to August 2018. No significant excess of events is identified above the expected background. Upper limits are set on the spin-independent dark matter-nucleon interactions. The lowest 90% confidence level exclusion on the spin-independent cross section is $2.2\times 10^{-46}$ cm$^2$ at a WIMP mass of 30 GeV/$c^2$.
△ Less
Submitted 1 January, 2021; v1 submitted 30 July, 2020;
originally announced July 2020.
-
Internal Calibration of the PandaX-II Detector with Radon Gaseous Sources
Authors:
Wenbo Ma,
Abdusalam Abdukerim,
Zihao Bo,
Wei Chen,
Xun Chen,
Yunhua Chen,
Chen Cheng,
Xiangyi Cui,
Yingjie Fan,
Deqing Fang,
Changbo Fu,
Mengting Fu,
Lisheng Geng,
Karl Giboni,
Linhui Gu,
Xuyuan Guo,
Ke Han,
Changda He,
Shengming He,
Di Huang,
Yan Huang,
Yanlin Huang,
Zhou Huang,
Xiangdong Ji,
Yonglin Ju
, et al. (43 additional authors not shown)
Abstract:
We have developed a low-energy electron recoil (ER) calibration method with $^{220}$Rn for the PandaX-II detector. $^{220}$Rn, emanated from natural thorium compounds, was fed into the detector through the xenon purification system. From 2017 to 2019, we performed three dedicated calibration campaigns with different radon sources. We studied the detector response to $α$, $β$, and $γ$ particles wit…
▽ More
We have developed a low-energy electron recoil (ER) calibration method with $^{220}$Rn for the PandaX-II detector. $^{220}$Rn, emanated from natural thorium compounds, was fed into the detector through the xenon purification system. From 2017 to 2019, we performed three dedicated calibration campaigns with different radon sources. We studied the detector response to $α$, $β$, and $γ$ particles with focus on low energy ER events. During the runs in 2017 and 2018, the amount of radioactivity of $^{222}$Rn were on the order of 1\% of that of $^{220}$Rn and thorium particulate contamination was negligible, especially in 2018. We also measured the background contribution from $^{214}$Pb for the first time in PandaX-II with the help from a $^{222}$Rn injection. Calibration strategy with $^{220}$Rn and $^{222}$Rn will be implemented in the upcoming PandaX-4T experiment and can be useful for other xenon-based detectors as well.
△ Less
Submitted 4 January, 2021; v1 submitted 16 June, 2020;
originally announced June 2020.
-
Improved limits on solar axions and bosonic dark matter from the CDEX-1B experiment using the profile likelihood ratio method
Authors:
Y. Wang,
Q. Yue,
S. K. Liu,
K. J. Kang,
Y. J. Li,
H. P. An,
J. P. Chang,
J. H. Chen,
Y. H. Chen,
J. P. Cheng,
W. H. Dai,
Z. Deng,
X. P. Geng,
H. Gong,
P. Gu,
X. Y. Guo,
H. T. He,
L. He,
S. M. He,
J. W. Hu,
H. X. Huang,
T. C. Huang,
L. P. Jia,
H. B. Li,
H. Li
, et al. (55 additional authors not shown)
Abstract:
We present the improved constraints on couplings of solar axions and more generic bosonic dark matter particles using 737.1 kg-days of data from the CDEX-1B experiment. The CDEX-1B experiment, located at the China **** Underground Laboratory, primarily aims at the direct detection of weakly interacting massive particles using a p-type point-contact germanium detector. We adopt the profile likel…
▽ More
We present the improved constraints on couplings of solar axions and more generic bosonic dark matter particles using 737.1 kg-days of data from the CDEX-1B experiment. The CDEX-1B experiment, located at the China **** Underground Laboratory, primarily aims at the direct detection of weakly interacting massive particles using a p-type point-contact germanium detector. We adopt the profile likelihood ratio method for analysis of data in the presence of backgrounds. An energy threshold of 160 eV was achieved, much better than the 475 eV of CDEX-1A with an exposure of 335.6 kg-days. This significantly improves the sensitivity for the bosonic dark matter below 0.8 keV among germanium detectors. Limits are also placed on the coupling $g_{Ae} < 2.48 \times 10^{-11}$ from Compton, bremsstrahlung, atomic-recombination and de-excitation channels and $g^{eff}_{AN} \times g_{Ae} < 4.14 \times 10^{-17}$ from a $^{57}$Fe M1 transition at 90\% confidence level.
△ Less
Submitted 26 April, 2021; v1 submitted 8 November, 2019;
originally announced November 2019.
-
Direct Detection Constraints on Dark Photons with CDEX-10 Experiment at the China **** Underground Laboratory
Authors:
Z. She,
L. P. Jia,
Q. Yue,
H. Ma,
K. J. Kang,
Y. J. Li,
M. Agartioglu,
H. P. An,
J. P. Chang,
J. H. Chen,
Y. H. Chen,
J. P. Cheng,
W. H. Dai,
Z. Deng,
X. P. Geng,
H. Gong,
P. Gu,
Q. J. Guo,
X. Y. Guo,
L. He,
S. M. He,
H. T. He,
J. W. Hu,
T. C. Huang,
H. X. Huang
, et al. (59 additional authors not shown)
Abstract:
We report constraints on the dark photon effective kinetic mixing parameter ($κ$) with data taken from two ${p}$-type point-contact germanium detectors of the CDEX-10 experiment at the China **** Underground Laboratory. The 90\% confidence level upper limits on $κ$ of solar dark photon from 205.4 kg-day exposure are derived, probing new parameter space with masses (${m_V}$) from 10 to 300 eV/…
▽ More
We report constraints on the dark photon effective kinetic mixing parameter ($κ$) with data taken from two ${p}$-type point-contact germanium detectors of the CDEX-10 experiment at the China **** Underground Laboratory. The 90\% confidence level upper limits on $κ$ of solar dark photon from 205.4 kg-day exposure are derived, probing new parameter space with masses (${m_V}$) from 10 to 300 eV/${c^2}$ in direct detection experiments. Considering dark photon as the cosmological dark matter, limits at 90\% confidence level with ${m_V}$ from 0.1 to 4.0 keV/${c^2}$ are set from 449.6 kg-day data, with a minimum of ${\rm{κ=1.3 \times 10^{-15}}}$ at ${\rm{m_V=200\ eV/c^2}}$.
△ Less
Submitted 18 March, 2020; v1 submitted 29 October, 2019;
originally announced October 2019.
-
An Improved Evaluation of the Neutron Background in the PandaX-II Experiment
Authors:
Qiuhong Wang,
Abdusalam Abdukerim,
Wei Chen,
Xun Chen,
Yunhua Chen,
Xiangyi Cui,
Yingjie Fan,
Deqing Fang,
Changbo Fu,
Lisheng Geng,
Karl Giboni,
Franco Giuliani,
Linhui Gu,
Xuyuan Guo,
Ke Han,
Changda He,
Di Huang,
Yan Huang,
Yanlin Huang,
Zhou Huang,
Peng Ji,
Xiangdong Ji,
Yonglin Ju,
Yihui Lai,
Kun Liang
, et al. (38 additional authors not shown)
Abstract:
In dark matter direct detection experiments, neutron is a serious source of background, which can mimic the dark matter-nucleus scattering signals. In this paper, we present an improved evaluation of the neutron background in the PandaX-II dark matter experiment by a novel approach. Instead of fully relying on the Monte Carlo simulation, the overall neutron background is determined from the neutro…
▽ More
In dark matter direct detection experiments, neutron is a serious source of background, which can mimic the dark matter-nucleus scattering signals. In this paper, we present an improved evaluation of the neutron background in the PandaX-II dark matter experiment by a novel approach. Instead of fully relying on the Monte Carlo simulation, the overall neutron background is determined from the neutron-induced high energy signals in the data. In addition, the probability of producing a dark-matter-like background per neutron is evaluated with a complete Monte Carlo generator, where the correlated emission of neutron(s) and $γ$(s) in the ($α$, n) reactions and spontaneous fissions is taken into consideration. With this method, the neutron backgrounds in the Run 9 (26-ton-day) and Run 10 (28-ton-day) data sets of PandaX-II are estimated to be 0.66$\pm$0.24 and 0.47$\pm$0.25 events, respectively.
△ Less
Submitted 24 July, 2019; v1 submitted 1 July, 2019;
originally announced July 2019.
-
Searching for Neutrino-less Double Beta Decay of $^{136}$Xe with PandaX-II Liquid Xenon Detector
Authors:
Kaixiang Ni,
Yihui Lai,
Abdusalam Abdukerim,
Wei Chen,
Xun Chen,
Yunhua Chen,
Xiangyi Cui,
Yingjie Fan,
Deqing Fang,
Changbo Fu,
Lisheng Geng,
Karl Giboni,
Franco Giuliani,
Linhui Gu,
Xuyuan Guo,
Ke Han,
Changda He,
Di Huang,
Yan Huang,
Yanlin Huang,
Zhou Huang,
Peng Ji,
Xiangdong Ji,
Yonglin Ju,
Kun Liang
, et al. (38 additional authors not shown)
Abstract:
We report the Neutrino-less Double Beta Decay (NLDBD) search results from PandaX-II dual-phase liquid xenon time projection chamber. The total live time used in this analysis is 403.1 days from June 2016 to August 2018. With NLDBD-optimized event selection criteria, we obtain a fiducial mass of 219 kg of natural xenon. The accumulated xenon exposure is 242 kg$\cdot$yr, or equivalently 22.2 kg…
▽ More
We report the Neutrino-less Double Beta Decay (NLDBD) search results from PandaX-II dual-phase liquid xenon time projection chamber. The total live time used in this analysis is 403.1 days from June 2016 to August 2018. With NLDBD-optimized event selection criteria, we obtain a fiducial mass of 219 kg of natural xenon. The accumulated xenon exposure is 242 kg$\cdot$yr, or equivalently 22.2 kg$\cdot$yr of $^{136}$Xe exposure. At the region around $^{136}$Xe decay Q-value of 2458 keV, the energy resolution of PandaX-II is 4.2%. We find no evidence of NLDBD in PandaX-II and establish a lower limit for decay half-life of 2.4 $ \times 10^{23} $ yr at the 90% confidence level, which corresponds to an effective Majorana neutrino mass $m_{ββ} < (1.3 - 3.5)$ eV. This is the first NLDBD result reported from a dual-phase xenon experiment.
△ Less
Submitted 27 June, 2019;
originally announced June 2019.
-
Constraints on Spin-Independent Nucleus Scattering with sub-GeV Weakly Interacting Massive Particle Dark Matter from the CDEX-1B Experiment at the China **-** Laboratory
Authors:
Z. Z. Liu,
Q. Yue,
L. T. Yang,
K. J. Kang,
Y. J. Li,
H. T. Wong,
M. Agartioglu,
H. P. An,
J. P. Chang,
J. H. Chen,
Y. H. Chen,
J. P. Cheng,
Z. Deng,
Q. Du,
H. Gong,
X. Y. Guo,
L. He,
S. M. He,
J. W. Hu,
Q. D. Hu,
H. X. Huang,
L. P. Jia,
H. Jiang,
H. B. Li,
H. Li
, et al. (46 additional authors not shown)
Abstract:
We report results on the searches of weakly interacting massive particles (WIMPs) with sub-GeV masses ($m_χ$) via WIMP-nucleus spin-independent scattering with Migdal effect incorporated. Analysis on time-integrated (TI) and annual modulation (AM) effects on CDEX-1B data are performed, with 737.1 kg$\cdot$day exposure and 160 eVee threshold for TI analysis, and 1107.5 kg$\cdot$day exposure and 250…
▽ More
We report results on the searches of weakly interacting massive particles (WIMPs) with sub-GeV masses ($m_χ$) via WIMP-nucleus spin-independent scattering with Migdal effect incorporated. Analysis on time-integrated (TI) and annual modulation (AM) effects on CDEX-1B data are performed, with 737.1 kg$\cdot$day exposure and 160 eVee threshold for TI analysis, and 1107.5 kg$\cdot$day exposure and 250 eVee threshold for AM analysis. The sensitive windows in $m_χ$ are expanded by an order of magnitude to lower DM masses with Migdal effect incorporated. New limits on $σ_{χN}^{\rm SI}$ at 90\% confidence level are derived as $2\times$10$^{-32}\sim7\times$10$^{-35}$ $\rm cm^2$ for TI analysis at $m_χ\sim$ 50$-$180 MeV/$c^2$, and $3\times$10$^{-32}\sim9\times$10$^{-38}$ $\rm cm^2$ for AM analysis at $m_χ\sim$75 MeV/$c^2-$3.0 GeV/$c^2$.
△ Less
Submitted 15 October, 2019; v1 submitted 1 May, 2019;
originally announced May 2019.
-
PandaX-II Constraints on Spin-Dependent WIMP-Nucleon Effective Interactions
Authors:
**gkai Xia,
Abdusalam Abdukerim,
Xun Chen,
Yunhua Chen,
Xiangyi Cui,
Deqing Fang,
Changbo Fu,
Karl Giboni,
Franco Giuliani,
Linhui Gu,
Xuyuan Guo,
Zhifan Guo,
Ke Han,
Changda He,
Shengming He,
Di Huang,
Xingtao Huang,
Zhou Huang,
Peng Ji,
Xiangdong Ji,
Yonglin Ju,
Shaoli Li,
Heng Lin,
Huaxuan Liu,
Jianglai Liu
, et al. (35 additional authors not shown)
Abstract:
We present PandaX-II constraints on candidate WIMP-nucleon effective interactions involving the nucleon or WIMP spin, including, in addition to standard axial spin-dependent (SD) scattering, various couplings among vector and axial currents, magnetic and electric dipole moments, and tensor interactions. The data set corresponding to a total exposure of 54-ton-days is reanalyzed to determine constr…
▽ More
We present PandaX-II constraints on candidate WIMP-nucleon effective interactions involving the nucleon or WIMP spin, including, in addition to standard axial spin-dependent (SD) scattering, various couplings among vector and axial currents, magnetic and electric dipole moments, and tensor interactions. The data set corresponding to a total exposure of 54-ton-days is reanalyzed to determine constraints as a function of the WIMP mass and isospin coupling. We obtain WIMP-nucleon cross section bounds of $\rm 1.6 \times 10^{-41} cm^2$ and $\rm 9.0 \times 10^{-42} cm^2$ ($90\%$ c.l.) for neutron-only SD and tensor coupling, respectively, for a mass $M_\mathrm{WIMP} \sim {\rm 40~GeV}/c^2$. The SD limits are the best currently available for $M_\mathrm{WIMP} > {\rm 40~GeV}/c^2$. We show that PandaX-II has reached a sensitivity sufficient to probe a variety of other candidate spin-dependent interactions at the weak scale.
△ Less
Submitted 31 March, 2019; v1 submitted 5 July, 2018;
originally announced July 2018.
-
Constraining Dark Matter Models with a Light Mediator from PandaX-II Experiment
Authors:
Xiangxiang Ren,
Li Zhao,
Abdusalam Abdukerim,
Xun Chen,
Yunhua Chen,
Xiangyi Cui,
Deqing Fang,
Changbo Fu,
Karl Giboni,
Franco Giuliani,
Linhui Gu,
Xuyuan Guo,
Ke Han,
Changda He,
Di Huang,
Shengming He,
Xingtao Huang,
Zhou Huang,
Xiangdong Ji,
Yonglin Ju,
Yao Li,
Heng Lin,
Huaxuan Liu,
Jianglai Liu,
Yugang Ma
, et al. (22 additional authors not shown)
Abstract:
We search for nuclear recoil signals of dark matter models with a light mediator in PandaX-II, a direct detection experiment in China **** underground Laboratory. Using data collected in 2016 and 2017 runs, corresponding to a total exposure of 54 ton day, we set upper limits on the zero-momentum dark matter-nucleon cross section. These limits have a strong dependence on the mediator mass when i…
▽ More
We search for nuclear recoil signals of dark matter models with a light mediator in PandaX-II, a direct detection experiment in China **** underground Laboratory. Using data collected in 2016 and 2017 runs, corresponding to a total exposure of 54 ton day, we set upper limits on the zero-momentum dark matter-nucleon cross section. These limits have a strong dependence on the mediator mass when it is comparable to or below the typical momentum transfer. We apply our results to constrain self-interacting dark matter models with a light mediator mixing with standard model particles, and set strong limits on the model parameter space for the dark matter mass ranging from $5~{\rm GeV}$ to $10~{\rm TeV}$.
△ Less
Submitted 13 June, 2018; v1 submitted 19 February, 2018;
originally announced February 2018.
-
Dark Matter Results From 54-Ton-Day Exposure of PandaX-II Experiment
Authors:
PandaX-II Collaboration,
:,
Xiangyi Cui,
Abdusalam Abdukerim,
Wei Chen,
Xun Chen,
Yunhua Chen,
Binbin Dong,
Deqing Fang,
Changbo Fu,
Karl Giboni,
Franco Giuliani,
Linhui Gu,
Yikun Gu,
Xuyuan Guo,
Zhifan Guo,
Ke Han,
Changda He,
Di Huang,
Shengming He,
Xingtao Huang,
Zhou Huang,
Xiangdong Ji,
Yonglin Ju,
Shaoli Li
, et al. (33 additional authors not shown)
Abstract:
We report a new search of weakly interacting massive particles (WIMPs) using the combined low background data sets in 2016 and 2017 from the PandaX-II experiment in China. The latest data set contains a new exposure of 77.1 live day, with the background reduced to a level of 0.8$\times10^{-3}$ evt/kg/day, improved by a factor of 2.5 in comparison to the previous run in 2016. No excess events were…
▽ More
We report a new search of weakly interacting massive particles (WIMPs) using the combined low background data sets in 2016 and 2017 from the PandaX-II experiment in China. The latest data set contains a new exposure of 77.1 live day, with the background reduced to a level of 0.8$\times10^{-3}$ evt/kg/day, improved by a factor of 2.5 in comparison to the previous run in 2016. No excess events were found above the expected background. With a total exposure of 5.4$\times10^4$ kg day, the most stringent upper limit on spin-independent WIMP-nucleon cross section was set for a WIMP with mass larger than 100 GeV/c$^2$, with the lowest exclusion at 8.6$\times10^{-47}$ cm$^2$ at 40 GeV/c$^2$.
△ Less
Submitted 21 September, 2017; v1 submitted 23 August, 2017;
originally announced August 2017.
-
Exploring the dark matter inelastic frontier with 79.6 days of PandaX-II data
Authors:
PandaX-II Collaboration,
:,
Xun Chen,
Abdusalam Abdukerim,
Wei Chen,
Yunhua Chen,
Xiangyi Cui,
Deqing Fang,
Changbo Fu,
Karl Giboni,
Franco Giuliani,
Xuyuan Guo,
Zhifan Guo,
Ke Han,
Shengming He,
Xingtao Huang,
Xiangdong Ji,
Yonglin Ju,
Shaoli Li,
Heng Lin,
Huaxuan Liu,
Jianglai Liu,
Yugang Ma,
Yajun Mao,
**hua Ning
, et al. (24 additional authors not shown)
Abstract:
We report here the results of searching for inelastic scattering of dark matter (initial and final state dark matter particles differ by a small mass splitting) with nucleon with the first 79.6-day of PandaX-II data (Run 9). We set the upper limits for the spin independent WIMP-nucleon scattering cross section up to a mass splitting of 300 keV/c$^2$ at two benchmark dark matter masses of 1 and 10…
▽ More
We report here the results of searching for inelastic scattering of dark matter (initial and final state dark matter particles differ by a small mass splitting) with nucleon with the first 79.6-day of PandaX-II data (Run 9). We set the upper limits for the spin independent WIMP-nucleon scattering cross section up to a mass splitting of 300 keV/c$^2$ at two benchmark dark matter masses of 1 and 10 TeV/c$^2$.
△ Less
Submitted 3 October, 2017; v1 submitted 19 August, 2017;
originally announced August 2017.