Fluorescence Imaging of Individual Ions and Molecules in Pressurized Noble Gases for Barium Tagging in $^{136}$Xe
Authors:
NEXT Collaboration,
N. Byrnes,
E. Dey,
F. W. Foss,
B. J. P. Jones,
R. Madigan,
A. McDonald,
R. L. Miller,
K. E. Navarro,
L. R. Norman,
D. R. Nygren,
C. Adams,
H. Almazán,
V. Álvarez,
B. Aparicio,
A. I. Aranburu,
L. Arazi,
I. J. Arnquist,
F. Auria-Luna,
S. Ayet,
C. D. R. Azevedo,
J. E. Barcelon,
K. Bailey,
F. Ballester,
M. del Barrio-Torregrosa
, et al. (90 additional authors not shown)
Abstract:
The imaging of individual Ba$^{2+}$ ions in high pressure xenon gas is one possible way to attain background-free sensitivity to neutrinoless double beta decay and hence establish the Majorana nature of the neutrino. In this paper we demonstrate selective single Ba$^{2+}$ ion imaging inside a high-pressure xenon gas environment. Ba$^{2+}$ ions chelated with molecular chemosensors are resolved at t…
▽ More
The imaging of individual Ba$^{2+}$ ions in high pressure xenon gas is one possible way to attain background-free sensitivity to neutrinoless double beta decay and hence establish the Majorana nature of the neutrino. In this paper we demonstrate selective single Ba$^{2+}$ ion imaging inside a high-pressure xenon gas environment. Ba$^{2+}$ ions chelated with molecular chemosensors are resolved at the gas-solid interface using a diffraction-limited imaging system with scan area of 1$\times$1~cm$^2$ located inside 10~bar of xenon gas. This new form of microscopy represents an important enabling step in the development of barium tagging for neutrinoless double beta decay searches in $^{136}$Xe, as well as a new tool for studying the photophysics of fluorescent molecules and chemosensors at the solid-gas interface.
△ Less
Submitted 20 May, 2024;
originally announced June 2024.
-
Measurement of Energy Resolution with the NEXT-White Silicon Photomultipliers
Authors:
T. Contreras,
B. Palmeiro,
H. Almazán,
A. Para,
G. Martínez-Lema,
R. Guenette,
C. Adams,
V. Álvarez,
B. Aparicio,
A. I. Aranburu,
L. Arazi,
I. J. Arnquist,
F. Auria-Luna,
S. Ayet,
C. D. R. Azevedo,
K. Bailey,
F. Ballester,
M. del Barrio-Torregrosa,
A. Bayo,
J. M. Benlloch-Rodríguez,
F. I. G. M. Borges,
A. Brodolin,
N. Byrnes,
S. Cárcel,
A. Castillo
, et al. (85 additional authors not shown)
Abstract:
The NEXT-White detector, a high-pressure gaseous xenon time projection chamber, demonstrated the excellence of this technology for future neutrinoless double beta decay searches using photomultiplier tubes (PMTs) to measure energy and silicon photomultipliers (SiPMs) to extract topology information. This analysis uses $^{83m}\text{Kr}$ data from the NEXT-White detector to measure and understand th…
▽ More
The NEXT-White detector, a high-pressure gaseous xenon time projection chamber, demonstrated the excellence of this technology for future neutrinoless double beta decay searches using photomultiplier tubes (PMTs) to measure energy and silicon photomultipliers (SiPMs) to extract topology information. This analysis uses $^{83m}\text{Kr}$ data from the NEXT-White detector to measure and understand the energy resolution that can be obtained with the SiPMs, rather than with PMTs. The energy resolution obtained of (10.9 $\pm$ 0.6) $\%$, full-width half-maximum, is slightly larger than predicted based on the photon statistics resulting from very low light detection coverage of the SiPM plane in the NEXT-White detector. The difference in the predicted and measured resolution is attributed to poor corrections, which are expected to be improved with larger statistics. Furthermore, the noise of the SiPMs is shown to not be a dominant factor in the energy resolution and may be negligible when noise subtraction is applied appropriately, for high-energy events or larger SiPM coverage detectors. These results, which are extrapolated to estimate the response of large coverage SiPM planes, are promising for the development of future, SiPM-only, readout planes that can offer imaging and achieve similar energy resolution to that previously demonstrated with PMTs.
△ Less
Submitted 30 May, 2024;
originally announced May 2024.
-
Demonstration of Event Position Reconstruction based on Diffusion in the NEXT-White Detector
Authors:
J. Haefner,
K. E. Navarro,
R. Guenette,
B. J. P. Jones,
A. Tripathi,
C. Adams,
H. Almazán,
V. Álvarez,
B. Aparicio,
A. I. Aranburu,
L. Arazi,
I. J. Arnquist,
F. Auria-Luna,
S. Ayet,
C. D. R. Azevedo,
K. Bailey,
F. Ballester,
M. del Barrio-Torregrosa,
A. Bayo,
J. M. BenllochRodríguez,
F. I. G. M. Borges,
A. Brodolin,
N. Byrnes,
S. Cárcel,
J. V. Carrión
, et al. (86 additional authors not shown)
Abstract:
Noble element time projection chambers are a leading technology for rare event detection in physics, such as for dark matter and neutrinoless double beta decay searches. Time projection chambers typically assign event position in the drift direction using the relative timing of prompt scintillation and delayed charge collection signals, allowing for reconstruction of an absolute position in the dr…
▽ More
Noble element time projection chambers are a leading technology for rare event detection in physics, such as for dark matter and neutrinoless double beta decay searches. Time projection chambers typically assign event position in the drift direction using the relative timing of prompt scintillation and delayed charge collection signals, allowing for reconstruction of an absolute position in the drift direction. In this paper, alternate methods for assigning event drift distance via quantification of electron diffusion in a pure high pressure xenon gas time projection chamber are explored. Data from the NEXT-White detector demonstrate the ability to achieve good position assignment accuracy for both high- and low-energy events. Using point-like energy deposits from $^{83\mathrm{m}}$Kr calibration electron captures ($E\sim45$keV), the position of origin of low-energy events is determined to $2~$cm precision with bias $< 1$mm. A convolutional neural network approach is then used to quantify diffusion for longer tracks (E$\geq$1.5MeV), yielding a precision of 3cm on the event barycenter. The precision achieved with these methods indicates the feasibility energy calibrations of better than 1% FWHM at Q$_{ββ}$ in pure xenon, as well as the potential for event fiducialization in large future detectors using an alternate method that does not rely on primary scintillation.
△ Less
Submitted 6 November, 2023;
originally announced November 2023.
-
Demonstration of neutrinoless double beta decay searches in gaseous xenon with NEXT
Authors:
NEXT Collaboration,
P. Novella,
M. Sorel,
A. Usón,
C. Adams,
H. Almazán,
V. Álvarez,
B. Aparicio,
A. I. Aranburu,
L. Arazi,
I. J. Arnquist,
F. Auria-Luna,
S. Ayet,
C. D. R. Azevedo,
K. Bailey,
F. Ballester,
M. del Barrio-Torregrosa,
A. Bayo,
J. M. Benlloch-Rodríguez,
F. I. G. M. Borges,
S. Bounasser,
N. Byrnes,
S. Cárcel,
J. V. Carrión,
S. Cebrián
, et al. (90 additional authors not shown)
Abstract:
The NEXT experiment aims at the sensitive search of the neutrinoless double beta decay in $^{136}$Xe, using high-pressure gas electroluminescent time projection chambers. The NEXT-White detector is the first radiopure demonstrator of this technology, operated in the Laboratorio Subterráneo de Canfranc. Achieving an energy resolution of 1% FWHM at 2.6 MeV and further background rejection by means o…
▽ More
The NEXT experiment aims at the sensitive search of the neutrinoless double beta decay in $^{136}$Xe, using high-pressure gas electroluminescent time projection chambers. The NEXT-White detector is the first radiopure demonstrator of this technology, operated in the Laboratorio Subterráneo de Canfranc. Achieving an energy resolution of 1% FWHM at 2.6 MeV and further background rejection by means of the topology of the reconstructed tracks, NEXT-White has been exploited beyond its original goals in order to perform a neutrinoless double beta decay search. The analysis considers the combination of 271.6 days of $^{136}$Xe-enriched data and 208.9 days of $^{136}$Xe-depleted data. A detailed background modeling and measurement has been developed, ensuring the time stability of the radiogenic and cosmogenic contributions across both data samples. Limits to the neutrinoless mode are obtained in two alternative analyses: a background-model-dependent approach and a novel direct background-subtraction technique, offering results with small dependence on the background model assumptions. With a fiducial mass of only 3.50$\pm$0.01 kg of $^{136}$Xe-enriched xenon, 90% C.L. lower limits to the neutrinoless double beta decay are found in the T$_{1/2}^{0ν}>5.5\times10^{23}-1.3\times10^{24}$ yr range, depending on the method. The presented techniques stand as a proof-of-concept for the searches to be implemented with larger NEXT detectors.
△ Less
Submitted 22 September, 2023; v1 submitted 16 May, 2023;
originally announced May 2023.
-
A Compact Dication Source for Ba$^{2+}$ Tagging and Heavy Metal Ion Sensor Development
Authors:
K. E. Navarro,
B. J. P. Jones,
J. Baeza-Rubio,
M. Boyd,
A. A. Denisenko,
F. W. Foss,
S. Giri,
R. Miller,
D. R. Nygren,
M. R. Tiscareno,
F. J. Samaniego,
K. Stogsdill,
C. Adams,
H. Almazán,
V. Álvarez,
B. Aparicio,
A. I. Aranburu,
L. Arazi,
I. J. Arnquist,
S. Ayet,
C. D. R. Azevedo,
K. Bailey,
F. Ballester,
J. M. Benlloch-Rodríguez,
F. I. G. M. Borges
, et al. (85 additional authors not shown)
Abstract:
We present a tunable metal ion beam that delivers controllable ion currents in the picoamp range for testing of dry-phase ion sensors. Ion beams are formed by sequential atomic evaporation and single or multiple electron impact ionization, followed by acceleration into a sensing region. Controllability of the ionic charge state is achieved through tuning of electrode potentials that influence the…
▽ More
We present a tunable metal ion beam that delivers controllable ion currents in the picoamp range for testing of dry-phase ion sensors. Ion beams are formed by sequential atomic evaporation and single or multiple electron impact ionization, followed by acceleration into a sensing region. Controllability of the ionic charge state is achieved through tuning of electrode potentials that influence the retention time in the ionization region. Barium, lead, and cobalt samples have been used to test the system, with ion currents identified and quantified using a quadrupole mass analyzer. Realization of a clean $\mathrm{Ba^{2+}}$ ion beam within a bench-top system represents an important technical advance toward the development and characterization of barium tagging systems for neutrinoless double beta decay searches in xenon gas. This system also provides a testbed for investigation of novel ion sensing methodologies for environmental assay applications, with dication beams of Pb$^{2+}$ and Cd$^{2+}$ also demonstrated for this purpose.
△ Less
Submitted 2 March, 2023;
originally announced March 2023.
-
Diffusion of muonic hydrogen in hydrogen gas and the measurement of the 1$s$ hyperfine splitting of muonic hydrogen
Authors:
J. Nuber,
A. Adamczak,
M. Abdou Ahmed,
L. Affolter,
F. D. Amaro,
P. Amaro,
P. Carvalho,
Y. -H. Chang,
T. -L. Chen,
W. -L. Chen,
L. M. P. Fernandes,
M. Ferro,
D. Goeldi,
T. Graf,
M. Guerra,
T. W. Hänsch,
C. A. O. Henriques,
M. Hildebrandt,
P. Indelicato,
O. Kara,
K. Kirch,
A. Knecht,
F. Kottmann,
Y. -W. Liu,
J. Machado
, et al. (24 additional authors not shown)
Abstract:
The CREMA collaboration is pursuing a measurement of the ground-state hyperfine splitting (HFS) in muonic hydrogen ($μ$p) with 1 ppm accuracy by means of pulsed laser spectroscopy. In the proposed experiment, the $μ$p atom is excited by a laser pulse from the singlet to the triplet hyperfine sub-levels, and is quenched back to the singlet state by an inelastic collision with a H$_2$ molecule. The…
▽ More
The CREMA collaboration is pursuing a measurement of the ground-state hyperfine splitting (HFS) in muonic hydrogen ($μ$p) with 1 ppm accuracy by means of pulsed laser spectroscopy. In the proposed experiment, the $μ$p atom is excited by a laser pulse from the singlet to the triplet hyperfine sub-levels, and is quenched back to the singlet state by an inelastic collision with a H$_2$ molecule. The resulting increase of kinetic energy after this cycle modifies the $μ$p atom diffusion in the hydrogen gas and the arrival time of the $μ$p atoms at the target walls. This laser-induced modification of the arrival times is used to expose the atomic transition. In this paper we present the simulation of the $μ$p diffusion in the H$_2$ gas which is at the core of the experimental scheme. These simulations have been implemented with the Geant4 framework by introducing various low-energy processes including the motion of the H$_2$ molecules, i.e. the effects related with the hydrogen target temperature. The simulations have been used to optimize the hydrogen target parameters (pressure, temperatures and thickness) and to estimate signal and background rates. These rates allow to estimate the maximum time needed to find the resonance and the statistical accuracy of the spectroscopy experiment.
△ Less
Submitted 24 May, 2023; v1 submitted 15 November, 2022;
originally announced November 2022.
-
Reflectance and fluorescence characteristics of PTFE coated with TPB at visible, UV, and VUV as a function of thickness
Authors:
J. Haefner,
A. Fahs,
J. Ho,
C. Stanford,
R. Guenette,
C. Adams,
H. Almazán,
V. Álvarez,
B. Aparicio,
A. I. Aranburu,
L. Arazi,
I. J. Arnquist,
F. Auria-Luna,
S. Ayet,
C. D. R. Azevedo,
K. Bailey,
F. Ballester,
J. M. Benlloch-Rodríguez,
F. I. G. M. Borges,
S. Bounasser,
N. Byrnes,
S. Cárcel,
J. V. Carrión,
S. Cebrián,
E. Church
, et al. (78 additional authors not shown)
Abstract:
Polytetrafluoroethylene (PTFE) is an excellent diffuse reflector widely used in light collection systems for particle physics experiments. In noble element systems, it is often coated with tetraphenyl butadiene (TPB) to allow detection of vacuum ultraviolet scintillation light. In this work this dependence is investigated for PTFE coated with TPB in air for light of wavelengths of 200~nm, 260~nm,…
▽ More
Polytetrafluoroethylene (PTFE) is an excellent diffuse reflector widely used in light collection systems for particle physics experiments. In noble element systems, it is often coated with tetraphenyl butadiene (TPB) to allow detection of vacuum ultraviolet scintillation light. In this work this dependence is investigated for PTFE coated with TPB in air for light of wavelengths of 200~nm, 260~nm, and 450~nm. The results show that TPB-coated PTFE has a reflectance of approximately 92\% for thicknesses ranging from 5~mm to 10~mm at 450~nm, with negligible variation as a function of thickness within this range. A cross-check of these results using an argon chamber supports the conclusion that the change in thickness from 5~mm to 10~mm does not affect significantly the light response at 128~nm. Our results indicate that pieces of TPB-coated PTFE thinner than the typical 10~mm can be used in particle physics detectors without compromising the light signal.
△ Less
Submitted 10 January, 2023; v1 submitted 9 November, 2022;
originally announced November 2022.
-
Recoil imaging for directional detection of dark matter, neutrinos, and physics beyond the Standard Model
Authors:
C. A. J. O'Hare,
D. Loomba,
K. Altenmüller,
H. Álvarez-Pol,
F. D. Amaro,
H. M. Araújo,
D. Aristizabal Sierra,
J. Asaadi,
D. Attié,
S. Aune,
C. Awe,
Y. Ayyad,
E. Baracchini,
P. Barbeau,
J. B. R. Battat,
N. F. Bell,
B. Biasuzzi,
L. J. Bignell,
C. Boehm,
I. Bolognino,
F. M. Brunbauer,
M. Caamaño,
C. Cabo,
D. Caratelli,
J. M. Carmona
, et al. (142 additional authors not shown)
Abstract:
Recoil imaging entails the detection of spatially resolved ionization tracks generated by particle interactions. This is a highly sought-after capability in many classes of detector, with broad applications across particle and astroparticle physics. However, at low energies, where ionization signatures are small in size, recoil imaging only seems to be a practical goal for micro-pattern gas detect…
▽ More
Recoil imaging entails the detection of spatially resolved ionization tracks generated by particle interactions. This is a highly sought-after capability in many classes of detector, with broad applications across particle and astroparticle physics. However, at low energies, where ionization signatures are small in size, recoil imaging only seems to be a practical goal for micro-pattern gas detectors. This white paper outlines the physics case for recoil imaging, and puts forward a decadal plan to advance towards the directional detection of low-energy recoils with sensitivity and resolution close to fundamental performance limits. The science case covered includes: the discovery of dark matter into the neutrino fog, directional detection of sub-MeV solar neutrinos, the precision study of coherent-elastic neutrino-nucleus scattering, the detection of solar axions, the measurement of the Migdal effect, X-ray polarimetry, and several other applied physics goals. We also outline the R&D programs necessary to test concepts that are crucial to advance detector performance towards their fundamental limit: single primary electron sensitivity with full 3D spatial resolution at the $\sim$100 micron-scale. These advancements include: the use of negative ion drift, electron counting with high-definition electronic readout, time projection chambers with optical readout, and the possibility for nuclear recoil tracking in high-density gases such as argon. We also discuss the readout and electronics systems needed to scale-up such detectors to the ton-scale and beyond.
△ Less
Submitted 17 July, 2022; v1 submitted 11 March, 2022;
originally announced March 2022.
-
A Next-Generation Liquid Xenon Observatory for Dark Matter and Neutrino Physics
Authors:
J. Aalbers,
K. Abe,
V. Aerne,
F. Agostini,
S. Ahmed Maouloud,
D. S. Akerib,
D. Yu. Akimov,
J. Akshat,
A. K. Al Musalhi,
F. Alder,
S. K. Alsum,
L. Althueser,
C. S. Amarasinghe,
F. D. Amaro,
A. Ames,
T. J. Anderson,
B. Andrieu,
N. Angelides,
E. Angelino,
J. Angevaare,
V. C. Antochi,
D. Antón Martin,
B. Antunovic,
E. Aprile,
H. M. Araújo
, et al. (572 additional authors not shown)
Abstract:
The nature of dark matter and properties of neutrinos are among the most pressing issues in contemporary particle physics. The dual-phase xenon time-projection chamber is the leading technology to cover the available parameter space for Weakly Interacting Massive Particles (WIMPs), while featuring extensive sensitivity to many alternative dark matter candidates. These detectors can also study neut…
▽ More
The nature of dark matter and properties of neutrinos are among the most pressing issues in contemporary particle physics. The dual-phase xenon time-projection chamber is the leading technology to cover the available parameter space for Weakly Interacting Massive Particles (WIMPs), while featuring extensive sensitivity to many alternative dark matter candidates. These detectors can also study neutrinos through neutrinoless double-beta decay and through a variety of astrophysical sources. A next-generation xenon-based detector will therefore be a true multi-purpose observatory to significantly advance particle physics, nuclear physics, astrophysics, solar physics, and cosmology. This review article presents the science cases for such a detector.
△ Less
Submitted 4 March, 2022;
originally announced March 2022.
-
The CYGNO Experiment
Authors:
Fernando Domingues Amaro,
Elisabetta Baracchini,
Luigi Benussi,
Stefano Bianco,
Cesidio Capoccia,
Michele Caponero,
Danilo Santos Cardoso,
Gianluca Cavoto,
André Cortez,
Igor Abritta Costa,
Rita Joanna da Cruz Roque,
Emiliano Dané,
Giorgio Dho,
Flaminia Di Giambattista,
Emanuele Di Marco,
Giovanni Grilli di Cortona,
Giulia D'Imperio,
Francesco Iacoangeli,
Herman Pessoa Lima Júnior,
Guilherme Sebastiao Pinheiro Lopes,
Amaro da Silva Lopes Júnior,
Giovanni Maccarrone,
Rui Daniel Passos Mano,
Michela Marafini,
Robert Renz Marcelo Gregorio
, et al. (25 additional authors not shown)
Abstract:
The search for a novel technology able to detect and reconstruct nuclear and electron recoil events with the energy of a few keV has become more and more important now that large regions of high-mass dark matter (DM) candidates have been excluded. Moreover, a detector sensitive to incoming particle direction will be crucial in the case of DM discovery to open the possibility of studying its proper…
▽ More
The search for a novel technology able to detect and reconstruct nuclear and electron recoil events with the energy of a few keV has become more and more important now that large regions of high-mass dark matter (DM) candidates have been excluded. Moreover, a detector sensitive to incoming particle direction will be crucial in the case of DM discovery to open the possibility of studying its properties. Gaseous time projection chambers (TPC) with optical readout are very promising detectors combining the detailed event information provided by the TPC technique with the high sensitivity and granularity of latest-generation scientific light sensors. The CYGNO experiment (a CYGNus module with Optical readout) aims to exploit the optical readout approach of multiple-GEM structures in large volume TPCs for the study of rare events as interactions of low-mass DM or solar neutrinos. The combined use of high-granularity sCMOS cameras and fast light sensors allows the reconstruction of the 3D direction of the tracks, offering good energy resolution and very high sensitivity in the few keV energy range, together with a very good particle identification useful for distinguishing nuclear recoils from electronic recoils. This experiment is part of the CYGNUS proto-collaboration, which aims at constructing a network of underground observatories for directional DM search. A one cubic meter demonstrator is expected to be built in 2022/23 aiming at a larger scale apparatus (30 m$^3$--100 m$^3$) at a later stage.
△ Less
Submitted 11 February, 2022;
originally announced February 2022.
-
Ba$^{2+}$ ion trap** by organic submonolayer: towards an ultra-low background neutrinoless double beta decay detector
Authors:
P. Herrero-Gómez,
J. P. Calupitan,
M. Ilyn,
A. Berdonces-Layunta,
T. Wang,
D. G. de Oteyza,
M. Corso,
R. González-Moreno,
I. Rivilla,
B. Aparicio,
A. I. Aranburu,
Z. Freixa,
F. Monrabal,
F. P. Cossío,
J. J. Gómez-Cadenas,
C. Rogero,
C. Adams,
H. Almazán,
V. Alvarez,
L. Arazi,
I. J. Arnquist,
S. Ayet,
C. D. R. Azevedo,
K. Bailey,
F. Ballester
, et al. (90 additional authors not shown)
Abstract:
If neutrinos are their own antiparticles, the otherwise-forbidden nuclear reaction known as neutrinoless double beta decay ($ββ0ν$) can occur, with a characteristic lifetime which is expected to be very long, making the suppression of backgrounds a daunting task. It has been shown that detecting (``tagging'') the Ba$^{+2}$ dication produced in the double beta decay…
▽ More
If neutrinos are their own antiparticles, the otherwise-forbidden nuclear reaction known as neutrinoless double beta decay ($ββ0ν$) can occur, with a characteristic lifetime which is expected to be very long, making the suppression of backgrounds a daunting task. It has been shown that detecting (``tagging'') the Ba$^{+2}$ dication produced in the double beta decay ${}^{136}\mathrm{Xe} \rightarrow {}^{136}$Ba$^{+2}+ 2 e + (2 ν)$ in a high pressure gas experiment, could lead to a virtually background free experiment. To identify these \Bapp, chemical sensors are being explored as a key tool by the NEXT collaboration . Although used in many fields, the application of such chemosensors to the field of particle physics is totally novel and requires experimental demonstration of their suitability in the ultra-dry environment of a xenon gas chamber. Here we use a combination of complementary surface science techniques to unambiguously show that Ba$^{+2}$ ions can be trapped (chelated) in vacuum by an organic molecule, the so-called fluorescent bicolour indicator (FBI) (one of the chemosensors developed by NEXT), immobilized on a surface. We unravel the ion capture mechanism once the molecules are immobilised on Au(111) surface and explain the origin of the emission fluorescence shift associated to the trap** of different ions. Moreover, we prove that chelation also takes place on a technologically relevant substrate, as such, demonstrating the feasibility of using FBI indicators as building blocks of a Ba$^{+2}$ detector.
△ Less
Submitted 22 January, 2022;
originally announced January 2022.
-
Measurement of the ${}^{136}$Xe two-neutrino double beta decay half-life via direct background subtraction in NEXT
Authors:
NEXT Collaboration,
P. Novella,
M. Sorel,
A. Usón,
C. Adams,
H. Almazán,
V. Álvarez,
B. Aparicio,
A. I. Aranburu,
L. Arazi,
I. J. Arnquist,
S. Ayet,
C. D. R. Azevedo,
K. Bailey,
F. Ballester,
J. M. Benlloch-Rodríguez,
F. I. G. M. Borges,
S. Bounasser,
N. Byrnes,
S. Cárcel,
J. V. Carrión,
S. Cebrián,
E. Church,
C. A. N. Conde,
T. Contreras
, et al. (85 additional authors not shown)
Abstract:
We report a measurement of the half-life of the ${}^{136}$Xe two-neutrino double beta decay performed with a novel direct background subtraction technique. The analysis relies on the data collected with the NEXT-White detector operated with ${}^{136}$Xe-enriched and ${}^{136}$Xe-depleted xenon, as well as on the topology of double-electron tracks. With a fiducial mass of only 3.5 kg of Xe, a half-…
▽ More
We report a measurement of the half-life of the ${}^{136}$Xe two-neutrino double beta decay performed with a novel direct background subtraction technique. The analysis relies on the data collected with the NEXT-White detector operated with ${}^{136}$Xe-enriched and ${}^{136}$Xe-depleted xenon, as well as on the topology of double-electron tracks. With a fiducial mass of only 3.5 kg of Xe, a half-life of $2.34^{+0.80}_{-0.46}\textrm{(stat)}^{+0.30}_{-0.17}\textrm{(sys)}\times10^{21}~\textrm{yr}$ is derived from the background-subtracted energy spectrum. The presented technique demonstrates the feasibility of unique background-model-independent neutrinoless double beta decay searches.
△ Less
Submitted 11 May, 2022; v1 submitted 22 November, 2021;
originally announced November 2021.
-
Boosting background suppression in the NEXT experiment through Richardson-Lucy deconvolution
Authors:
A. Simón,
Y. Ifergan,
A. B. Redwine,
R. Weiss-Babai,
L. Arazi,
C. Adams,
H. Almazán,
V. Álvarez,
B. Aparicio,
A. I. Aranburu,
I. J. Arnquist,
C. D. R Azevedo,
K. Bailey,
F. Ballester,
J. M. Benlloch-Rodríguez,
F. I. G. M. Borges,
N. Byrnes,
S. Cárcel,
J. V. Carrión,
S. Cebrián,
E. Church,
C. A. N. Conde,
T. Contreras,
F. P. Cossío,
A. A. Denisenko
, et al. (78 additional authors not shown)
Abstract:
Next-generation neutrinoless double beta decay experiments aim for half-life sensitivities of ~$10^{27}$ yr, requiring suppressing backgrounds to <1 count/tonne/yr. For this, any extra background rejection handle, beyond excellent energy resolution and the use of extremely radiopure materials, is of utmost importance. The NEXT experiment exploits differences in the spatial ionization patterns of d…
▽ More
Next-generation neutrinoless double beta decay experiments aim for half-life sensitivities of ~$10^{27}$ yr, requiring suppressing backgrounds to <1 count/tonne/yr. For this, any extra background rejection handle, beyond excellent energy resolution and the use of extremely radiopure materials, is of utmost importance. The NEXT experiment exploits differences in the spatial ionization patterns of double beta decay and single-electron events to discriminate signal from background. While the former display two Bragg peak dense ionization regions at the opposite ends of the track, the latter typically have only one such feature. Thus, comparing the energies at the track extremes provides an additional rejection tool. The unique combination of the topology-based background discrimination and excellent energy resolution (1% FWHM at the Q-value of the decay) is the distinguishing feature of NEXT. Previous studies demonstrated a topological background rejection factor of ~5 when reconstructing electron-positron pairs in the $^{208}$Tl 1.6 MeV double escape peak (with Compton events as background), recorded in the NEXT-White demonstrator at the Laboratorio Subterráneo de Canfranc, with 72% signal efficiency. This was recently improved through the use of a deep convolutional neural network to yield a background rejection factor of ~10 with 65% signal efficiency. Here, we present a new reconstruction method, based on the Richardson-Lucy deconvolution algorithm, which allows reversing the blurring induced by electron diffusion and electroluminescence light production in the NEXT TPC. The new method yields highly refined 3D images of reconstructed events, and, as a result, significantly improves the topological background discrimination. When applied to real-data 1.6 MeV $e^-e^+$ pairs, it leads to a background rejection factor of 27 at 57% signal efficiency.
△ Less
Submitted 21 May, 2021; v1 submitted 23 February, 2021;
originally announced February 2021.
-
Electroluminescence yield in pure krypton
Authors:
R. D. P. Mano,
C. A. O. Henriques,
F. D. Amaro,
C. M. B. Monteiro
Abstract:
The krypton electroluminescence yield was studied, at room temperature, as a function of electric field in the gas scintillation gap. A large area avalanche photodiode has been used to allow the simultaneous detection of the electroluminescence pulses as well as the direct interaction of x-rays, the latter being used as a reference for the calculation of the number of charge carriers produced by t…
▽ More
The krypton electroluminescence yield was studied, at room temperature, as a function of electric field in the gas scintillation gap. A large area avalanche photodiode has been used to allow the simultaneous detection of the electroluminescence pulses as well as the direct interaction of x-rays, the latter being used as a reference for the calculation of the number of charge carriers produced by the electroluminescence pulses and, thus, the determination of the number of photons im**ing the photodiode. An amplification parameter of 113 photons per kV per drifting electron and a scintillation threshold of 2.7 Td ( 0.7 kV/cm/bar at 293 K ) was obtained, in good agreement with the simulation data reported in the literature. On the other hand, the ionisation threshold in krypton was found to be around 13.5 Td (3.4 kV/cm/bar), less than what had been obtained by the most recent simulation work-package. The krypton amplification parameter is about 80% and 140% of those measured for xenon and argon, respectively. The electroluminescence yield in krypton is of great importance for modeling krypton-based double-phase or high-pressure gas detectors, which may be used in future rare event detection experiments.
△ Less
Submitted 29 January, 2021;
originally announced February 2021.
-
Demonstration of background rejection using deep convolutional neural networks in the NEXT experiment
Authors:
NEXT Collaboration,
M. Kekic,
C. Adams,
K. Woodruff,
J. Renner,
E. Church,
M. Del Tutto,
J. A. Hernando Morata,
J. J. Gomez-Cadenas,
V. Alvarez,
L. Arazi,
I. J. Arnquist,
C. D. R Azevedo,
K. Bailey,
F. Ballester,
J. M. Benlloch-Rodriguez,
F. I. G. M. Borges,
N. Byrnes,
S. Carcel,
J. V. Carrion,
S. Cebrian,
C. A. N. Conde,
T. Contreras,
G. Diaz,
J. Diaz
, et al. (66 additional authors not shown)
Abstract:
Convolutional neural networks (CNNs) are widely used state-of-the-art computer vision tools that are becoming increasingly popular in high energy physics. In this paper, we attempt to understand the potential of CNNs for event classification in the NEXT experiment, which will search for neutrinoless double-beta decay in $^{136}$Xe. To do so, we demonstrate the usage of CNNs for the identification…
▽ More
Convolutional neural networks (CNNs) are widely used state-of-the-art computer vision tools that are becoming increasingly popular in high energy physics. In this paper, we attempt to understand the potential of CNNs for event classification in the NEXT experiment, which will search for neutrinoless double-beta decay in $^{136}$Xe. To do so, we demonstrate the usage of CNNs for the identification of electron-positron pair production events, which exhibit a topology similar to that of a neutrinoless double-beta decay event. These events were produced in the NEXT-White high-pressure xenon TPC using 2.6-MeV gamma rays from a $^{228}$Th calibration source. We train a network on Monte Carlo-simulated events and show that, by applying on-the-fly data augmentation, the network can be made robust against differences between simulation and data. The use of CNNs offer significant improvement in signal efficiency/background rejection when compared to previous non-CNN-based analyses.
△ Less
Submitted 30 January, 2021; v1 submitted 22 September, 2020;
originally announced September 2020.
-
Sensitivity of the NEXT experiment to Xe-124 double electron capture
Authors:
G. Martínez-Lema,
M. Martínez-Vara,
M. Sorel,
C. Adams,
V. Alvarez,
L. Arazi,
I. J. Arnquist,
C. D. R Azevedo,
K. Bailey,
F. Ballester,
J. M. Benlloch-Rodríguez,
F. I. G. M. Borges,
N. Byrnes,
S. Cárcel,
J. V. Carrión,
S. Cebrián,
E. Church,
C. A. N. Conde,
T. Contreras,
G. Díaz,
J. Díaz,
M. Diesburg,
J. Escada,
R. Esteve,
R. Felkai
, et al. (66 additional authors not shown)
Abstract:
Double electron capture by proton-rich nuclei is a second-order nuclear process analogous to double beta decay. Despite their similarities, the decay signature is quite different, potentially providing a new channel to measure the hypothesized neutrinoless mode of these decays. The Standard-Model-allowed two-neutrino double electron capture ($2νECEC$) has been predicted for a number of isotopes, b…
▽ More
Double electron capture by proton-rich nuclei is a second-order nuclear process analogous to double beta decay. Despite their similarities, the decay signature is quite different, potentially providing a new channel to measure the hypothesized neutrinoless mode of these decays. The Standard-Model-allowed two-neutrino double electron capture ($2νECEC$) has been predicted for a number of isotopes, but only observed in $^{78}$Kr, $^{130}$Ba and, recently, $^{124}$Xe. The sensitivity to this decay establishes a benchmark for the ultimate experimental goal, namely the potential to discover also the lepton-number-violating neutrinoless version of this process, $0νECEC$. Here we report on the current sensitivity of the NEXT-White detector to $^{124}$Xe $2νECEC$ and on the extrapolation to NEXT-100. Using simulated data for the $2νECEC$ signal and real data from NEXT-White operated with $^{124}$Xe-depleted gas as background, we define an optimal event selection that maximizes the NEXT-White sensitivity. We estimate that, for NEXT-100 operated with xenon gas isotopically enriched with 1 kg of $^{124}$Xe and for a 5-year run, a sensitivity to the $2νECEC$ half-life of $6 \times 10^{22}$ y (at 90% confidence level) or better can be reached.
△ Less
Submitted 15 March, 2021; v1 submitted 12 June, 2020;
originally announced June 2020.
-
Solar Neutrino Detection Sensitivity in DARWIN via Electron Scattering
Authors:
J. Aalbers,
F. Agostini,
S. E. M. Ahmed Maouloud,
M. Alfonsi,
L. Althueser,
F. Amaro,
J. Angevaare,
V. C. Antochi,
B. Antunovic,
E. Aprile,
L. Arazi,
F. Arneodo,
M. Balzer,
L. Baudis,
D. Baur,
M. L. Benabderrahmane,
Y. Biondi,
A. Bismark,
C. Bourgeois,
A. Breskin,
P. A. Breur,
A. Brown,
E. Brown,
S. Brünner,
G. Bruno
, et al. (141 additional authors not shown)
Abstract:
We detail the sensitivity of the liquid xenon (LXe) DARWIN observatory to solar neutrinos via elastic electron scattering. We find that DARWIN will have the potential to measure the fluxes of five solar neutrino components: $pp$, $^7$Be, $^{13}$N, $^{15}$O and $pep$. The precision of the $^{13}$N, $^{15}$O and $pep$ components is hindered by the double-beta decay of $^{136}$Xe and, thus, would ben…
▽ More
We detail the sensitivity of the liquid xenon (LXe) DARWIN observatory to solar neutrinos via elastic electron scattering. We find that DARWIN will have the potential to measure the fluxes of five solar neutrino components: $pp$, $^7$Be, $^{13}$N, $^{15}$O and $pep$. The precision of the $^{13}$N, $^{15}$O and $pep$ components is hindered by the double-beta decay of $^{136}$Xe and, thus, would benefit from a depleted target. A high-statistics observation of $pp$ neutrinos would allow us to infer the values of the weak mixing angle, $\sin^2θ_w$, and the electron-type neutrino survival probability, $P_e$, in the electron recoil energy region from a few keV up to 200 keV for the first time, with relative precision of 5% and 4%, respectively, at an exposure of 300 ty. An observation of $pp$ and $^7$Be neutrinos would constrain the neutrino-inferred solar luminosity down to 0.2%. A combination of all flux measurements would distinguish between the high (GS98) and low metallicity (AGS09) solar models with 2.1-2.5$σ$ significance, independent of external measurements from other experiments or a measurement of $^8$B neutrinos through coherent elastic neutrino-nucleus scattering in DARWIN. Finally, we demonstrate that with a depleted target DARWIN may be sensitive to the neutrino capture process of $^{131}$Xe.
△ Less
Submitted 20 December, 2020; v1 submitted 4 June, 2020;
originally announced June 2020.
-
Sensitivity of the DARWIN observatory to the neutrinoless double beta decay of $^{136}$Xe
Authors:
F. Agostini,
S. E. M. Ahmed Maouloud,
L. Althueser,
F. Amaro,
B. Antunovic,
E. Aprile,
L. Baudis,
D. Baur,
Y. Biondi,
A. Bismark,
P. A. Breur,
A. Brown,
G. Bruno,
R. Budnik,
C. Capelli,
J. Cardoso,
D. Cichon,
M. Clark,
A. P. Colijn,
J. J. Cuenca-García,
J. P. Cussonneau,
M. P. Decowski,
A. Depoian,
J. Dierle,
P. Di Gangi
, et al. (70 additional authors not shown)
Abstract:
The DARWIN observatory is a proposed next-generation experiment to search for particle dark matter and for the neutrinoless double beta decay of $^{136}$Xe. Out of its 50$\,$t total natural xenon inventory, 40$\,$t will be the active target of a time projection chamber which thus contains about 3.6 t of $^{136}$Xe. Here, we show that its projected half-life sensitivity is $2.4\times10^{27}\,$yr, u…
▽ More
The DARWIN observatory is a proposed next-generation experiment to search for particle dark matter and for the neutrinoless double beta decay of $^{136}$Xe. Out of its 50$\,$t total natural xenon inventory, 40$\,$t will be the active target of a time projection chamber which thus contains about 3.6 t of $^{136}$Xe. Here, we show that its projected half-life sensitivity is $2.4\times10^{27}\,$yr, using a fiducial volume of 5t of natural xenon and 10$\,$yr of operation with a background rate of less than 0.2$~$events/(t$\cdot$yr) in the energy region of interest. This sensitivity is based on a detailed Monte Carlo simulation study of the background and event topologies in the large, homogeneous target. DARWIN will be comparable in its science reach to dedicated double beta decay experiments using xenon enriched in $^{136}$Xe.
△ Less
Submitted 7 September, 2020; v1 submitted 25 March, 2020;
originally announced March 2020.
-
Mitigation of Backgrounds from Cosmogenic $^{137}$Xe in Xenon Gas Experiments using $^{3}$He Neutron Capture
Authors:
L. Rogers,
B. J. P. Jones,
A. Laing,
S. **ulkar,
K. Woodruff,
C. Adams,
V. Álvarez,
L. Arazi,
I. J. Arnquist,
C. D. R Azevedo,
K. Bailey,
F. Ballester,
J. M. Benlloch-Rodríguez,
F. I. G. M. Borges,
N. Byrnes,
S. Cárcel,
J. V. Carrión,
S. Cebrián,
E. Church,
C. A. N. Conde,
T. Contreras,
G. Díaz,
J. Díaz,
M. Diesburg,
R. Dingler
, et al. (67 additional authors not shown)
Abstract:
\Xe{136} is used as the target medium for many experiments searching for \bbnonu. Despite underground operation, cosmic muons that reach the laboratory can produce spallation neutrons causing activation of detector materials. A potential background that is difficult to veto using muon tagging comes in the form of \Xe{137} created by the capture of neutrons on \Xe{136}. This isotope decays via beta…
▽ More
\Xe{136} is used as the target medium for many experiments searching for \bbnonu. Despite underground operation, cosmic muons that reach the laboratory can produce spallation neutrons causing activation of detector materials. A potential background that is difficult to veto using muon tagging comes in the form of \Xe{137} created by the capture of neutrons on \Xe{136}. This isotope decays via beta decay with a half-life of 3.8 minutes and a \Qb\ of $\sim$4.16 MeV. This work proposes and explores the concept of adding a small percentage of \He{3} to xenon as a means to capture thermal neutrons and reduce the number of activations in the detector volume. When using this technique we find the contamination from \Xe{137} activation can be reduced to negligible levels in tonne and multi-tonne scale high pressure gas xenon neutrinoless double beta decay experiments running at any depth in an underground laboratory.
△ Less
Submitted 27 May, 2020; v1 submitted 29 January, 2020;
originally announced January 2020.
-
Radiogenic backgrounds in the NEXT double beta decay experiment
Authors:
NEXT Collaboration,
P. Novella,
B. Palmeiro,
M. Sorel,
A. Usón,
P. Ferrario,
J. J. Gómez-Cadenas,
C. Adams,
V. Álvarez,
L. Arazi,
I. J. Arnquist,
C. D. R Azevedo,
K. Bailey,
F. Ballester,
J. M. Benlloch-Rodríguez,
F. I. G. M. Borges,
N. Byrnes,
S. Cárcel,
J. V. Carrión,
S. Cebrián,
E. Church,
C. A. N. Conde,
T. Contreras,
G. Díaz López,
J. Díaz
, et al. (66 additional authors not shown)
Abstract:
Natural radioactivity represents one of the main backgrounds in the search for neutrinoless double beta decay. Within the NEXT physics program, the radioactivity-induced backgrounds are measured with the NEXT-White detector. Data from 37.9 days of low-background operations at the Laboratorio Subterráneo de Canfranc with xenon depleted in $^{136}$Xe are analyzed to derive a total background rate of…
▽ More
Natural radioactivity represents one of the main backgrounds in the search for neutrinoless double beta decay. Within the NEXT physics program, the radioactivity-induced backgrounds are measured with the NEXT-White detector. Data from 37.9 days of low-background operations at the Laboratorio Subterráneo de Canfranc with xenon depleted in $^{136}$Xe are analyzed to derive a total background rate of (0.84$\pm$0.02) mHz above 1000 keV. The comparison of data samples with and without the use of the radon abatement system demonstrates that the contribution of airborne-Rn is negligible. A radiogenic background model is built upon the extensive radiopurity screening campaign conducted by the NEXT Collaboration. A spectral fit to this model yields the specific contributions of $^{60}$Co, $^{40}$K, $^{214}$Bi and $^{208}$Tl to the total background rate, as well as their location in the detector volumes. The results are used to evaluate the impact of the radiogenic backgrounds in the double beta decay analyses, after the application of topological cuts that reduce the total rate to (0.25$\pm$0.01) mHz. Based on the best-fit background model, the NEXT-White median sensitivity to the two-neutrino double beta decay is found to be 3.5$σ$ after 1 year of data taking. The background measurement in a Q$_{ββ}\pm$100 keV energy window validates the best-fit background model also for the neutrinoless double beta decay search with NEXT-100. Only one event is found, while the model expectation is (0.75$\pm$0.12) events.
△ Less
Submitted 9 September, 2019; v1 submitted 31 May, 2019;
originally announced May 2019.
-
Demonstration of the event identification capabilities of the NEXT-White detector
Authors:
NEXT Collaboration,
P. Ferrario,
J. M. Benlloch-Rodríguez,
G. Díaz López,
J. A. Hernando Morata,
M. Kekic,
J. Renner,
A. Usón,
J. J. Gómez-Cadenas,
C. Adams,
V. Álvarez,
L. Arazi,
I. J. Arnquist,
C. D. R Azevedo,
K. Bailey,
F. Ballester,
F. I. G. M. Borges,
N. Byrnes,
S. Cárcel,
J. V. Carrión,
S. Cebrián,
E. Church,
C. A. N. Conde,
T. Contreras,
J. Díaz
, et al. (66 additional authors not shown)
Abstract:
In experiments searching for neutrinoless double-beta decay, the possibility of identifying the two emitted electrons is a powerful tool in rejecting background events and therefore improving the overall sensitivity of the experiment. In this paper we present the first measurement of the efficiency of a cut based on the different event signatures of double and single electron tracks, using the dat…
▽ More
In experiments searching for neutrinoless double-beta decay, the possibility of identifying the two emitted electrons is a powerful tool in rejecting background events and therefore improving the overall sensitivity of the experiment. In this paper we present the first measurement of the efficiency of a cut based on the different event signatures of double and single electron tracks, using the data of the NEXT-White detector, the first detector of the NEXT experiment operating underground. Using a \TO\ calibration source to produce signal-like and background-like events with energies near 1.6 MeV, a signal efficiency of $71.6 \pm 1.5_{\textrm{ stat}} \pm 0.3_{\textrm{ sys}} \%$ for a background acceptance of $20.6 \pm 0.4_{\textrm{ stat}} \pm 0.3_{\textrm{ sys}} \%$ is found, in good agreement with Monte Carlo simulations. An extrapolation to the energy region of the neutrinoless double beta decay by means of Monte Carlo simulations is also carried out, and the results obtained show an improvement in background rejection over those obtained at lower energies.
△ Less
Submitted 11 September, 2019; v1 submitted 30 May, 2019;
originally announced May 2019.
-
Electroluminescence TPCs at the thermal diffusion limit
Authors:
C. A. O. Henriques,
C. M. B. Monteiro,
D. González-Díaz,
C. D. R Azevedo,
E. D. C. Freitas,
R. D. P. Mano,
M. R. Jorge,
A. F. M. Fernandes,
J. J. Gómez-Cadenas,
L. M. P. Fernandes,
C. Adams,
V. Álvarez,
L. Arazi,
K. Bailey,
F. Ballester,
J. M. Benlloch-Rodríguez,
F. I. G. M. Borges,
A. Botas,
S. Cárcel,
J. V. Carrión,
S. Cebrián,
C. A. N. Conde,
J. Díaz,
M. Diesburg,
J. Escada
, et al. (56 additional authors not shown)
Abstract:
The NEXT experiment aims at searching for the hypothetical neutrinoless double-beta decay from the ${}^{136}$Xe isotope using a high-purity xenon TPC. Efficient discrimination of the events through pattern recognition of the topology of primary ionisation tracks is a major requirement for the experiment. However, it is limited by the diffusion of electrons. It is known that the addition of a small…
▽ More
The NEXT experiment aims at searching for the hypothetical neutrinoless double-beta decay from the ${}^{136}$Xe isotope using a high-purity xenon TPC. Efficient discrimination of the events through pattern recognition of the topology of primary ionisation tracks is a major requirement for the experiment. However, it is limited by the diffusion of electrons. It is known that the addition of a small fraction of a molecular gas to xenon reduces electron diffusion. On the other hand, the electroluminescence (EL) yield drops and the achievable energy resolution may be compromised. We have studied the effect of adding several molecular gases to xenon (CO${}_{2}$, CH${}_{4}$ and CF${}_{4}$) on the EL yield and energy resolution obtained in a small prototype of driftless gas proportional scintillation counter. We have compared our results on the scintillation characteristics (EL yield and energy resolution) with a microscopic simulation, obtaining the diffusion coefficients in those conditions as well. Accordingly, electron diffusion may be reduced from about 10 mm/$\sqrt{\mathrm{m}}$ for pure xenon down to 2.5 mm/$\sqrt{\mathrm{m}}$ using additive concentrations of about 0.05%, 0.2% and 0.02% for CO${}_{2}$, CH${}_{4}$ and CF${}_{4}$, respectively. Our results show that CF${}_{4}$ admixtures present the highest EL yield in those conditions, but very poor energy resolution as a result of huge fluctuations observed in the EL formation. CH${}_{4}$ presents the best energy resolution despite the EL yield being the lowest. The results obtained with xenon admixtures are extrapolated to the operational conditions of the NEXT-100 TPC. CO${}_{2}$ and CH${}_{4}$ show potential as molecular additives in a large xenon TPC, CH${}_{4}$ showing the best performance and stability to be used in the NEXT-100 TPC, with an extrapolated energy resolution of 0.4% at 2.45 MeV for concentrations below 0.4%.
△ Less
Submitted 30 October, 2018; v1 submitted 15 June, 2018;
originally announced June 2018.
-
Calibration of the NEXT-White detector using $^{83m}\mathrm{Kr}$ decays
Authors:
G. Martínez-Lema,
J. A. Hernando Morata,
B. Palmeiro,
A. Botas,
P. Ferrario,
F. Monrabal,
A. Laing,
J. Renner,
A. Simón,
J. J. Gómez-Cadenas,
C. Adams,
V. Álvarez,
L. Arazi,
C. D. R. Azevedo,
K. Bailey,
F. Ballester,
J. M. Benlloch-Rodríguez,
F. I. G. M. Borges,
S. Cárcel,
J. V. Carrión,
S. Cebrián,
C. A. N. Conde,
J. Díaz,
M. Diesburg,
J. Escada
, et al. (52 additional authors not shown)
Abstract:
The NEXT-White (NEW) detector is currently the largest radio-pure high-pressure xenon gas time projection chamber with electroluminescent readout in the world. NEXT-White has been operating at Laboratorio Subterráneo de Canfranc (LSC) since October 2016. This paper describes the calibrations performed with $^{83m}\mathrm{Kr}$ decays during a long run taken from March to November 2017 (Run II). Kry…
▽ More
The NEXT-White (NEW) detector is currently the largest radio-pure high-pressure xenon gas time projection chamber with electroluminescent readout in the world. NEXT-White has been operating at Laboratorio Subterráneo de Canfranc (LSC) since October 2016. This paper describes the calibrations performed with $^{83m}\mathrm{Kr}$ decays during a long run taken from March to November 2017 (Run II). Krypton calibrations are used to correct for the finite drift-electron lifetime as well as for the dependence of the measured energy on the event position which is mainly caused by variations in solid angle coverage. After producing calibration maps to correct for both effects we measure an excellent energy resolution for 41.5 keV point-like deposits of (4.553 $\pm$ 0.010 (stat.) $\pm$ 0.324 (sys.)) % FWHM in the full chamber and (3.804 $\pm$ 0.013 (stat.) $\pm$ 0.112 (sys.)) % FWHM in a restricted fiducial volume. Using naive 1/$\sqrt{E}$ scaling, these values translate into resolutions of (0.516 $\pm$ 0.0014 (stat.) $\pm$ 0.0421 (sys.)) % FWHM and (0.4943 $\pm$ 0.0017 (stat.) $\pm$ 0.0146 (sys.)) % FWHM at the $Q_{ββ}$ energy of xenon double beta decay (2458 keV), well within range of our target value of 1%.
△ Less
Submitted 18 September, 2018; v1 submitted 5 April, 2018;
originally announced April 2018.
-
Electron drift properties in high pressure gaseous xenon
Authors:
NEXT Collaboration,
A. Simón,
R. Felkai,
G. Martínez-Lema,
F. Monrabal,
D. González-Díaz,
M. Sorel,
J. A. Hernando Morata,
J. J. Gómez-Cadenas,
C. Adams,
V. Álvarez,
L. Arazi,
C. D. R. Azevedo,
J. M. Benlloch-Rodríguez,
F. I. G. M. Borges,
A. Botas,
S. Cárcel,
J. V. Carrión,
S. Cebrián,
C. A. N. Conde,
J. Díaz,
M. Diesburg,
J. Escada,
R. Esteve,
L. M. P. Fernandes
, et al. (51 additional authors not shown)
Abstract:
Gaseous time projection chambers (TPC) are a very attractive detector technology for particle tracking. Characterization of both drift velocity and diffusion is of great importance to correctly assess their tracking capabilities. NEXT-White is a High Pressure Xenon gas TPC with electroluminescent amplification, a 1:2 scale model of the future NEXT-100 detector, which will be dedicated to neutrinol…
▽ More
Gaseous time projection chambers (TPC) are a very attractive detector technology for particle tracking. Characterization of both drift velocity and diffusion is of great importance to correctly assess their tracking capabilities. NEXT-White is a High Pressure Xenon gas TPC with electroluminescent amplification, a 1:2 scale model of the future NEXT-100 detector, which will be dedicated to neutrinoless double beta decay searches. NEXT-White has been operating at Canfranc Underground Laboratory (LSC) since December 2016. The drift parameters have been measured using $^{83m}$Kr for a range of reduced drift fields at two different pressure regimes, namely 7.2 bar and 9.1 bar. The results have been compared with Magboltz simulations. Agreement at the 5% level or better has been found for drift velocity, longitudinal diffusion and transverse diffusion.
△ Less
Submitted 28 May, 2018; v1 submitted 5 April, 2018;
originally announced April 2018.
-
Measurement of radon-induced backgrounds in the NEXT double beta decay experiment
Authors:
NEXT Collaboration,
P. Novella,
B. Palmeiro,
A. Simón,
M. Sorel,
C. Adams,
P. Ferrario,
G. Martínez-Lema,
F. Monrabal,
G. Zuzel,
J. J. Gómez-Cadenas,
V. Álvarez,
L. Arazi,
C. D. R Azevedo,
K. Bailey,
F. Ballester,
J. M. Benlloch-Rodríguez,
F. I. G. M. Borges,
A. Botas,
S. Cárcel,
J. V. Carrión,
S. Cebrián,
C. A. N. Conde,
J. Díaz,
M. Diesburg
, et al. (57 additional authors not shown)
Abstract:
The measurement of the internal $^{222}$Rn activity in the NEXT-White detector during the so-called Run-II period with $^{136}$Xe-depleted xenon is discussed in detail, together with its implications for double beta decay searches in NEXT. The activity is measured through the alpha production rate induced in the fiducial volume by $^{222}$Rn and its alpha-emitting progeny. The specific activity is…
▽ More
The measurement of the internal $^{222}$Rn activity in the NEXT-White detector during the so-called Run-II period with $^{136}$Xe-depleted xenon is discussed in detail, together with its implications for double beta decay searches in NEXT. The activity is measured through the alpha production rate induced in the fiducial volume by $^{222}$Rn and its alpha-emitting progeny. The specific activity is measured to be $(38.1\pm 2.2~\mathrm{(stat.)}\pm 5.9~\mathrm{(syst.)})$~mBq/m$^3$. Radon-induced electrons have also been characterized from the decay of the $^{214}$Bi daughter ions plating out on the cathode of the time projection chamber. From our studies, we conclude that radon-induced backgrounds are sufficiently low to enable a successful NEXT-100 physics program, as the projected rate contribution should not exceed 0.1~counts/yr in the neutrinoless double beta decay sample.
△ Less
Submitted 10 October, 2018; v1 submitted 2 April, 2018;
originally announced April 2018.
-
Demonstration of Single Barium Ion Sensitivity for Neutrinoless Double Beta Decay using Single Molecule Fluorescence Imaging
Authors:
A. D. McDonald,
B. J. P. Jones,
D. R. Nygren,
C. Adams,
V. Alvarez,
C. D. R. Azevedo,
J. M. Benlloch-Rodrıguez,
F. I. G. M. Borges,
A. Botas,
S. Carcel,
J. V. Carrion,
S. Cebrian,
C. A. N. Conde,
J. Dıaz,
M. Diesburg,
J. Escada,
R. Esteve,
R. Felkai,
L. M. P. Fernandes,
P. Ferrario,
A. L. Ferreira,
E. D. C. Freitas,
A. Goldschmidt,
J. J. Gomez-Cadenas,
D. Gonzalez-Dıaz
, et al. (49 additional authors not shown)
Abstract:
A new method to tag the barium daughter in the double beta decay of $^{136}$Xe is reported. Using the technique of single molecule fluorescent imaging (SMFI), individual barium dication (Ba$^{++}$) resolution at a transparent scanning surface has been demonstrated. A single-step photo-bleach confirms the single ion interpretation. Individual ions are localized with super-resolution ($\sim$2~nm), a…
▽ More
A new method to tag the barium daughter in the double beta decay of $^{136}$Xe is reported. Using the technique of single molecule fluorescent imaging (SMFI), individual barium dication (Ba$^{++}$) resolution at a transparent scanning surface has been demonstrated. A single-step photo-bleach confirms the single ion interpretation. Individual ions are localized with super-resolution ($\sim$2~nm), and detected with a statistical significance of 12.9~$σ$ over backgrounds. This lays the foundation for a new and potentially background-free neutrinoless double beta decay technology, based on SMFI coupled to high pressure xenon gas time projection chambers.
△ Less
Submitted 6 February, 2018; v1 submitted 13 November, 2017;
originally announced November 2017.
-
Helium-Xenon mixtures to improve topological signature in high pressure gas Xenon TPCs
Authors:
R. Felkai,
F. Monrabal,
D. Gonzalez-Díaz,
M. Sorel,
N. López-March,
J. J. Gómez-Cadenas,
C. Adams,
V. Álvarez,
L. Arazi,
C. D. R. Azevedo,
J. M. Benlloch-Rodríguez,
F. I. G. M. Borges,
A. Botas,
S. Cárcel,
J. V. Carrión,
S. Cebrián,
C. A. N. Conde,
J. Díaz,
M. Diesburg,
J. Escada,
R. Esteve,
L. M. P. Fernandes,
P. Ferrario,
A. L. Ferreira,
E. D. C. Freitas
, et al. (50 additional authors not shown)
Abstract:
Within the framework of xenon-based double beta decay experiments, we propose the possibility to improve the background rejection of an electroluminescent Time Projection Chamber (EL TPC) by reducing the diffusion of the drifting electrons while kee** nearly intact the energy resolution of a pure xenon EL TPC. Based on state-of-the-art microscopic simulations, a substantial addition of helium, a…
▽ More
Within the framework of xenon-based double beta decay experiments, we propose the possibility to improve the background rejection of an electroluminescent Time Projection Chamber (EL TPC) by reducing the diffusion of the drifting electrons while kee** nearly intact the energy resolution of a pure xenon EL TPC. Based on state-of-the-art microscopic simulations, a substantial addition of helium, around 10 or 15~\%, may reduce drastically the transverse diffusion down to 2.5~mm/$\sqrt{\mathrm{m}}$ from the 10.5~mm/$\sqrt{\mathrm{m}}$ of pure xenon. The longitudinal diffusion remains around 4~mm/$\sqrt{\mathrm{m}}$. Light production studies have been performed as well. They show that the relative variation in energy resolution introduced by such a change does not exceed a few percent, which leaves the energy resolution practically unchanged. The technical caveats of using photomultipliers close to an helium atmosphere are also discussed in detail.
△ Less
Submitted 20 December, 2018; v1 submitted 16 October, 2017;
originally announced October 2017.
-
Radiopurity assessment of the energy readout for the NEXT double beta decay experiment
Authors:
S. Cebrián,
J. Pérez,
I. Bandac,
L. Labarga,
V. Álvarez,
C. D. R. Azevedo,
J. M. Benlloch-Rodríguez,
F. I. G. M. Borges,
A. Botas,
S. Cárcel,
J. V. Carrión,
C. A. N. Conde,
J. Díaz,
M. Diesburg,
J. Escada,
R. Esteve,
R. Felkai,
L. M. P. Fernandes,
P. Ferrario,
A. L. Ferreira,
E. D. C. Freitas,
A. Goldschmidt,
J. J. Gómez-Cadenas,
D. González-Díaz,
R. M. Gutiérrez
, et al. (45 additional authors not shown)
Abstract:
The Neutrino Experiment with a Xenon Time-Projection Chamber (NEXT) experiment intends to investigate the neutrinoless double beta decay of 136Xe, and therefore requires a severe suppression of potential backgrounds. An extensive material screening and selection process was undertaken to quantify the radioactivity of the materials used in the experiment. Separate energy and tracking readout planes…
▽ More
The Neutrino Experiment with a Xenon Time-Projection Chamber (NEXT) experiment intends to investigate the neutrinoless double beta decay of 136Xe, and therefore requires a severe suppression of potential backgrounds. An extensive material screening and selection process was undertaken to quantify the radioactivity of the materials used in the experiment. Separate energy and tracking readout planes using different sensors allow us to combine the measurement of the topological signature of the event for background discrimination with the energy resolution optimization. The design of radiopure readout planes, in direct contact with the gas detector medium, was especially challenging since the required components typically have activities too large for experiments demanding ultra-low background conditions. After studying the tracking plane, here the radiopurity control of the energy plane is presented, mainly based on gamma-ray spectroscopy using ultra-low background germanium detectors at the Laboratorio Subterráneo de Canfranc (Spain). All the available units of the selected model of photomultiplier have been screened together with most of the components for the bases, enclosures and windows. According to these results for the activity of the relevant radioisotopes, the selected components of the energy plane would give a contribution to the overall background level in the region of interest of at most 2.4 x 10-4 counts keV-1 kg-1 y-1, satisfying the sensitivity requirements of the NEXT experiment.
△ Less
Submitted 21 August, 2017; v1 submitted 19 June, 2017;
originally announced June 2017.
-
Application and performance of an ML-EM algorithm in NEXT
Authors:
NEXT Collaboration,
A. Simón,
C. Lerche,
F. Monrabal,
J. J. Gómez-Cadenas,
V. Álvarez,
C. D. R. Azevedo,
J. M. Benlloch-Rodríguez,
F. I. G. M. Borges,
A. Botas,
S. Cárcel,
J. V. Carrión,
S. Cebrián,
C. A. N. Conde,
J. Díaz,
M. Diesburg,
J. Escada,
R. Esteve,
R. Felkai,
L. M. P. Fernandes,
P. Ferrario,
A. L. Ferreira,
E. D. C. Freitas,
A. Goldschmidt,
D. González-Díaz
, et al. (45 additional authors not shown)
Abstract:
The goal of the NEXT experiment is the observation of neutrinoless double beta decay in $^{136}$Xe using a gaseous xenon TPC with electroluminescent amplification and specialized photodetector arrays for calorimetry and tracking. The NEXT Collaboration is exploring a number of reconstruction algorithms to exploit the full potential of the detector. This paper describes one of them: the Maximum Lik…
▽ More
The goal of the NEXT experiment is the observation of neutrinoless double beta decay in $^{136}$Xe using a gaseous xenon TPC with electroluminescent amplification and specialized photodetector arrays for calorimetry and tracking. The NEXT Collaboration is exploring a number of reconstruction algorithms to exploit the full potential of the detector. This paper describes one of them: the Maximum Likelihood Expectation Maximization (ML-EM) method, a generic iterative algorithm to find maximum-likelihood estimates of parameters that has been applied to solve many different types of complex inverse problems. In particular, we discuss a bi-dimensional version of the method in which the photosensor signals integrated over time are used to reconstruct a transverse projection of the event. First results show that, when applied to detector simulation data, the algorithm achieves nearly optimal energy resolution (better than 0.5% FWHM at the Q value of $^{136}$Xe) for events distributed over the full active volume of the TPC.
△ Less
Submitted 29 May, 2017;
originally announced May 2017.
-
Background rejection in NEXT using deep neural networks
Authors:
NEXT Collaboration,
J. Renner,
A. Farbin,
J. Muñoz Vidal,
J. M. Benlloch-Rodríguez,
A. Botas,
P. Ferrario,
J. J. Gómez-Cadenas,
V. Álvarez,
C. D. R. Azevedo,
F. I. G. Borges,
S. Cárcel,
J. V. Carrión,
S. Cebrián,
A. Cervera,
C. A. N. Conde,
J. Díaz,
M. Diesburg,
R. Esteve,
L. M. P. Fernandes,
A. L. Ferreira,
E. D. C. Freitas,
A. Goldschmidt,
D. González-Díaz,
R. M. Gutiérrez
, et al. (42 additional authors not shown)
Abstract:
We investigate the potential of using deep learning techniques to reject background events in searches for neutrinoless double beta decay with high pressure xenon time projection chambers capable of detailed track reconstruction. The differences in the topological signatures of background and signal events can be learned by deep neural networks via training over many thousands of events. These net…
▽ More
We investigate the potential of using deep learning techniques to reject background events in searches for neutrinoless double beta decay with high pressure xenon time projection chambers capable of detailed track reconstruction. The differences in the topological signatures of background and signal events can be learned by deep neural networks via training over many thousands of events. These networks can then be used to classify further events as signal or background, providing an additional background rejection factor at an acceptable loss of efficiency. The networks trained in this study performed better than previous methods developed based on the use of the same topological signatures by a factor of 1.2 to 1.6, and there is potential for further improvement.
△ Less
Submitted 18 October, 2016; v1 submitted 20 September, 2016;
originally announced September 2016.
-
Sensitivity of NEXT-100 to neutrinoless double beta decay
Authors:
NEXT Collaboration,
J. Martín-Albo,
J. Muñoz Vidal,
P. Ferrario,
M. Nebot-Guinot,
J. J. Gómez-Cadenas,
V. Álvarez,
C. D. R. Azevedo,
F. I. G. Borges,
S. Cárcel,
S. Cebrián,
A. Cervera,
C. A. N. Conde,
J. Díaz,
M. Diesburg,
R. Esteve,
L. M. P. Fernandes,
A. L. Ferreira,
E. D. C. Freitas,
A. Goldschmidt,
D. González-Díaz,
R. M. Gutiérrez,
J. Hauptman,
C. A. O. Henriques,
J. A. Hernando Morata
, et al. (38 additional authors not shown)
Abstract:
NEXT-100 is an electroluminescent high-pressure xenon gas time projection chamber that will search for the neutrinoless double beta ($ββ0 ν$) decay of Xe-136. The detector possesses two features of great value for $ββ0 ν$ searches: energy resolution better than 1\% FWHM at the $Q$ value of Xe-136 and track reconstruction for the discrimination of signal and background events. This combination resu…
▽ More
NEXT-100 is an electroluminescent high-pressure xenon gas time projection chamber that will search for the neutrinoless double beta ($ββ0 ν$) decay of Xe-136. The detector possesses two features of great value for $ββ0 ν$ searches: energy resolution better than 1\% FWHM at the $Q$ value of Xe-136 and track reconstruction for the discrimination of signal and background events. This combination results in excellent sensitivity, as discussed in this paper. Material-screening measurements and a detailed Monte Carlo detector simulation predict a background rate for NEXT-100 of at most $4\times10^{-4}$ counts keV$^{-1}$ kg$^{-1}$ yr$^{-1}$. Accordingly, the detector will reach a sensitivity to the \bbonu-decay half-life of $2.8\times10^{25}$ years (90\% CL) for an exposure of 100 $\mathrm{kg}\cdot\mathrm{year}$, or $6.0\times10^{25}$ years after a run of 3 effective years.
△ Less
Submitted 31 May, 2016; v1 submitted 30 November, 2015;
originally announced November 2015.
-
An homeopathic cure to pure Xenon large diffusion
Authors:
C. D. R. Azevedo,
L. M. P. Fernandes,
E. D. C. Freitas,
D. Gonzalez-Diaz,
F. Monrabal,
C. M. B. Monteiro,
J. M. F. Dos Santos,
J. F. C. A. Veloso,
J. J Gomez-Cadenas
Abstract:
The NEXT neutrinoless double beta decay experiment will use a high- pressure gas electroluminescence-based TPC to search for the decay of Xe-136. One of the main advantages of this technology is the possibility to reconstruct the topology of events with energies close to Qbb. The rejection potential associated to the topology reconstruction is limited by our capacity to prop- erly reconstruct the…
▽ More
The NEXT neutrinoless double beta decay experiment will use a high- pressure gas electroluminescence-based TPC to search for the decay of Xe-136. One of the main advantages of this technology is the possibility to reconstruct the topology of events with energies close to Qbb. The rejection potential associated to the topology reconstruction is limited by our capacity to prop- erly reconstruct the original path of the electrons in the gas. This reconstruction is limited by different factors that include the geometry of the detector, the density of the sensors in the tracking plane and the separation among them, etc. Ultimately, the resolution is limited by the physics of electron diffusion in the gas. In this paper we present a series of molecular additives that can be used in Xenon gas at very low partial pressure to reduce both longitudinal and transverse diffusion. We will show the results of different Monte-Carlo simulations of electron transport in the gas mixtures from wich we have extracted the value of some important parameters like diffusion, drift velocity and light yields. These results show that there is a series of candidates that can reduce diffusion without affecting the energy resolution of the detector and they should be studied experimentally. A comparison with preliminary results from such an ongoing experimental effort is given.
△ Less
Submitted 23 November, 2015;
originally announced November 2015.
-
First proof of topological signature in the high pressure xenon gas TPC with electroluminescence amplification for the NEXT experiment
Authors:
NEXT Collaboration,
P. Ferrario,
A. Laing,
N. López-March,
J. J. Gómez-Cadenas,
V. Álvarez,
C. D. R. Azevedo,
F. I. G. Borges,
S. Cárcel,
S. Cebrián,
A. Cervera,
C. A. N. Conde,
T. Dafni,
J. Díaz,
M. Diesburg,
R. Esteve,
L. M. P. Fernandes,
A. L. Ferreira,
E. D. C. Freitas,
V. M. Gehman,
A. Goldschmidt,
D. González-Díaz,
R. M. Gutiérrez,
J. Hauptman,
C. A. O. Henriques
, et al. (45 additional authors not shown)
Abstract:
The NEXT experiment aims to observe the neutrinoless double beta decay of xenon in a high-pressure Xe136 gas TPC using electroluminescence (EL) to amplify the signal from ionization. One of the main advantages of this technology is the possibility to reconstruct the topology of events with energies close to Qbb. This paper presents the first demonstration that the topology provides extra handles t…
▽ More
The NEXT experiment aims to observe the neutrinoless double beta decay of xenon in a high-pressure Xe136 gas TPC using electroluminescence (EL) to amplify the signal from ionization. One of the main advantages of this technology is the possibility to reconstruct the topology of events with energies close to Qbb. This paper presents the first demonstration that the topology provides extra handles to reject background events using data obtained with the NEXT-DEMO prototype.
Single electrons resulting from the interactions of Na22 1275 keV gammas and electron-positron pairs produced by conversions of gammas from the Th228 decay chain were used to represent the background and the signal in a double beta decay. These data were used to develop algorithms for the reconstruction of tracks and the identification of the energy deposited at the end-points, providing an extra background rejection factor of 24.3 +- 1.4 (stat.)%, while maintaining an efficiency of 66.7 +- 1% for signal events.
△ Less
Submitted 18 January, 2016; v1 submitted 21 July, 2015;
originally announced July 2015.
-
Radon and material radiopurity assessment for the NEXT double beta decay experiment
Authors:
S. Cebrián,
J. Pérez,
I. Bandac,
L. Labarga,
V. Álvarez,
A. I. Barrado,
A. Bettini,
F. I. G. M. Borges,
M. Camargo,
S. Cárcel,
A. Cervera,
C. A. N. Conde,
E. Conde,
T. Dafni,
J. Díaz,
R. Esteve,
L. M. P. Fernandes,
M. Fernández,
P. Ferrario,
E. D. C. Freitas,
L. M. P. Fernandes,
V. M. Gehman,
A. Goldschmidt,
J. J. Gómez-Cadenas,
D. González-Díaz
, et al. (46 additional authors not shown)
Abstract:
The Neutrino Experiment with a Xenon TPC (NEXT), intended to investigate the neutrinoless double beta decay using a high-pressure xenon gas TPC filled with Xe enriched in 136Xe at the Canfranc Underground Laboratory in Spain, requires ultra-low background conditions demanding an exhaustive control of material radiopurity and environmental radon levels. An extensive material screening process is un…
▽ More
The Neutrino Experiment with a Xenon TPC (NEXT), intended to investigate the neutrinoless double beta decay using a high-pressure xenon gas TPC filled with Xe enriched in 136Xe at the Canfranc Underground Laboratory in Spain, requires ultra-low background conditions demanding an exhaustive control of material radiopurity and environmental radon levels. An extensive material screening process is underway for several years based mainly on gamma-ray spectroscopy using ultra-low background germanium detectors in Canfranc but also on mass spectrometry techniques like GDMS and ICPMS. Components from shielding, pressure vessel, electroluminescence and high voltage elements and energy and tracking readout planes have been analyzed, hel** in the final design of the experiment and in the construction of the background model. The latest measurements carried out will be presented and the implication on NEXT of their results will be discussed. The commissioning of the NEW detector, as a first step towards NEXT, has started in Canfranc; in-situ measurements of airborne radon levels were taken there to optimize the system for radon mitigation and will be shown too.
△ Less
Submitted 26 May, 2015;
originally announced May 2015.
-
An improved measurement of electron-ion recombination in high-pressure xenon gas
Authors:
NEXT Collaboration,
L. Serra,
M. Sorel,
V. Álvarez,
F. I. G. Borges,
M. Camargo,
S. Cárcel,
S. Cebrián,
A. Cervera,
C. A. N. Conde,
T. Dafni,
J. Díaz,
R. Esteve,
L. M. P. Fernandes,
P. Ferrario,
A. L. Ferreira,
E. D. C. Freitas,
V. M. Gehman,
A. Goldschmidt,
J. J. Gómez-Cadenas,
D. González-Díaz,
R. M. Gutiérrez,
J. Hauptman,
J. A. Hernando Morata,
D. C. Herrera
, et al. (42 additional authors not shown)
Abstract:
We report on results obtained with the NEXT-DEMO prototype of the NEXT-100 high-pressure xenon gas time projection chamber (TPC), exposed to an alpha decay calibration source. Compared to our previous measurements with alpha particles, an upgraded detector and improved analysis techniques have been used. We measure event-by-event correlated fluctuations between ionization and scintillation due to…
▽ More
We report on results obtained with the NEXT-DEMO prototype of the NEXT-100 high-pressure xenon gas time projection chamber (TPC), exposed to an alpha decay calibration source. Compared to our previous measurements with alpha particles, an upgraded detector and improved analysis techniques have been used. We measure event-by-event correlated fluctuations between ionization and scintillation due to electron-ion recombination in the gas, with correlation coeffcients between -0.80 and -0.56 depending on the drift field conditions. By combining the two signals, we obtain a 2.8 % FWHM energy resolution for 5.49 MeV alpha particles and a measurement of the optical gain of the electroluminescent TPC. The improved energy resolution also allows us to measure the specific activity of the radon in the gas due to natural impurities. Finally, we measure the average ratio of excited to ionized atoms produced in the xenon gas by alpha particles to be $0.561\pm 0.045$, translating into an average energy to produce a primary scintillation photon of $W_{\rm ex}=(39.2\pm 3.2)$ eV.
△ Less
Submitted 3 February, 2015; v1 submitted 11 December, 2014;
originally announced December 2014.
-
Radiopurity assessment of the tracking readout for the NEXT double beta decay experiment
Authors:
S. Cebrián,
J. Pérez,
I. Bandac,
L. Labarga,
V. Álvarez,
A. I. Barrado,
A. Bettini,
F. I. G. M. Borges,
M. Camargo,
S. Cárcel,
A. Cervera,
C. A. N. Conde,
E. Conde,
T. Dafni,
J. Díaz,
R. Esteve,
L. M. P. Fernandes,
M. Fernández,
P. Ferrario,
A. L. Ferreira,
E. D. C. Freitas,
V. M. Gehman,
A. Goldschmidt,
J. J. Gómez-Cadenas,
D. González-Díaz
, et al. (46 additional authors not shown)
Abstract:
The Neutrino Experiment with a Xenon Time-Projection Chamber (NEXT) is intended to investigate the neutrinoless double beta decay of 136Xe, which requires a severe suppression of potential backgrounds; therefore, an extensive screening and selection process is underway to control the radiopurity levels of the materials to be used in the experimental set-up of NEXT. The detector design combines the…
▽ More
The Neutrino Experiment with a Xenon Time-Projection Chamber (NEXT) is intended to investigate the neutrinoless double beta decay of 136Xe, which requires a severe suppression of potential backgrounds; therefore, an extensive screening and selection process is underway to control the radiopurity levels of the materials to be used in the experimental set-up of NEXT. The detector design combines the measurement of the topological signature of the event for background discrimination with the energy resolution optimization. Separate energy and tracking readout planes are based on different sensors: photomultiplier tubes for calorimetry and silicon multi-pixel photon counters for tracking. The design of a radiopure tracking plane, in direct contact with the gas detector medium, was specially challenging since the needed components like printed circuit boards, connectors, sensors or capacitors have typically, according to available information in databases and in the literature, activities too large for experiments requiring ultra-low background conditions. Here, the radiopurity assessment of tracking readout components based on gamma-ray spectroscopy using ultra-low background germanium detectors at the Laboratorio Subterraneo de Canfranc (Spain) is described. According to the obtained results, radiopure enough printed circuit boards made of kapton and copper, silicon photomultipliers and other required components, fulfilling the requirement of an overall background level in the region of interest of at most 8 10-4 counts keV-1 kg-1 y-1, have been identified.
△ Less
Submitted 15 June, 2015; v1 submitted 5 November, 2014;
originally announced November 2014.
-
Results of the material screening program of the NEXT experiment
Authors:
T. Dafni,
V. Alvarez,
I. Bandac,
A. Bettini,
F. I. G. M. Borges,
M. Camargo,
S. Carcel,
S. Cebrian,
A. Cervera,
C. A. N. Conde,
J. Diaz,
R. Esteve,
L. M. P. Fernandes,
M. Fernandez,
P. Ferrario,
A. L. Ferreira,
E. D. C. Freitas,
V. M. Gehman,
A. Goldschmidt,
H. Gomez,
J. J. Gomez-Cadenas,
D. Gonzalez-Diaz,
R. M. Gutierrez,
J. Hauptman,
J. A. Hernando Morata
, et al. (45 additional authors not shown)
Abstract:
The 'Neutrino Experiment with a Xenon TPC (NEXT)', intended to investigate neutrinoless double beta decay, requires extremely low background levels. An extensive material screening and selection process to assess the radioactivity of components is underway combining several techniques, including germanium gamma-ray spectrometry performed at the Canfranc Underground Laboratory; recent results of th…
▽ More
The 'Neutrino Experiment with a Xenon TPC (NEXT)', intended to investigate neutrinoless double beta decay, requires extremely low background levels. An extensive material screening and selection process to assess the radioactivity of components is underway combining several techniques, including germanium gamma-ray spectrometry performed at the Canfranc Underground Laboratory; recent results of this material screening program are presented here.
△ Less
Submitted 5 November, 2014;
originally announced November 2014.
-
Ionization and scintillation of nuclear recoils in gaseous xenon
Authors:
J. Renner,
V. M. Gehman,
A. Goldschmidt,
H. S. Matis,
T. Miller,
Y. Nakajima,
D. Nygren,
C. A. B. Oliveira,
D. Shuman,
V. Álvarez,
F. I. G. Borges,
S. Cárcel,
J. Castel,
S. Cebrián,
A. Cervera,
C. A. N. Conde,
T. Dafni,
T. H. V. T. Dias,
J. Díaz,
R. Esteve,
P. Evtoukhovitch,
L. M. P. Fernandes,
P. Ferrario,
A. L. Ferreira,
E. D. C. Freitas
, et al. (53 additional authors not shown)
Abstract:
Ionization and scintillation produced by nuclear recoils in gaseous xenon at approximately 14 bar have been simultaneously observed in an electroluminescent time projection chamber. Neutrons from radioisotope $α$-Be neutron sources were used to induce xenon nuclear recoils, and the observed recoil spectra were compared to a detailed Monte Carlo employing estimated ionization and scintillation yiel…
▽ More
Ionization and scintillation produced by nuclear recoils in gaseous xenon at approximately 14 bar have been simultaneously observed in an electroluminescent time projection chamber. Neutrons from radioisotope $α$-Be neutron sources were used to induce xenon nuclear recoils, and the observed recoil spectra were compared to a detailed Monte Carlo employing estimated ionization and scintillation yields for nuclear recoils. The ability to discriminate between electronic and nuclear recoils using the ratio of ionization to primary scintillation is demonstrated. These results encourage further investigation on the use of xenon in the gas phase as a detector medium in dark matter direct detection experiments.
△ Less
Submitted 9 September, 2014;
originally announced September 2014.
-
Characterisation of NEXT-DEMO using xenon K$_α$ X-rays
Authors:
NEXT Collaboration,
D. Lorca,
J. Martín-Albo,
A. Laing,
P. Ferrario,
J. J. Gómez-Cadenas,
V. Álvarez,
F. I. G. Borges,
M. Camargo,
S. Cárcel,
S. Cebrián,
A. Cervera,
C. A. N. Conde,
T. Dafni,
J. Díaz,
R. Esteve,
L. M. P. Fernandes,
A. L. Ferreira,
E. D. C. Freitas,
V. M. Gehman,
A. Goldschmidt,
H. Gómez,
D. González-Díaz,
R. M. Gutiérrez,
J. Hauptman
, et al. (41 additional authors not shown)
Abstract:
The NEXT experiment aims to observe the neutrinoless double beta decay of $^{136}$Xe in a high pressure gas TPC using electroluminescence (EL) to amplify the signal from ionization. Understanding the response of the detector is imperative in achieving a consistent and well understood energy measurement. The abundance of xenon k-shell x-ray emission during data taking has been identified as a multi…
▽ More
The NEXT experiment aims to observe the neutrinoless double beta decay of $^{136}$Xe in a high pressure gas TPC using electroluminescence (EL) to amplify the signal from ionization. Understanding the response of the detector is imperative in achieving a consistent and well understood energy measurement. The abundance of xenon k-shell x-ray emission during data taking has been identified as a multitool for the characterisation of the fundamental parameters of the gas as well as the equalisation of the response of the detector. The NEXT-DEMO prototype is a ~1.5 kg volume TPC filled with natural xenon. It employs an array of 19 PMTs as an energy plane and of 256 SiPMs as a tracking plane with the TPC light tube and SiPM surfaces being coated with tetraphenyl butadiene (TPB) which acts as a wavelength shifter for the VUV scintillation light produced by xenon. This paper presents the measurement of the properties of the drift of electrons in the TPC, the effects of the EL production region, and the extraction of position dependent correction constants using K$_α$ X-ray deposits. These constants were used to equalise the response of the detector to deposits left by gammas from $^{22}$Na.
△ Less
Submitted 5 November, 2014; v1 submitted 15 July, 2014;
originally announced July 2014.
-
Ionization and scintillation response of high-pressure xenon gas to alpha particles
Authors:
NEXT Collaboration,
V. Álvarez,
F. I. G. M. Borges,
S. Cárcel,
S. Cebrián,
A. Cervera,
C. A. N. Conde,
T. Dafni,
J. Díaz,
M. Egorov,
R. Esteve,
P. Evtoukhovitch,
L. M. P. Fernandes,
P. Ferrario,
A. L. Ferreira,
E. D. C. Freitas,
V. M. Gehman,
A. Gil,
A. Goldschmidt,
H. Gómez,
J. J. Gómez-Cadenas,
D. González-Díaz,
R. M. Gutiérrez,
J. Hauptman,
J. A. Hernando Morata
, et al. (48 additional authors not shown)
Abstract:
High-pressure xenon gas is an attractive detection medium for a variety of applications in fundamental and applied physics. In this paper we study the ionization and scintillation detection properties of xenon gas at 10 bar pressure. For this purpose, we use a source of alpha particles in the NEXT-DEMO time projection chamber, the large scale prototype of the NEXT-100 neutrinoless double beta deca…
▽ More
High-pressure xenon gas is an attractive detection medium for a variety of applications in fundamental and applied physics. In this paper we study the ionization and scintillation detection properties of xenon gas at 10 bar pressure. For this purpose, we use a source of alpha particles in the NEXT-DEMO time projection chamber, the large scale prototype of the NEXT-100 neutrinoless double beta decay experiment, in three different drift electric field configurations. We measure the ionization electron drift velocity and longitudinal diffusion, and compare our results to expectations based on available electron scattering cross sections on pure xenon. In addition, two types of measurements addressing the connection between the ionization and scintillation yields are performed. On the one hand we observe, for the first time in xenon gas, large event-by-event correlated fluctuations between the ionization and scintillation signals, similar to that already observed in liquid xenon. On the other hand, we study the field dependence of the average scintillation and ionization yields. Both types of measurements may shed light on the mechanism of electron-ion recombination in xenon gas for highly-ionizing particles. Finally, by comparing the response of alpha particles and electrons in NEXT-DEMO, we find no evidence for quenching of the primary scintillation light produced by alpha particles in the xenon gas.
△ Less
Submitted 21 May, 2013; v1 submitted 19 November, 2012;
originally announced November 2012.
-
Near-Intrinsic Energy Resolution for 30 to 662 keV Gamma Rays in a High Pressure Xenon Electroluminescent TPC
Authors:
NEXT Collaboration,
V. Álvarez,
F. I. G. M. Borges,
S. Cárcel,
J. Castel,
S. Cebrián,
A. Cervera,
C. A. N. Conde,
T. Dafni,
T. H. V. T. Dias,
J. Díaz,
M. Egorov,
R. Esteve,
P. Evtoukhovitch,
L. M. P. Fernandes,
P. Ferrario,
A. L. Ferreira,
E. D. C. Freitas,
V. M. Gehman,
A. Gil,
A. Goldschmidt,
H. Gómez,
J. J. Gómez-Cadenas,
D. González-Díaz,
R. M. Gutiérrez
, et al. (53 additional authors not shown)
Abstract:
We present the design, data and results from the NEXT prototype for Double Beta and Dark Matter (NEXT-DBDM) detector, a high-pressure gaseous natural xenon electroluminescent time projection chamber (TPC) that was built at the Lawrence Berkeley National Laboratory. It is a prototype of the planned NEXT-100 $^{136}$Xe neutrino-less double beta decay ($0νββ$) experiment with the main objectives of d…
▽ More
We present the design, data and results from the NEXT prototype for Double Beta and Dark Matter (NEXT-DBDM) detector, a high-pressure gaseous natural xenon electroluminescent time projection chamber (TPC) that was built at the Lawrence Berkeley National Laboratory. It is a prototype of the planned NEXT-100 $^{136}$Xe neutrino-less double beta decay ($0νββ$) experiment with the main objectives of demonstrating near-intrinsic energy resolution at energies up to 662 keV and of optimizing the NEXT-100 detector design and operating parameters. Energy resolutions of $\sim$1% FWHM for 662 keV gamma rays were obtained at 10 and 15 atm and $\sim$5% FWHM for 30 keV fluorescence xenon X-rays. These results demonstrate that 0.5% FWHM resolutions for the 2,459 keV hypothetical neutrino-less double beta decay peak are realizable. This energy resolution is a factor 7 to 20 better than that of the current leading $0νββ$ experiments using liquid xenon and thus represents a significant advancement. We present also first results from a track imaging system consisting of 64 silicon photo-multipliers recently installed in NEXT-DBDM that, along with the excellent energy resolution, demonstrates the key functionalities required for the NEXT-100 $0νββ$ search.
△ Less
Submitted 19 November, 2012;
originally announced November 2012.
-
In-situ calibration of a PMT inside a scintillation detector by means of primary scintillation detection
Authors:
NEXT Collaboration,
V. Álvarez,
F. I. G. M. Borges,
S. Cárcel,
J. Castel,
S. Cebrián,
A. Cervera,
C. A. N. Conde,
T. Dafni,
T. H. V. T. Dias,
J. Díaz,
M. Egorov,
R. Esteve,
P. Evtoukhovitch,
L. M. P. Fernandes,
P. Ferrario,
A. L. Ferreira,
E. D. C. Freitas,
V. M. Gehman,
A. Gil,
A. Goldschmidt,
H. Gómez,
J. J. Gómez-Cadenas,
D. González-Díaz,
R. M. Gutiérrez
, et al. (53 additional authors not shown)
Abstract:
We have investigated the possibility of calibrating the PMTs of scintillation detectors, using the primary scintillation produced by X-rays to induce single photoelectron response of the PMT. The high-energy tail of this response, can be approximated to an exponential function, under some conditions. In these cases, it is possible to determine the average gain for each PMT biasing voltage from the…
▽ More
We have investigated the possibility of calibrating the PMTs of scintillation detectors, using the primary scintillation produced by X-rays to induce single photoelectron response of the PMT. The high-energy tail of this response, can be approximated to an exponential function, under some conditions. In these cases, it is possible to determine the average gain for each PMT biasing voltage from the inverse of the exponent of the exponential fit to the tail, which can be done even if the background and/or noise cover-up most of the distribution. We have compared our results with those obtained by the commonly used single electron response (SER) method, which uses a LED to induce a single photoelectron response of the PMT and determines the peak position of such response, relative to the pedestal peak (the electronic noise peak, which corresponds to 0 photoelectrons). The results of the exponential fit method agree with those obtained by the SER method when the average number of photoelectrons reaching the first dynode per light/scintillation pulse is around 1.0. The SER method has higher precision, while the exponential fit method has the advantage of being useful in situations where the PMT is already in situ, being difficult or even impossible to apply the SER method, e.g. in sealed scintillator/PMT devices.
△ Less
Submitted 19 November, 2012;
originally announced November 2012.
-
Design and characterization of the SiPM tracking system of NEXT-DEMO, a demonstrator prototype of the NEXT-100 experiment
Authors:
NEXT Collaboration,
V. Álvarez,
M. Ball,
F. I. G. M. Borges,
S. Cárcel,
J. M. Carmona,
J. Castel,
J. M. Catalá,
S. Cebrián,
A. Cervera,
D. Chan,
C. A. N. Conde,
T. Dafni,
T. H. V. T. Dias,
J. Díaz,
M. Egorov,
R. Esteve,
P. Evtoukhovitch,
L. M. P. Fernandes,
P. Ferrario,
A. L. Ferreira,
E. Ferrer-Ribas,
E. D. C. Freitas,
A. N. C. Garcia,
V. M. Gehman
, et al. (64 additional authors not shown)
Abstract:
NEXT-100 experiment aims at searching the neutrinoless double-beta decay of the Xe-136 isotope using a TPC filled with a 100 kg of high-pressure gaseous xenon, with 90% isotopic enrichment. The experiment will take place at the Laboratorio Subterráneo de Canfranc (LSC), Spain. NEXT-100 uses electroluminescence (EL) technology for energy measurement with a resolution better than 1% FWHM. The gaseou…
▽ More
NEXT-100 experiment aims at searching the neutrinoless double-beta decay of the Xe-136 isotope using a TPC filled with a 100 kg of high-pressure gaseous xenon, with 90% isotopic enrichment. The experiment will take place at the Laboratorio Subterráneo de Canfranc (LSC), Spain. NEXT-100 uses electroluminescence (EL) technology for energy measurement with a resolution better than 1% FWHM. The gaseous xenon in the TPC additionally allows the tracks of the two beta particles to be recorded, which are expected to have a length of up to 30 cm at 10 bar pressure. The ability to record the topological signature of the neutrinoless double-beta events provides a powerful background rejection factor for the double-beta experiment.
In this paper, we present a novel 3D imaging concept using SiPMs coated with tetraphenyl butadiene (TPB) for the EL read out and its first implementation in NEXT-DEMO, a large-scale prototype of the NEXT-100 experiment. The design and the first characterization measurements of the NEXT-DEMO SiPM tracking system are presented. The SiPM response uniformity over the tracking plane drawn from its gain map is shown to be better than 4%. An automated active control system for the stabilization of the SiPMs gain was developed, based on the voltage supply compensation of the gain drifts. The gain is shown to be stabilized within 0.2% relative variation around its nominal value, provided by Hamamatsu, in a temperature range of 10 degree C. The noise level from the electronics and the SiPM dark noise is shown to lay typically below the level of 10 photoelectrons (pe) in the ADC. Hence, a detection threshold at 10 pe is set for the acquisition of the tracking signals. The ADC full dynamic range (4096 channels) is shown to be adequate for signal levels of up to 200 pe/microsecond, which enables recording most of the tracking signals.
△ Less
Submitted 22 February, 2013; v1 submitted 27 June, 2012;
originally announced June 2012.
-
Simulation of VUV electroluminescence in micropattern gaseous detectors: the case of GEM and MHSP
Authors:
C. A. B. Oliveira,
P. M. M. Correia,
H. Schindler,
A. L. Ferreira,
C. M. B. Monteiro,
J. M. F. dos Santos,
S. Biagi,
R. Veenhof,
J. F. C. A. Veloso
Abstract:
Electroluminescence produced during avalanche development in gaseous avalanche detectors is an useful information for triggering, calorimetry and tracking in gaseous detectors. Noble gases present high electroluminescence yields, emitting mainly in the VUV region. The photons can provide signal readout if appropriate photosensors are used. Micropattern gaseous detectors are good candidates for sig…
▽ More
Electroluminescence produced during avalanche development in gaseous avalanche detectors is an useful information for triggering, calorimetry and tracking in gaseous detectors. Noble gases present high electroluminescence yields, emitting mainly in the VUV region. The photons can provide signal readout if appropriate photosensors are used. Micropattern gaseous detectors are good candidates for signal amplification in high background and/or low rate experiments due to their high electroluminescence yields and radiopurity. In this work, the VUV light responses of the Gas Electron Multiplier and of the Micro-Hole Strip Plate, working with pure xenon, are simulated and studied in detail using a new and versatile C++ toolkit. It is shown that the solid angle subtended by a photosensor placed below the microstructures depends on the operating conditions. The obtained absolute EL yields, determined for different gas pressures and as functions of the applied voltage, are compared with those determined experimentally.
△ Less
Submitted 30 July, 2012; v1 submitted 7 June, 2012;
originally announced June 2012.
-
NEXT-100 Technical Design Report (TDR). Executive Summary
Authors:
NEXT Collaboration,
V. Álvarez,
F. I. G. M. Borges,
S. Cárcel,
J. M. Carmona,
J. Castel,
J. M. Catalá,
S. Cebrián,
A. Cervera,
D. Chan,
C. A. N. Conde,
T. Dafni,
T. H. V. T. Dias,
J. Díaz,
M. Egorov,
R. Esteve,
P. Evtoukhovitch,
L. M. P. Fernandes,
P. Ferrario,
A. L. Ferreira,
E. Ferrer-Ribas,
E. D. C. Freitas,
V. M. Gehman,
A. Gil,
I. Giomataris
, et al. (62 additional authors not shown)
Abstract:
In this Technical Design Report (TDR) we describe the NEXT-100 detector that will search for neutrinoless double beta decay (bbonu) in Xe-136 at the Laboratorio Subterraneo de Canfranc (LSC), in Spain. The document formalizes the design presented in our Conceptual Design Report (CDR): an electroluminescence time projection chamber, with separate readout planes for calorimetry and tracking, located…
▽ More
In this Technical Design Report (TDR) we describe the NEXT-100 detector that will search for neutrinoless double beta decay (bbonu) in Xe-136 at the Laboratorio Subterraneo de Canfranc (LSC), in Spain. The document formalizes the design presented in our Conceptual Design Report (CDR): an electroluminescence time projection chamber, with separate readout planes for calorimetry and tracking, located, respectively, behind cathode and anode. The detector is designed to hold a maximum of about 150 kg of xenon at 15 bar, or 100 kg at 10 bar. This option builds in the capability to increase the total isotope mass by 50% while kee** the operating pressure at a manageable level.
The readout plane performing the energy measurement is composed of Hamamatsu R11410-10 photomultipliers, specially designed for operation in low-background, xenon-based detectors. Each individual PMT will be isolated from the gas by an individual, pressure resistant enclosure and will be coupled to the sensitive volume through a sapphire window. The tracking plane consists in an array of Hamamatsu S10362-11-050P MPPCs used as tracking pixels. They will be arranged in square boards holding 64 sensors (8 times8) with a 1-cm pitch. The inner walls of the TPC, the sapphire windows and the boards holding the MPPCs will be coated with tetraphenyl butadiene (TPB), a wavelength shifter, to improve the light collection.
△ Less
Submitted 16 April, 2012; v1 submitted 3 February, 2012;
originally announced February 2012.
-
SiPMs coated with TPB : coating protocol and characterization for NEXT
Authors:
V. Álvarez,
J. Agramunt,
M. Ball,
M. Batallé,
J. Bayarri,
F. I. G. Borges,
H. Bolink,
H. Brine,
S. Cárcel,
J. M. Carmona,
J. Castel,
J. M. Catalá,
S. Cebrián,
A. Cervera,
D. Chan,
C. A. N. Conde,
T. Dafni,
T. H. V. T. Dias,
J. Díaz,
R. Esteve,
P. Evtoukhovitch,
J. Ferrando,
L. M. P. Fernandes,
P. Ferrario,
A. L. Ferreira
, et al. (69 additional authors not shown)
Abstract:
Silicon photomultipliers (SiPM) are the photon detectors chosen for the tracking readout in NEXT, a neutrinoless ββ decay experiment which uses a high pressure gaseous xenon time projection chamber (TPC). The reconstruction of event track and topology in this gaseous detector is a key handle for background rejection. Among the commercially available sensors that can be used for tracking, SiPMs off…
▽ More
Silicon photomultipliers (SiPM) are the photon detectors chosen for the tracking readout in NEXT, a neutrinoless ββ decay experiment which uses a high pressure gaseous xenon time projection chamber (TPC). The reconstruction of event track and topology in this gaseous detector is a key handle for background rejection. Among the commercially available sensors that can be used for tracking, SiPMs offer important advantages, mainly high gain, ruggedness, cost-effectiveness and radio-purity. Their main drawback, however, is their non sensitivity in the emission spectrum of the xenon scintillation (peak at 175 nm). This is overcome by coating these sensors with the organic wavelength shifter tetraphenyl butadienne (TPB). In this paper we describe the protocol developed for coating the SiPMs with TPB and the measurements performed for characterizing the coatings as well as the performance of the coated sensors in the UV-VUV range.
△ Less
Submitted 10 January, 2012;
originally announced January 2012.
-
The NEXT-100 experiment for neutrinoless double beta decay searches (Conceptual Design Report)
Authors:
NEXT Collaboration,
V. Álvarez,
M. Ball,
M. Batallé,
J. Bayarri,
F. I. G. Borges,
S. Cárcel,
J. M. Carmona,
J. Castel,
J. M. Catalá,
S. Cebrián,
A. Cervera-Villanueva,
D. Chan,
C. A. N. Conde,
T. Dafni,
T. H. V. T. Dias,
J. Díaz,
R. Esteve,
P. Evtoukhovitch,
L. M. P. Fernandes,
P. Ferrario,
E. Ferrer-Ribas,
A. L. Ferreira,
E. D. C. Freitas,
A. Gil
, et al. (58 additional authors not shown)
Abstract:
We propose an EASY (Electroluminescent ApparatuS of high Yield) and SOFT (Separated Optimized FuncTion) time-projection chamber for the NEXT experiment, that will search for neutrinoless double beta decay (bb0nu) in Xe-136. Our experiment must be competitive with the new generation of bb0nu searches already in operation or in construction. This requires a detector with very good energy resolution…
▽ More
We propose an EASY (Electroluminescent ApparatuS of high Yield) and SOFT (Separated Optimized FuncTion) time-projection chamber for the NEXT experiment, that will search for neutrinoless double beta decay (bb0nu) in Xe-136. Our experiment must be competitive with the new generation of bb0nu searches already in operation or in construction. This requires a detector with very good energy resolution (<1%), very low background con- tamination (1E-4 counts/(keV \bullet kg \bullet y)) and large target mass. In addition, it needs to be operational as soon as possible. The design described here optimizes energy resolution thanks to the use of proportional electroluminescent amplification (EL); it is compact, as the Xe gas is under high pressure; and it allows the measurement of the topological signature of the event to further reduce the background contamination. The SOFT design uses different sensors for tracking and calorimetry. We propose the use of SiPMs (MPPCs) coated with a suitable wavelength shifter for the tracking, and the use of radiopure photomultipliers for the measurement of the energy and the primary scintillation needed to estimate the t0. This design provides the best possible energy resolution compared with other NEXT designs based on avalanche gain devices. The baseline design is an Asymmetric Neutrino Gas EL apparatus (ANGEL), which was already outlined in the NEXT LOI. ANGEL is conceived to be easy to fabricate. It requires very little R&D and most of the proposed solutions have already been tested in the NEXT-1 prototypes. Therefore, the detector can be ready by 2013. In this Conceptual Design Report (CDR) we discuss first the physics case, present a full design of the detector, describe the NEXT-1 EL prototypes and their initial results, and outline a project to build a detector with 100 kg of enriched xenon to be installed in the Canfranc Underground Laboratory in 2013.
△ Less
Submitted 18 June, 2011;
originally announced June 2011.
-
A simulation toolkit for electroluminescence assessment in rare event experiments
Authors:
C. A. B. Oliveira,
H. Schindler,
R. Veenhof,
S. Biagi,
C. M. B. Monteiro,
J. M. F. dos Santos,
A. L. Ferreira,
J. F. C. A. Veloso
Abstract:
A good understanding of electroluminescence is a prerequisite when optimising double-phase noble gas detectors for Dark Matter searches and high-pressure xenon TPCs for neutrinoless double beta decay detection.
A simulation toolkit for calculating the emission of light through electron impact on neon, argon, krypton and xenon has been developed using the Magboltz and Garfield programs. Calculate…
▽ More
A good understanding of electroluminescence is a prerequisite when optimising double-phase noble gas detectors for Dark Matter searches and high-pressure xenon TPCs for neutrinoless double beta decay detection.
A simulation toolkit for calculating the emission of light through electron impact on neon, argon, krypton and xenon has been developed using the Magboltz and Garfield programs. Calculated excitation and electroluminescence efficiencies, electroluminescence yield and associated statistical fluctuations are presented as a function of electric field. Good agreement with experiment and with Monte Carlo simulations has been obtained.
△ Less
Submitted 31 March, 2011;
originally announced March 2011.
-
NEXT, a HPGXe TPC for neutrinoless double beta decay searches
Authors:
The NEXT Collaboration,
F. Granena,
T. Lux,
F. Nova,
J. Rico,
F. Sanchez,
D. R. Nygren,
J. A. S. Barata,
F. I. G. M. Borges,
C. A. N. Conde,
T. H. V. T. Dias,
L. M. P. Fernandes,
E. D. C. Freitas,
J. A. M. Lopes,
C. M. B. Monteiro,
J. M. F. dos Santos,
F. P. Santos,
L. M. N. Tavora,
J. F. C. A. Veloso,
E. Calvo,
I. Gil-Botella,
P. Novella,
C. Palomares,
A. Verdugo,
I. Giomataris
, et al. (39 additional authors not shown)
Abstract:
We propose a novel detection concept for neutrinoless double-beta decay searches. This concept is based on a Time Projection Chamber (TPC) filled with high-pressure gaseous xenon, and with separated-function capabilities for calorimetry and tracking. Thanks to its excellent energy resolution, together with its powerful background rejection provided by the distinct double-beta decay topological s…
▽ More
We propose a novel detection concept for neutrinoless double-beta decay searches. This concept is based on a Time Projection Chamber (TPC) filled with high-pressure gaseous xenon, and with separated-function capabilities for calorimetry and tracking. Thanks to its excellent energy resolution, together with its powerful background rejection provided by the distinct double-beta decay topological signature, the design discussed in this Letter Of Intent promises to be competitive and possibly out-perform existing proposals for next-generation neutrinoless double-beta decay experiments. We discuss the detection principles, design specifications, physics potential and R&D plans to construct a detector with 100 kg fiducial mass in the double-beta decay emitting isotope Xe(136), to be installed in the Canfranc Underground Laboratory.
△ Less
Submitted 22 July, 2009;
originally announced July 2009.