-
Study on the radon adsorption capability of low-background activated carbon
Authors:
Chi Li,
Yongpeng Zhang,
Lidan Lv,
**chang Liu,
Cong Guo,
Changgen Yang,
Tingyu Guan,
Yu Liu,
Yu Lei,
Quan Tang
Abstract:
Radon is a significant background source in rare event detection experiments. Activated Carbon (AC) adsorption is widely used for effective radon removal. The selection of AC considers its adsorption capacity and radioactive background. In this study, using self-developed devices, we screened and identified a new kind of low-background AC from Qingdao Inaf Technology Company that has very high Rad…
▽ More
Radon is a significant background source in rare event detection experiments. Activated Carbon (AC) adsorption is widely used for effective radon removal. The selection of AC considers its adsorption capacity and radioactive background. In this study, using self-developed devices, we screened and identified a new kind of low-background AC from Qingdao Inaf Technology Company that has very high Radon adsorption capacity. By adjusting the average pore size to 2.3 nm, this AC demonstrates a radon adsorption capacity of 2.6 or 4.7 times higher than Saratech or Carboact activated carbon under the same conditions.
△ Less
Submitted 22 October, 2023;
originally announced October 2023.
-
Limits on light WIMPs from the CDEX-1 experiment with a p-type point-contact germanium detector at the China **g** Underground Laboratory
Authors:
Q. Yue,
W. Zhao,
K. J. Kang,
J. P. Cheng,
Y. J. Li,
S. T. Lin,
J. P. Chang,
N. Chen,
Q. H. Chen,
Y. H. Chen,
Y. C. Chuang,
Z. Deng,
Q. Du,
H. Gong,
X. Q. Hao,
H. J. He,
Q. J. He,
H. X. Huang,
T. R. Huang,
H. Jiang,
H. B. Li,
J. M. Li,
J. Li,
J. Li,
X. Li
, et al. (49 additional authors not shown)
Abstract:
We report results of a search for light Dark Matter WIMPs with CDEX-1 experiment at the China **** Underground Laboratory, based on 53.9 kg-days of data from a p-type point-contact germanium detector enclosed by a NaI(Tl) crystal scintillator as anti-Compton detector. The event rate and spectrum above the analysis threshold of 475 eVee are consistent with the understood background model. Part o…
▽ More
We report results of a search for light Dark Matter WIMPs with CDEX-1 experiment at the China **** Underground Laboratory, based on 53.9 kg-days of data from a p-type point-contact germanium detector enclosed by a NaI(Tl) crystal scintillator as anti-Compton detector. The event rate and spectrum above the analysis threshold of 475 eVee are consistent with the understood background model. Part of the allowed regions for WIMP-nucleus coherent elastic scattering at WIMP mass of 6-20 GeV are probed and excluded. Independent of interaction channels, this result contradicts the interpretation that the anomalous excesses of the CoGeNT experiment are induced by Dark Matter, since identical detector techniques are used in both experiments.
△ Less
Submitted 10 November, 2014; v1 submitted 19 April, 2014;
originally announced April 2014.
-
First results on low-mass WIMP from the CDEX-1 experiment at the China **** underground Laboratory
Authors:
W. Zhao,
Q. Yue,
K. J. Kang,
J. P. Cheng,
Y. J. Li,
S. T. Lin,
Y. Bai,
Y. Bi,
J. P. Chang,
N. Chen,
N. Chen,
Q. H. Chen,
Y. H. Chen,
Y. C. Chuang,
Z. Deng,
C. Du,
Q. Du,
H. Gong,
X. Q. Hao,
H. J. He,
Q. J. He,
X. H. Hu,
H. X. Huang,
T. R. Huang,
H. Jiang
, et al. (54 additional authors not shown)
Abstract:
The China Dark matter Experiment collaboration reports the first experimental limit on WIMP dark matter from 14.6 kg-day of data taken with a 994 g p-type point-contact germanium detector at the China **** underground Laboratory where the rock overburden is more than 2400 m. The energy threshold achieved was 400 eVee. According to the 14.6 kg-day live data, we placed the limit of N= 1.75 * 10^{…
▽ More
The China Dark matter Experiment collaboration reports the first experimental limit on WIMP dark matter from 14.6 kg-day of data taken with a 994 g p-type point-contact germanium detector at the China **** underground Laboratory where the rock overburden is more than 2400 m. The energy threshold achieved was 400 eVee. According to the 14.6 kg-day live data, we placed the limit of N= 1.75 * 10^{-40} cm^{2} at 90% confidence level on the spin-independent cross-section at WIMP mass of 7 GeV before differentiating bulk signals from the surface backgrounds.
△ Less
Submitted 8 August, 2013; v1 submitted 18 June, 2013;
originally announced June 2013.
-
The CDEX-1 1 kg Point-Contact Germanium Detector for Low Mass Dark Matter Searches
Authors:
Ke-Jun Kang,
Qian Yue,
Yu-Cheng Wu,
Jian-** Cheng,
Yuan-**g Li,
Yang Bai,
Yong Bi,
Jian-** Chang,
Nan Chen,
Ning Chen,
Qing-Hao Chen,
Yun-Hua Chen,
You-Chun Chuang,
Zhi Dend,
Qiang Du,
Hui Gong,
Xi-Qing Hao,
Qing-Ju He,
Xin-Hui Hu,
Han-Xiong Huang,
Teng-Rui Huang,
Hao Jiang,
Hau-Bin Li,
Jian-Min Li,
** Li
, et al. (51 additional authors not shown)
Abstract:
The CDEX Collaboration has been established for direct detection of light dark matter particles, using ultra-low energy threshold p-type point-contact germanium detectors, in China **** underground Laboratory (CJPL). The first 1 kg point-contact germanium detector with a sub-keV energy threshold has been tested in a passive shielding system located in CJPL. The outputs from both the point-conta…
▽ More
The CDEX Collaboration has been established for direct detection of light dark matter particles, using ultra-low energy threshold p-type point-contact germanium detectors, in China **** underground Laboratory (CJPL). The first 1 kg point-contact germanium detector with a sub-keV energy threshold has been tested in a passive shielding system located in CJPL. The outputs from both the point-contact p+ electrode and the outside n+ electrode make it possible to scan the lower energy range of less than 1 keV and at the same time to detect the higher energy range up to 3 MeV. The outputs from both p+ and n+ electrode may also provide a more powerful method for signal discrimination for dark matter experiment. Some key parameters, including energy resolution, dead time, decay times of internal X-rays, and system stability, have been tested and measured. The results show that the 1 kg point-contact germanium detector, together with its shielding system and electronics, can run smoothly with good performances. This detector system will be deployed for dark matter search experiments.
△ Less
Submitted 2 May, 2013;
originally announced May 2013.
-
GeV Scale Asymmetric Dark Matter from Mirror Universe: Direct Detection and LHC Signatures
Authors:
Jian-Wei Cui,
Hong-Jian He,
Lan-Chun Lv,
Fu-Rong Yin
Abstract:
Mirror universe is a fundamental way to restore parity symmetry in weak interactions. It naturally provides the lightest mirror nucleon as a unique GeV-scale asymmetric dark matter particle candidate. We conjecture that the mirror parity is respected by the fundamental interaction Lagrangian, and its possible soft breaking arises only from non-interaction terms in the gauge-singlet sector. We real…
▽ More
Mirror universe is a fundamental way to restore parity symmetry in weak interactions. It naturally provides the lightest mirror nucleon as a unique GeV-scale asymmetric dark matter particle candidate. We conjecture that the mirror parity is respected by the fundamental interaction Lagrangian, and its possible soft breaking arises only from non-interaction terms in the gauge-singlet sector. We realize the spontaneous mirror parity violation by minimizing the vacuum Higgs potential, and derive the corresponding Higgs spectrum. We demonstrate that the common origin of CP violation in the visible and mirror neutrino seesaws can generate the right amount of matter and mirror dark matter via leptogenesis. We analyze the direct detections of GeV-scale mirror dark matter by TEXONO and CDEX experiments. We further study the predicted distinctive Higgs signatures at the LHC.
△ Less
Submitted 7 March, 2012; v1 submitted 5 March, 2012;
originally announced March 2012.
-
Spontaneous Mirror Parity Violation, Common Origin of Matter and Dark Matter, and the LHC Signatures
Authors:
Jian-Wei Cui,
Hong-Jian He,
Lan-Chun Lv,
Fu-Rong Yin
Abstract:
Existence of a mirror world in the universe is a fundamental way to restore the observed parity violation in weak interactions and provides the lightest mirror nucleon as a unique GeV-scale dark matter particle candidate. The visible and mirror worlds share the same spacetime of the universe and are connected by a unique space-inversion symmetry -- the mirror parity (P). We conjecture that the mir…
▽ More
Existence of a mirror world in the universe is a fundamental way to restore the observed parity violation in weak interactions and provides the lightest mirror nucleon as a unique GeV-scale dark matter particle candidate. The visible and mirror worlds share the same spacetime of the universe and are connected by a unique space-inversion symmetry -- the mirror parity (P). We conjecture that the mirror parity is respected by the fundamental interaction Lagrangian, and study its spontaneous breaking from minimizing the Higgs vacuum potential. The domain wall problem is resolved by a unique soft breaking linear-term from the P-odd weak-singlet Higgs field. We also derive constraint from the Big-Bang nucleosynthesis. We then analyze the neutrino seesaw for both visible and mirror worlds, and demonstrate that the desired amounts of visible matter and mirror dark matter in the universe arise from a common origin of CP violation in the neutrino sector via leptogenesis. We derive the Higgs mass-spectrum and Higgs couplings with gauge bosons and fermions. We show their consistency with the direct Higgs searches and the indirect precision constraints. We further study the distinctive signatures of the predicted non-standard Higgs bosons at the LHC. Finally, we analyze the direct detections of GeV-scale mirror dark matter by TEXONO and CDEX experiments.
△ Less
Submitted 7 March, 2012; v1 submitted 31 October, 2011;
originally announced October 2011.