ETROC1: The First Full Chain Precision Timing Prototype ASIC for CMS MTD Endcap Timing Layer Upgrade
Authors:
Xing Huang,
Quan Sun,
Datao Gong,
Piljun Gwak,
Doyeong Kim,
Jongho Lee,
Chonghan Liu,
Tiankuan Liu,
Tiehui Liu,
Sergey Los,
Sandeep Miryala,
Shirsendu Nanda,
Jamieson Olsen,
Hanhan Sun,
**yuan Wu,
**gbo Ye,
Zhenyu Ye,
Li Zhang,
Wei Zhang
Abstract:
We present the design and characterization of the first full chain precision timing prototype ASIC, named ETL Readout Chip version 1 (ETROC1) for the CMS MTD endcap timing layer (ETL) upgrade. The ETL utilizes Low Gain Avalanche Diode (LGAD) sensors to detect charged particles, with the goal to achieve a time resolution of 40 - 50 ps per hit, and 30 - 40 ps per track with hits from two detector la…
▽ More
We present the design and characterization of the first full chain precision timing prototype ASIC, named ETL Readout Chip version 1 (ETROC1) for the CMS MTD endcap timing layer (ETL) upgrade. The ETL utilizes Low Gain Avalanche Diode (LGAD) sensors to detect charged particles, with the goal to achieve a time resolution of 40 - 50 ps per hit, and 30 - 40 ps per track with hits from two detector layers. The ETROC1 is composed of a 5 x 5 pixel array and peripheral circuits. The pixel array includes a 4 x 4 active pixel array with an H-tree shaped network delivering clock and charge injection signals. Each active pixel is composed of various components, including a bump pad, a charge injection circuit, a pre-amplifier, a discriminator, a digital-to-analog converter, and a time-to-digital converter. These components play essential roles as the front-end link in processing LGAD signals and measuring timing-related information. The peripheral circuits provide clock signals and readout functionalities. The size of the ETROC1 chip is 7 mm x 9 mm. ETROC1 has been fabricated in a 65 nm CMOS process, and extensively tested under stimuli of charge injection, infrared laser, and proton beam. The time resolution of bump-bonded ETROC1 + LGAD chipsets reaches 42 - 46 ps per hit in the beam test.
△ Less
Submitted 25 April, 2024; v1 submitted 22 April, 2024;
originally announced April 2024.
-
Design and performance of the Fermilab Constant Fraction Discriminator ASIC
Authors:
Si Xie,
Artur Apresyan,
Ryan Heller,
Christopher Madrid,
Irene Dutta,
Aram Hayrapetyan,
Sergey Los,
Cristian Pena,
Tom Zimmerman
Abstract:
We present the design and performance characterization results of the novel Fermilab Constant Fraction Discriminator ASIC (FCFD) developed to readout low gain avalanche detector (LGAD) signals by directly using a constant fraction discriminator (CFD) to measure signal arrival time. Silicon detectors with time resolutions less than 30 ps will play a critical role in future collider experiments, and…
▽ More
We present the design and performance characterization results of the novel Fermilab Constant Fraction Discriminator ASIC (FCFD) developed to readout low gain avalanche detector (LGAD) signals by directly using a constant fraction discriminator (CFD) to measure signal arrival time. Silicon detectors with time resolutions less than 30 ps will play a critical role in future collider experiments, and LGADs have been demonstrated to provide the required time resolution and radiation tolerance for many such applications. The FCFD has a specially designed discriminator that is robust against amplitude variations of the signal from the LGAD that normally requires an additional correction step when using a traditional leading edge discriminator based measurement. The application of the CFD directly in the ASIC promises to be more reliable and reduces the complication of timing detectors during their operation. We will present a summary of the measured performance of the FCFD for input signals generated by internal charge injection, LGAD signals from an infrared laser, and LGAD signals from minimum-ionizing particles. The mean time response for a wide range of LGAD signal amplitudes has been measured to vary no more than 15 ps, orders of magnitude more stable than an uncorrected leading edge discriminator based measurement, and effectively removes the need for any additional time-walk correction. The measured contribution to the time resolution from the FCFD ASIC is also found to be 10 ps for signals with charge above 20 fC.
△ Less
Submitted 12 June, 2023;
originally announced June 2023.
-
The Analog Front-end for the LGAD Based Precision Timing Application in CMS ETL
Authors:
Quan Sun,
Sunil M. Dogra,
Christopher Edwards,
Datao Gong,
Lindsey Gray,
Xing Huang,
Siddhartha Joshi,
Jongho Lee,
Chonghan Liu,
Tiehui Liu,
Tiankuan Liu,
Sergey Los,
Chang-Seong Moon,
Geonhee Oh,
Jamieson Olsen,
Luciano Ristori,
Hanhan Sun,
Xiao Wang,
**yuan Wu,
**gbo Ye,
Zhenyu Ye,
Li Zhang,
Wei Zhang
Abstract:
The analog front-end for the Low Gain Avalanche Detector (LGAD) based precision timing application in the CMS Endcap Timing Layer (ETL) has been prototyped in a 65 nm CMOS mini-ASIC named ETROC0. Serving as the very first prototype of ETL readout chip (ETROC), ETROC0 aims to study and demonstrate the performance of the analog frontend, with the goal to achieve 40 to 50 ps time resolution per hit w…
▽ More
The analog front-end for the Low Gain Avalanche Detector (LGAD) based precision timing application in the CMS Endcap Timing Layer (ETL) has been prototyped in a 65 nm CMOS mini-ASIC named ETROC0. Serving as the very first prototype of ETL readout chip (ETROC), ETROC0 aims to study and demonstrate the performance of the analog frontend, with the goal to achieve 40 to 50 ps time resolution per hit with LGAD (therefore reach about 30ps per track with two detector-layer hits per track). ETROC0 consists of preamplifier and discriminator stages, which amplifies the LGAD signal and generates digital pulses containing time of arrival and time over threshold information. This paper will focus on the design considerations that lead to the ETROC front-end architecture choice, the key design features of the building blocks, the methodology of using the LGAD simulation data to evaluate and optimize the front-end design. The ETROC0 prototype chips have been extensively tested using charge injection and the measured performance agrees well with simulation. The initial beam test results are also presented, with time resolution of around 33 ps observed from the preamplifier waveform analysis and around 41 ps from the discriminator pulses analysis. A subset of ETROC0 chips have also been tested to a total ionizing dose of 100 MRad with X-ray and no performance degradation been observed.
△ Less
Submitted 28 December, 2020;
originally announced December 2020.
-
Test Beam Performance Measurements for the Phase I Upgrade of the CMS Pixel Detector
Authors:
M. Dragicevic,
M. Friedl,
J. Hrubec,
H. Steininger,
A. Gädda,
J. Härkönen,
T. Lampén,
P. Luukka,
T. Peltola,
E. Tuominen,
E. Tuovinen,
A. Winkler,
P. Eerola,
T. Tuuva,
G. Baulieu,
G. Boudoul,
L. Caponetto,
C. Combaret,
D. Contardo,
T. Dupasquier,
G. Gallbit,
N. Lumb,
L. Mirabito,
S. Perries,
M. Vander Donckt
, et al. (462 additional authors not shown)
Abstract:
A new pixel detector for the CMS experiment was built in order to cope with the instantaneous luminosities anticipated for the Phase~I Upgrade of the LHC. The new CMS pixel detector provides four-hit tracking with a reduced material budget as well as new cooling and powering schemes. A new front-end readout chip mitigates buffering and bandwidth limitations, and allows operation at low comparator…
▽ More
A new pixel detector for the CMS experiment was built in order to cope with the instantaneous luminosities anticipated for the Phase~I Upgrade of the LHC. The new CMS pixel detector provides four-hit tracking with a reduced material budget as well as new cooling and powering schemes. A new front-end readout chip mitigates buffering and bandwidth limitations, and allows operation at low comparator thresholds. In this paper, comprehensive test beam studies are presented, which have been conducted to verify the design and to quantify the performance of the new detector assemblies in terms of tracking efficiency and spatial resolution. Under optimal conditions, the tracking efficiency is $99.95\pm0.05\,\%$, while the intrinsic spatial resolutions are $4.80\pm0.25\,μ\mathrm{m}$ and $7.99\pm0.21\,μ\mathrm{m}$ along the $100\,μ\mathrm{m}$ and $150\,μ\mathrm{m}$ pixel pitch, respectively. The findings are compared to a detailed Monte Carlo simulation of the pixel detector and good agreement is found.
△ Less
Submitted 1 June, 2017;
originally announced June 2017.
-
Quartz Cherenkov Counters for Fast Timing: QUARTIC
Authors:
M. G. Albrow,
Heejong Kim,
S. Los,
E. Ramberg,
A. Ronzhin,
V. Samoylenko,
H. Wenzel,
A. Zatserklyaniy
Abstract:
We have developed particle detectors based on fused silica (quartz) Cherenkov radiators read out with micro-channel plate photomultipliers (MCP-PMTs) or silicon photomultipliers (SiPMs) for high precision timing (Sigma(t) about 10-15 ps). One application is to measure the times of small angle protons from exclusive reactions, e.g. p + p - p + H + p, at the Large Hadron Collider, LHC. They may also…
▽ More
We have developed particle detectors based on fused silica (quartz) Cherenkov radiators read out with micro-channel plate photomultipliers (MCP-PMTs) or silicon photomultipliers (SiPMs) for high precision timing (Sigma(t) about 10-15 ps). One application is to measure the times of small angle protons from exclusive reactions, e.g. p + p - p + H + p, at the Large Hadron Collider, LHC. They may also be used to measure directional particle fluxes close to external or stored beams. The detectors have small areas (square cm), but need to be active very close (a few mm) to the intense LHC beam, and so must be radiation hard and nearly edgeless. We present results of tests of detectors with quartz bars inclined at the Cherenkov angle, and with bars in the form of an "L" (with a 90 degree corner). We also describe a possible design for a fast timing hodoscope with elements of a few square mm.
△ Less
Submitted 3 December, 2012; v1 submitted 31 July, 2012;
originally announced July 2012.