-
Numerical Estimation of Primary Ionization with Noble Gases
Authors:
R. Kanishka
Abstract:
In high energy physics experiments, the numerical estimation of primary ionization is crucial. An advance study on primary ionization can help in minimizing the effects such as electrical discharges that can damage the gaseous detectors used in high energy physics experiments. The simulation of primary ionization of electrons and positrons with the noble gases using the geant4 toolkit have been pr…
▽ More
In high energy physics experiments, the numerical estimation of primary ionization is crucial. An advance study on primary ionization can help in minimizing the effects such as electrical discharges that can damage the gaseous detectors used in high energy physics experiments. The simulation of primary ionization of electrons and positrons with the noble gases using the geant4 toolkit have been presented. The obtained primaries have been separated from secondaries as the later contribute towards electrical discharges and further damage the detectors. The xenon gas shows highest primary ionization among the noble gases.
△ Less
Submitted 4 July, 2024; v1 submitted 25 May, 2024;
originally announced May 2024.
-
Numerical estimation of discharge probability in GEM-based detectors
Authors:
Prasant Kumar Rout,
R. Kanishka,
Jaydeep Datta,
Promita Roy,
Purba Bhattacharya,
Supratik Mukhopadhyay,
Nayana Majumdar,
Sandip Sarkar
Abstract:
Discharge probability in GEM-based gaseous detectors has been numerically estimated using an axisymmetric hydrodynamic model. Initial primary charge configurations in the drift region, obtained using Heed and Geant4, are found to have significant effect on the subsequent evolution of detector response. Simulation of energy resolution has been performed to establish the capability of the hydrodynam…
▽ More
Discharge probability in GEM-based gaseous detectors has been numerically estimated using an axisymmetric hydrodynamic model. Initial primary charge configurations in the drift region, obtained using Heed and Geant4, are found to have significant effect on the subsequent evolution of detector response. Simulation of energy resolution has been performed to establish the capability of the hydrodynamic model to capture statistical nature of the experimental situation. Finally, single and triple GEM configurations exposed to alpha sources have been simulated to estimate discharge probability which have been compared with available experimental data. Despite the simplifying and drastic assumptions in the numerical model, the comparisons are encouraging.
△ Less
Submitted 13 August, 2021; v1 submitted 23 March, 2021;
originally announced March 2021.
-
Optimisation and Characterisation of Glass RPC for India-based Neutrino Observatory Detectors
Authors:
R. Kanishka,
Vipin Bhatnagar,
D. Indumathi
Abstract:
The proposed magnetised Iron CALorimeter detector (ICAL) to be built in the India-based Neutrino Observatory (INO) laboratory aims to detect atmospheric muon neutrinos. In order to achieve improved physics results, the constituent components of the detector must be fully understood by proper characterisation and optimisation of various parameters. Resistive Plate Chambers (RPCs) are the active det…
▽ More
The proposed magnetised Iron CALorimeter detector (ICAL) to be built in the India-based Neutrino Observatory (INO) laboratory aims to detect atmospheric muon neutrinos. In order to achieve improved physics results, the constituent components of the detector must be fully understood by proper characterisation and optimisation of various parameters. Resistive Plate Chambers (RPCs) are the active detector elements in the ICAL detector and can be made of glass or bakelite. The number of RPCs required for this detector are very large so a detailed study is necessary to establish the characterisation and optimisation of these RPCs. These detectors once installed will be taking data for 15-20 years. In this paper, we report the selection criteria of the glass electrodes procured from Indian manufacturers. Based on the factors that deteriorate the quality of glass the choice of electrode is made. The glass characterisation studies include UV-VIS transmission for optical properties, SEM, AFM for surface properties, WD-XRF, PIXE for determining the composition of glass samples and electrical properties. Based on these techniques a procedure is adopted to arrive at the best glass sample. We have done a second order check on the quality of the fabricated glass RPCs. In this regard, the efficiency and cross-talk of RPCs were measured. Results from Asahi and Saint Gobain glass RPCs came out to be the best.
△ Less
Submitted 2 December, 2021; v1 submitted 30 May, 2016;
originally announced May 2016.
-
Physics Potential of the ICAL detector at the India-based Neutrino Observatory (INO)
Authors:
The ICAL Collaboration,
Shakeel Ahmed,
M. Sajjad Athar,
Rashid Hasan,
Mohammad Salim,
S. K. Singh,
S. S. R. Inbanathan,
Venktesh Singh,
V. S. Subrahmanyam,
Shiba Prasad Behera,
Vinay B. Chandratre,
Nitali Dash,
Vivek M. Datar,
V. K. S. Kashyap,
Ajit K. Mohanty,
Lalit M. Pant,
Animesh Chatterjee,
Sandhya Choubey,
Raj Gandhi,
Anushree Ghosh,
Deepak Tiwari,
Ali Ajmi,
S. Uma Sankar,
Prafulla Behera,
Aleena Chacko
, et al. (67 additional authors not shown)
Abstract:
The upcoming 50 kt magnetized iron calorimeter (ICAL) detector at the India-based Neutrino Observatory (INO) is designed to study the atmospheric neutrinos and antineutrinos separately over a wide range of energies and path lengths. The primary focus of this experiment is to explore the Earth matter effects by observing the energy and zenith angle dependence of the atmospheric neutrinos in the mul…
▽ More
The upcoming 50 kt magnetized iron calorimeter (ICAL) detector at the India-based Neutrino Observatory (INO) is designed to study the atmospheric neutrinos and antineutrinos separately over a wide range of energies and path lengths. The primary focus of this experiment is to explore the Earth matter effects by observing the energy and zenith angle dependence of the atmospheric neutrinos in the multi-GeV range. This study will be crucial to address some of the outstanding issues in neutrino oscillation physics, including the fundamental issue of neutrino mass hierarchy. In this document, we present the physics potential of the detector as obtained from realistic detector simulations. We describe the simulation framework, the neutrino interactions in the detector, and the expected response of the detector to particles traversing it. The ICAL detector can determine the energy and direction of the muons to a high precision, and in addition, its sensitivity to multi-GeV hadrons increases its physics reach substantially. Its charge identification capability, and hence its ability to distinguish neutrinos from antineutrinos, makes it an efficient detector for determining the neutrino mass hierarchy. In this report, we outline the analyses carried out for the determination of neutrino mass hierarchy and precision measurements of atmospheric neutrino mixing parameters at ICAL, and give the expected physics reach of the detector with 10 years of runtime. We also explore the potential of ICAL for probing new physics scenarios like CPT violation and the presence of magnetic monopoles.
△ Less
Submitted 9 May, 2017; v1 submitted 27 May, 2015;
originally announced May 2015.