-
Detecting Neutrinos from Supernova Bursts in PandaX-4T
Authors:
Binyu Pang,
Abdusalam Abdukerim,
Zihao Bo,
Wei Chen,
Xun Chen,
Chen Cheng,
Zhaokan Cheng,
Xiangyi Cui,
Yingjie Fan,
Deqing Fang,
Changbo Fu,
Mengting Fu,
Lisheng Geng,
Karl Giboni,
Linhui Gu,
Xuyuan Guo,
Chencheng Han,
Ke Han,
Changda He,
**rong He,
Di Huang,
Yanlin Huang,
Junting Huang,
Zhou Huang,
Ruquan Hou
, et al. (71 additional authors not shown)
Abstract:
Neutrinos from core-collapse supernovae are essential for the understanding of neutrino physics and stellar evolution. The dual-phase xenon dark matter detectors can provide a way to track explosions of galactic supernovae by detecting neutrinos through coherent elastic neutrino-nucleus scatterings. In this study, a variation of progenitor masses as well as explosion models are assumed to predict…
▽ More
Neutrinos from core-collapse supernovae are essential for the understanding of neutrino physics and stellar evolution. The dual-phase xenon dark matter detectors can provide a way to track explosions of galactic supernovae by detecting neutrinos through coherent elastic neutrino-nucleus scatterings. In this study, a variation of progenitor masses as well as explosion models are assumed to predict the neutrino fluxes and spectra, which result in the number of expected neutrino events ranging from 6.6 to 13.7 at a distance of 10 kpc over a 10-second duration with negligible backgrounds at PandaX-4T. Two specialized triggering alarms for monitoring supernova burst neutrinos are built. The efficiency of detecting supernova explosions at various distances in the Milky Way is estimated. These alarms will be implemented in the real-time supernova monitoring system at PandaX-4T in the near future, providing the astronomical communities with supernova early warnings.
△ Less
Submitted 10 March, 2024;
originally announced March 2024.
-
Signal Response Model in PandaX-4T
Authors:
Yunyang Luo,
Zihao Bo,
Shibo Zhang,
Abdusalam Abdukerim,
Chen Cheng,
Wei Chen,
Xun Chen,
Yunhua Chen,
Zhaokan Cheng,
Xiangyi Cui,
Yingjie Fan,
Deqing Fang,
Changbo Fu,
Mengting Fu,
Lisheng Geng,
Karl Giboni,
Linhui Gu,
Xuyuan Guo,
Chencheng Han,
Ke Han,
Changda He,
**rong He,
Di Huang,
Yanlin Huang,
Zhou Huang
, et al. (66 additional authors not shown)
Abstract:
PandaX-4T experiment is a deep-underground dark matter direct search experiment that employs a dual-phase time projection chamber with a sensitive volume containing 3.7 tonne of liquid xenon. The detector of PandaX-4T is capable of simultaneously collecting the primary scintillation and ionization signals, utilizing their ratio to discriminate dark matter signals from background sources such as ga…
▽ More
PandaX-4T experiment is a deep-underground dark matter direct search experiment that employs a dual-phase time projection chamber with a sensitive volume containing 3.7 tonne of liquid xenon. The detector of PandaX-4T is capable of simultaneously collecting the primary scintillation and ionization signals, utilizing their ratio to discriminate dark matter signals from background sources such as gamma rays and beta particles. The signal response model plays a crucial role in interpreting the data obtained by PandaX-4T. It describes the conversion from the deposited energy by dark matter interactions to the detectable signals within the detector. The signal response model is utilized in various PandaX-4T results. This work provides a comprehensive description of the procedures involved in constructing and parameter-fitting the signal response model for the energy range of approximately 1 keV to 25 keV for electronic recoils and 6 keV to 90 keV for nuclear recoils. It also covers the signal reconstruction, selection, and correction methods, which are crucial components integrated into the signal response model.
△ Less
Submitted 14 June, 2024; v1 submitted 7 March, 2024;
originally announced March 2024.
-
Waveform Simulation in PandaX-4T
Authors:
Jiafu Li,
Abdusalam Abdukerim,
Chen Cheng,
Zihao Bo,
Wei Chen,
Xun Chen,
Yunhua Chen,
Zhaokan Cheng,
Xiangyi Cui,
Yingjie Fan,
Deqing Fang,
Changbo Fu,
Mengting Fu,
Lisheng Geng,
Karl Giboni,
Linhui Gu,
Xuyuan Guo,
Chencheng Han,
Ke Han,
Changda He,
**rong He,
Di Huang,
Yanlin Huang,
Zhou Huang,
Ruquan Hou
, et al. (66 additional authors not shown)
Abstract:
Signal reconstruction through software processing is a crucial component of the background and signal models in the PandaX-4T experiment, which is a multi-tonne dark matter direct search experiment. The accuracy of signal reconstruction is influenced by various detector artifacts, including noise, dark count of photomultiplier, impurity photoionization in the detector, and other relevant considera…
▽ More
Signal reconstruction through software processing is a crucial component of the background and signal models in the PandaX-4T experiment, which is a multi-tonne dark matter direct search experiment. The accuracy of signal reconstruction is influenced by various detector artifacts, including noise, dark count of photomultiplier, impurity photoionization in the detector, and other relevant considerations. In this study, we present a detailed description of a semi-data-driven approach designed to simulate the signal waveform. This work provides a reliable model for the efficiency and bias of the signal reconstruction in the data analysis of PandaX-4T. By comparing critical variables which relate to the temporal shape and hit pattern of the signals, we demonstrate a good agreement between the simulation and data.
△ Less
Submitted 21 May, 2024; v1 submitted 18 December, 2023;
originally announced December 2023.
-
Search for Dark-Matter-Nucleon Interactions with a Dark Mediator in PandaX-4T
Authors:
Di Huang,
Abdusalam Abdukerim,
Zihao Bo,
Wei Chen,
Xun Chen,
Yunhua Chen,
Chen Cheng,
Zhaokan Cheng,
Xiangyi Cui,
Yingjie Fan,
Deqing Fang,
Changbo Fu,
Mengting Fu,
Lisheng Geng,
Karl Giboni,
Linhui Gu,
Xuyuan Guo,
Chencheng Han,
Ke Han,
Changda He,
**rong He,
Yanlin Huang,
Zhou Huang,
Ruquan Hou,
Xiangdong Ji
, et al. (70 additional authors not shown)
Abstract:
We report results of a search for dark-matter-nucleon interactions via a dark mediator using optimized low-energy data from the PandaX-4T liquid xenon experiment. With the ionization-signal-only data and utilizing the Migdal effect, we set the most stringent limits on the cross section for dark matter masses ranging from 30~$\rm{MeV/c^2}$ to 2~$\rm{GeV/c^2}$. Under the assumption that the dark med…
▽ More
We report results of a search for dark-matter-nucleon interactions via a dark mediator using optimized low-energy data from the PandaX-4T liquid xenon experiment. With the ionization-signal-only data and utilizing the Migdal effect, we set the most stringent limits on the cross section for dark matter masses ranging from 30~$\rm{MeV/c^2}$ to 2~$\rm{GeV/c^2}$. Under the assumption that the dark mediator is a dark photon that decays into scalar dark matter pairs in the early Universe, we rule out significant parameter space of such thermal relic dark-matter model.
△ Less
Submitted 18 December, 2023; v1 submitted 3 August, 2023;
originally announced August 2023.
-
Search for light dark matter from atmosphere in PandaX-4T
Authors:
Xuyang Ning,
Abdusalam Abdukerim,
Zihao Bo,
Wei Chen,
Xun Chen,
Yunhua Chen,
Chen Cheng,
Zhaokan Cheng,
Xiangyi Cui,
Yingjie Fan,
Deqing Fang,
Changbo Fu,
Mengting Fu,
Lisheng Geng,
Karl Giboni,
Linhui Gu,
Xuyuan Guo,
Chencheng Han,
Ke Han,
Changda He,
**rong He,
Di Huang,
Yanlin Huang,
Zhou Huang,
Ruquan Hou
, et al. (70 additional authors not shown)
Abstract:
We report a search for light dark matter produced through the cascading decay of $η$ mesons, which are created as a result of inelastic collisions between cosmic rays and Earth's atmosphere. We introduce a new and general framework, publicly accessible, designed to address boosted dark matter specifically, with which a full and dedicated simulation including both elastic and quasi-elastic processe…
▽ More
We report a search for light dark matter produced through the cascading decay of $η$ mesons, which are created as a result of inelastic collisions between cosmic rays and Earth's atmosphere. We introduce a new and general framework, publicly accessible, designed to address boosted dark matter specifically, with which a full and dedicated simulation including both elastic and quasi-elastic processes of Earth attenuation effect on the dark matter particles arriving at the detector is performed. In the PandaX-4T commissioning data of 0.63 tonne$\cdot$year exposure, no significant excess over background is observed. The first constraints on the interaction between light dark matter generated in the atmosphere and nucleus through a light scalar mediator are obtained. The lowest excluded cross-section is set at $5.9 \times 10^{-37}{\rm cm^2}$ for dark matter mass of $0.1$ MeV$/c^2$ and mediator mass of 300 MeV$/c^2$. The lowest upper limit of $η$ to dark matter decay branching ratio is $1.6 \times 10^{-7}$.
△ Less
Submitted 25 July, 2023; v1 submitted 8 January, 2023;
originally announced January 2023.
-
Constraints on the axial-vector and pseudo-scalar mediated WIMP-nucleus interactions from PandaX-4T experiment
Authors:
Zhou Huang,
Chencheng Han,
Abdusalam Abdukerim,
Zihao Bo,
Wei Chen,
Xun Chen,
Yunhua Chen,
Chen Cheng,
Zhaokan Cheng,
Xiangyi Cui,
Yingjie Fan,
Deqing Fang,
Changbo Fu,
Mengting Fu,
Lisheng Geng,
Karl Giboni,
Linhui Gu,
Xuyuan Guo,
Ke Han,
Changda He,
**rong He,
Di Huang,
Yanlin Huang,
Ruquan Hou,
Xiangdong Ji
, et al. (66 additional authors not shown)
Abstract:
We present the constraints on the axial-vector and pseudo-scalar mediated WIMP-nucleus interactions from the PandaX-4T experiment, using the data set corresponding to a total exposure of 0.63~tonne$\cdot$year. No significant signal excess is observed, and the most stringent upper limits to date on the spin-dependent WIMP-neutron scattering cross section are set at 90\% confidence level with the mi…
▽ More
We present the constraints on the axial-vector and pseudo-scalar mediated WIMP-nucleus interactions from the PandaX-4T experiment, using the data set corresponding to a total exposure of 0.63~tonne$\cdot$year. No significant signal excess is observed, and the most stringent upper limits to date on the spin-dependent WIMP-neutron scattering cross section are set at 90\% confidence level with the minimum WIMP-neutron scattering cross section of 5.8$\times 10^{-42}$\si{\cm^{2}} for WIMP mass of 40~\si{\GeV/}$c^2$. Exclusion limits on the axial-vector and pseudo-scalar simplified models are also derived.
△ Less
Submitted 6 August, 2022;
originally announced August 2022.
-
A First Search for Solar $^8$B Neutrino in the PandaX-4T Experiment using Neutrino-Nucleus Coherent Scattering
Authors:
Wenbo Ma,
Abdusalam Abdukerim,
Chen Cheng,
Zihao Bo,
Wei Chen,
Xun Chen,
Yunhua Chen,
Zhaokan Cheng,
Xiangyi Cui,
Yingjie Fan,
Deqing Fang,
Changbo Fu,
Mengting Fu,
Lisheng Geng,
Karl Giboni,
Linhui Gu,
Xuyuan Guo,
Chencheng Han,
Ke Han,
Changda He,
**rong He,
Di Huang,
Yanlin Huang,
Zhou Huang,
Ruquan Hou
, et al. (66 additional authors not shown)
Abstract:
A search for interactions from solar $^8$B neutrinos elastically scattering off xenon nuclei using PandaX-4T commissioning data is reported. The energy threshold of this search is further lowered compared with the previous search for dark matter, with various techniques utilized to suppress the background that emerges from data with the lowered threshold. A blind analysis is performed on the data…
▽ More
A search for interactions from solar $^8$B neutrinos elastically scattering off xenon nuclei using PandaX-4T commissioning data is reported. The energy threshold of this search is further lowered compared with the previous search for dark matter, with various techniques utilized to suppress the background that emerges from data with the lowered threshold. A blind analysis is performed on the data with an effective exposure of 0.48 tonne$\cdot$year, and no significant excess of events is observed. Among results obtained using the neutrino-nucleus coherent scattering, our results give the best constraint on the solar $^8$B neutrino flux. We further provide a more stringent limit on the cross section between dark matter and nucleon in the mass range from 3 to 9 GeV/c$^2$.
△ Less
Submitted 13 January, 2023; v1 submitted 11 July, 2022;
originally announced July 2022.
-
Neutron-induced nuclear recoil background in the PandaX-4T experiment
Authors:
Zhou Huang,
Guofang Shen,
Qiuhong Wang,
Abdusalam Abdukerim,
Zihao Bo,
Wei Chen,
Xun Chen,
Yunhua Chen,
Chen Cheng,
Yunshan Cheng,
Xiangyi Cui,
Yingjie Fan,
Deqing Fang,
Changbo Fu,
Mengting Fu,
Lisheng Geng,
Karl Giboni,
Linhui Gu,
Xuyuan Guo,
Chencheng Han,
Ke Han,
Changda He,
**rong He,
Di Huang,
Yanlin Huang
, et al. (55 additional authors not shown)
Abstract:
Neutron-induced nuclear recoil background is critical to the dark matter searches in the PandaX-4T liquid xenon experiment. This paper studies the feature of neutron background in liquid xenon and evaluates their contribution in the single scattering nuclear recoil events through three methods. The first method is fully Monte Carlo simulation based. The last two are data-driven methods that also u…
▽ More
Neutron-induced nuclear recoil background is critical to the dark matter searches in the PandaX-4T liquid xenon experiment. This paper studies the feature of neutron background in liquid xenon and evaluates their contribution in the single scattering nuclear recoil events through three methods. The first method is fully Monte Carlo simulation based. The last two are data-driven methods that also use the multiple scattering signals and high energy signals in the data, respectively. In the PandaX-4T commissioning data with an exposure of 0.63 tonne-year, all these methods give a consistent result that there are $1.15\pm0.57$ neutron-induced background in dark matter signal region within an approximated nuclear recoil energy window between 5 and 100 keV.
△ Less
Submitted 29 July, 2022; v1 submitted 13 June, 2022;
originally announced June 2022.
-
A Search for Light Fermionic Dark Matter Absorption on Electrons in PandaX-4T
Authors:
Dan Zhang,
Abdusalam Abdukerim,
Zihao Bo,
Wei Chen,
Xun Chen,
Yunhua Chen,
Chen Cheng,
Zhaokan Cheng,
Xiangyi Cui,
Yingjie Fan,
Deqing Fang,
Changbo Fu,
Mengting Fu,
Lisheng Geng,
Karl Giboni,
Linhui Gu,
Xuyuan Guo,
Ke Han,
Changda He,
**rong He,
Di Huang,
Yanlin Huang,
Zhou Huang,
Ruquan Hou,
Xiangdong Ji
, et al. (67 additional authors not shown)
Abstract:
We report a search on a sub-MeV fermionic dark matter absorbed by electrons with an outgoing active neutrino using the 0.63 tonne-year exposure collected by PandaX-4T liquid xenon experiment. No significant signals are observed over the expected background. The data are interpreted into limits to the effective couplings between such dark matter and electrons. For axial-vector or vector interaction…
▽ More
We report a search on a sub-MeV fermionic dark matter absorbed by electrons with an outgoing active neutrino using the 0.63 tonne-year exposure collected by PandaX-4T liquid xenon experiment. No significant signals are observed over the expected background. The data are interpreted into limits to the effective couplings between such dark matter and electrons. For axial-vector or vector interactions, our sensitivity is competitive in comparison to existing astrophysical bounds on the decay of such dark matter into photon final states. In particular, we present the first direct detection limits for an axial-vector (vector) interaction which are the strongest in the mass range from 25 to 45 (35 to 50) keV/c$^2$.
△ Less
Submitted 4 July, 2023; v1 submitted 5 June, 2022;
originally announced June 2022.
-
First search for the absorption of fermionic dark matter with the PandaX-4T experiment
Authors:
Linhui Gu,
Abdusalam Abdukerim,
Zihao Bo,
Wei Chen,
Xun Chen,
Yunhua Chen,
Chen Cheng,
Yunshan Cheng,
Zhaokan Cheng,
Xiangyi Cui,
Yingjie Fan,
Deqing Fang,
Changbo Fu,
Mengting Fu,
Lisheng Geng,
Karl Giboni,
Xuyuan Guo,
Ke Han,
Changda He,
**rong He,
Di Huang,
Yanlin Huang,
Zhou Huang,
Ruquan Hou,
Xiangdong Ji
, et al. (64 additional authors not shown)
Abstract:
Compared with the signature of dark matter elastic scattering off nuclei, the absorption of fermionic dark matter by nuclei opens up a new searching channel for light dark matter with a characteristic monoenergetic signal. In this Letter, we explore the $95.0$-day data from the PandaX-4T commissioning run and report the first dedicated searching results of the fermionic dark matter absorption sign…
▽ More
Compared with the signature of dark matter elastic scattering off nuclei, the absorption of fermionic dark matter by nuclei opens up a new searching channel for light dark matter with a characteristic monoenergetic signal. In this Letter, we explore the $95.0$-day data from the PandaX-4T commissioning run and report the first dedicated searching results of the fermionic dark matter absorption signal through a neutral current process. No significant signal was found, and the lowest limit on the dark matter-nucleon interaction cross section is set to be $1.5\times10^{-50}$ cm$^2$ for a fermionic dark matter mass of $40$ MeV/$c^2$ with 90\% confidence level.
△ Less
Submitted 14 October, 2022; v1 submitted 31 May, 2022;
originally announced May 2022.
-
Measurement of Double Beta Decay Half-life of $^{136}$Xe with the PandaX-4T Detector
Authors:
PandaX Collaboration,
Lin Si,
Zhaokan Cheng,
Abdusalam Abdukerim,
Zihao Bo,
Wei Chen,
Xun Chen,
Yunhua Chen,
Chen Cheng,
Yunshan Cheng,
Xiangyi Cui,
Yingjie Fan,
Deqing Fang,
Changbo Fu,
Mengting Fu,
Lisheng Geng,
Karl Giboni,
Linhui Gu,
Xuyuan Guo,
Ke Han,
Changda He,
**rong He,
Di Huang,
Yanlin Huang,
Zhou Huang
, et al. (63 additional authors not shown)
Abstract:
Precise measurement of two-neutrino double beta decay (DBD) half-life is an important step for the searches of Majorana neutrinos with neutrinoless double beta decay. We report the measurement of DBD half-life of $^{136}$Xe using the PandaX-4T dual-phase Time Projection Chamber (TPC) with 3.7-tonne natural xenon and the first 94.9-day physics data release. The background model in the fiducial volu…
▽ More
Precise measurement of two-neutrino double beta decay (DBD) half-life is an important step for the searches of Majorana neutrinos with neutrinoless double beta decay. We report the measurement of DBD half-life of $^{136}$Xe using the PandaX-4T dual-phase Time Projection Chamber (TPC) with 3.7-tonne natural xenon and the first 94.9-day physics data release. The background model in the fiducial volume is well constrained in situ by events in the outer active region. With a $^{136}$Xe exposure of 15.5 kg-year, we establish the half-life as $2.27 \pm 0.03 (stat.)\pm 0.10 (syst.)\times 10^{21}$ years. This is the first DBD half-life measurement with natural xenon and demonstrates the physics capability of a large-scale liquid xenon TPC in the field of rare event searches.
△ Less
Submitted 12 December, 2022; v1 submitted 25 May, 2022;
originally announced May 2022.
-
A search for two-component Majorana dark matter in a simplified model using the full exposure data of PandaX-II experiment
Authors:
Ying Yuan,
Abdusalam Abdukerim,
Zihao Bo,
Wei Chen,
Xun Chen,
Yunhua Chen,
Chen Cheng,
Xiangyi Cui,
Yingjie Fan,
Deqing Fang,
Changbo Fu,
Mengting Fu,
Lisheng Geng,
Karl Giboni,
Linhui Gu,
Xuyuan Guo,
Ke Han,
Changda He,
**rong He,
Di Huang,
Yanlin Huang,
Zhou Huang,
Ruquan Hou,
Xiangdong Ji,
Yonglin Ju
, et al. (53 additional authors not shown)
Abstract:
In the two-component Majorana dark matter model, one dark matter particle can scatter off the target nuclei, and turn into a slightly heavier component. In the framework of a simplified model with a vector boson mediator, both the tree-level and loop-level processes contribute to the signal in direct detection experiment. In this paper, we report the search results for such dark matter from PandaX…
▽ More
In the two-component Majorana dark matter model, one dark matter particle can scatter off the target nuclei, and turn into a slightly heavier component. In the framework of a simplified model with a vector boson mediator, both the tree-level and loop-level processes contribute to the signal in direct detection experiment. In this paper, we report the search results for such dark matter from PandaX-II experiment, using total data of the full 100.7 tonne$\cdot$day exposure. No significant excess is observed, so strong constraints on the combined parameter space of mediator mass and dark matter mass are derived. With the complementary search results from collider experiments, a large range of parameter space can be excluded.
△ Less
Submitted 16 May, 2022;
originally announced May 2022.
-
Study of background from accidental coincidence signals in the PandaX-II experiment
Authors:
PandaX-II Collaboration,
:,
Abdusalam Abdukerim,
Wei Chen,
Xun Chen,
Yunhua Chen,
Chen Cheng,
Xiangyi Cui,
Yingjie Fan,
Deqing Fang,
Changbo Fu,
Mengting Fu,
Lisheng Geng,
Karl Giboni,
Linhui Gu,
Xuyuan Guo,
Ke Han,
Changda He,
Di Huang,
Yan Huang,
Yanlin Huang,
Zhou Huang,
Xiangdong Ji,
Yonglin Ju,
Shuaijie Li
, et al. (42 additional authors not shown)
Abstract:
The PandaX-II experiment employed a 580kg liquid xenon detector to search for the interactions between dark matter particles and the target xenon atoms. The accidental coincidences of isolated signals result in a dangerous background which mimic the signature of the dark matter. We performed a detailed study on the accidental coincidence background in PandaX-II, including the possible origin of th…
▽ More
The PandaX-II experiment employed a 580kg liquid xenon detector to search for the interactions between dark matter particles and the target xenon atoms. The accidental coincidences of isolated signals result in a dangerous background which mimic the signature of the dark matter. We performed a detailed study on the accidental coincidence background in PandaX-II, including the possible origin of the isolated signals, the background level and corresponding background suppression method. With a boosted-decision-tree algorithm, the accidental coincidence background is reduced by 70% in the dark matter signal region, thus the sensitivity of dark matter search at PandaX-II is improved.
△ Less
Submitted 1 July, 2022; v1 submitted 23 April, 2022;
originally announced April 2022.
-
A Search for the Cosmic Ray Boosted Sub-GeV Dark Matter at the PandaX-II Experiment
Authors:
Xiangyi Cui,
Abdusalam Abdukerim,
Zihao Bo,
Wei Chen,
Xun Chen,
Yunhua Chen,
Chen Cheng,
Yunshan Cheng,
Yingjie Fan,
Deqing Fang,
Changbo Fu,
Mengting Fu,
Lisheng Geng,
Karl Giboni,
Linhui Gu,
Xuyuan Guo,
Ke Han,
Changda He,
**rong He,
Di Huang,
Yanlin Huang,
Zhou Huang,
Ruquan Hou,
Xiangdong Ji,
Yonglin Ju
, et al. (54 additional authors not shown)
Abstract:
We report a novel search for the cosmic ray boosted dark matter using the 100~tonne$\cdot$day full data set of the PandaX-II detector located at the China **** Underground Laboratory. With the extra energy gained from the cosmic rays, sub-GeV dark matter particles can produce visible recoil signals in the detector. The diurnal modulations in rate and energy spectrum are utilized to further enha…
▽ More
We report a novel search for the cosmic ray boosted dark matter using the 100~tonne$\cdot$day full data set of the PandaX-II detector located at the China **** Underground Laboratory. With the extra energy gained from the cosmic rays, sub-GeV dark matter particles can produce visible recoil signals in the detector. The diurnal modulations in rate and energy spectrum are utilized to further enhance the signal sensitivity. Our result excludes the dark matter-nucleon elastic scattering cross section between 10$^{-31}$cm$^{2}$ and 10$^{-28}$cm$^{2}$ for a dark matter masses from 0.1 MeV/$c^2$ to 0.1 GeV/$c^2$, with a large parameter space previously unexplored by experimental collaborations.
△ Less
Submitted 11 April, 2022; v1 submitted 16 December, 2021;
originally announced December 2021.
-
Low Radioactive Material Screening and Background Control for the PandaX-4T Experiment
Authors:
Zhicheng Qian,
Lin Si,
Abdusalam Abdukerim,
Zihao Bo,
Wei Chen,
Xun Chen,
Yunhua Chen,
Chen Cheng,
Yunshan Cheng,
Xiangyi Cui,
Yingjie Fan,
Deqing Fang,
Changbo Fu,
Mengting Fu,
Lisheng Geng,
Karl Giboni,
Linhui Gu,
Xuyuan Guo,
Ke Han,
Changda He,
**rong He,
Di Huang,
Yanlin Huang,
Zhou Huang,
Ruquan Hou
, et al. (54 additional authors not shown)
Abstract:
PandaX-4T is a ton-scale dark matter direct detection experiment using a dual-phase TPC technique at the China **** Underground Laboratory. Various ultra-low background technologies have been developed and applied to material screening for PandaX-4T, including HPGe gamma spectroscopy, ICP-MS, NAA, radon emanation measurement system, krypton assay station, and alpha detection system. Low backgro…
▽ More
PandaX-4T is a ton-scale dark matter direct detection experiment using a dual-phase TPC technique at the China **** Underground Laboratory. Various ultra-low background technologies have been developed and applied to material screening for PandaX-4T, including HPGe gamma spectroscopy, ICP-MS, NAA, radon emanation measurement system, krypton assay station, and alpha detection system. Low background materials were selected to assemble the detector. Surface treatment procedures were investigated to further suppress radioactive background. Combining measured results and Monte Carlo simulation, the total material background rates of PandaX-4T in the energy region of 1-25 keV$\rm{}_{ee}$ are estimated to be (9.9 $\pm$ 1.9) $\times \ 10^{-3}$ mDRU for electron recoil and (2.8 $\pm$ 0.6) $\times \ 10^{-4}$ mDRU for nuclear recoil. In addition, $^{nat}$Kr in the detector is estimated to be <8 ppt.
△ Less
Submitted 23 April, 2022; v1 submitted 6 December, 2021;
originally announced December 2021.
-
Light yield and field dependence measurement in PandaX-II dual-phase xenon detector
Authors:
Zhou Huang,
Abdusalam Abdukerim,
Zihao Bo,
Wei Chen,
Xun Chen,
Yunhua Chen,
Chen Cheng,
Yunshan Cheng,
Xiangyi Cui,
Yingjie Fan,
Deqing Fang,
Changbo Fu,
Mengting Fu,
Lisheng Geng,
Karl Giboni,
Linhui Gu,
Xuyuan Guo,
Ke Han,
Changda He,
**rong He,
Di Huang,
Yanlin Huang,
Ruquan Hou,
Xiangdong Ji,
Yonglin Ju
, et al. (54 additional authors not shown)
Abstract:
The dual-phase xenon time projection chamber (TPC) is one of the most sensitive detector technology for dark matter direct search, where the energy deposition of incoming particle can be converted into photons and electrons through xenon excitation and ionization. The detector response to signal energy deposition varies significantly with the electric field in liquid xenon. We study the detector's…
▽ More
The dual-phase xenon time projection chamber (TPC) is one of the most sensitive detector technology for dark matter direct search, where the energy deposition of incoming particle can be converted into photons and electrons through xenon excitation and ionization. The detector response to signal energy deposition varies significantly with the electric field in liquid xenon. We study the detector's light yield and its dependence on the electric field in the PandaX-II dual-phase detector containing 580~kg liquid xenon in the sensitive volume. From our measurements, the light yield at electric fields from 0~V/cm to 317~V/cm is obtained for energy depositions up to 236~keV.
△ Less
Submitted 3 December, 2021; v1 submitted 2 November, 2021;
originally announced November 2021.
-
Dark Matter Search Results from the PandaX-4T Commissioning Run
Authors:
Yue Meng,
Zhou Wang,
Yi Tao,
Abdusalam Abdukerim,
Zihao Bo,
Wei Chen,
Xun Chen,
Yunhua Chen,
Chen Cheng,
Yunshan Cheng,
Xiangyi Cui,
Yingjie Fan,
Deqing Fang,
Changbo Fu,
Mengting Fu,
Lisheng Geng,
Karl Giboni,
Linhui Gu,
Xuyuan Guo,
Ke Han,
Changda He,
**rong He,
Di Huang,
Yanlin Huang,
Zhou Huang
, et al. (54 additional authors not shown)
Abstract:
We report the first dark matter search results using the commissioning data from PandaX-4T. Using a time projection chamber with 3.7-tonne of liquid xenon target and an exposure of 0.63 tonne$\cdot$year, 1058 candidate events are identified within an approximate nuclear recoil energy window between 5 and 100 keV. No significant excess over background is observed. Our data set a stringent limit to…
▽ More
We report the first dark matter search results using the commissioning data from PandaX-4T. Using a time projection chamber with 3.7-tonne of liquid xenon target and an exposure of 0.63 tonne$\cdot$year, 1058 candidate events are identified within an approximate nuclear recoil energy window between 5 and 100 keV. No significant excess over background is observed. Our data set a stringent limit to the dark matter-nucleon spin-independent interactions, with a lowest excluded cross section (90% C.L.) of $3.8\times10^{-47} $cm$^2$ at a dark matter mass of 30 GeV/$c^2$.
△ Less
Submitted 17 December, 2021; v1 submitted 28 July, 2021;
originally announced July 2021.
-
Horizontal Position Reconstruction in PandaX-II
Authors:
Dan Zhang,
Andi Tan,
Abdusalam Abdukerim,
Wei Chen,
Xun Chen,
Yunhua Chen,
Chen Cheng,
Xiangyi Cui,
Yingjie Fan,
Deqing Fang,
Changbo Fu,
Mengting Fu,
Lisheng Geng,
Karl Giboni,
Linhui Gu,
Xuyuan Guo,
Ke Han,
Changda He,
Shengming He,
Di Huang,
Yan Huang,
Yanlin Huang,
Zhou Huang,
Xiangdong Ji,
Yonglin Ju
, et al. (47 additional authors not shown)
Abstract:
Dual-phase noble-gas time projection chambers (TPCs) have improved the sensitivities for dark matter direct search in past decades. The capability of TPCs to reconstruct 3-D vertexes of keV scale recoilings is one of the most advantageous features. In this work, we develop two horizontal position reconstruction algorithms for the PandaX-II dark matter search experiment using the dual-phase liquid…
▽ More
Dual-phase noble-gas time projection chambers (TPCs) have improved the sensitivities for dark matter direct search in past decades. The capability of TPCs to reconstruct 3-D vertexes of keV scale recoilings is one of the most advantageous features. In this work, we develop two horizontal position reconstruction algorithms for the PandaX-II dark matter search experiment using the dual-phase liquid xenon TPC. Both algorithms are optimized by the $^{83m}$Kr calibration events and use photon distribution of ionization signals among photomultiplier tubes to infer the positions. According to the events coming from the gate electrode, the uncertainties in the horizontal positions are 3.4 mm (3.9 mm) in the analytical (simulation-based) algorithm for an ionization signal with several thousand photon electrons in the center of the TPC
△ Less
Submitted 7 October, 2021; v1 submitted 15 June, 2021;
originally announced June 2021.
-
Constraining self-interacting dark matter with the full dataset of PandaX-II
Authors:
Jijun Yang,
Abdusalam Abdukerim,
Wei Chen,
Xun Chen,
Yunhua Chen,
Chen Cheng,
Xiangyi Cui,
Yingjie Fan,
Deqing Fang,
Changbo Fu,
Mengting Fu,
Lisheng Geng,
Karl Giboni,
Linhui Gu,
Xuyuan Guo,
Ke Han,
Changda He,
Shengming He,
Di Huang,
Yan Huang,
Ran Huo,
Yanlin Huang,
Zhou Huang,
Xiangdong Ji,
Yonglin Ju
, et al. (47 additional authors not shown)
Abstract:
Self-interacting Dark Matter (SIDM) is a leading candidate proposed to solve discrepancies between predictions of the prevailing cold dark matter theory and observations of galaxies. Many SIDM models predict the existence of a light force carrier that mediate strong dark matter self-interactions. If the mediator couples to the standard model particles, it could produce characteristic signals in da…
▽ More
Self-interacting Dark Matter (SIDM) is a leading candidate proposed to solve discrepancies between predictions of the prevailing cold dark matter theory and observations of galaxies. Many SIDM models predict the existence of a light force carrier that mediate strong dark matter self-interactions. If the mediator couples to the standard model particles, it could produce characteristic signals in dark matter direct detection experiments. We report searches for SIDM models with a light mediator using the full dataset of the PandaX-II experiment, based on a total exposure of 132 tonne-days. No significant excess over background is found, and our likelihood analysis leads to a strong upper limit on the dark matter-nucleon coupling strength. We further combine the PandaX-II constraints and those from observations of the light element abundances in the early universe, and show that direct detection and cosmological probes can provide complementary constraints on dark matter models with a light mediator.
△ Less
Submitted 24 October, 2021; v1 submitted 29 April, 2021;
originally announced April 2021.
-
Determination of responses of liquid xenon to low energy electron and nuclear recoils using the PandaX-II detector
Authors:
Binbin Yan,
Abdusalam Abdukerim,
Wei Chen,
Xun Chen,
Yunhua Chen,
Chen Cheng,
Xiangyi Cui,
Yingjie Fan,
Deqing Fang,
Changbo Fu,
Mengting Fu,
Lisheng Geng,
Karl Giboni,
Linhui Gu,
Xuyuan Guo,
Ke Han,
Changda He,
Di Huang,
Peiyao Huang,
Yan Huang,
Yanlin Huang,
Zhou Huang,
Xiangdong Ji,
Yonglin Ju,
Shuaijie Li
, et al. (41 additional authors not shown)
Abstract:
We report a systematic determination of the responses of PandaX-II, a dual phase xenon time projection chamber detector, to low energy recoils. The electron recoil (ER) and nuclear recoil (NR) responses are calibrated, respectively, with injected tritiated methane or $^{220}$Rn source, and with $^{241}$Am-Be neutron source, within an energy range from $1-25$ keV (ER) and $4-80$ keV (NR), under the…
▽ More
We report a systematic determination of the responses of PandaX-II, a dual phase xenon time projection chamber detector, to low energy recoils. The electron recoil (ER) and nuclear recoil (NR) responses are calibrated, respectively, with injected tritiated methane or $^{220}$Rn source, and with $^{241}$Am-Be neutron source, within an energy range from $1-25$ keV (ER) and $4-80$ keV (NR), under the two drift fields of 400 and 317 V/cm. An empirical model is used to fit the light yield and charge yield for both types of recoils. The best fit models can well describe the calibration data. The systematic uncertainties of the fitted models are obtained via statistical comparison against the data.
△ Less
Submitted 18 February, 2021;
originally announced February 2021.
-
Search for Light Dark Matter-Electron Scatterings in the PandaX-II Experiment
Authors:
Chen Cheng,
Pengwei Xie,
Abdusalam Abdukerim,
Wei Chen,
Xun Chen,
Yunhua Chen,
Xiangyi Cui,
Yingjie Fan,
Deqing Fang,
Changbo Fu,
Mengting Fu,
Lisheng Geng,
Karl Giboni,
Linhui Gu,
Xuyuan Guo,
Ke Han,
Changda He,
Di Huang,
Yan Huang,
Yanlin Huang,
Zhou Huang,
Xiangdong Ji,
Yonglin Ju,
Shuaijie Li,
Qing Lin
, et al. (45 additional authors not shown)
Abstract:
We report constraints on light dark matter through its interactions with shell electrons in the PandaX-II liquid xenon detector with a total 46.9 tonne$\cdot$day exposure. To effectively search for these very low energy electron recoils, ionization-only signals are selected from the data. 1821 candidates are identified within ionization signal range between 50 to 75 photoelectrons, corresponding t…
▽ More
We report constraints on light dark matter through its interactions with shell electrons in the PandaX-II liquid xenon detector with a total 46.9 tonne$\cdot$day exposure. To effectively search for these very low energy electron recoils, ionization-only signals are selected from the data. 1821 candidates are identified within ionization signal range between 50 to 75 photoelectrons, corresponding to a mean electronic recoil energy from 0.08 to 0.15 keV. The 90% C.L. exclusion limit on the scattering cross section between the dark matter and electron is calculated based on Poisson statistics. Under the assumption of point interaction, we provide the world's most stringent limit within the dark matter mass range from 15 to 30 $\rm MeV/c^2$, with the corresponding cross section from $2.5\times10^{-37}$ to $3.1\times10^{-38}$ cm$^2$.
△ Less
Submitted 7 May, 2021; v1 submitted 19 January, 2021;
originally announced January 2021.
-
A search for solar axions and anomalous neutrino magnetic moment with the complete PandaX-II data
Authors:
Xiaopeng Zhou,
Xinning Zeng,
Xuyang Ning,
Abdusalam Abdukerim,
Wei Chen,
Xun Chen,
Yunhua Chen,
Chen Cheng,
Xiangyi Cui,
Yingjie Fan,
Deqing Fang,
Changbo Fu,
Mengting Fu,
Lisheng Geng,
Karl Giboni,
Linhui Gu,
Xuyuan Guo,
Ke Han,
Changda He,
Di Huang,
Yan Huang,
Yanlin Huang,
Zhou Huang,
Xiangdong Ji,
Yonglin Ju
, et al. (41 additional authors not shown)
Abstract:
We report a search for new physics signals using the low energy electron recoil events in the complete data set from PandaX-II, in light of the recent event excess reported by XENON1T. The data correspond to a total exposure of 100.7 ton-day with liquid xenon. With robust estimates of the dominant background spectra, we perform sensitive searches on solar axions and neutrinos with enhanced magneti…
▽ More
We report a search for new physics signals using the low energy electron recoil events in the complete data set from PandaX-II, in light of the recent event excess reported by XENON1T. The data correspond to a total exposure of 100.7 ton-day with liquid xenon. With robust estimates of the dominant background spectra, we perform sensitive searches on solar axions and neutrinos with enhanced magnetic moment. We find that the axion-electron coupling $g_{Ae}<4.6\times 10^{-12}$ for an axion mass less than $\rm 0.1~keV/c^2$ and the neutrino magnetic moment $μ_ν<4.9\times 10^{-11}μ_{B}$ at 90% confidence level. The observed excess from XENON1T is within our experimental constraints.
△ Less
Submitted 23 November, 2021; v1 submitted 14 August, 2020;
originally announced August 2020.
-
Results of Dark Matter Search using the Full PandaX-II Exposure
Authors:
Qiuhong Wang,
Abdusalam Abdukerim,
Wei Chen,
Xun Chen,
Yunhua Chen,
Chen Cheng,
Xiangyi Cui,
Yingjie Fan,
Deqing Fang,
Changbo Fu,
Mengting Fu,
Lisheng Geng,
Karl Giboni,
Linhui Gu,
Xuyuan Guo,
Ke Han,
Changda He,
Di Huang,
Yan Huang,
Yanlin Huang,
Zhou Huang,
Xiangdong Ji,
Yonglin Ju,
Shuaijie Li,
Huaxuan Liu
, et al. (40 additional authors not shown)
Abstract:
We report the dark matter search results obtained using the full 132 ton$\cdot$day exposure of the PandaX-II experiment, including all data from March 2016 to August 2018. No significant excess of events is identified above the expected background. Upper limits are set on the spin-independent dark matter-nucleon interactions. The lowest 90% confidence level exclusion on the spin-independent cross…
▽ More
We report the dark matter search results obtained using the full 132 ton$\cdot$day exposure of the PandaX-II experiment, including all data from March 2016 to August 2018. No significant excess of events is identified above the expected background. Upper limits are set on the spin-independent dark matter-nucleon interactions. The lowest 90% confidence level exclusion on the spin-independent cross section is $2.2\times 10^{-46}$ cm$^2$ at a WIMP mass of 30 GeV/$c^2$.
△ Less
Submitted 1 January, 2021; v1 submitted 30 July, 2020;
originally announced July 2020.
-
Internal Calibration of the PandaX-II Detector with Radon Gaseous Sources
Authors:
Wenbo Ma,
Abdusalam Abdukerim,
Zihao Bo,
Wei Chen,
Xun Chen,
Yunhua Chen,
Chen Cheng,
Xiangyi Cui,
Yingjie Fan,
Deqing Fang,
Changbo Fu,
Mengting Fu,
Lisheng Geng,
Karl Giboni,
Linhui Gu,
Xuyuan Guo,
Ke Han,
Changda He,
Shengming He,
Di Huang,
Yan Huang,
Yanlin Huang,
Zhou Huang,
Xiangdong Ji,
Yonglin Ju
, et al. (43 additional authors not shown)
Abstract:
We have developed a low-energy electron recoil (ER) calibration method with $^{220}$Rn for the PandaX-II detector. $^{220}$Rn, emanated from natural thorium compounds, was fed into the detector through the xenon purification system. From 2017 to 2019, we performed three dedicated calibration campaigns with different radon sources. We studied the detector response to $α$, $β$, and $γ$ particles wit…
▽ More
We have developed a low-energy electron recoil (ER) calibration method with $^{220}$Rn for the PandaX-II detector. $^{220}$Rn, emanated from natural thorium compounds, was fed into the detector through the xenon purification system. From 2017 to 2019, we performed three dedicated calibration campaigns with different radon sources. We studied the detector response to $α$, $β$, and $γ$ particles with focus on low energy ER events. During the runs in 2017 and 2018, the amount of radioactivity of $^{222}$Rn were on the order of 1\% of that of $^{220}$Rn and thorium particulate contamination was negligible, especially in 2018. We also measured the background contribution from $^{214}$Pb for the first time in PandaX-II with the help from a $^{222}$Rn injection. Calibration strategy with $^{220}$Rn and $^{222}$Rn will be implemented in the upcoming PandaX-4T experiment and can be useful for other xenon-based detectors as well.
△ Less
Submitted 4 January, 2021; v1 submitted 16 June, 2020;
originally announced June 2020.
-
Ground-based calibration and characterization of the HE detectors for Insight-HXMT
Authors:
XuFang Li,
CongZhan Liu,
Zhi Chang,
YiFei Zhang,
XiaoBo Li,
He Gao,
ZhengWei Li,
XueFeng Lu,
Xu Zhou,
Aimei Zhang,
Tong Zhang,
FangJun Lu,
YuPeng Xu,
ShuangNan Zhang,
TiPei Li,
Mei Wu,
Shu Zhang,
HongWei Liu,
Fan Zhang,
LiMing Song,
YongJie **,
HuiMing Yu,
Zhao Zhang,
MinXue Fu,
YiBao Chen
, et al. (7 additional authors not shown)
Abstract:
High energy X-ray telescope (HE) is one of the three instruments of Insight-HXMT(Hard X-ray Modulation Telescope) payload. The HE detector (HED) array is composed of 18 actively NaI(Tl)/CsI(Na) phoswich scintillators with a total geometric area of ~ 5100cm^2 and cover the energy range 20-250 keV. In this paper we describe the on-ground detector-level calibration campaigns and present the principal…
▽ More
High energy X-ray telescope (HE) is one of the three instruments of Insight-HXMT(Hard X-ray Modulation Telescope) payload. The HE detector (HED) array is composed of 18 actively NaI(Tl)/CsI(Na) phoswich scintillators with a total geometric area of ~ 5100cm^2 and cover the energy range 20-250 keV. In this paper we describe the on-ground detector-level calibration campaigns and present the principal instrument properties of HEDs.
△ Less
Submitted 10 October, 2019;
originally announced October 2019.
-
Characterization of the first prototype CMOS pixel sensor developed for the CEPC vertex detector
Authors:
L. J. Chen,
H. B. Zhu,
X. C. Ai,
M. Fu,
R. Kiuchi,
Y. Liu,
Z. A. Liu,
X. C. Lou,
Y. P. Lu,
Q. Ouyang,
X. Shi,
J. Tao,
K. Wang,
N. Wang,
C. F. Yang,
Y. Zhang,
Y. Zhou
Abstract:
Purpose: CMOS pixel sensors have become extremely attractive for future high performance tracking devices. Initial R\&D work has been conducted for the vertex detector for the proposed Circular Electron Positron Collider that will allow precision Higgs measurements. It is critical to achieve low power consumption to minimize the material budget. This requires careful optimization of the sensor dio…
▽ More
Purpose: CMOS pixel sensors have become extremely attractive for future high performance tracking devices. Initial R\&D work has been conducted for the vertex detector for the proposed Circular Electron Positron Collider that will allow precision Higgs measurements. It is critical to achieve low power consumption to minimize the material budget. This requires careful optimization of the sensor diode geometry to reach high charge-over-capacitance that allows reduction in analog power consumption.
Methods: The electrode area and footprint are two critical elements in sensor diode geometry and have deciding impacts on the sensor charge collection performance. Prototype CMOS pixel sensor JadePix-1 has been developed with pixel sectors implementing different electrode area and footprint and their charge collection performance has been characterized with radioactive resources.
Results: Charge-to-voltage conversion gains are calibrated with low energy X-ray. Noise, charge collection efficiency, charge-over-capacitance and signal-to-noise ratio are obtained for pixel sectors of different electrode area and footprint.
Conclusion: Small electrode area and large footprint are preferred to achieve high charge-over-capacitance that promises low analog power consumption. Ongoing studies on sensor performance before and after irradiation, combined with this work, will conclude on the diode geometry optimization.
△ Less
Submitted 29 January, 2019;
originally announced January 2019.
-
Thermal and Tensile Strength Testing of Thermally-Conductive Adhesives and Carbon Foam
Authors:
Maxwell Chertok,
Minmin Fu,
Michael Irving,
Christian Neher,
Mengyao Shi,
Kirk Tolfa,
Mani Tripathi,
Yasmeen Vinson,
Ruby Wang,
Gayle Zheng
Abstract:
Future collider detectors, including silicon tracking detectors planned for the High Luminosity LHC, will require components and mechanical structures providing unprecedented strength-to-mass ratios, thermal conductivity, and radiation tolerance. This paper studies carbon foam used in conjunction with thermally conductive epoxy and thermally conductive tape for such applications. Thermal performan…
▽ More
Future collider detectors, including silicon tracking detectors planned for the High Luminosity LHC, will require components and mechanical structures providing unprecedented strength-to-mass ratios, thermal conductivity, and radiation tolerance. This paper studies carbon foam used in conjunction with thermally conductive epoxy and thermally conductive tape for such applications. Thermal performance and tensile strength measurements of aluminum-carbon foam-adhesive stacks are reported, along with initial radiation damage test results.
△ Less
Submitted 16 January, 2017; v1 submitted 29 August, 2016;
originally announced August 2016.
-
Reactive Bonding Film for Bonding Carbon Foam Through Metal Extrusion
Authors:
Maxwell Chertok,
Minmin Fu,
Michael Irving,
Christian Neher,
Mani Tripathi,
Ruby Wang,
Gayle Zheng
Abstract:
Future tracking detectors, such as those under development for the High Luminosity LHC, will require mechanical structures employing novel materials to reduce mass while providing excellent strength, thermal conductivity, and radiation tolerance. Adhesion methods for such materials are under study at present. This paper demonstrates the use of reactive bonding film as an adhesion method for bondin…
▽ More
Future tracking detectors, such as those under development for the High Luminosity LHC, will require mechanical structures employing novel materials to reduce mass while providing excellent strength, thermal conductivity, and radiation tolerance. Adhesion methods for such materials are under study at present. This paper demonstrates the use of reactive bonding film as an adhesion method for bonding carbon foam.
△ Less
Submitted 24 March, 2017; v1 submitted 24 June, 2016;
originally announced June 2016.