Detector performance of the Gamma-ray Transient Monitor onboard DRO-A Satellite
Authors:
Pei-Yi Feng,
Zheng-Hua An,
Da-Li Zhang,
Chen-Wei Wang,
Chao Zheng,
Sheng Yang,
Shao-Lin Xiong,
Jia-Cong Liu,
Xin-Qiao Li,
Ke Gong,
Xiao-**g Liu,
Min Gao,
Xiang-Yang Wen,
Ya-Qing liu,
Xiao-Yun Zhao,
Fan Zhang,
Xi-Lei Sun,
Hong Lu
Abstract:
Gamma-ray Transient Monitor (GTM) is an all-sky monitor onboard the Distant Retrograde Orbit-A (DRO-A) satellite with the scientific objective of detecting gamma-ray transients ranging from 20 keV to 1 MeV. GTM is equipped with 5 Gamma-ray Transient Probe (GTP) detector modules, utilizing the NaI(Tl) scintillator coupled with a SiPM array. To reduce the SiPM noise, GTP makes use of a dedicated dua…
▽ More
Gamma-ray Transient Monitor (GTM) is an all-sky monitor onboard the Distant Retrograde Orbit-A (DRO-A) satellite with the scientific objective of detecting gamma-ray transients ranging from 20 keV to 1 MeV. GTM is equipped with 5 Gamma-ray Transient Probe (GTP) detector modules, utilizing the NaI(Tl) scintillator coupled with a SiPM array. To reduce the SiPM noise, GTP makes use of a dedicated dual-channel coincident readout design. In this work, we firstly studied the impact of different coincidence times on detection efficiency and ultimately selected the 500 ns time coincidence window for offline data processing. To test the performance of GTPs and validate the Monte Carlo simulated energy response, we conducted comprehensive ground calibration tests using Hard X-ray Calibration Facility (HXCF) and radioactive sources, including energy response, detection efficiency, spatial response, bias-voltage response, and temperature dependence. We extensively presented the ground calibration results, and validated the design and mass model of GTP detector. These work paved the road for the in-flight observation and science data analysis.
△ Less
Submitted 15 January, 2024;
originally announced January 2024.
-
The Intrinsic Energy Resolution of LaBr$_3$(Ce) Crystal for GECAM
Authors:
Pei-Yi Feng,
Xi-Lei Sun,
Cheng-Er Wang,
Yong Deng,
Zheng-Hua An,
Da-Li Zhang,
Chao Zheng,
Xin-Qiao Li,
Shao-Lin Xiong,
Hong Lu
Abstract:
The intrinsic resolution is the primary limitation on the total energy resolution of LaBr$_3$(Ce) crystal. This intrinsic resolution arises from two effects: fluctuations occurring in the process of energy transfer to luminescent centers within the LaBr$_3$(Ce) crystal and the LaBr$_3$(Ce) crystal's non-proportional luminescence. Presently, experimental measurements regarding the intrinsic resolut…
▽ More
The intrinsic resolution is the primary limitation on the total energy resolution of LaBr$_3$(Ce) crystal. This intrinsic resolution arises from two effects: fluctuations occurring in the process of energy transfer to luminescent centers within the LaBr$_3$(Ce) crystal and the LaBr$_3$(Ce) crystal's non-proportional luminescence. Presently, experimental measurements regarding the intrinsic resolution of LaBr$_3$(Ce) crystal are scarce, and the underlying physical mechanisms remain incompletely understood. In this paper, we aim to elucidate the concept of intrinsic resolution. We investigated the entire physical process of luminescence following energy deposition in the LaBr$_3$(Ce) crystal, quantifying the various components in the total energy resolution. We conducted a series of experimental measurements and Geant4 simulations, determining the intrinsic resolution of LaBr$_3$(Ce) crystal to 100 keV electrons as 2.12%. The non-proportionality contributes significantly at 1.43%, while fluctuations in the energy transfer process accounted for 0.27%. It is evident that non-proportionality in light output constitutes the primary source of intrinsic resolution. Horizontal and vertical unevenness in light collection contributed 0.25% and 0.07%, respectively. Statistical fluctuations showed the largest impact on the total energy resolution, at 2.86%. The contribution from fluctuations in single-photoelectron events was 0.77%. Furthermore, we reconstructed the photon response using Geant4, and the consistency between the simulated relative light yield and the experimentally measured one confirmed the reliability of the LaBr$_3$(Ce) detector mass model employed in the simulation.
△ Less
Submitted 30 December, 2023;
originally announced January 2024.
-
The Energy Response of LaBr3(Ce), LaBr3(Ce,Sr) and NaI(Tl) Crystals for GECAM
Authors:
Pei-Yi Feng,
Xi-Lei Sun,
Zheng-Hua An,
Yong Deng,
Cheng-Er Wang,
Huang Jiang,
Jun-Jie Li,
Da-Li Zhang,
Xin-Qiao Li,
Shao-Lin Xiong,
Chao Zheng,
Ke Gong,
Sheng Yang,
Xiao-**g Liu,
Min Gao,
Xiang-Yang Wen,
Ya-Qing Liu,
Yan-Bing Xu,
Xiao-Yun Zhao,
Jia-Cong Liu,
Fan Zhang,
Hong Lu
Abstract:
The GECAM series of satellites utilize LaBr3(Ce), LaBr3(Ce,Sr), and NaI(Tl) crystals as sensitive materials for gamma-ray detectors (GRDs). To investigate the non-linearity in the detection of low-energy gamma rays and address errors in the E-C relationship calibration, comprehensive tests and comparative studies of the non-linearity of these three crystals were conducted using Compton electrons,…
▽ More
The GECAM series of satellites utilize LaBr3(Ce), LaBr3(Ce,Sr), and NaI(Tl) crystals as sensitive materials for gamma-ray detectors (GRDs). To investigate the non-linearity in the detection of low-energy gamma rays and address errors in the E-C relationship calibration, comprehensive tests and comparative studies of the non-linearity of these three crystals were conducted using Compton electrons, radioactive sources, and mono-energetic X-rays. The non-linearity test results for Compton electrons and X-rays displayed substantial differences, with all three crystals showing higher non-linearity for X-rays and gamma-rays than for Compton electrons. Despite LaBr3(Ce) and LaBr3(Ce,Sr) crystals having higher absolute light yields, they exhibited a noticeable non-linear decrease in light yield, especially at energies below 400 keV. The NaI(Tl) crystal demonstrated excess light output in the 6~200 keV range, reaching a maximum excess of 9.2% at 30 keV in X-ray testing and up to 15.5% at 14 keV during Compton electron testing, indicating a significant advantage in the detection of low-energy gamma rays. Furthermore, this paper explores the underlying causes of the observed non-linearity in these crystals. This study not only elucidates the detector responses of GECAM, but also marks the inaugural comprehensive investigation into the non-linearity of domestically produced lanthanum bromide and sodium iodide crystals.
△ Less
Submitted 27 December, 2023;
originally announced December 2023.
-
Advanced Scintillator Detector Concept (ASDC): A Concept Paper on the Physics Potential of Water-Based Liquid Scintillator
Authors:
J. R. Alonso,
N. Barros,
M. Bergevin,
A. Bernstein,
L. Bignell,
E. Blucher,
F. Calaprice,
J. M. Conrad,
F. B. Descamps,
M. V. Diwan,
D. A. Dwyer,
S. T. Dye,
A. Elagin,
P. Feng,
C. Grant,
S. Grullon,
S. Hans,
D. E. Jaffe,
S. H. Kettell,
J. R. Klein,
K. Lande,
J. G. Learned,
K. B. Luk,
J. Maricic,
P. Marleau
, et al. (25 additional authors not shown)
Abstract:
The recent development of Water-based Liquid Scintillator (WbLS), and the concurrent development of high-efficiency and high-precision-timing light sensors, has opened up the possibility for a new kind of large-scale detector capable of a very broad program of physics. The program would include determination of the neutrino mass hierarchy and observation of CP violation with long-baseline neutrino…
▽ More
The recent development of Water-based Liquid Scintillator (WbLS), and the concurrent development of high-efficiency and high-precision-timing light sensors, has opened up the possibility for a new kind of large-scale detector capable of a very broad program of physics. The program would include determination of the neutrino mass hierarchy and observation of CP violation with long-baseline neutrinos, searches for proton decay, ultra-precise solar neutrino measurements, geo- and supernova neutrinos including diffuse supernova antineutrinos, and neutrinoless double beta decay. We outline here the basic requirements of the Advanced Scintillation Detector Concept (ASDC), which combines the use of WbLS, do** with a number of potential isotopes for a range of physics goals, high efficiency and ultra-fast timing photosensors, and a deep underground location. We are considering such a detector at the Long Baseline Neutrino Facility (LBNF) far site, where the ASDC could operate in conjunction with the liquid argon tracking detector proposed by the LBNE collaboration. The goal is the deployment of a 30-100 kiloton-scale detector, the basic elements of which are being developed now in experiments such as WATCHMAN, ANNIE, SNO+, and EGADS.
△ Less
Submitted 24 October, 2014; v1 submitted 20 September, 2014;
originally announced September 2014.