-
Experiment Neutrino-4 search for sterile neutrino and results of measurements
Authors:
A. P. Serebrov,
R. M. Samoilov,
V. G. Ivochkin,
A. K. Fomin,
V. G. Zinoviev,
P. V. Neustroev,
V. L. Golovtsov,
S. S. Volkov,
A. V. Chernyj,
O. M. Zherebtsov,
M. E. Chaikovskii,
A. L. Petelin,
A. L. Izhutov,
A. A. Tuzov,
S. A. Sazontov,
M. O. Gromov,
V. V. Afanasiev,
M. E. Zaytsev,
A. A. Gerasimov,
V. V. Fedorov
Abstract:
The experiment Neutrino-4 had started in 2014 with a detector model and then was continued with a full-scale detector in 2016 - 2021. In this article we describe all steps of preparatory work on this experiment. We present all results of the Neutrino-4 experiment with increased statistical accuracy provided to date. The experimental setup is constructed to measure the flux and spectrum of the reac…
▽ More
The experiment Neutrino-4 had started in 2014 with a detector model and then was continued with a full-scale detector in 2016 - 2021. In this article we describe all steps of preparatory work on this experiment. We present all results of the Neutrino-4 experiment with increased statistical accuracy provided to date. The experimental setup is constructed to measure the flux and spectrum of the reactor antineutrinos as a function of distance to the center of the active zone of the SM-3 reactor (Dimitrovgrad, Russia) in the range of 6 - 12 meters. Using all the collected data, we performed a model-independent analysis to determine the oscillation parameters $Δm_{14}^2$ and $\sin^22θ_{14}$. The method of coherent summation of measurement results allows to directly demonstrate the oscillation effect. We present the analysis of possible systematic errors and the MC model of the experiment, which considers the possibility of the effect manifestation at the present precision level. As a result of the analysis, we can conclude that at currently available statistical accuracy we observe the oscillations at the $2.9σ$ level with parameters $Δm_{14}^2=(7.3\pm0.13_{st}\pm1.16_{sys})\text{eV}^2 = (7.3\pm1.17)\text{eV}^2$ and $\sin^22θ_{14}= 0.36\pm0.12_{stat}(2.9σ)$. Monte Carlo based statistical analysis gave estimation of confidence level at $2.7σ$. We plan to improve the currently working experimental setup and create a completely new setup in order to increase the accuracy of the experiment by 3 times. We also provide a brief analysis of the general experimental situation in the search for sterile neutrinos.
△ Less
Submitted 25 May, 2021; v1 submitted 9 May, 2020;
originally announced May 2020.
-
Measurement of the neutron electric dipole moment via spin rotation in a non-centrosymmetric crystal
Authors:
V. V. Fedorov,
M. Jentschel,
I. A. Kuznetsov,
E. G. Lapin,
E. Lelievre-Berna,
V. Nesvizhevsky,
A. Petoukhov,
S. Yu. Semenikhin,
T. Soldner,
V. V. Voronin,
Yu. P. Braginetz
Abstract:
We have measured the neutron electric dipole moment using spin rotation in a non-centrosymmetric crystal. Our result is d_n = (2.5 +- 6.5(stat) +- 5.5(syst)) 10^{-24} e cm. The dominating contribution to the systematic uncertainty is statistical in nature and will reduce with improved statistics. The statistical sensitivity can be increased to 2 10^{-26} e cm in 100 days data taking with an improv…
▽ More
We have measured the neutron electric dipole moment using spin rotation in a non-centrosymmetric crystal. Our result is d_n = (2.5 +- 6.5(stat) +- 5.5(syst)) 10^{-24} e cm. The dominating contribution to the systematic uncertainty is statistical in nature and will reduce with improved statistics. The statistical sensitivity can be increased to 2 10^{-26} e cm in 100 days data taking with an improved setup. We state technical requirements for a systematic uncertainty at the same level.
△ Less
Submitted 1 September, 2010;
originally announced September 2010.
-
Measurement of the neutron electric dipole moment by crystal diffraction
Authors:
V. V. Fedorov,
M. Jentschel,
I. A. Kuznetsov,
E. G. Lapin,
E. Lelievre-Berna,
V. Nesvizhevsky,
A. Petoukhov,
S. Yu. Semenikhin,
T. Soldner,
F. Tasset,
V. V. Voronin,
Yu. P. Braginetz
Abstract:
An experiment using a prototype setup to search for the neutron electric dipole moment by measuring spin-rotation in a non-centrosymmetric crystal (quartz) was carried out to investigate statistical sensitivity and systematic effects of the method. It has been demonstrated that the concept of the method works. The preliminary result of the experiment is $d_{\rm n}=(2.5\pm 6.5)\cdot 10^{-24}$ e…
▽ More
An experiment using a prototype setup to search for the neutron electric dipole moment by measuring spin-rotation in a non-centrosymmetric crystal (quartz) was carried out to investigate statistical sensitivity and systematic effects of the method. It has been demonstrated that the concept of the method works. The preliminary result of the experiment is $d_{\rm n}=(2.5\pm 6.5)\cdot 10^{-24}$ e$\cdot $cm. The experiment showed that an accuracy of $\sim 2.5\cdot 10^{-26}$ e$\cdot $cm can be obtained in 100 days data taking, using available quartz crystals and neutron beams.
△ Less
Submitted 9 July, 2009; v1 submitted 7 July, 2009;
originally announced July 2009.
-
Test experiment to search for a neutron EDM by the Laue diffraction method
Authors:
V. V. Fedorov,
E. G. Lapin,
E. Lelievre-Berna,
V. Nesvizhevsky,
A. Petoukhov,
S. Yu. Semenikhin,
T. Soldner,
F. Tasset,
V. V. Voronin
Abstract:
A prototype experiment to measure the neutron electric dipole moment (nEDM) by spin-rotation in a non-centrosymmetric crystal in Laue geometry was carried out in order to investigate the statistical sensitivity and systematic effects of the method. The statistical sensitivity to the nEDM was about $6\cdot 10^{-24}$ e$\cdot $cm per day and can be improved by one order of magnitude for the full sc…
▽ More
A prototype experiment to measure the neutron electric dipole moment (nEDM) by spin-rotation in a non-centrosymmetric crystal in Laue geometry was carried out in order to investigate the statistical sensitivity and systematic effects of the method. The statistical sensitivity to the nEDM was about $6\cdot 10^{-24}$ e$\cdot $cm per day and can be improved by one order of magnitude for the full scale setup. Systematics was limited by the homogeneity of the magnetic field in the crystal region and by a new kind of spin rotation effect. We attribute this effect to a difference of the two Bloch waves amplitudes in the crystal, which is caused by the presence of a small crystal deformation due to a temperature gradient. In a revised scheme of the experiment, this effect could be exploited for a purposeful manipulation of the Bloch waves.
△ Less
Submitted 23 December, 2005;
originally announced December 2005.
-
Neutron Diffraction and Optics of a Noncentrosymmetric Crystal. New Feasibility of a Search for Neutron EDM
Authors:
V. V. Fedorov,
V. V. Voronin
Abstract:
Recently strong electric fields (up to 10^9 V/cm) have been discovered, which affect the neutrons moving in noncentrosymmetric crystals. Such fields allow new polarization phenomena in neutron diffraction and optics and provide, for instance, a new feasibility of a search for the neutron electric dipole moment (EDM). A series of experiments was carried out in a few last years on study of the dyn…
▽ More
Recently strong electric fields (up to 10^9 V/cm) have been discovered, which affect the neutrons moving in noncentrosymmetric crystals. Such fields allow new polarization phenomena in neutron diffraction and optics and provide, for instance, a new feasibility of a search for the neutron electric dipole moment (EDM). A series of experiments was carried out in a few last years on study of the dynamical diffraction of polarized neutrons in thick (1-10 cm) quartz crystals, using the forward diffraction beam and Bragg angles close to 90^0. As well new neutron optics phenomena were investigated. The feasibility of experiment on a search for neutron EDM using Laue diffraction in crystals without a center of symmetry was tested at the reactors: WWR-M in Gatchina and HFR in Grenoble. It was shown that the sensitivity can reach (3 - 6)\cdot 10^{-25}e cm per day for the available quartz crystal and cold neutron beam flux.
△ Less
Submitted 3 May, 2005; v1 submitted 25 April, 2005;
originally announced April 2005.