An extreme thermal cycling reliability test of ATLAS ITk Strips barrel modules
Authors:
A. Tishelman-Charny,
A. Affolder,
F. Capocasa,
E. Duden,
V. Fadeyev,
M. Gignac,
C. Helling,
H. Herde,
J. Johnson,
D. Lynn,
M. Morii,
A. Mitra,
L. Poley,
G. Sciolla,
S. Stucci,
P. Sharma,
G. Van Nieuwenhuizen,
E. Wallin,
A. Wang,
S. Wonsak
Abstract:
At the end of Run 3 of the Large Hadron Collider (LHC), the accelerator complex will be upgraded to the High-Luminosity LHC (HL-LHC) in order to increase the total amount of data provided to its experiments. To cope with the increased rates of data, radiation, and pileup, the ATLAS detector will undergo a substantial upgrade, including a replacement of the Inner Detector with a future Inner Tracke…
▽ More
At the end of Run 3 of the Large Hadron Collider (LHC), the accelerator complex will be upgraded to the High-Luminosity LHC (HL-LHC) in order to increase the total amount of data provided to its experiments. To cope with the increased rates of data, radiation, and pileup, the ATLAS detector will undergo a substantial upgrade, including a replacement of the Inner Detector with a future Inner Tracker, called the ITk. The ITk will be composed of pixel and strip sub-detectors, where the strips portion will be composed of 17,888 silicon strip detector modules. During the HL-LHC running period, the ITk will be cooled and warmed a number of times from about ${-35}^\circ$C to room temperature as part of the operational cycle, including warm-ups during yearly shutdowns. To ensure ITk Strips modules are functional after these expected temperature changes, and to ensure modules are mechanically robust, each module must undergo ten thermal cycles and pass a set of electrical and mechanical criteria before it is placed on a local support structure. This paper describes the thermal cycling Quality Control (QC) procedure, and results from the barrel pre-production phase (about 5% of the production volume). Additionally, in order to assess the headroom of the nominal QC procedure of 10 cycles and to ensure modules don't begin failing soon after, four representative ITk Strips barrel modules were thermally cycled 100 times - this study is also described.
△ Less
Submitted 8 July, 2024;
originally announced July 2024.
-
Characterizing Novel Indium Phosphide Pad Detectors with Focused X-ray Beams and Laboratory Tests
Authors:
Earl Almazan,
Anthony Affolder,
Ian Dyckes,
Vitaliy Fadeyev,
Michael Hance,
Manoj Jadhav,
Sungjoon Kim,
Thomas McCoy,
Jessica Metcalfe,
Jason Nielsen,
Jennifer Ott,
Luise Poley,
Taylor Shin,
Dennis Sperlich,
Anirudha V. Sumant
Abstract:
Future tracking systems in High Energy Physics experiments will require large instrumented areas with low radiation length. Crystalline silicon sensors have been used in tracking systems for decades, but are difficult to manufacture and costly to produce for large areas. We are exploring alternative sensor materials that are amenable to fast fabrication techniques used for thin film devices. Indiu…
▽ More
Future tracking systems in High Energy Physics experiments will require large instrumented areas with low radiation length. Crystalline silicon sensors have been used in tracking systems for decades, but are difficult to manufacture and costly to produce for large areas. We are exploring alternative sensor materials that are amenable to fast fabrication techniques used for thin film devices. Indium Phosphide pad sensors were fabricated at Argonne National Lab using commercially available InP:Fe 2-inch mono-crystal substrates. Current-voltage and capacitance-voltage characterizations were performed to study the basic operating characteristics of a group of sensors. Micro-focused X-ray beams at Canadian Light Source and Diamond Light Source were used to study the response to ionizing radiation, and characterize the uniformity of the response for several devices. The results show a high degree of performance uniformity in our evaluations, both within a device and between the 48 tested devices. This motivates further studies into thin film devices for future tracking detectors.
△ Less
Submitted 10 July, 2024; v1 submitted 29 May, 2024;
originally announced May 2024.
-
Setups for eliminating static charge of the ATLAS18 strip sensors
Authors:
P. Federicova,
A. Affolder,
G. A. Beck,
A. J. Bevand,
Z. Chen,
I. Dawson,
A. Deshmukh,
A. Dowling,
V. Fadeyev,
J. Fernandez-Tejero,
A. Fournier,
N. Gonzalez,
L. Hommels,
C. Jessiman,
S. Kachiguin,
Ch. Klein,
T. Koffas,
J. Kroll,
V. Latonova,
M. Mikestikova,
P. S. Miyagawa,
S. O'Toole,
Q. Paddock,
L. Poley,
E. Staats
, et al. (5 additional authors not shown)
Abstract:
Construction of the new all-silicon Inner Tracker (ITk), developed by the ATLAS collaboration for the High Luminosity LHC, started in 2020 and is expected to continue till 2028. The ITk detector will include 18,000 highly segmented and radiation hard n+-in-p silicon strip sensors (ATLAS18), which are being manufactured by Hamamatsu Photonics. Mechanical and electrical characteristics of produced s…
▽ More
Construction of the new all-silicon Inner Tracker (ITk), developed by the ATLAS collaboration for the High Luminosity LHC, started in 2020 and is expected to continue till 2028. The ITk detector will include 18,000 highly segmented and radiation hard n+-in-p silicon strip sensors (ATLAS18), which are being manufactured by Hamamatsu Photonics. Mechanical and electrical characteristics of produced sensors are measured upon their delivery at several institutes participating in a complex Quality Control (QC) program. The QC tests performed on each individual sensor check the overall integrity and quality of the sensor. During the QC testing of production ATLAS18 strip sensors, an increased number of sensors that failed the electrical tests was observed. In particular, IV measurements indicated an early breakdown, while large areas containing several tens or hundreds of neighbouring strips with low interstrip isolation were identified by the Full strip tests, and leakage current instabilities were measured in a long-term leakage current stability setup. Moreover, a high surface electrostatic charge reaching a level of several hundreds of volts per inch was measured on a large number of sensors and on the plastic sheets, which mechanically protect these sensors in their paper envelopes. Accumulated data indicates a clear correlation between observed electrical failures and the sensor charge-up. To mitigate the above-described issues, the QC testing sites significantly modified the sensor handling procedures and introduced sensor recovery techniques based on irradiation of the sensor surface with UV light or application of intensive flows of ionized gas. In this presentation, we will describe the setups implemented by the QC testing sites to treat silicon strip sensors affected by static charge and evaluate the effectiveness of these setups in terms of improvement of the sensor performance.
△ Less
Submitted 18 December, 2023; v1 submitted 27 September, 2023;
originally announced September 2023.
-
Searching for Prompt and Long-Lived Dark Photons in Electro-Produced $e^+e^-$ Pairs with the Heavy Photon Search Experiment at JLab
Authors:
P. H. Adrian,
N. A. Baltzell,
M. Battaglieri,
M. Bondi,
S. Boyarinov,
C. Bravo,
S. Bueltmann,
P. Butti,
V. D. Burkert,
D. Calvo,
T. Cao,
M. Carpinelli,
A. Celentano,
G. Charles,
L. Colaneri,
W. Cooper,
C. Cuevas,
A. D'Angelo,
N. Dashyan,
M. De Napoli,
R. De Vita,
A. Deur,
M. Diamond,
R. Dupre,
H. Egiyan
, et al. (59 additional authors not shown)
Abstract:
The Heavy Photon Search experiment (HPS) at the Thomas Jefferson National Accelerator Facility searches for electro-produced dark photons. We report results from the 2016 Engineering Run consisting of 10608/nb of data for both the prompt and displaced vertex searches. A search for a prompt resonance in the $e^+e^-$ invariant mass distribution between 39 and 179 MeV showed no evidence of dark photo…
▽ More
The Heavy Photon Search experiment (HPS) at the Thomas Jefferson National Accelerator Facility searches for electro-produced dark photons. We report results from the 2016 Engineering Run consisting of 10608/nb of data for both the prompt and displaced vertex searches. A search for a prompt resonance in the $e^+e^-$ invariant mass distribution between 39 and 179 MeV showed no evidence of dark photons above the large QED background, limiting the coupling of ε^2 {\geq} 10^-5, in agreement with previous searches. The search for displaced vertices showed no evidence of excess signal over background in the masses between 60 and 150 MeV, but had insufficient luminosity to limit canonical heavy photon production. This is the first displaced vertex search result published by HPS. HPS has taken high-luminosity data runs in 2019 and 2021 that will explore new dark photon phase space.
△ Less
Submitted 12 July, 2023; v1 submitted 20 December, 2022;
originally announced December 2022.
-
The Heavy Photon Search Experiment
Authors:
Nathan Baltzell,
Marco Battaglieri,
Mariangela Bondi,
Sergei Boyarinov,
Cameron Bravo,
Stephen Bueltmann,
Volker Burkert,
Pierfrancesco Butti,
Tongtong Cao,
Massimo Carpinelli,
Andrea Celentano,
Gabriel Charles,
Chris Cuevas,
Annalisa D'Angelo,
Domenico D'Urso,
Natalia Dashyan,
Marzio De Napoli,
Raffaella De Vita,
Alexandre Deur,
Miriam Diamond,
Raphael Dupre,
Rouven Essig,
Vitaliy Fadeyev,
R. Clive Field,
Alessandra Filippi
, et al. (37 additional authors not shown)
Abstract:
The Heavy Photon Search (HPS) experiment is designed to search for a new vector boson $A^\prime$ in the mass range of 20 MeV/$c^2$ to 220 MeV/$c^2$ that kinetically mixes with the Standard Model photon with couplings $ε^2 >10^{-10}$. In addition to the general importance of exploring light, weakly coupled physics that is difficult to probe with high-energy colliders, a prime motivation for this se…
▽ More
The Heavy Photon Search (HPS) experiment is designed to search for a new vector boson $A^\prime$ in the mass range of 20 MeV/$c^2$ to 220 MeV/$c^2$ that kinetically mixes with the Standard Model photon with couplings $ε^2 >10^{-10}$. In addition to the general importance of exploring light, weakly coupled physics that is difficult to probe with high-energy colliders, a prime motivation for this search is the possibility that sub-GeV thermal relics constitute dark matter, a scenario that requires a new comparably light mediator, where models with a hidden $U(1)$ gauge symmetry, a "dark", "hidden sector", or "heavy" photon, are particularly attractive. HPS searches for visible signatures of these heavy photons, taking advantage of their small coupling to electric charge to produce them via a process analogous to bremsstrahlung in a fixed target and detect their subsequent decay to $\mathrm{e}^+ \mathrm{e}^-$ pairs in a compact spectrometer. In addition to searching for $\mathrm{e}^+ \mathrm{e}^-$ resonances atop large QED backgrounds, HPS has the ability to precisely measure decay lengths, resulting in unique sensitivity to dark photons, as well as other long-lived new physics. After completion of the experiment and operation of engineering runs in 2015 and 2016 at the JLab CEBAF, physics runs in 2019 and 2021 have provided datasets that are now being analyzed to search for dark photons and other new phenomena.
△ Less
Submitted 15 March, 2022;
originally announced March 2022.
-
Map** the in-plane electric field inside irradiated diodes
Authors:
L. Poley,
A. J. Blue,
C. Buttar,
V. Cindro,
C. Darroch,
V. Fadeyev,
J. Fernandez-Tejero,
C. Fleta,
C. Helling,
C. Labitan,
I. Mandić,
S. N. Santpur,
D. Sperlich,
M. Ullán,
Y. Unno
Abstract:
A significant aspect of the Phase-II Upgrade of the ATLAS detector is the replacement of the current Inner Detector with the ATLAS Inner Tracker (ITk). The ATLAS ITk is an all-silicon detector consisting of a pixel tracker and a strip tracker. Sensors for the ITk strip tracker have been developed to withstand the high radiation environment in the ATLAS detector after the High Luminosity Upgrade of…
▽ More
A significant aspect of the Phase-II Upgrade of the ATLAS detector is the replacement of the current Inner Detector with the ATLAS Inner Tracker (ITk). The ATLAS ITk is an all-silicon detector consisting of a pixel tracker and a strip tracker. Sensors for the ITk strip tracker have been developed to withstand the high radiation environment in the ATLAS detector after the High Luminosity Upgrade of the Large Hadron Collider at CERN, which will significantly increase the rate of particle collisions and resulting particle tracks. During their operation in the ATLAS detector, sensors for the ITk strip tracker are expected to accumulate fluences up to 1.6 x 10^15 n_eq/cm^2 (including a safety factor of 1.5), which will significantly affect their performance. One characteristic of interest for highly irradiated sensors is the shape and homogeneity of the electric field inside its active area. For the results presented here, diodes with edge structures similar to full size ATLAS sensors were irradiated up to fluences comparable to those in the ATLAS ITk strip tracker and their electric fields mapped using a micro-focused X-ray beam (beam diameter 2x3 μm^2). This study shows the extension and shape of the electric field inside highly irradiated diodes over a range of applied bias voltages. Additionally, measurements of the outline of the depleted sensor areas allow a comparison of the measured leakage current for different fluences with expectations for the corresponding active areas.
△ Less
Submitted 29 March, 2021;
originally announced March 2021.
-
The ABC130 barrel module prototy** programme for the ATLAS strip tracker
Authors:
Luise Poley,
Craig Sawyer,
Sagar Addepalli,
Anthony Affolder,
Bruno Allongue,
Phil Allport,
Eric Anderssen,
Francis Anghinolfi,
Jean-François Arguin,
Jan-Hendrik Arling,
Olivier Arnaez,
Nedaa Alexandra Asbah,
Joe Ashby,
Eleni Myrto Asimakopoulou,
Naim Bora Atlay,
Ludwig Bartsch,
Matthew J. Basso,
James Beacham,
Scott L. Beaupré,
Graham Beck,
Carl Beichert,
Laura Bergsten,
Jose Bernabeu,
Prajita Bhattarai,
Ingo Bloch
, et al. (224 additional authors not shown)
Abstract:
For the Phase-II Upgrade of the ATLAS Detector, its Inner Detector, consisting of silicon pixel, silicon strip and transition radiation sub-detectors, will be replaced with an all new 100 % silicon tracker, composed of a pixel tracker at inner radii and a strip tracker at outer radii. The future ATLAS strip tracker will include 11,000 silicon sensor modules in the central region (barrel) and 7,000…
▽ More
For the Phase-II Upgrade of the ATLAS Detector, its Inner Detector, consisting of silicon pixel, silicon strip and transition radiation sub-detectors, will be replaced with an all new 100 % silicon tracker, composed of a pixel tracker at inner radii and a strip tracker at outer radii. The future ATLAS strip tracker will include 11,000 silicon sensor modules in the central region (barrel) and 7,000 modules in the forward region (end-caps), which are foreseen to be constructed over a period of 3.5 years. The construction of each module consists of a series of assembly and quality control steps, which were engineered to be identical for all production sites. In order to develop the tooling and procedures for assembly and testing of these modules, two series of major prototy** programs were conducted: an early program using readout chips designed using a 250 nm fabrication process (ABCN-25) and a subsequent program using a follow-up chip set made using 130 nm processing (ABC130 and HCC130 chips). This second generation of readout chips was used for an extensive prototy** program that produced around 100 barrel-type modules and contributed significantly to the development of the final module layout. This paper gives an overview of the components used in ABC130 barrel modules, their assembly procedure and findings resulting from their tests.
△ Less
Submitted 7 September, 2020;
originally announced September 2020.
-
Search for a Dark Photon in Electro-Produced $e^{+}e^{-}$ Pairs with the Heavy Photon Search Experiment at JLab
Authors:
P. H. Adrian,
N. A. Baltzell,
M. Battaglieri,
M. Bondí,
S. Boyarinov,
S. Bueltmann,
V. D. Burkert,
D. Calvo,
M. Carpinelli,
A. Celentano,
G. Charles,
L. Colaneri,
W. Cooper,
C. Cuevas,
A. D'Angelo,
N. Dashyan,
M. De Napoli,
R. De Vita,
A. Deur,
R. Dupre,
H. Egiyan,
L. Elouadrhiri,
R. Essig,
V. Fadeyev,
C. Field
, et al. (52 additional authors not shown)
Abstract:
The Heavy Photon Search experiment took its first data in a 2015 engineering run using a 1.056 GeV, 50 nA electron beam provided by CEBAF at the Thomas Jefferson National Accelerator Facility, searching for an electro-produced dark photon. Using 1.7 days (1170 nb$^{-1}$) of data, a search for a resonance in the $e^{+}e^{-}$ invariant mass distribution between 19 and 81 MeV/c$^2$ showed no evidence…
▽ More
The Heavy Photon Search experiment took its first data in a 2015 engineering run using a 1.056 GeV, 50 nA electron beam provided by CEBAF at the Thomas Jefferson National Accelerator Facility, searching for an electro-produced dark photon. Using 1.7 days (1170 nb$^{-1}$) of data, a search for a resonance in the $e^{+}e^{-}$ invariant mass distribution between 19 and 81 MeV/c$^2$ showed no evidence of dark photon decays above the large QED background, confirming earlier searches and demonstrating the full functionality of the experiment. Upper limits on the square of the coupling of the dark photon to the Standard Model photon are set at the level of 6$\times$10$^{-6}$. In addition, a search for displaced dark photon decays did not rule out any territory but resulted in a reliable analysis procedure that will probe hitherto unexplored parameter space with future, higher luminosity runs.
△ Less
Submitted 5 December, 2018;
originally announced December 2018.
-
Map** the depleted area of silicon diodes using a micro-focused X-ray beam
Authors:
Luise Poley,
Andrew Blue,
Ingo Bloch,
Craig Buttar,
Vitaliy Fadeyev,
Javier Fernandez-Tejero,
Celeste Fleta,
Johannes Hacker,
Carlos Lacasta Llacer,
Mercedes Miñano,
Martin Renzmann,
Edoardo Rossi,
Craig Sawyer,
Dennis Sperlich,
Martin Stegler,
Miguel Ullán,
Yoshinobu Unno
Abstract:
For the Phase-II Upgrade of the ATLAS detector at CERN, the current ATLAS Inner Detector will be replaced with the ATLAS Inner Tracker. The ATLAS Inner Tracker will be an all-silicon detector, consisting of a pixel tracker and a strip tracker. Sensors for the ITk strip tracker are required to have a low leakage current up to bias voltages of -700 V to maintain a low noise and power dissipation. In…
▽ More
For the Phase-II Upgrade of the ATLAS detector at CERN, the current ATLAS Inner Detector will be replaced with the ATLAS Inner Tracker. The ATLAS Inner Tracker will be an all-silicon detector, consisting of a pixel tracker and a strip tracker. Sensors for the ITk strip tracker are required to have a low leakage current up to bias voltages of -700 V to maintain a low noise and power dissipation. In order to minimise sensor leakage currents, particularly in the high-radiation environment inside the ATLAS detector, sensors are foreseen to be operated at low temperatures and to be manufactured from wafers with a high bulk resistivity of several kΩ cm. Simulations showed the electric field inside sensors with high bulk resistivity to extend towards the sensor edge, which could lead to increased surface currents for narrow dicing edges. In order to map the electric field inside biased silicon sensors with high bulk resistivity, three diodes from ATLAS silicon strip sensor prototype wafers were studied with a monochromatic, micro-focused X-ray beam at the Diamond Light Source. For all devices under investigation, the electric field inside the diode was mapped and its dependence on the applied bias voltage was studied. The findings showed that the electric field in each diode under investigation extended beyond its bias ring and reached the dicing edge.
△ Less
Submitted 27 March, 2019; v1 submitted 7 September, 2018;
originally announced September 2018.
-
Search for a Dark Photon in Electro-Produced $e^{+}e^{-}$ Pairs with the Heavy Photon Search Experiment at JLab
Authors:
P. H. Adrian,
N. A. Baltzell,
M. Battaglieri,
M. Bondí,
S. Boyarinov,
S. Bueltmann,
V. D. Burkert,
D. Calvo,
M. Carpinelli,
A. Celentano,
G. Charles,
L. Colaneri,
W. Cooper,
C. Cuevas,
A. D'Angelo,
N. Dashyan,
M. De Napoli,
R. De Vita,
A. Deur,
R. Dupre,
H. Egiyan,
L. Elouadrhiri,
R. Essig,
V. Fadeyev,
C. Field
, et al. (52 additional authors not shown)
Abstract:
The Heavy Photon Search experiment took its first data in a 2015 engineering run at the Thomas Jefferson National Accelerator Facility, searching for a prompt, electro-produced dark photon with a mass between 19 and 81 MeV/$c^2$. A search for a resonance in the $e^{+}e^{-}$ invariant mass distribution, using 1.7 days (1170 nb$^{-1}$) of data, showed no evidence of dark photon decays above the larg…
▽ More
The Heavy Photon Search experiment took its first data in a 2015 engineering run at the Thomas Jefferson National Accelerator Facility, searching for a prompt, electro-produced dark photon with a mass between 19 and 81 MeV/$c^2$. A search for a resonance in the $e^{+}e^{-}$ invariant mass distribution, using 1.7 days (1170 nb$^{-1}$) of data, showed no evidence of dark photon decays above the large QED background, confirming earlier searches and demonstrating the full functionality of the experiment. Upper limits on the square of the coupling of the dark photon to the Standard Model photon are set at the level of 6$\times$10$^{-6}$. Future runs with higher luminosity will explore new territory.
△ Less
Submitted 3 August, 2018; v1 submitted 30 July, 2018;
originally announced July 2018.
-
Radiation Hardness of Thin Low Gain Avalanche Detectors
Authors:
G. Kramberger,
M. Carulla,
E. Cavallaro,
V. Cindro,
D. Flores,
Z. Galloway,
S. Grinstein,
S. Hidalgo,
V. Fadeyev,
J. Lange,
I. Mandic,
G. Medin,
A. Merlos,
F. McKinney-Martinez,
M. Mikuz,
D. Quirion,
G. Pellegrini,
M. Petek,
H. F-W. Sadrozinski,
A. Seiden,
M. Zavrtanik
Abstract:
Low Gain Avalanche Detectors (LGAD) are based on a n++-p+-p-p++ structure where an appropriate do** of the multiplication layer (p+) leads to high enough electric fields for impact ionization. Gain factors of few tens in charge significantly improve the resolution of timing measurements, particularly for thin detectors, where the timing performance was shown to be limited by Landau fluctuations.…
▽ More
Low Gain Avalanche Detectors (LGAD) are based on a n++-p+-p-p++ structure where an appropriate do** of the multiplication layer (p+) leads to high enough electric fields for impact ionization. Gain factors of few tens in charge significantly improve the resolution of timing measurements, particularly for thin detectors, where the timing performance was shown to be limited by Landau fluctuations. The main obstacle for their operation is the decrease of gain with irradiation, attributed to effective acceptor removal in the gain layer. Sets of thin sensors were produced by two different producers on different substrates, with different gain layer do** profiles and thicknesses (45, 50 and 80 um). Their performance in terms of gain/collected charge and leakage current was compared before and after irradiation with neutrons and pions up to the equivalent fluences of 5e15 cm-2. Transient Current Technique and charge collection measurements with LHC speed electronics were employed to characterize the detectors. The thin LGAD sensors were shown to perform much better than sensors of standard thickness (~300 um) and offer larger charge collection with respect to detectors without gain layer for fluences <2e15 cm-2. Larger initial gain prolongs the beneficial performance of LGADs. Pions were found to be more damaging than neutrons at the same equivalent fluence, while no significant difference was found between different producers. At very high fluences and bias voltages the gain appears due to deep acceptors in the bulk, hence also in thin standard detectors.
△ Less
Submitted 16 November, 2017;
originally announced November 2017.
-
Properties of HPK UFSD after neutron irradiation up to 6e15 n/cm2
Authors:
Z. Galloway,
V. Fadeyev,
P. Freeman,
E. Gkougkousis,
B. Gruey,
C. A. Labitan,
Z. Luce,
F. McKinney-Martinez,
H. F. -W. Sadrozinski,
A. Seiden,
E. Spencer,
M. Wilder,
N. Woods,
A. Zatserklyaniy,
Y. Zhao,
N. Cartiglia,
M. Ferrero,
S. Giordanengo,
M. Mandurrino,
A. Staiano,
V. Sola,
F. Cenna,
F. Fausti,
R. Arcidiacono,
F. Carnasecchi
, et al. (5 additional authors not shown)
Abstract:
In this paper we report results from a neutron irradiation campaign of Ultra-Fast Silicon Detectors (UFSD) with fluences of 1e14, 3e14, 6e14, 1e15, 3e15, 6e15 n/cm2. The UFSD used in this study are circular 50 micro-meter thick Low-Gain Avalanche Detectors (LGAD), with a 1.0 mm diameter active area. They have been produced by Hamamatsu Photonics (HPK), Japan, with pre-radiation internal gain in th…
▽ More
In this paper we report results from a neutron irradiation campaign of Ultra-Fast Silicon Detectors (UFSD) with fluences of 1e14, 3e14, 6e14, 1e15, 3e15, 6e15 n/cm2. The UFSD used in this study are circular 50 micro-meter thick Low-Gain Avalanche Detectors (LGAD), with a 1.0 mm diameter active area. They have been produced by Hamamatsu Photonics (HPK), Japan, with pre-radiation internal gain in the range 10-100 depending on the bias voltage. The sensors were tested pre-irradiation and post-irradiation with minimum ionizing particle (MIPs) from a 90Sr based \b{eta}-source. The leakage current, internal gain and the timing resolution were measured as a function of bias voltage at -20C and -30C. The timing resolution was extracted from the time difference with a second calibrated UFSD in coincidence, using the constant fraction method for both. The dependence of the gain upon the irradiation fluence is consistent with the concept of acceptor removal and the gain decreases from about 80 pre-irradiation to 7 after a fluence of 6e15 n/cm2. Consequently, the timing resolution was found to deteriorate from 20 ps to 50 ps. The results indicate that the most accurate time resolution is obtained at a value of the constant fraction discriminator (CFD) threshold used to determine the time of arrival varying with fluence, from 10% pre-radiation to 60% at the highest fluence. Key changes to the pulse shape induced by irradiation, i.e. (i) a reduce sensitivity of the pulse shape on the initial non-uniform charge deposition, (ii) the shortening of the rise time and (iii) the reduced pulse height, were compared with the WF2 simulation program and found to be in agreement.
△ Less
Submitted 10 April, 2020; v1 submitted 16 July, 2017;
originally announced July 2017.
-
Beam test results of a 16 ps timing system based on ultra-fast silicon detectors
Authors:
N. Cartiglia,
A. Staiano,
V. Sola,
R. Arcidiacono,
R. Cirio,
F. Cenna,
M. Ferrero,
V. Monaco,
R. Mulargia,
M. Obertino,
F. Ravera,
R. Sacchi,
A. Bellora,
S. Durando,
M. Mandurrino,
N. Minafra,
V. Fadeyev,
P. Freeman,
Z. Galloway,
E. Gkougkousis,
H. Grabas,
B. Gruey,
C. A. Labitan,
R. Losakul,
Z. Luce
, et al. (18 additional authors not shown)
Abstract:
In this paper we report on the timing resolution of the first production of 50 micro-meter thick Ultra-Fast Silicon Detectors (UFSD) as obtained in a beam test with pions of 180 GeV/c momentum. UFSD are based on the Low-Gain Avalanche Detectors (LGAD) design, employing n-on-p silicon sensors with internal charge multiplication due to the presence of a thin, low-resistivity diffusion layer below th…
▽ More
In this paper we report on the timing resolution of the first production of 50 micro-meter thick Ultra-Fast Silicon Detectors (UFSD) as obtained in a beam test with pions of 180 GeV/c momentum. UFSD are based on the Low-Gain Avalanche Detectors (LGAD) design, employing n-on-p silicon sensors with internal charge multiplication due to the presence of a thin, low-resistivity diffusion layer below the junction. The UFSD used in this test belongs to the first production of thin (50 μm) sensors, with an pad area of 1.4 mm2. The gain was measured to vary between 5 and 70 depending on the bias voltage. The experimental setup included three UFSD and a fast trigger consisting of a quartz bar readout by a SiPM. The timing resolution, determined comparing the time of arrival of the particle in one or more UFSD and the trigger counter, for single UFSD was measured to be 35 ps for a bias voltage of 200 V, and 26 ps for a bias voltage of 240 V, and for the combination of 3 UFSD to be 20 ps for a bias voltage of 200 V, and 15 ps for a bias voltage of 240 V.
△ Less
Submitted 3 January, 2017; v1 submitted 30 August, 2016;
originally announced August 2016.
-
Recent Technological Developments on LGAD and iLGAD Detectors for Tracking and Timing Applications
Authors:
G. Pellegrini,
M. Baselga,
M. Carulla,
V. Fadeyev,
P. Fernandez-Martinez,
M. Fernandez-Garcia,
D. Flores,
Z. Galloway,
C. Gallrapp,
S. Hidalgo,
Z. Liang,
A. Merlos,
M. Moll,
D. Quirion,
H. Sadrozinski,
M. Stricker,
I. Vila
Abstract:
This paper reports the last technological development on the Low Gain Avalanche Detector (LGAD) and introduces a new architecture of these detectors called inverse-LGAD (iLGAD). Both approaches are based on the standard Avalanche Photo Diodes (APD) concept, commonly used in optical and X-ray detection applications, including an internal multiplication of the charge generated by radiation. The mult…
▽ More
This paper reports the last technological development on the Low Gain Avalanche Detector (LGAD) and introduces a new architecture of these detectors called inverse-LGAD (iLGAD). Both approaches are based on the standard Avalanche Photo Diodes (APD) concept, commonly used in optical and X-ray detection applications, including an internal multiplication of the charge generated by radiation. The multiplication is inherent to the basic n++-p+-p structure, where the do** profile of the p+ layer is optimized to achieve high field and high impact ionization at the junction. The LGAD structures are optimized for applications such as tracking or timing detectors for high energy physics experiments or medical applications where time resolution lower than 30 ps is required. Detailed TCAD device simulations together with the electrical and charge collection measurements are presented through this work.
△ Less
Submitted 23 November, 2015;
originally announced November 2015.
-
The Heavy Photon Search Test Detector
Authors:
Marco Battaglieri,
Sergey Boyarinov,
Stephen Bueltmann,
Volker Burkert,
Andrea Celentano,
Gabriel Charles,
William Cooper,
Chris Cuevas,
Natalia Dashyan,
Raffaella DeVita,
Camille Desnault,
Alexandre Deur,
Hovanes Egiyan,
Latifa Elouadrhiri,
Rouven Essig,
Vitaliy Fadeyev,
Clive Field,
Arne Freyberger,
Yuri Gershtein,
Nerses Gevorgyan,
Francois-Xavier Girod,
Norman Graf,
Mathew Graham,
Keith Griffioen,
Alexander Grillo
, et al. (39 additional authors not shown)
Abstract:
The Heavy Photon Search (HPS), an experiment to search for a hidden sector photon in fixed target electroproduction, is preparing for installation at the Thomas Jefferson National Accelerator Facility (JLab) in the Fall of 2014. As the first stage of this project, the HPS Test Run apparatus was constructed and operated in 2012 to demonstrate the experiment's technical feasibility and to confirm th…
▽ More
The Heavy Photon Search (HPS), an experiment to search for a hidden sector photon in fixed target electroproduction, is preparing for installation at the Thomas Jefferson National Accelerator Facility (JLab) in the Fall of 2014. As the first stage of this project, the HPS Test Run apparatus was constructed and operated in 2012 to demonstrate the experiment's technical feasibility and to confirm that the trigger rates and occupancies are as expected. This paper describes the HPS Test Run apparatus and readout electronics and its performance. In this setting, a heavy photon can be identified as a narrow peak in the e$^+$e$^-$ invariant mass spectrum, above the trident background or as a narrow invariant mass peak with a decay vertex displaced from the production target, so charged particle tracking and vertexing are needed for its detection. In the HPS Test Run, charged particles are measured with a compact forward silicon microstrip tracker inside a dipole magnet. Electromagnetic showers are detected in a PbW0$_{4}$ crystal calorimeter situated behind the magnet, and are used to trigger the experiment and identify electrons and positrons. Both detectors are placed close to the beam line and split top-bottom. This arrangement provides sensitivity to low-mass heavy photons, allows clear passage of the unscattered beam, and avoids the spray of degraded electrons coming from the target. The discrimination between prompt and displaced e$^+$e$^-$ pairs requires the first layer of silicon sensors be placed only 10~cm downstream of the target. The expected signal is small, and the trident background huge, so the experiment requires very large statistics. Accordingly, the HPS Test Run utilizes high-rate readout and data acquisition electronics and a fast trigger to exploit the essentially 100% duty cycle of the CEBAF accelerator at JLab.
△ Less
Submitted 4 June, 2015; v1 submitted 23 June, 2014;
originally announced June 2014.
-
Performance of Ultra-Fast Silicon Detectors
Authors:
N. Cartiglia,
M. Baselga,
G. Dellacasa,
S. Ely,
V. Fadeyev,
Z. Galloway,
F. Marchetto,
S. Maroiu,
G. Mazza,
J. Ngo,
M. Obertino,
C. Parker,
A. Rivetti,
D. Shumacher,
H. F-W. Sadrozinski,
A. Seiden,
A. Zatserklyaniy
Abstract:
The development of Low-Gain Avalanche Detectors has opened up the possibility of manufacturing silicon detectors with signal larger than that of traditional sensors. In this paper we explore the timing performance of Low-Gain Avalanche Detectors, and in particular we demonstrate the possibility of obtaining ultra-fast silicon detector with time resolution of less than 20 picosecond.
The development of Low-Gain Avalanche Detectors has opened up the possibility of manufacturing silicon detectors with signal larger than that of traditional sensors. In this paper we explore the timing performance of Low-Gain Avalanche Detectors, and in particular we demonstrate the possibility of obtaining ultra-fast silicon detector with time resolution of less than 20 picosecond.
△ Less
Submitted 5 December, 2013; v1 submitted 4 December, 2013;
originally announced December 2013.
-
The Cleo Rich Detector
Authors:
M. Artuso,
R. Ayad,
K. Bukin,
A. Efimov,
C. Boulahouache,
E. Dambasuren,
S. Kopp,
Ji Li,
G. Majumder,
N. Menaa,
R. Mountain,
S. Schuh,
T. Skwarnicki,
S. Stone,
G. Viehhauser,
J. C. Wang,
T. E. Coan,
V. Fadeyev,
Y. Maravin,
I. Volobouev,
J. Ye,
S. Anderson,
Y. Kubota,
A. Smith
Abstract:
We describe the design, construction and performance of a Ring Imaging Cherenkov Detector (RICH) constructed to identify charged particles in the CLEO experiment. Cherenkov radiation occurs in LiF crystals, both planar and ones with a novel ``sawtooth''-shaped exit surface. Photons in the wavelength interval 135--165 nm are detected using multi-wire chambers filled with a mixture of methane gas…
▽ More
We describe the design, construction and performance of a Ring Imaging Cherenkov Detector (RICH) constructed to identify charged particles in the CLEO experiment. Cherenkov radiation occurs in LiF crystals, both planar and ones with a novel ``sawtooth''-shaped exit surface. Photons in the wavelength interval 135--165 nm are detected using multi-wire chambers filled with a mixture of methane gas and triethylamine vapor. Excellent pion/kaon separation is demonstrated.
△ Less
Submitted 26 July, 2005; v1 submitted 15 June, 2005;
originally announced June 2005.
-
Construction, Pattern Recognition and Performance of the CLEO III LiF-TEA RICH Detector
Authors:
M. Artuso,
R. Ayad,
K. Bukin,
A. Efimov,
C. Boulahouache,
E. Dambasuren,
S. Kopp,
R. Mountain,
G. Majumder,
S. Schuh,
T. Skwarnicki,
S. Stone,
G. Viehhauser,
J. C. Wang,
T. E. Coan,
V. Fadeyev,
Y. Maravin,
I. Volobouev,
J. Ye,
S. Anderson,
Y. Kubota,
A. Smith
Abstract:
We briefly describe the design, construction and performance of the LiF-Tea RICH detector built to identify charged particles in the CLEO III experiment. Excellent pion/kaon separation is demonstrated.
We briefly describe the design, construction and performance of the LiF-Tea RICH detector built to identify charged particles in the CLEO III experiment. Excellent pion/kaon separation is demonstrated.
△ Less
Submitted 13 September, 2002; v1 submitted 6 September, 2002;
originally announced September 2002.
-
The Cleo III Ring Imaging Cherenkov Detector
Authors:
M. Artuso,
R. Ayad,
A. Efimov,
S. Kopp,
G. Majumder,
R. Mountain,
S. Schuh,
T. Skwarnicki,
S. Stone,
G. Viehhauser,
J. Wang,
S. Anderson,
Y. Kubota,
A. Smith,
T. Coan,
V. Fadeyev,
J. Ye
Abstract:
The CLEO detector has been upgraded to include a state of the art particle identification system, based on the Ring Imaging Cherenkov Detector (RICH) technology, in order to take data at the upgraded CESR electron positron collider. The expected performance is reviewed, as well as the preliminary results from an engineering run during the first few months of operation of the CLEO III detector.
The CLEO detector has been upgraded to include a state of the art particle identification system, based on the Ring Imaging Cherenkov Detector (RICH) technology, in order to take data at the upgraded CESR electron positron collider. The expected performance is reviewed, as well as the preliminary results from an engineering run during the first few months of operation of the CLEO III detector.
△ Less
Submitted 4 August, 2000;
originally announced August 2000.
-
Performance of the CLEO III LiF-TEA Ring Imaging Cherenkov Detector in a High Energy Muon Beam
Authors:
M. Artuso,
R. Ayad,
F. Azfar,
A. Efimov,
S. Kopp,
R. Mountain,
G. Majumder,
S. Schuh,
T. Skwarnicki,
S. Stone,
G. Viehhauser,
J. C. Wang,
T. Coan,
V. Fadeyev,
I. Volobouev,
J. Ye,
S. Anderson,
Y. Kubota,
A. Smith,
E. Lipeles
Abstract:
The CLEO III Ring Imaging Cherenkov detector uses LiF radiators to generate Cherenkov photons which are then detected by proportional wire chambers using a mixture of CH$_4$ and TEA gases. The first two photon detector modules which were constructed, were taken to Fermilab and tested in a beam dump that provided high momentum muons. We report on results using both plane and "sawtooth" shaped rad…
▽ More
The CLEO III Ring Imaging Cherenkov detector uses LiF radiators to generate Cherenkov photons which are then detected by proportional wire chambers using a mixture of CH$_4$ and TEA gases. The first two photon detector modules which were constructed, were taken to Fermilab and tested in a beam dump that provided high momentum muons. We report on results using both plane and "sawtooth" shaped radiators. Specifically, we discuss the number of photoelectrons observed per ring and the angular resolution. The particle separation ability is shown to be sufficient for the physics of CLEO III.
△ Less
Submitted 25 October, 1999;
originally announced October 1999.
-
The CLEO-III RICH Detector and Beam Test Results
Authors:
J. C. Wang,
M. Artuso,
R. Ayad,
F. Azfar,
E. Dambasuren,
A. Efimov,
S. Kopp,
G. Majumder,
R. Mountain,
S. Schuh,
T. Skwarnicki,
S. Stone,
G. Viehhauser,
S. Anderson,
A. Smith,
Y. Kubota,
E. Lipeles,
T. Coan,
J. Staeck,
V. Fadeyev,
I. Volobouev,
J. Ye
Abstract:
We are constructing a Ring Imaging Cherenkov detector (RICH) for the CLEO III upgrade for precision charged hadron identification. The RICH uses plane and sawtooth LiF crystals as radiators, MWPCs as photon detectors with TEA as the photo-sensitive material, and low-noise Viking readout electronics. Results of a beam test of the first two out of total 30 sectors are presented.
We are constructing a Ring Imaging Cherenkov detector (RICH) for the CLEO III upgrade for precision charged hadron identification. The RICH uses plane and sawtooth LiF crystals as radiators, MWPCs as photon detectors with TEA as the photo-sensitive material, and low-noise Viking readout electronics. Results of a beam test of the first two out of total 30 sectors are presented.
△ Less
Submitted 29 March, 1999;
originally announced March 1999.
-
The CLEO-III Ring Imaging Cherenkov Detector
Authors:
R. J. Mountain,
M. Artuso,
R. Ayad,
F. Azfar,
A. Efimov,
S. Kopp,
G. Majumder,
S. Schuh,
T. Skwarnicki,
S. Stone,
G. Viehhauser,
S. Anderson,
A. Smith,
Y. Kubota,
E. Lipeles,
T. Coan,
J. Staeck,
V. Fadeyev,
I. Volobouev,
J. Ye
Abstract:
The CLEO-III Detector upgrade for charged particle identification is discussed. The RICH design uses solid LiF crystal radiators coupled with multi-wire chamber photon detectors, using TEA as the photosensor, and low-noise Viking readout electronics. Results from our beam test at Fermilab are presented.
The CLEO-III Detector upgrade for charged particle identification is discussed. The RICH design uses solid LiF crystal radiators coupled with multi-wire chamber photon detectors, using TEA as the photosensor, and low-noise Viking readout electronics. Results from our beam test at Fermilab are presented.
△ Less
Submitted 15 February, 1999;
originally announced February 1999.