First detection of coherent elastic neutrino-nucleus scattering on germanium
Authors:
S. Adamski,
M. Ahn,
P. S. Barbeau,
V. Belov,
I. Bernardi,
C. Bock,
A. Bolozdynya,
R. Bouabid,
J. Browning,
B. Cabrera-Palmer,
N. Cedarblade-Jones,
J. Colón Rivera,
E. Conley,
V. da Silva,
J. Daughhetee,
J. Detwiler,
K. Ding,
M. R. Durand,
Y. Efremenko,
S. R. Elliott,
A. Erlandson,
L. Fabris,
A. Galindo-Uribarri,
M. P. Green,
J. Hakenmüller
, et al. (62 additional authors not shown)
Abstract:
We report the first detection of coherent elastic neutrino-nucleus scattering (CEvNS) on germanium, measured at the Spallation Neutron Source at Oak Ridge National Laboratory. The Ge-Mini detector of the COHERENT collaboration employs large-mass, low-noise, high-purity germanium spectrometers, enabling excellent energy resolution, and an analysis threshold of 1.5 keV electron-equivalent ionization…
▽ More
We report the first detection of coherent elastic neutrino-nucleus scattering (CEvNS) on germanium, measured at the Spallation Neutron Source at Oak Ridge National Laboratory. The Ge-Mini detector of the COHERENT collaboration employs large-mass, low-noise, high-purity germanium spectrometers, enabling excellent energy resolution, and an analysis threshold of 1.5 keV electron-equivalent ionization energy. We observe a on-beam excess of 20.6$_{+7.1}^{-6.3}$ counts with a total exposure of 10.22 GWhkg and we reject the no-CEvNS hypothesis with 3.9 sigma significance. The result agrees with the predicted standard model of particle physics signal rate within 2 sigma.
△ Less
Submitted 19 June, 2024;
originally announced June 2024.
-
Supernova Electron-Neutrino Interactions with Xenon in the nEXO Detector
Authors:
nEXO Collaboration,
S. Hedges,
S. Al Kharusi,
E. Angelico,
J. P. Brodsky,
G. Richardson,
S. Wilde,
A. Amy,
A. Anker,
I. J. Arnquist,
P. Arsenault,
A. Atencio,
I. Badhrees,
J. Bane,
V. Belov,
E. P. Bernard,
T. Bhatta,
A. Bolotnikov,
J. Breslin,
P. A. Breur,
E. Brown,
T. Brunner,
E. Caden,
G. F. Cao,
L. Q. Cao
, et al. (121 additional authors not shown)
Abstract:
Electron-neutrino charged-current interactions with xenon nuclei were modeled in the nEXO neutrinoless double-beta decay detector (~5-tonne, 90% ${}^{136}$Xe, 10% ${}^{134}$Xe) to evaluate its sensitivity to supernova neutrinos. Predictions for event rates and detectable signatures were modeled using the MARLEY event generator. We find good agreement between MARLEY's predictions and existing theor…
▽ More
Electron-neutrino charged-current interactions with xenon nuclei were modeled in the nEXO neutrinoless double-beta decay detector (~5-tonne, 90% ${}^{136}$Xe, 10% ${}^{134}$Xe) to evaluate its sensitivity to supernova neutrinos. Predictions for event rates and detectable signatures were modeled using the MARLEY event generator. We find good agreement between MARLEY's predictions and existing theoretical calculations of the inclusive cross sections at supernova neutrino energies. The interactions modeled by MARLEY were simulated within the nEXO simulation framework and were run through an example reconstruction algorithm to determine the detector's efficiency for reconstructing these events. The simulated data, incorporating the detector response, were used to study the ability of nEXO to reconstruct the incident electron-neutrino spectrum and these results were extended to a larger xenon detector of the same isotope enrichment. We estimate that nEXO will be able to observe electron-neutrino interactions with xenon from supernovae as far as 5 to 8 kpc from earth, while the ability to reconstruct incident electron-neutrino spectrum parameters from observed interactions in nEXO is limited to closer supernovae.
△ Less
Submitted 29 May, 2024;
originally announced May 2024.
-
Accessing new physics with an undoped, cryogenic CsI CEvNS detector for COHERENT at the SNS
Authors:
P. S. Barbeau,
V. Belov,
I. Bernardi,
C. Bock,
A. Bolozdynya,
R. Bouabid,
J. Browning,
B. Cabrera-Palmer,
E. Conley,
V. da Silva,
J. Daughhetee,
J. Detwiler,
K. Ding,
M. R. Durand,
Y. Efremenko,
S. R. Elliott,
A. Erlandson,
L. Fabris,
M. Febbraro,
A. Galindo-Uribarri,
M. P. Green,
J. Hakenmüller,
M. R. Heath,
S. Hedges,
B. A. Johnson
, et al. (55 additional authors not shown)
Abstract:
We consider the potential for a 10-kg undoped cryogenic CsI detector operating at the Spallation Neutron Source to measure coherent elastic neutrino-nucleus scattering and its sensitivity to discover new physics beyond the standard model. Through a combination of increased event rate, lower threshold, and good timing resolution, such a detector would significantly improve on past measurements. We…
▽ More
We consider the potential for a 10-kg undoped cryogenic CsI detector operating at the Spallation Neutron Source to measure coherent elastic neutrino-nucleus scattering and its sensitivity to discover new physics beyond the standard model. Through a combination of increased event rate, lower threshold, and good timing resolution, such a detector would significantly improve on past measurements. We considered tests of several beyond-the-standard-model scenarios such as neutrino non-standard interactions and accelerator-produced dark matter. This detector's performance was also studied for relevant questions in nuclear physics and neutrino astronomy, namely the weak charge distribution of CsI nuclei and detection of neutrinos from a core-collapse supernova.
△ Less
Submitted 21 November, 2023;
originally announced November 2023.
-
Measurement of the Electron-Neutrino Charged-Current Cross Sections on ${}^{127}$I with the COHERENT NaI$ν$E detector
Authors:
P. An,
C. Awe,
P. S. Barbeau,
B. Becker,
V. Belov,
I. Bernardi,
C. Bock,
A. Bolozdynya,
R. Bouabid,
A. Brown,
J. Browning,
B. Cabrera-Palmer,
M. Cervantes,
E. Conley,
J. Daughhetee,
J. Detwiler,
K. Ding,
M. R. Durand,
Y. Efremenko,
S. R. Elliott,
L. Fabris,
M. Febbraro,
A. Gallo Rosso,
A. Galindo-Uribarri,
A. C. Germer
, et al. (64 additional authors not shown)
Abstract:
Using an 185-kg NaI[Tl] array, COHERENT has measured the inclusive electron-neutrino charged-current cross section on ${}^{127}$I with pion decay-at-rest neutrinos produced by the Spallation Neutron Source at Oak Ridge National Laboratory. Iodine is one the heaviest targets for which low-energy ($\leq$ 50 MeV) inelastic neutrino-nucleus processes have been measured, and this is the first measureme…
▽ More
Using an 185-kg NaI[Tl] array, COHERENT has measured the inclusive electron-neutrino charged-current cross section on ${}^{127}$I with pion decay-at-rest neutrinos produced by the Spallation Neutron Source at Oak Ridge National Laboratory. Iodine is one the heaviest targets for which low-energy ($\leq$ 50 MeV) inelastic neutrino-nucleus processes have been measured, and this is the first measurement of its inclusive cross section. After a five-year detector exposure, COHERENT reports a flux-averaged cross section for electron neutrinos of $9.2^{+2.1}_{-1.8} \times 10^{-40}$ cm$^2$. This corresponds to a value that is $\sim$41% lower than predicted using the MARLEY event generator with a measured Gamow-Teller strength distribution. In addition, the observed visible spectrum from charged-current scattering on $^{127}$I has been measured between 10 and 55 MeV, and the exclusive zero-neutron and one-or-more-neutron emission cross sections are measured to be $5.2^{+3.4}_{-3.1} \times 10^{-40}$ and $2.2^{+3.5}_{-2.2} \times 10^{-40}$ cm$^2$, respectively.
△ Less
Submitted 7 March, 2024; v1 submitted 31 May, 2023;
originally announced May 2023.
-
Measurement of ${}^{nat}$Pb($ν_e$,X$n$) production with a stopped-pion neutrino source
Authors:
COHERENT Collaboration,
P. An,
C. Awe,
P. S. Barbeau,
B. Becker,
S. W. Belling,
V. Belov,
I. Bernardi,
C. Bock,
A. Bolozdynya,
R. Bouabid,
A. Brown,
J. Browning,
B. Cabrera-Palmer,
M. Cervantes,
E. Conley,
J. Daughhetee,
J. Detwiler,
K. Ding,
M. R. Durand,
Y. Efremenko,
S. R. Elliott,
L. Fabris,
M. Febbraro,
A. Gallo Rosso
, et al. (62 additional authors not shown)
Abstract:
Using neutrinos produced at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL), the COHERENT collaboration has studied the Pb($ν_e$,X$n$) process with a lead neutrino-induced-neutron (NIN) detector. Data from this detector are fit jointly with previously collected COHERENT data on this process. A combined analysis of the two datasets yields a cross section that is…
▽ More
Using neutrinos produced at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL), the COHERENT collaboration has studied the Pb($ν_e$,X$n$) process with a lead neutrino-induced-neutron (NIN) detector. Data from this detector are fit jointly with previously collected COHERENT data on this process. A combined analysis of the two datasets yields a cross section that is $0.29^{+0.17}_{-0.16}$ times that predicted by the MARLEY event generator using experimentally-measured Gamow-Teller strength distributions, consistent with no NIN events at 1.8$σ$. This is the first inelastic neutrino-nucleus process COHERENT has studied, among several planned exploiting the high flux of low-energy neutrinos produced at the SNS.
△ Less
Submitted 30 October, 2023; v1 submitted 21 December, 2022;
originally announced December 2022.
-
A COHERENT constraint on leptophobic dark matter using CsI data
Authors:
COHERENT Collaboration,
D. Akimov,
P. An,
C. Awe,
P. S. Barbeau,
B. Becker,
V. Belov,
I. Bernardi,
M. A. Blackston,
C. Bock,
A. Bolozdynya,
R. Bouabid,
J. Browning,
B. Cabrera-Palmer,
D. Chernyak,
E. Conley,
J. Daughhetee,
J. Detwiler,
K. Ding,
M. R. Durand,
Y. Efremenko,
S. R. Elliot,
L. Fabris,
M. Febbraro,
A. Gallo Rosso
, et al. (56 additional authors not shown)
Abstract:
We use data from the COHERENT CsI[Na] scintillation detector to constrain sub-GeV leptophobic dark matter models. This detector was built to observe low-energy nuclear recoils from coherent elastic neutrino-nucleus scattering. These capabilities enable searches for dark matter particles produced at the Spallation Neutron Source mediated by a vector portal particle with masses between 2 and 400 MeV…
▽ More
We use data from the COHERENT CsI[Na] scintillation detector to constrain sub-GeV leptophobic dark matter models. This detector was built to observe low-energy nuclear recoils from coherent elastic neutrino-nucleus scattering. These capabilities enable searches for dark matter particles produced at the Spallation Neutron Source mediated by a vector portal particle with masses between 2 and 400 MeV/c$^2$. No evidence for dark matter is observed and a limit on the mediator coupling to quarks is placed. This constraint improves upon previous results by two orders of magnitude. This newly explored parameter space probes the region where the dark matter relic abundance is explained by leptophobic dark matter when the mediator mass is roughly twice the dark matter mass. COHERENT sets the best constraint on leptophobic dark matter at these masses.
△ Less
Submitted 26 May, 2022; v1 submitted 24 May, 2022;
originally announced May 2022.
-
The COHERENT Experimental Program
Authors:
D. Akimov,
S. Alawabdeh,
P. An,
A. Arteaga,
C. Awe,
P. S. Barbeau,
C. Barry,
B. Becker,
V. Belov,
I. Bernardi,
M. A. Blackston,
L. Blokland,
C. Bock,
B. Bodur,
A. Bolozdynya,
R. Bouabid,
A. Bracho,
J. Browning,
B. Cabrera-Palmer,
N. Chen,
D. Chernyak,
E. Conley,
J. Daughhetee,
J. Daughtry,
E. Day
, et al. (106 additional authors not shown)
Abstract:
The COHERENT experiment located in Neutrino Alley at the Spallation Neutron Source (SNS), Oak Ridge National Laboratory (ORNL), has made the world's first two measurements of coherent elastic neutrino-nucleus scattering (CEvNS), on CsI and argon, using neutrinos produced at the SNS. The COHERENT collaboration continues to pursue CEvNS measurements on various targets as well as additional studies o…
▽ More
The COHERENT experiment located in Neutrino Alley at the Spallation Neutron Source (SNS), Oak Ridge National Laboratory (ORNL), has made the world's first two measurements of coherent elastic neutrino-nucleus scattering (CEvNS), on CsI and argon, using neutrinos produced at the SNS. The COHERENT collaboration continues to pursue CEvNS measurements on various targets as well as additional studies of inelastic neutrino-nucleus interactions, searches for accelerator-produced dark matter (DM) and physics beyond the Standard Model, using the uniquely high-quality and high-intensity neutrino source available at the SNS. This white paper describes primarily COHERENT's ongoing and near-future program at the SNS First Target Station (FTS). Opportunities enabled by the SNS Second Target Station (STS) for the study of neutrino physics and development of novel detector technologies are elaborated in a separate white paper.
△ Less
Submitted 9 April, 2022;
originally announced April 2022.
-
Monitoring the SNS basement neutron background with the MARS detector
Authors:
COHERENT Collaboration,
D. Akimov,
P. An,
C. Awe,
P. S. Barbeau,
B. Becker,
V. Belov,
I. Bernardi,
M. A. Blackston,
C. Bock,
A. Bolozdynya,
J. Browning,
B. Cabrera-Palmer,
D. Chernyak,
E. Conley,
J. Daughhetee,
J. Detwiler,
K. Ding,
M. R. Durand,
Y. Efremenko,
S. R. Elliott,
L. Fabris,
M. Febbraro,
A. Gallo Rosso,
A. Galindo-Uribarri
, et al. (53 additional authors not shown)
Abstract:
We present the analysis and results of the first dataset collected with the MARS neutron detector deployed at the Oak Ridge National Laboratory Spallation Neutron Source (SNS) for the purpose of monitoring and characterizing the beam-related neutron (BRN) background for the COHERENT collaboration. MARS was positioned next to the COH-CsI coherent elastic neutrino-nucleus scattering detector in the…
▽ More
We present the analysis and results of the first dataset collected with the MARS neutron detector deployed at the Oak Ridge National Laboratory Spallation Neutron Source (SNS) for the purpose of monitoring and characterizing the beam-related neutron (BRN) background for the COHERENT collaboration. MARS was positioned next to the COH-CsI coherent elastic neutrino-nucleus scattering detector in the SNS basement corridor. This is the basement location of closest proximity to the SNS target and thus, of highest neutrino flux, but it is also well shielded from the BRN flux by infill concrete and gravel. These data show the detector registered roughly one BRN per day. Using MARS' measured detection efficiency, the incoming BRN flux is estimated to be $1.20~\pm~0.56~\text{neutrons}/\text{m}^2/\text{MWh}$ for neutron energies above $\sim3.5$ MeV and up to a few tens of MeV. We compare our results with previous BRN measurements in the SNS basement corridor reported by other neutron detectors.
△ Less
Submitted 14 April, 2022; v1 submitted 5 December, 2021;
originally announced December 2021.
-
First Probe of Sub-GeV Dark Matter Beyond the Cosmological Expectation with the COHERENT CsI Detector at the SNS
Authors:
D. Akimov,
P. An,
C. Awe,
P. S. Barbeau,
B. Becker,
V. Belov,
I. Bernardi,
M. A. Blackston,
C. Bock,
A. Bolozdynya,
J. Browning,
B. Cabrera-Palmer,
D. Chernyak,
E. Conley,
J. Daughhetee,
J. Detwiler,
K. Ding,
M. R. Durand,
Y. Efremenko,
S. R. Elliott,
L. Fabris,
M. Febbraro,
A. Gallo Rosso,
A. Galindo-Uribarri,
M. P. Green
, et al. (51 additional authors not shown)
Abstract:
The COHERENT collaboration searched for scalar dark matter particles produced at the Spallation Neutron Source with masses between 1 and 220~MeV/c$^2$ using a CsI[Na] scintillation detector sensitive to nuclear recoils above 9~keV$_\text{nr}$. No evidence for dark matter is found and we thus place limits on allowed parameter space. With this low-threshold detector, we are sensitive to coherent ela…
▽ More
The COHERENT collaboration searched for scalar dark matter particles produced at the Spallation Neutron Source with masses between 1 and 220~MeV/c$^2$ using a CsI[Na] scintillation detector sensitive to nuclear recoils above 9~keV$_\text{nr}$. No evidence for dark matter is found and we thus place limits on allowed parameter space. With this low-threshold detector, we are sensitive to coherent elastic scattering between dark matter and nuclei. The cross section for this process is orders of magnitude higher than for other processes historically used for accelerator-based direct-detection searches so that our small, 14.6~kg detector significantly improves on past constraints. At peak sensitivity, we reject the flux consistent with the cosmologically observed dark-matter concentration for all coupling constants $α_D<0.64$, assuming a scalar dark-matter particle. We also calculate the sensitivity of future COHERENT detectors to dark-matter signals which will ambitiously test multiple dark-matter spin scenarios.
△ Less
Submitted 14 February, 2023; v1 submitted 21 October, 2021;
originally announced October 2021.
-
Measurement of the Coherent Elastic Neutrino-Nucleus Scattering Cross Section on CsI by COHERENT
Authors:
D. Akimov,
P. An,
C. Awe,
P. S. Barbeau,
B. Becker,
V. Belov,
I. Bernardi,
M. A. Blackston,
C. Bock,
A. Bolozdynya,
J. Browning,
B. Cabrera-Palmer,
D. Chernyak,
E. Conley,
J. Daughhetee,
J. Detwiler,
K. Ding,
M. R. Durand,
Y. Efremenko,
S. R. Elliott,
L. Fabris,
M. Febbraro,
A. Gallo Rosso,
A. Galindo-Uribarri,
M. P. Green
, et al. (51 additional authors not shown)
Abstract:
We measured the cross section of coherent elastic neutrino-nucleus scattering (\cevns{}) using a CsI[Na] scintillating crystal in a high flux of neutrinos produced at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory. New data collected before detector decommissioning has more than doubled the dataset since the first observation of \cevns{}, achieved with this detector. Systemat…
▽ More
We measured the cross section of coherent elastic neutrino-nucleus scattering (\cevns{}) using a CsI[Na] scintillating crystal in a high flux of neutrinos produced at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory. New data collected before detector decommissioning has more than doubled the dataset since the first observation of \cevns{}, achieved with this detector. Systematic uncertainties have also been reduced with an updated quenching model, allowing for improved precision. With these analysis improvements, the COHERENT collaboration determined the cross section to be $(165^{+30}_{-25})\times10^{-40}$~cm$^2$, consistent with the standard model, giving the most precise measurement of \cevns{} yet. The timing structure of the neutrino beam has been exploited to compare the \cevns{} cross section from scattering of different neutrino flavors. This result places leading constraints on neutrino non-standard interactions while testing lepton flavor universality and measures the weak mixing angle as $\sin^2θ_{W}=0.220^{+0.028}_{-0.026}$ at $Q^2\approx(50\text{ MeV})^2$
△ Less
Submitted 2 June, 2022; v1 submitted 14 October, 2021;
originally announced October 2021.
-
Simulating the neutrino flux from the Spallation Neutron Source for the COHERENT experiment
Authors:
COHERENT Collaboration,
D. Akimov,
P. An,
C. Awe,
P. S. Barbeau,
B. Becker,
V. Belov,
I. Bernardi,
M. A. Blackston,
C. Bock,
A. Bolozdynya,
J. Browning,
B. Cabrera-Palmer,
D. Chernyak,
E. Conley,
J. Daughhetee,
J. Detwiler,
K. Ding,
M. R. Durand,
Y. Efremenko,
S. R. Elliott,
L. Fabris,
M. Febbraro,
J. Galambos,
A. Gallo Rosso
, et al. (58 additional authors not shown)
Abstract:
The Spallation Neutron Source (SNS) at Oak Ridge National Laboratory is a pulsed source of neutrons and, as a byproduct of this operation, an intense source of pulsed neutrinos via stopped-pion decay. The COHERENT collaboration uses this source to investigate coherent elastic neutrino-nucleus scattering and other physics with a suite of detectors. This work includes a description of our Geant4 sim…
▽ More
The Spallation Neutron Source (SNS) at Oak Ridge National Laboratory is a pulsed source of neutrons and, as a byproduct of this operation, an intense source of pulsed neutrinos via stopped-pion decay. The COHERENT collaboration uses this source to investigate coherent elastic neutrino-nucleus scattering and other physics with a suite of detectors. This work includes a description of our Geant4 simulation of neutrino production at the SNS and the flux calculation which informs the COHERENT studies. We estimate the uncertainty of this calculation at about 10% based on validation against available low-energy pion production data.
△ Less
Submitted 29 March, 2022; v1 submitted 22 September, 2021;
originally announced September 2021.
-
A D$_{2}$O detector for flux normalization of a pion decay-at-rest neutrino source
Authors:
COHERENT Collaboration,
D. Akimov,
P. An,
C. Awe,
P. S. Barbeau,
B. Becker,
V. Belov,
I. Bernardi,
M. A. Blackston,
L. Blokland,
A. Bolozdynya,
B. Cabrera-Palmer,
D. Chernyak,
E. Conley,
J. Daughhetee,
E. Day,
J. Detwiler,
K. Ding,
M. R. Durand,
Y. Efremenko,
S. R. Elliott,
L. Fabris,
M. Febbraro,
A. Gallo Rosso,
A. Galindo-Uribarri
, et al. (54 additional authors not shown)
Abstract:
We report on the technical design and expected performance of a 592 kg heavy-water-Cherenkov detector to measure the absolute neutrino flux from the pion-decay-at-rest neutrino source at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL). The detector will be located roughly 20 m from the SNS target and will measure the neutrino flux with better than 5% statistical uncerta…
▽ More
We report on the technical design and expected performance of a 592 kg heavy-water-Cherenkov detector to measure the absolute neutrino flux from the pion-decay-at-rest neutrino source at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL). The detector will be located roughly 20 m from the SNS target and will measure the neutrino flux with better than 5% statistical uncertainty in 2 years. This heavy-water detector will serve as the first module of a two-module detector system to ultimately measure the neutrino flux to 2-3% at both the First Target Station and the planned Second Target Station of the SNS. This detector will significantly reduce a dominant systematic uncertainty for neutrino cross-section measurements at the SNS, increasing the sensitivity of searches for new physics.
△ Less
Submitted 25 August, 2021; v1 submitted 19 April, 2021;
originally announced April 2021.
-
Cosmic antihelium-3 nuclei sensitivity of the GAPS experiment
Authors:
N. Saffold,
T. Aramaki,
R. Bird,
M. Boezio,
S. E. Boggs,
V. Bonvicini,
D. Campana,
W. W. Craig,
P. von Doetinchem,
E. Everson,
L. Fabris,
H. Fuke,
F. Gahbauer,
I. Garcia,
C. Gerrity,
C. J. Hailey,
T. Hayashi,
C. Kato,
A. Kawachi,
S. Kobayashi,
M. Kozai,
A. Lenni,
A. Lowell,
M. Manghisoni,
N. Marcelli
, et al. (30 additional authors not shown)
Abstract:
The General Antiparticle Spectrometer (GAPS) is an Antarctic balloon experiment designed for low-energy (0.1$-$0.3 GeV/$n$) cosmic antinuclei as signatures of dark matter annihilation or decay. GAPS is optimized to detect low-energy antideuterons, as well as to provide unprecedented sensitivity to low-energy antiprotons and antihelium nuclei. The novel GAPS antiparticle detection technique, based…
▽ More
The General Antiparticle Spectrometer (GAPS) is an Antarctic balloon experiment designed for low-energy (0.1$-$0.3 GeV/$n$) cosmic antinuclei as signatures of dark matter annihilation or decay. GAPS is optimized to detect low-energy antideuterons, as well as to provide unprecedented sensitivity to low-energy antiprotons and antihelium nuclei. The novel GAPS antiparticle detection technique, based on the formation, decay, and annihilation of exotic atoms, provides greater identification power for these low-energy antinuclei than previous magnetic spectrometer experiments. This work reports the sensitivity of GAPS to detect antihelium-3 nuclei, based on full instrument simulation, event reconstruction, and realistic atmospheric influence simulations. The report of antihelium nuclei candidate events by AMS-02 has generated considerable interest in antihelium nuclei as probes of dark matter and other beyond the Standard Model theories. GAPS is in a unique position to detect or set upper limits on the cosmic antihelium nuclei flux in an energy range that is essentially free of astrophysical background. In three 35-day long-duration balloon flights, GAPS will be sensitive to an antihelium flux on the level of $1.3^{+4.5}_{-1.2}\cdot 10^{-6}\mathrm{m^{-2}sr^{-1}s^{-1}}(\mathrm{GeV}/n)^{-1}$ (95% confidence level) in the energy range of 0.11$-$0.3 GeV/$n$, opening a new window on rare cosmic physics.
△ Less
Submitted 14 April, 2021; v1 submitted 10 December, 2020;
originally announced December 2020.
-
Development of a $^{83\mathrm{m}}$Kr source for the calibration of the CENNS-10 Liquid Argon Detector
Authors:
COHERENT Collaboration,
D. Akimov,
P. An,
C. Awe,
P. S. Barbeau,
B. Becker,
V. Belov,
I. Bernardi,
M. A. Blackston,
L. Blokland,
A. Bolozdynya,
B. Cabrera-Palmer,
N. Chen,
D. Chernyak,
E. Conley,
J. Daughhetee,
M. del Valle Coello,
J. A. Detwiler,
M. R. Durand,
Y. Efremenko,
S. R. Elliott,
L. Fabris,
M. Febbraro,
W. Fox,
A. Galindo-Uribarri
, et al. (55 additional authors not shown)
Abstract:
We report on the preparation of and calibration measurements with a $^{83\mathrm{m}}$Kr source for the CENNS-10 liquid argon detector. $^{83\mathrm{m}}$Kr atoms generated in the decay of a $^{83}$Rb source were introduced into the detector via injection into the Ar circulation loop. Scintillation light arising from the 9.4 keV and 32.1 keV conversion electrons in the decay of $^{83\mathrm{m}}$Kr i…
▽ More
We report on the preparation of and calibration measurements with a $^{83\mathrm{m}}$Kr source for the CENNS-10 liquid argon detector. $^{83\mathrm{m}}$Kr atoms generated in the decay of a $^{83}$Rb source were introduced into the detector via injection into the Ar circulation loop. Scintillation light arising from the 9.4 keV and 32.1 keV conversion electrons in the decay of $^{83\mathrm{m}}$Kr in the detector volume were then observed. This calibration source allows the characterization of the low-energy response of the CENNS-10 detector and is applicable to other low-energy-threshold detectors. The energy resolution of the detector was measured to be 9$\%$ at the total $^{83\mathrm{m}}$Kr decay energy of 41.5 keV. We performed an analysis to separately calibrate the detector using the two conversion electrons at 9.4 keV and 32.1 keV
△ Less
Submitted 27 January, 2021; v1 submitted 21 October, 2020;
originally announced October 2020.
-
COHERENT Collaboration data release from the first detection of coherent elastic neutrino-nucleus scattering on argon
Authors:
COHERENT Collaboration,
D. Akimov,
J. B. Albert,
P. An,
C. Awe,
P. S. Barbeau,
B. Becker,
V. Belov,
M. A. Blackston,
L. Blokland,
A. Bolozdynya,
B. Cabrera-Palmer,
N. Chen,
D. Chernyak,
E. Conley,
R. L. Cooper,
J. Daughhetee,
M. del Valle Coello,
J. A. Detwiler,
M. R. Durand,
Y. Efremenko,
S. R. Elliott,
L. Fabris,
M. Febbraro,
W. Fox
, et al. (58 additional authors not shown)
Abstract:
Release of COHERENT collaboration data from the first detection of coherent elastic neutrino-nucleus scattering (CEvNS) on argon. This release corresponds with the results of "Analysis A" published in Akimov et al., arXiv:2003.10630 [nucl-ex]. Data is shared in a binned, text-based format representing both "signal" and "backgrounds" along with associated uncertainties such that the included data c…
▽ More
Release of COHERENT collaboration data from the first detection of coherent elastic neutrino-nucleus scattering (CEvNS) on argon. This release corresponds with the results of "Analysis A" published in Akimov et al., arXiv:2003.10630 [nucl-ex]. Data is shared in a binned, text-based format representing both "signal" and "backgrounds" along with associated uncertainties such that the included data can be used to perform independent analyses. This document describes the contents of the data release as well as guidance on the use of the data. Included example code in C++ (ROOT) and Python show one possible use of the included data.
△ Less
Submitted 29 July, 2020; v1 submitted 22 June, 2020;
originally announced June 2020.
-
First Measurement of Coherent Elastic Neutrino-Nucleus Scattering on Argon
Authors:
COHERENT Collaboration,
D. Akimov,
J. B. Albert,
P. An,
C. Awe,
P. S. Barbeau,
B. Becker,
V. Belov,
M. A. Blackston,
L. Blokland,
A. Bolozdynya,
B. Cabrera-Palmer,
N. Chen,
D. Chernyak,
E. Conley,
R. L. Cooper,
J. Daughhetee,
M. del Valle Coello,
J. A. Detwiler,
M. R. Durand,
Y. Efremenko,
S. R. Elliott,
L. Fabris,
M. Febbraro,
W. Fox
, et al. (58 additional authors not shown)
Abstract:
We report the first measurement of coherent elastic neutrino-nucleus scattering (\cevns) on argon using a liquid argon detector at the Oak Ridge National Laboratory Spallation Neutron Source. Two independent analyses prefer \cevns over the background-only null hypothesis with greater than $3σ$ significance. The measured cross section, averaged over the incident neutrino flux, is (2.2 $\pm$ 0.7)…
▽ More
We report the first measurement of coherent elastic neutrino-nucleus scattering (\cevns) on argon using a liquid argon detector at the Oak Ridge National Laboratory Spallation Neutron Source. Two independent analyses prefer \cevns over the background-only null hypothesis with greater than $3σ$ significance. The measured cross section, averaged over the incident neutrino flux, is (2.2 $\pm$ 0.7) $\times$10$^{-39}$ cm$^2$ -- consistent with the standard model prediction. The neutron-number dependence of this result, together with that from our previous measurement on CsI, confirms the existence of the \cevns process and provides improved constraints on non-standard neutrino interactions.
△ Less
Submitted 15 February, 2021; v1 submitted 23 March, 2020;
originally announced March 2020.
-
Reflectance of Silicon Photomultipliers at Vacuum Ultraviolet Wavelengths
Authors:
P. Lv,
G. F. Cao,
L. J. Wen,
S. Al Kharusi,
G. Anton,
I. J. Arnquist,
I. Badhrees,
P. S. Barbeau,
D. Beck,
V. Belov,
T. Bhatta,
P. A. Breur,
J. P. Brodsky,
E. Brown,
T. Brunner,
S. Byrne Mamahit,
E. Caden,
L. Cao,
C. Chambers,
B. Chana,
S. A. Charlebois,
M. Chiu,
B. Cleveland,
M. Coon,
A. Craycraft
, et al. (126 additional authors not shown)
Abstract:
Characterization of the vacuum ultraviolet (VUV) reflectance of silicon photomultipliers (SiPMs) is important for large-scale SiPM-based photodetector systems. We report the angular dependence of the specular reflectance in a vacuum of SiPMs manufactured by Fondazionc Bruno Kessler (FBK) and Hamamatsu Photonics K.K. (HPK) over wavelengths ranging from 120 nm to 280 nm. Refractive index and extinct…
▽ More
Characterization of the vacuum ultraviolet (VUV) reflectance of silicon photomultipliers (SiPMs) is important for large-scale SiPM-based photodetector systems. We report the angular dependence of the specular reflectance in a vacuum of SiPMs manufactured by Fondazionc Bruno Kessler (FBK) and Hamamatsu Photonics K.K. (HPK) over wavelengths ranging from 120 nm to 280 nm. Refractive index and extinction coefficient of the thin silicon-dioxide film deposited on the surface of the FBK SiPMs are derived from reflectance data of a FBK silicon wafer with the same deposited oxide film as SiPMs. The diffuse reflectance of SiPMs is also measured at 193 nm. We use the VUV spectral dependence of the optical constants to predict the reflectance of the FBK silicon wafer and FBK SiPMs in liquid xenon.
△ Less
Submitted 4 December, 2019;
originally announced December 2019.
-
Sensitivity of the COHERENT Experiment to Accelerator-Produced Dark Matter
Authors:
COHERENT Collaboration,
D. Akimov,
P. An,
C. Awe,
P. S. Barbeau,
B. Becker,
V. Belov,
M. A. Blackston,
A. Bolozdynya,
B. Cabrera-Palmer,
N. Chen,
E. Conley,
R. L. Cooper,
J. Daughhetee,
M. del Valle Coello,
J. A. Detwiler,
M. R. Durand,
Y. Efremenko,
S. R. Elliott,
L. Fabris,
M. Febbraro,
W. Fox,
A. Galindo-Uribarri,
M. P. Green,
K. S. Hansen
, et al. (53 additional authors not shown)
Abstract:
The COHERENT experiment is well poised to test sub-GeV dark matter models using low-energy recoil detectors sensitive to coherent elastic neutrino-nucleus scattering (CEvNS) in the $π$-DAR neutrino beam produced by the Spallation Neutron Source. We show how a planned 750-kg liquid argon scintillation detector would place leading limits on scalar light dark matter models, over two orders of magnitu…
▽ More
The COHERENT experiment is well poised to test sub-GeV dark matter models using low-energy recoil detectors sensitive to coherent elastic neutrino-nucleus scattering (CEvNS) in the $π$-DAR neutrino beam produced by the Spallation Neutron Source. We show how a planned 750-kg liquid argon scintillation detector would place leading limits on scalar light dark matter models, over two orders of magnitude of dark matter mass, for dark matter particles produced through vector and leptophobic portals in the absence of other effects beyond the standard model. The characteristic timing structure of a $π$-DAR beam allows a unique opportunity for constraining systematic uncertainties on the standard model background in a time window where signal is not expected, enhancing expected sensitivity. Additionally, we discuss future prospects, further increasing the discovery potential of CEvNS detectors. Such methods would test the calculated thermal dark matter abundance for all couplings $α'\leq1$ within the vector portal model over an order of magnitude of dark matter masses.
△ Less
Submitted 14 November, 2019;
originally announced November 2019.
-
Reflectivity and PDE of VUV4 Hamamatsu SiPMs in Liquid Xenon
Authors:
P. Nakarmi,
I. Ostrovskiy,
A. K. Soma,
F. Retiere,
S. Al Kharusi,
M. Alfaris,
G. Anton,
I. J. Arnquist,
I. Badhrees,
P. S. Barbeau,
D. Beck,
V. Belov,
T. Bhatta,
J. Blatchford,
P. A. Breur,
J. P. Brodsky,
E. Brown,
T. Brunner,
S. Byrne Mamahit,
E. Caden,
G. F. Cao,
L. Cao,
C. Chambers,
B. Chana,
S. A. Charlebois
, et al. (130 additional authors not shown)
Abstract:
Understanding reflective properties of materials and photodetection efficiency (PDE) of photodetectors is important for optimizing energy resolution and sensitivity of the next generation neutrinoless double beta decay, direct detection dark matter, and neutrino oscillation experiments that will use noble liquid gases, such as nEXO, DARWIN, DarkSide-20k, and DUNE. Little information is currently a…
▽ More
Understanding reflective properties of materials and photodetection efficiency (PDE) of photodetectors is important for optimizing energy resolution and sensitivity of the next generation neutrinoless double beta decay, direct detection dark matter, and neutrino oscillation experiments that will use noble liquid gases, such as nEXO, DARWIN, DarkSide-20k, and DUNE. Little information is currently available about reflectivity and PDE in liquid noble gases, because such measurements are difficult to conduct in a cryogenic environment and at short enough wavelengths. Here we report a measurement of specular reflectivity and relative PDE of Hamamatsu VUV4 silicon photomultipliers (SiPMs) with 50 micrometer micro-cells conducted with xenon scintillation light (~175 nm) in liquid xenon. The specular reflectivity at 15 deg. incidence of three samples of VUV4 SiPMs is found to be 30.4+/-1.4%, 28.6+/-1.3%, and 28.0+/-1.3%, respectively. The PDE at normal incidence differs by +/-8% (standard deviation) among the three devices. The angular dependence of the reflectivity and PDE was also measured for one of the SiPMs. Both the reflectivity and PDE decrease as the angle of incidence increases. This is the first measurement of an angular dependence of PDE and reflectivity of a SiPM in liquid xenon.
△ Less
Submitted 24 December, 2019; v1 submitted 14 October, 2019;
originally announced October 2019.
-
First Constraint on Coherent Elastic Neutrino-Nucleus Scattering in Argon
Authors:
COHERENT Collaboration,
D. Akimov,
J. B. Albert,
P. An,
C. Awe,
P. S. Barbeau,
B. Becker,
V. Belov,
M. A. Blackston,
A. Bolozdynya,
B. Cabrera-Palmer,
M. Cervantes,
J. I. Collar,
R. L. Cooper,
J. Daughhetee,
M. del Valle Coello,
J. A. Detwiler,
M. D'Onofrio,
Y. Efremenko,
E. M. Erkela,
S. R. Elliott,
L. Fabris,
M. Febbraro,
W. Fox,
A. Galindo-Uribarri
, et al. (55 additional authors not shown)
Abstract:
Coherent elastic neutrino-nucleus scattering (CEvNS) is the dominant neutrino scattering channel for neutrinos of energy $E_ν< 100$ MeV. We report a limit for this process using data collected in an engineering run of the 29 kg CENNS-10 liquid argon detector located 27.5 m from the Oak Ridge National Laboratory Spallation Neutron Source (SNS) Hg target with $4.2\times 10^{22}$ protons on target. T…
▽ More
Coherent elastic neutrino-nucleus scattering (CEvNS) is the dominant neutrino scattering channel for neutrinos of energy $E_ν< 100$ MeV. We report a limit for this process using data collected in an engineering run of the 29 kg CENNS-10 liquid argon detector located 27.5 m from the Oak Ridge National Laboratory Spallation Neutron Source (SNS) Hg target with $4.2\times 10^{22}$ protons on target. The dataset yielded $< 7.4$ observed CEvNS events implying a cross section for the process, averaged over the SNS pion decay-at-rest flux, of $<3.4 \times 10^{-39}$ cm$^{2}$, a limit within twice the Standard Model prediction. This is the first limit on CEvNS from an argon nucleus and confirms the earlier CsI non-standard neutrino interaction constraints from the collaboration. This run demonstrated the feasibility of the ongoing experimental effort to detect CEvNS with liquid argon.
△ Less
Submitted 12 September, 2019;
originally announced September 2019.
-
An Indirect Dark Matter Search Using Cosmic-Ray Antiparticles with GAPS
Authors:
Alexander Lowell,
Tsuguo Aramaki,
Ralph Bird,
Mirko Boezio,
Steven Boggs,
Rachel Carr,
William Craig,
Philip von Doetinchem,
Lorenzo Fabris,
Hideyuki Fuke,
Florian Gahbauer,
Cory Gerrity,
Charles Hailey,
Chihiro Kato,
Akiko Kawachi,
Masayoshi Kozai,
Isaac Mognet,
Kazuoki Munakata,
Shun Okazaki,
Rene Ong,
Guiseppe Osteria,
Kerstin Perez,
Sean Quinn,
Valerio Re,
Field Rogers
, et al. (8 additional authors not shown)
Abstract:
Experiments aiming to directly detect dark matter (DM) particles have yet to make robust detections, thus underscoring the need for complementary approaches such as searches for new particles at colliders, and indirect DM searches in cosmic-ray spectra. Low energy (< 0.25 GeV/n) cosmic-ray antiparticles such as antideuterons are strong candidates for probing DM models, as the yield of these partic…
▽ More
Experiments aiming to directly detect dark matter (DM) particles have yet to make robust detections, thus underscoring the need for complementary approaches such as searches for new particles at colliders, and indirect DM searches in cosmic-ray spectra. Low energy (< 0.25 GeV/n) cosmic-ray antiparticles such as antideuterons are strong candidates for probing DM models, as the yield of these particles from DM processes can exceed the astrophysical background by more than two orders of magnitude. The General Antiparticle Spectrometer (GAPS), a balloon borne cosmic-ray detector, will perform an ultra-low background measurement of the cosmic antideuteron flux in the regime < 0.25 GeV/n, which will constrain a wide range of DM models. GAPS will also detect approximately 1000 antiprotons in an unexplored energy range throughout one long duration balloon (LDB) flight, which will constrain < 10 GeV DM models and validate the GAPS detection technique. Unlike magnetic spectrometers, GAPS relies on the formation of an exotic atom within the tracker in order to identify antiparticles. The GAPS tracker consists of ten layers of lithium-drifted silicon detectors which record dE/dx deposits from primary and nuclear annihilation product tracks, as well as measure the energy of the exotic atom deexcitation X-rays. A two-layer, plastic scintillator time of flight (TOF) system surrounds the tracker and measures the particle velocity, dE/dx deposits, and provides a fast trigger to the tracker. The nuclear annihilation product multiplicity, deexcitation X-ray energies, TOF, and stop** depth are all used together to discern between antiparticle species. This presentation provided an overview of the GAPS experiment, an update on the construction of the tracker and TOF systems, and a summary of the expected performance of GAPS in light of the upcoming LDB flight from McMurdo Station, Antarctica in 2020.
△ Less
Submitted 11 December, 2018;
originally announced December 2018.
-
COHERENT Collaboration data release from the first observation of coherent elastic neutrino-nucleus scattering
Authors:
COHERENT Collaboration,
D. Akimov,
J. B. Albert,
P. An,
C. Awe,
P. S. Barbeau,
B. Becker,
V. Belov,
M. A. Blackston,
A. Bolozdynya,
A. Brown,
A. Burenkov,
B. Cabrera-Palmer,
M. Cervantes,
J. I. Collar,
R. J. Cooper,
R. L. Cooper,
C. Cuesta,
J. Daughhetee,
D. J. Dean,
M. del Valle Coello,
J. Detwiler,
M. D'Onofrio,
A. Eberhardt,
Y. Efremenko
, et al. (69 additional authors not shown)
Abstract:
This release includes data and information necessary to perform independent analyses of the COHERENT result presented in Akimov et al., arXiv:1708.01294 [nucl-ex]. Data is shared in a binned, text-based format, including both "signal" and "background" regions, so that counts and associated uncertainties can be quantitatively calculated for the purpose of separate analyses. This document describes…
▽ More
This release includes data and information necessary to perform independent analyses of the COHERENT result presented in Akimov et al., arXiv:1708.01294 [nucl-ex]. Data is shared in a binned, text-based format, including both "signal" and "background" regions, so that counts and associated uncertainties can be quantitatively calculated for the purpose of separate analyses. This document describes the included information and its format, offering some guidance on use of the data. Accompanying code examples show basic interaction with the data using Python.
△ Less
Submitted 25 April, 2018;
originally announced April 2018.
-
COHERENT 2018 at the Spallation Neutron Source
Authors:
D. Akimov,
J. B. Albert,
P. An,
C. Awe,
P. S. Barbeau,
B. Becker,
V. Belov,
M. A. Blackston,
A. Bolozdynya,
A. Brown,
A. Burenkov,
B. Cabrera-Palmer,
M. Cervantes,
J. I. Collar,
R. J. Cooper,
R. L. Cooper,
J. Daughhetee,
D. J. Dean,
M. del Valle Coello,
J. A. Detwiler,
M. D'Onofrio,
Y. Efremenko,
S. R. Elliott,
E. Erkela,
A. Etenko
, et al. (54 additional authors not shown)
Abstract:
The primary goal of the COHERENT collaboration is to measure and study coherent elastic neutrino-nucleus scattering (CEvNS) using the high-power, few-tens-of-MeV, pulsed source of neutrinos provided by the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL). The COHERENT collaboration reported the first detection of CEvNS [Akimov:2017ade] using a CsI[Na] detector. At present th…
▽ More
The primary goal of the COHERENT collaboration is to measure and study coherent elastic neutrino-nucleus scattering (CEvNS) using the high-power, few-tens-of-MeV, pulsed source of neutrinos provided by the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL). The COHERENT collaboration reported the first detection of CEvNS [Akimov:2017ade] using a CsI[Na] detector. At present the collaboration is deploying four detector technologies: a CsI[Na] scintillating crystal, p-type point-contact germanium detectors, single-phase liquid argon, and NaI[Tl] crystals. All detectors are located in the neutron-quiet basement of the SNS target building at distances 20-30 m from the SNS neutrino source. The simultaneous measurement in all four COHERENT detector subsystems will test the $N^2$ dependence of the cross section and search for new physics. In addition, COHERENT is measuring neutrino-induced neutrons from charged- and neutral-current neutrino interactions on nuclei in shielding materials, which represent a non-negligible background for CEvNS as well as being of intrinsic interest. The Collaboration is planning as well to look for charged-current interactions of relevance to supernova and weak-interaction physics. This document describes concisely the COHERENT physics motivations, sensitivity, and next plans for measurements at the SNS to be accomplished on a few-year timescale.
△ Less
Submitted 2 April, 2018; v1 submitted 24 March, 2018;
originally announced March 2018.
-
The GAPS Experiment to Search for Dark Matter using Low-energy Antimatter
Authors:
R. A. Ong,
T. Aramaki,
R. Bird,
M. Boezio,
S. E. Boggs,
R. Carr,
W. W. Craig,
P. von Doetinchem,
L. Fabris,
F. Gahbauer,
C. Gerrity,
H. Fuke,
C. J. Hailey,
C. Kato,
A. Kawachi,
M. Kozai,
S. I. Mognet,
K. Munakata,
S. Okazaki,
G. Osteria,
K. Perez,
V. Re,
F. Rogers,
N. Saffold,
Y. Shimizu
, et al. (4 additional authors not shown)
Abstract:
The GAPS experiment is designed to carry out a sensitive dark matter search by measuring low-energy cosmic ray antideuterons and antiprotons. GAPS will provide a new avenue to access a wide range of dark matter models and masses that is complementary to direct detection techniques, collider experiments and other indirect detection techniques. Well-motivated theories beyond the Standard Model conta…
▽ More
The GAPS experiment is designed to carry out a sensitive dark matter search by measuring low-energy cosmic ray antideuterons and antiprotons. GAPS will provide a new avenue to access a wide range of dark matter models and masses that is complementary to direct detection techniques, collider experiments and other indirect detection techniques. Well-motivated theories beyond the Standard Model contain viable dark matter candidates which could lead to a detectable signal of antideuterons resulting from the annihilation or decay of dark matter particles. The dark matter contribution to the antideuteron flux is believed to be especially large at low energies (E < 1 GeV), where the predicted flux from conventional astrophysical sources (i.e. from secondary interactions of cosmic rays) is very low. The GAPS low-energy antiproton search will provide stringent constraints on less than 10 GeV dark matter, will provide the best limits on primordial black hole evaporation on Galactic length scales, and will explore new discovery space in cosmic ray physics.
Unlike other antimatter search experiments such as BESS and AMS that use magnetic spectrometers, GAPS detects antideuterons and antiprotons using an exotic atom technique. This technique, and its unique event topology, will give GAPS a nearly background-free detection capability that is critical in a rare-event search. GAPS is designed to carry out its science program using long-duration balloon flights in Antarctica. A prototype instrument was successfully flown from Taiki, Japan in 2012. GAPS has now been approved by NASA to proceed towards the full science instrument, with the possibility of a first long-duration balloon flight in late 2020. Here we motivate low-energy cosmic ray antimatter searches and discuss the current status of the GAPS experiment and the design of the payload.
△ Less
Submitted 1 October, 2017;
originally announced October 2017.
-
Observation of Coherent Elastic Neutrino-Nucleus Scattering
Authors:
D. Akimov,
J. B. Albert,
P. An,
C. Awe,
P. S. Barbeau,
B. Becker,
V. Belov,
A. Brown,
A. Bolozdynya,
B. Cabrera-Palmer,
M. Cervantes,
J. I. Collar,
R. J. Cooper,
R. L. Cooper,
C. Cuesta,
D. J. Dean,
J. A. Detwiler,
A. Eberhardt,
Y. Efremenko,
S. R. Elliott,
E. M. Erkela,
L. Fabris,
M. Febbraro,
N. E. Fields,
W. Fox
, et al. (56 additional authors not shown)
Abstract:
The coherent elastic scattering of neutrinos off nuclei has eluded detection for four decades, even though its predicted cross-section is the largest by far of all low-energy neutrino couplings. This mode of interaction provides new opportunities to study neutrino properties, and leads to a miniaturization of detector size, with potential technological applications. We observe this process at a 6.…
▽ More
The coherent elastic scattering of neutrinos off nuclei has eluded detection for four decades, even though its predicted cross-section is the largest by far of all low-energy neutrino couplings. This mode of interaction provides new opportunities to study neutrino properties, and leads to a miniaturization of detector size, with potential technological applications. We observe this process at a 6.7-sigma confidence level, using a low-background, 14.6-kg CsI[Na] scintillator exposed to the neutrino emissions from the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory. Characteristic signatures in energy and time, predicted by the Standard Model for this process, are observed in high signal-to-background conditions. Improved constraints on non-standard neutrino interactions with quarks are derived from this initial dataset.
△ Less
Submitted 3 August, 2017;
originally announced August 2017.
-
Spectroscopy of Ba and Ba$^+$ deposits in solid xenon for barium tagging in nEXO
Authors:
B. Mong,
S. Cook,
T. Walton,
C. Chambers,
A. Craycraft,
C. Benitez-Medina,
K. Hall,
W. Fairbank Jr.,
J. B. Albert,
D. J. Auty,
P. S. Barbeau,
V. Basque,
D. Beck,
M. Breidenbach,
T. Brunner,
G. F. Cao,
B. Cleveland,
M. Coon,
T. Daniels,
S. J. Daugherty,
R. DeVoe,
T. Didberidze,
J. Dilling,
M. J. Dolinski,
M. Dunford
, et al. (51 additional authors not shown)
Abstract:
Progress on a method of barium tagging for the nEXO double beta decay experiment is reported. Absorption and emission spectra for deposits of barium atoms and ions in solid xenon matrices are presented. Excitation spectra for prominent emission lines, temperature dependence and bleaching of the fluorescence reveal the existence of different matrix sites. A regular series of sharp lines observed in…
▽ More
Progress on a method of barium tagging for the nEXO double beta decay experiment is reported. Absorption and emission spectra for deposits of barium atoms and ions in solid xenon matrices are presented. Excitation spectra for prominent emission lines, temperature dependence and bleaching of the fluorescence reveal the existence of different matrix sites. A regular series of sharp lines observed in Ba$^+$ deposits is identified with some type of barium hydride molecule. Lower limits for the fluorescence quantum efficiency of the principal Ba emission transition are reported. Under current conditions, an image of $\le10^4$ Ba atoms can be obtained. Prospects for imaging single Ba atoms in solid xenon are discussed.
△ Less
Submitted 9 October, 2014;
originally announced October 2014.