-
High average power ultrafast laser technologies for driving future advanced accelerators
Authors:
Leily Kiani,
Tong Zhou,
Seung-Whan Bahk,
Jake Bromage,
David Bruhwiler,
E. Michael Campbell,
Zenghu Chang,
Enam Chowdhury,
Michael Downer,
Qiang Du,
Eric Esarey,
Almantas Galvanauskas,
Thomas Galvin,
Constantin Hafner,
Dieter Hoffmann,
Chan Joshi,
Manoj Kanskar,
Wei Lu,
Carmen Menoni,
Michael Messerly,
Sergey B. Mirov,
Mark Palmer,
Igor Pogorelsky,
Mikhail Polyanskiy,
Erik Power
, et al. (12 additional authors not shown)
Abstract:
Large scale laser facilities are needed to advance the energy frontier in high energy physics and accelerator physics. Laser plasma accelerators are core to advanced accelerator concepts aimed at reaching TeV electron electron colliders. In these facilities, intense laser pulses drive plasmas and are used to accelerate electrons to high energies in remarkably short distances. A laser plasma accele…
▽ More
Large scale laser facilities are needed to advance the energy frontier in high energy physics and accelerator physics. Laser plasma accelerators are core to advanced accelerator concepts aimed at reaching TeV electron electron colliders. In these facilities, intense laser pulses drive plasmas and are used to accelerate electrons to high energies in remarkably short distances. A laser plasma accelerator could in principle reach high energies with an accelerating length that is 1000 times shorter than in conventional RF based accelerators. Notionally, laser driven particle beam energies could scale beyond state of the art conventional accelerators. LPAs have produced multi GeV electron beams in about 20 cm with relative energy spread of about 2 percent, supported by highly developed laser technology. This validates key elements of the US DOE strategy for such accelerators to enable future colliders but extending best results to date to a TeV collider will require lasers with higher average power. While the per pulse energies envisioned for laser driven colliders are achievable with current lasers, low laser repetition rates limit potential collider luminosity. Applications will require rates of kHz to tens of kHz at Joules of energy and high efficiency, and a collider would require about 100 such stages, a leap from current Hz class LPAs. This represents a challenging 1000 fold increase in laser repetition rates beyond current state of the art. This whitepaper describes current research and outlook for candidate laser systems as well as the accompanying broadband and high damage threshold optics needed for driving future advanced accelerators.
△ Less
Submitted 2 May, 2022; v1 submitted 22 April, 2022;
originally announced April 2022.
-
Constraints on Spin-Independent Nucleus Scattering with sub-GeV Weakly Interacting Massive Particle Dark Matter from the CDEX-1B Experiment at the China **-** Laboratory
Authors:
Z. Z. Liu,
Q. Yue,
L. T. Yang,
K. J. Kang,
Y. J. Li,
H. T. Wong,
M. Agartioglu,
H. P. An,
J. P. Chang,
J. H. Chen,
Y. H. Chen,
J. P. Cheng,
Z. Deng,
Q. Du,
H. Gong,
X. Y. Guo,
L. He,
S. M. He,
J. W. Hu,
Q. D. Hu,
H. X. Huang,
L. P. Jia,
H. Jiang,
H. B. Li,
H. Li
, et al. (46 additional authors not shown)
Abstract:
We report results on the searches of weakly interacting massive particles (WIMPs) with sub-GeV masses ($m_χ$) via WIMP-nucleus spin-independent scattering with Migdal effect incorporated. Analysis on time-integrated (TI) and annual modulation (AM) effects on CDEX-1B data are performed, with 737.1 kg$\cdot$day exposure and 160 eVee threshold for TI analysis, and 1107.5 kg$\cdot$day exposure and 250…
▽ More
We report results on the searches of weakly interacting massive particles (WIMPs) with sub-GeV masses ($m_χ$) via WIMP-nucleus spin-independent scattering with Migdal effect incorporated. Analysis on time-integrated (TI) and annual modulation (AM) effects on CDEX-1B data are performed, with 737.1 kg$\cdot$day exposure and 160 eVee threshold for TI analysis, and 1107.5 kg$\cdot$day exposure and 250 eVee threshold for AM analysis. The sensitive windows in $m_χ$ are expanded by an order of magnitude to lower DM masses with Migdal effect incorporated. New limits on $σ_{χN}^{\rm SI}$ at 90\% confidence level are derived as $2\times$10$^{-32}\sim7\times$10$^{-35}$ $\rm cm^2$ for TI analysis at $m_χ\sim$ 50$-$180 MeV/$c^2$, and $3\times$10$^{-32}\sim9\times$10$^{-38}$ $\rm cm^2$ for AM analysis at $m_χ\sim$75 MeV/$c^2-$3.0 GeV/$c^2$.
△ Less
Submitted 15 October, 2019; v1 submitted 1 May, 2019;
originally announced May 2019.
-
Search for Light Weakly-Interacting-Massive-Particle Dark Matter by Annual Modulation Analysis with a Point-Contact Germanium Detector at the China **** Underground Laboratory
Authors:
L. T. Yang,
H. B. Li,
Q. Yue,
H. Ma,
K. J. Kang,
Y. J. Li,
H. T. Wong,
M. Agartioglu,
H. P. An,
J. P. Chang,
J. H. Chen,
Y. H. Chen,
J. P. Cheng,
Z. Deng,
Q. Du,
H. Gong,
Q. J. Guo,
L. He,
J. W. Hu,
Q. D. Hu,
H. X. Huang,
L. P. Jia,
H. Jiang,
H. Li,
J. M. Li
, et al. (50 additional authors not shown)
Abstract:
We present results on light weakly interacting massive particle (WIMP) searches with annual modulation (AM) analysis on data from a 1-kg mass $p$-type point-contact germanium detector of the CDEX-1B experiment at the China **** Underground Laboratory. Datasets with a total live time of 3.2 yr within a 4.2 yr span are analyzed with analysis threshold of 250 eVee. Limits on WIMP-nucleus ($χ$-$N$)…
▽ More
We present results on light weakly interacting massive particle (WIMP) searches with annual modulation (AM) analysis on data from a 1-kg mass $p$-type point-contact germanium detector of the CDEX-1B experiment at the China **** Underground Laboratory. Datasets with a total live time of 3.2 yr within a 4.2 yr span are analyzed with analysis threshold of 250 eVee. Limits on WIMP-nucleus ($χ$-$N$) spin-independent cross sections as function of WIMP mass ($m_χ$) at 90\% confidence level (C.L.) are derived using the dark matter halo model. Within the context of the standard halo model, the 90\% C.L. allowed regions implied by the DAMA/LIBRA and CoGeNT AM-based analysis are excluded at $>$99.99\% and 98\% C.L., respectively. These results correspond to the best sensitivity at $m_χ$$<$6$~{\rm GeV}/c^2$ among WIMP AM measurements to date.
△ Less
Submitted 25 November, 2019; v1 submitted 29 April, 2019;
originally announced April 2019.
-
Performances of a prototype point-contact germanium detector immersed in liquid nitrogen for light dark matter search
Authors:
H. Jiang,
L. T. Yang,
Q. Yue,
K. J. Kang,
J. P. Cheng,
Y. J. Li,
H. T. Wong,
M. Agartioglu,
H. P. An,
J. P. Chang,
J. H. Chen,
Y. H. Chen,
Z. Deng,
Q. Du,
H. Gong,
L. He,
J. W. Hu,
Q. D. Hu,
H. X. Huang,
L. P. Jia,
H. B. Li,
H. Li,
J. M. Li,
J. Li,
X. Li
, et al. (48 additional authors not shown)
Abstract:
The CDEX-10 experiment searches for light weakly-interacting massive particles, a form of dark matter, at the China **** underground laboratory, where approximately 10 kg of germanium detectors are arranged in an array and immersed in liquid nitrogen. Herein, we report on the experimental apparatus, detector characterization, and spectrum analysis of one prototype detector. Owing to the higher…
▽ More
The CDEX-10 experiment searches for light weakly-interacting massive particles, a form of dark matter, at the China **** underground laboratory, where approximately 10 kg of germanium detectors are arranged in an array and immersed in liquid nitrogen. Herein, we report on the experimental apparatus, detector characterization, and spectrum analysis of one prototype detector. Owing to the higher rise-time resolution of the CDEX-10 prototype detector as compared with CDEX-1B, we identified the origin of an observed category of extremely fast events. For data analysis of the CDEX-10 prototype, we introduced and applied an improved bulk/surface event discrimination method. The results of the new method were compared to those of the CDEX-1B spectrum. Both sets of results showed good consistency in the 0--12 keVee energy range, except for the 8.0 keV K-shell X-ray peak from the external copper.
△ Less
Submitted 20 October, 2018;
originally announced October 2018.
-
Limits on Light Weakly Interacting Massive Particles from the First 102.8 kg ${\times}$ day Data of the CDEX-10 Experiment
Authors:
H. Jiang,
L. P. Jia,
Q. Yue,
K. J. Kang,
J. P. Cheng,
Y. J. Li,
H. T. Wong,
M. Agartioglu,
H. P. An,
J. P. Chang,
J. H. Chen,
Y. H. Chen,
Z. Deng,
Q. Du,
H. Gong,
L. He,
J. W. Hu,
Q. D. Hu,
H. X. Huang,
H. B. Li,
H. Li,
J. M. Li,
J. Li,
X. Li,
X. Q. Li
, et al. (48 additional authors not shown)
Abstract:
We report the first results of a light weakly interacting massive particles (WIMPs) search from the CDEX-10 experiment with a 10 kg germanium detector array immersed in liquid nitrogen at the China **** Underground Laboratory with a physics data size of 102.8 kg day. At an analysis threshold of 160 eVee, improved limits of 8 $\times 10^{-42}$ and 3 $\times 10^{-36}$ cm$^{2}$ at a 90\% confidenc…
▽ More
We report the first results of a light weakly interacting massive particles (WIMPs) search from the CDEX-10 experiment with a 10 kg germanium detector array immersed in liquid nitrogen at the China **** Underground Laboratory with a physics data size of 102.8 kg day. At an analysis threshold of 160 eVee, improved limits of 8 $\times 10^{-42}$ and 3 $\times 10^{-36}$ cm$^{2}$ at a 90\% confidence level on spin-independent and spin-dependent WIMP-nucleon cross sections, respectively, at a WIMP mass ($m_χ$) of 5 GeV/${c}^2$ are achieved. The lower reach of $m_χ$ is extended to 2 GeV/${c}^2$.
△ Less
Submitted 26 June, 2018; v1 submitted 25 February, 2018;
originally announced February 2018.
-
Direct measurement of neutrons induced in lead by cosmic muons at a shallow underground site
Authors:
Qiang Du,
Iris Abt,
Anton Empl,
Chris Gooch,
Raphael Kneissl,
Shin Ted LIN,
Bela Majorovits,
Matteo Palermo,
Oliver Schulz,
Li Wang,
Qian YUE,
Anna Julia Zsigmond
Abstract:
Neutron production in lead by cosmic muons has been studied with a Gadolinium doped liquid scintillator detector. The detector was installed next to the Muon-Induced Neutron Indirect Detection EXperiment (MINIDEX), permanently located in the Tübingen shallow underground laboratory where the mean muon energy is approximately 7 GeV. The MINIDEX plastic scintillators were used to tag muons; the neutr…
▽ More
Neutron production in lead by cosmic muons has been studied with a Gadolinium doped liquid scintillator detector. The detector was installed next to the Muon-Induced Neutron Indirect Detection EXperiment (MINIDEX), permanently located in the Tübingen shallow underground laboratory where the mean muon energy is approximately 7 GeV. The MINIDEX plastic scintillators were used to tag muons; the neutrons were detected through neutron capture and neutron-induced nuclear recoil signals in the liquid scintillator detector. Results on the rates of observed neutron captures and nuclear recoils are presented and compared to predictions from GEANT4-9.6 and GEANT4-10.3. The predicted rates are significantly too low for both versions of GEANT4. For neutron capture events, the observation exceeds the predictions by factors of $ 1.65\,\pm\,0.02\,\textrm{(stat.)}\,\pm\,0.07\,\textrm{(syst.)} $ and $ 2.58\,\pm\,0.03\,\textrm{(stat.)}\,\pm\,0.11\,\textrm{(syst.)} $ for GEANT4-9.6 and GEANT4-10.3, respectively. For neutron nuclear recoil events, which require neutron energies above approximately 5 MeV, the factors are even larger, $ 2.22\,\pm\,0.05\,\textrm{(stat.)}\,\pm\,0.25\,\textrm{(syst.)} $ and $ 3.76\,\pm\,0.09\,\textrm{(stat.)}\,\pm\,0.41\,\textrm{(syst.)} $, respectively. Also presented is the first statistically significant measurement of the spectrum of neutrons induced by cosmic muons in lead between 5 and 40 MeV. It was obtained by unfolding the nuclear recoil spectrum. The observed neutron spectrum is harder than predicted by GEANT4. An investigation of the distribution of the time difference between muon tags and nuclear recoil signals confirms the validity of the unfolding procedure and shows that GEANT4 cannot properly describe the time distribution of nuclear recoil events. In general, the description of the data is worse for GEANT4-10.3 than for GEANT4-9.6.
△ Less
Submitted 7 May, 2018; v1 submitted 15 January, 2018;
originally announced January 2018.
-
Response of gadolinium doped liquid scintillator to charged particles: measurement based on intrinsic U/Th contamination
Authors:
Qiang Du,
Shin-Ted Lin,
Han-Tao He,
Shu-Kui Liu,
Chang-Jian Tang,
Li Wang,
Henry T. Wong,
Hao-Yang Xing,
Qian Yue,
**g-Jun Zhu
Abstract:
A measurement is reported for the response to charged particles of a liquid scintillator named EJ-335 doped with 0.5% gadolinium by weight. This liquid scintillator was used as the detection medium in a neutron detector. The measurement is based on the in-situ $α$-particles from the intrinsic Uranium and Thorium contamination in the scintillator. The $β$-$α$ and the $α$-$α$ cascade decays from the…
▽ More
A measurement is reported for the response to charged particles of a liquid scintillator named EJ-335 doped with 0.5% gadolinium by weight. This liquid scintillator was used as the detection medium in a neutron detector. The measurement is based on the in-situ $α$-particles from the intrinsic Uranium and Thorium contamination in the scintillator. The $β$-$α$ and the $α$-$α$ cascade decays from the U/Th decay chains were used to select $α$-particles. The contamination levels of U/Th were consequently measured to be $(5.54\pm0.15)\times 10^{-11}$ g/g, $(1.45\pm0.01)\times 10^{-10}$ g/g and $(1.07\pm0.01)\times 10^{-11}$ g/g for $^{232}$Th, $^{238}$U and $^{235}$U, respectively, assuming secular equilibrium. The stop** power of $α$-particles in the liquid scintillator was simulated by the TRIM software. Then the Birks constant, $kB$, of the scintillator for $α$-particles was determined to be $(7.28\pm0.23)$ mg/(cm$^{2}\cdot$MeV) by Birks' formulation. The response for protons is also presented assuming the $kB$ constant is the same as for $α$-particles.
△ Less
Submitted 6 March, 2018; v1 submitted 10 January, 2018;
originally announced January 2018.
-
Limits on light WIMPs with a 1 kg-scale germanium detector at 160 eVee physics threshold at the China **** Underground Laboratory
Authors:
L. T. Yang,
H. B. Li,
Q. Yue,
K. J. Kang,
J. P. Cheng,
Y. J. Li,
H. T. Wong,
M. Aǧartioǧlu,
H. P. An,
J. P. Chang,
J. H. Chen,
Y. H. Chen,
Z. Deng,
Q. Du,
H. Gong,
L. He,
J. W. Hu,
Q. D. Hu,
H. X. Huang,
L. P. Jia,
H. Jiang,
H. Li,
J. M. Li,
J. Li,
X. Li
, et al. (43 additional authors not shown)
Abstract:
We report results of a search for light weakly interacting massive particle (WIMP) dark matter from the CDEX-1 experiment at the China **** Underground Laboratory (CJPL). Constraints on WIMP-nucleon spin-independent (SI) and spin-dependent (SD) couplings are derived with a physics threshold of 160 eVee, from an exposure of 737.1 kg-days. The SI and SD limits extend the lower reach of light WIMP…
▽ More
We report results of a search for light weakly interacting massive particle (WIMP) dark matter from the CDEX-1 experiment at the China **** Underground Laboratory (CJPL). Constraints on WIMP-nucleon spin-independent (SI) and spin-dependent (SD) couplings are derived with a physics threshold of 160 eVee, from an exposure of 737.1 kg-days. The SI and SD limits extend the lower reach of light WIMPs to 2 GeV and improve over our earlier bounds at WIMP mass less than 6 GeV.
△ Less
Submitted 26 June, 2018; v1 submitted 18 October, 2017;
originally announced October 2017.
-
The Large Enriched Germanium Experiment for Neutrinoless Double Beta Decay (LEGEND)
Authors:
LEGEND Collaboration,
N. Abgrall,
A. Abramov,
N. Abrosimov,
I. Abt,
M. Agostini,
M. Agartioglu,
A. Ajjaq,
S. I. Alvis,
F. T. Avignone III,
X. Bai,
M. Balata,
I. Barabanov,
A. S. Barabash,
P. J. Barton,
L. Baudis,
L. Bezrukov,
T. Bode,
A. Bolozdynya,
D. Borowicz,
A. Boston,
H. Boston,
S. T. P. Boyd,
R. Breier,
V. Brudanin
, et al. (208 additional authors not shown)
Abstract:
The observation of neutrinoless double-beta decay (0$νββ$) would show that lepton number is violated, reveal that neutrinos are Majorana particles, and provide information on neutrino mass. A discovery-capable experiment covering the inverted ordering region, with effective Majorana neutrino masses of 15 - 50 meV, will require a tonne-scale experiment with excellent energy resolution and extremely…
▽ More
The observation of neutrinoless double-beta decay (0$νββ$) would show that lepton number is violated, reveal that neutrinos are Majorana particles, and provide information on neutrino mass. A discovery-capable experiment covering the inverted ordering region, with effective Majorana neutrino masses of 15 - 50 meV, will require a tonne-scale experiment with excellent energy resolution and extremely low backgrounds, at the level of $\sim$0.1 count /(FWHM$\cdot$t$\cdot$yr) in the region of the signal. The current generation $^{76}$Ge experiments GERDA and the MAJORANA DEMONSTRATOR utilizing high purity Germanium detectors with an intrinsic energy resolution of 0.12%, have achieved the lowest backgrounds by over an order of magnitude in the 0$νββ$ signal region of all 0$νββ$ experiments. Building on this success, the LEGEND collaboration has been formed to pursue a tonne-scale $^{76}$Ge experiment. The collaboration aims to develop a phased 0$νββ$ experimental program with discovery potential at a half-life approaching or at $10^{28}$ years, using existing resources as appropriate to expedite physics results.
△ Less
Submitted 6 September, 2017;
originally announced September 2017.
-
Measurement of the fast neutron background at the China **** Underground Laboratory
Authors:
Qiang Du,
Shin-Ted Lin,
Shu-Kui Liu,
Chang-Jian Tang,
Li Wang,
Wei-Wei Wei,
Henry T. Wong,
Hao-Yang Xing,
Qian Yue,
**g-Jun Zhu
Abstract:
We report on the measurements of the fluxes and spectra of the environmental fast neutron background at the China **** Underground Laboratory (CJPL) with a rock overburden of about 6700 meters water equivalent, using a liquid scintillator detector doped with 0.5% gadolinium. The signature of a prompt nuclear recoil followed by a delayed high energy $γ$-ray cascade is used to identify neutron ev…
▽ More
We report on the measurements of the fluxes and spectra of the environmental fast neutron background at the China **** Underground Laboratory (CJPL) with a rock overburden of about 6700 meters water equivalent, using a liquid scintillator detector doped with 0.5% gadolinium. The signature of a prompt nuclear recoil followed by a delayed high energy $γ$-ray cascade is used to identify neutron events. The large energy deposition of the delayed $γ$-rays from the $(n, γ)$ reaction on gadolinium, together with the excellent n-$γ$ discrimination capability provides a powerful background suppression which allows the measurement of a low intensity neutron flux. The neutron flux of $(1.51\pm0.03(stat.)\pm0.10(syst.))\times10^{-7}$ cm$^{-2}$s$^{-1}$ in the energy range of 1 -- 10 MeV in the Hall A of CJPL was measured based on 356 days of data. In the same energy region, measurement with the same detector placed in a one meter thick polyethylene room gives a significantly lower flux of $(4.9\pm0.9(stat.)\pm0.5(syst.))\times10^{-9}$ cm$^{-2}$s$^{-1}$ with 174 days of data. This represents a measurement of the lowest environmental fast neutron background among the underground laboratories in the world, prior to additional experiment-specific attenuation. Additionally, the fast neutron spectra both in the Hall A and the polyethylene room were reconstructed with the help of GEANT4 simulation.
△ Less
Submitted 17 October, 2017; v1 submitted 21 June, 2017;
originally announced June 2017.
-
The first result on 76Ge neutrinoless double beta decay from CDEX-1 experiment
Authors:
Li Wang,
Qian Yue,
KeJun Kang,
Jian** Cheng,
Yuan**g Li,
TszKing Henry Wong,
ShinTed Lin,
Jian** Chang,
**gHan Chen,
QingHao Chen,
YunHua Chen,
Zhi Deng,
Qiang Du,
Hui Gong,
Li He,
QingJu He,
**Wei Hu,
HanXiong Huang,
TengRui Huang,
Li** Jia,
Hao Jiang,
HauBin Li,
Hong Li,
JianMin Li,
** Li
, et al. (48 additional authors not shown)
Abstract:
We report the first result on Ge-76 neutrinoless double beta decay from CDEX-1 experiment at China **** Underground Laboratory. A mass of 994 g p-type point-contact high purity germanium detector has been installed to search the neutrinoless double beta decay events, as well as to directly detect dark matter particles. An exposure of 304 kg*day has been analyzed. The wideband spectrum from 500…
▽ More
We report the first result on Ge-76 neutrinoless double beta decay from CDEX-1 experiment at China **** Underground Laboratory. A mass of 994 g p-type point-contact high purity germanium detector has been installed to search the neutrinoless double beta decay events, as well as to directly detect dark matter particles. An exposure of 304 kg*day has been analyzed. The wideband spectrum from 500 keV to 3 MeV was obtained and the average event rate at the 2.039 MeV energy range is about 0.012 count per keV per kg per day. The half-life of Ge-76 neutrinoless double beta decay has been derived based on this result as: T 1/2 > 6.4*10^22 yr (90% C.L.). An upper limit on the effective Majorana-neutrino mass of 5.0 eV has been achieved. The possible methods to further decrease the background level have been discussed and will be pursued in the next stage of CDEX experiment.
△ Less
Submitted 6 March, 2017;
originally announced March 2017.
-
Constraints on Axion couplings from the CDEX-1 experiment at the China **** Underground Laboratory
Authors:
S. K. Liu,
Q. Yue,
K. J. Kang,
J. P. Cheng,
H. T. Wong,
Y. J. Li,
H. B. Li,
S. T. Lin,
J. P. Chang,
J. H. Chen,
N. Chen,
Q. H. Chen,
Y. H. Chen,
Z. Deng,
Q. Du,
H. Gong,
H. J. He,
Q. J. He,
H. X. Huang,
H. Jiang,
J. M. Li,
J. Li,
J. Li,
X. Li,
X. Q. Li
, et al. (49 additional authors not shown)
Abstract:
We report the results of searches for solar axions and galactic dark matter axions or axion-like particles with CDEX-1 experiment at the China **** Underground Laboratory, using 335.6 kg-days of data from a p-type point-contact germanium detector. The data are compatible with the background model and no excess signals are observed. Limits of solar axions on the model independent coupling…
▽ More
We report the results of searches for solar axions and galactic dark matter axions or axion-like particles with CDEX-1 experiment at the China **** Underground Laboratory, using 335.6 kg-days of data from a p-type point-contact germanium detector. The data are compatible with the background model and no excess signals are observed. Limits of solar axions on the model independent coupling $g_{Ae}<2.5\times10^{-11}$ from Compton, bremsstrahlung, atomic-recombination and deexcitation channel and $g^{\text{eff}}_{AN}\times g_{Ae}<6.1\times10^{-17}$ from $^{57}$Fe M1 transition at 90 % confidence level are derived. Within the framework of the DFSZ and KSVZ models, our results exclude the axion mass heavier than 0.9 eV/c$^{2}$ and 173 eV/c$^{2}$, respectively. The derived constraints for dark matter axions below 1 keV improves over the previous results.
△ Less
Submitted 24 October, 2016;
originally announced October 2016.
-
A Search of Low-Mass WIMPs with p-type Point Contact Germanium Detector in the CDEX-1 Experiment
Authors:
W. Zhao,
Q. Yue,
K. J. Kang,
J. P. Cheng,
Y. J. Li,
H. T. Wong,
S. T. Lin,
J. P. Chang,
J. H. Chen,
Q. H. Chen,
Y. H. Chen,
Z. Deng,
Q. Du,
H. Gong,
X. Q. Hao,
H. J. He,
Q. J. He,
H. X. Huang,
T. R. Huang,
H. Jiang,
H. B. Li,
J. Li,
J. Li,
J. M. Li,
X. Li
, et al. (48 additional authors not shown)
Abstract:
The CDEX-1 experiment conducted a search of low-mass (< 10 GeV/c2) Weakly Interacting Massive Particles (WIMPs) dark matter at the China **** Underground Laboratory using a p-type point-contact germanium detector with a fiducial mass of 915 g at a physics analysis threshold of 475 eVee. We report the hardware set-up, detector characterization, data acquisition and analysis procedures of this ex…
▽ More
The CDEX-1 experiment conducted a search of low-mass (< 10 GeV/c2) Weakly Interacting Massive Particles (WIMPs) dark matter at the China **** Underground Laboratory using a p-type point-contact germanium detector with a fiducial mass of 915 g at a physics analysis threshold of 475 eVee. We report the hardware set-up, detector characterization, data acquisition and analysis procedures of this experiment. No excess of unidentified events are observed after subtraction of known background. Using 335.6 kg-days of data, exclusion constraints on the WIMP-nucleon spin-independent and spin-dependent couplings are derived.
△ Less
Submitted 18 January, 2016;
originally announced January 2016.
-
Characterization and Performance of Germanium Detectors with sub-keV Sensitivities for Neutrino and Dark Matter Experiments
Authors:
The TEXONO Collaboration,
A. K. Soma,
M. K. Singh,
L. Singh,
G. Kiran Kumar,
F. K. Lin,
Q. Du,
H. Jiang,
S. K. Liu,
J. L. Ma,
V. Sharma,
L. Wang,
Y. C. Wu,
L. T. Yang,
W. Zhao,
M. Agartioglu,
G. Asryan,
Y. Y. Chang,
J. H. Chen,
Y. C. Chuang,
M. Deniz,
C. L. Hsu,
Y. H. Hsu,
T. R. Huang,
L. P. Jia
, et al. (24 additional authors not shown)
Abstract:
Germanium ionization detectors with sensitivities as low as 100 eVee (electron-equivalent energy) open new windows for studies on neutrino and dark matter physics. The relevant physics subjects are summarized. The detectors have to measure physics signals whose amplitude is comparable to that of pedestal electronic noise. To fully exploit this new detector technique, various experimental issues in…
▽ More
Germanium ionization detectors with sensitivities as low as 100 eVee (electron-equivalent energy) open new windows for studies on neutrino and dark matter physics. The relevant physics subjects are summarized. The detectors have to measure physics signals whose amplitude is comparable to that of pedestal electronic noise. To fully exploit this new detector technique, various experimental issues including quenching factors, energy reconstruction and calibration, signal triggering and selection as well as evaluation of their associated efficiencies have to be attended. The efforts and results of a research program to address these challenges are presented.
△ Less
Submitted 1 September, 2016; v1 submitted 18 November, 2014;
originally announced November 2014.
-
Limits on light WIMPs from the CDEX-1 experiment with a p-type point-contact germanium detector at the China **g** Underground Laboratory
Authors:
Q. Yue,
W. Zhao,
K. J. Kang,
J. P. Cheng,
Y. J. Li,
S. T. Lin,
J. P. Chang,
N. Chen,
Q. H. Chen,
Y. H. Chen,
Y. C. Chuang,
Z. Deng,
Q. Du,
H. Gong,
X. Q. Hao,
H. J. He,
Q. J. He,
H. X. Huang,
T. R. Huang,
H. Jiang,
H. B. Li,
J. M. Li,
J. Li,
J. Li,
X. Li
, et al. (49 additional authors not shown)
Abstract:
We report results of a search for light Dark Matter WIMPs with CDEX-1 experiment at the China **** Underground Laboratory, based on 53.9 kg-days of data from a p-type point-contact germanium detector enclosed by a NaI(Tl) crystal scintillator as anti-Compton detector. The event rate and spectrum above the analysis threshold of 475 eVee are consistent with the understood background model. Part o…
▽ More
We report results of a search for light Dark Matter WIMPs with CDEX-1 experiment at the China **** Underground Laboratory, based on 53.9 kg-days of data from a p-type point-contact germanium detector enclosed by a NaI(Tl) crystal scintillator as anti-Compton detector. The event rate and spectrum above the analysis threshold of 475 eVee are consistent with the understood background model. Part of the allowed regions for WIMP-nucleus coherent elastic scattering at WIMP mass of 6-20 GeV are probed and excluded. Independent of interaction channels, this result contradicts the interpretation that the anomalous excesses of the CoGeNT experiment are induced by Dark Matter, since identical detector techniques are used in both experiments.
△ Less
Submitted 10 November, 2014; v1 submitted 19 April, 2014;
originally announced April 2014.
-
Limits on light WIMPs with a germanium detector at 177 eVee threshold at the China **** Underground Laboratory
Authors:
S. K. Liu,
Q. Yue,
K. J. Kang,
J. P. Cheng,
H. T. Wong,
Y. J. Li,
S. T. Lin,
J. P. Chang,
N. Chen,
Q. H. Chen,
Y. H. Chen,
Y. C. Chuang,
Z. Deng,
Q. Du,
H. Gong,
X. Q. Hao,
H. J. He,
Q. J. He,
H. X. Huang,
T. R. Huang,
H. Jiang,
H. B. Li,
J. M. Li,
J. Li,
J. Li
, et al. (51 additional authors not shown)
Abstract:
The China Dark Matter Experiment reports results on light WIMP dark matter searches at the China **** Underground Laboratory with a germanium detector array with a total mass of 20 g. The physics threshold achieved is 177 eVee ("ee" represents electron equivalent energy) at 50% signal efficiency. With 0.784 kg-days of data, exclusion region on spin-independent coupling with the nucleon is deriv…
▽ More
The China Dark Matter Experiment reports results on light WIMP dark matter searches at the China **** Underground Laboratory with a germanium detector array with a total mass of 20 g. The physics threshold achieved is 177 eVee ("ee" represents electron equivalent energy) at 50% signal efficiency. With 0.784 kg-days of data, exclusion region on spin-independent coupling with the nucleon is derived, improving over our earlier bounds at WIMP mass less than 4.6 GeV.
△ Less
Submitted 1 August, 2014; v1 submitted 21 March, 2014;
originally announced March 2014.
-
First results on low-mass WIMP from the CDEX-1 experiment at the China **** underground Laboratory
Authors:
W. Zhao,
Q. Yue,
K. J. Kang,
J. P. Cheng,
Y. J. Li,
S. T. Lin,
Y. Bai,
Y. Bi,
J. P. Chang,
N. Chen,
N. Chen,
Q. H. Chen,
Y. H. Chen,
Y. C. Chuang,
Z. Deng,
C. Du,
Q. Du,
H. Gong,
X. Q. Hao,
H. J. He,
Q. J. He,
X. H. Hu,
H. X. Huang,
T. R. Huang,
H. Jiang
, et al. (54 additional authors not shown)
Abstract:
The China Dark matter Experiment collaboration reports the first experimental limit on WIMP dark matter from 14.6 kg-day of data taken with a 994 g p-type point-contact germanium detector at the China **** underground Laboratory where the rock overburden is more than 2400 m. The energy threshold achieved was 400 eVee. According to the 14.6 kg-day live data, we placed the limit of N= 1.75 * 10^{…
▽ More
The China Dark matter Experiment collaboration reports the first experimental limit on WIMP dark matter from 14.6 kg-day of data taken with a 994 g p-type point-contact germanium detector at the China **** underground Laboratory where the rock overburden is more than 2400 m. The energy threshold achieved was 400 eVee. According to the 14.6 kg-day live data, we placed the limit of N= 1.75 * 10^{-40} cm^{2} at 90% confidence level on the spin-independent cross-section at WIMP mass of 7 GeV before differentiating bulk signals from the surface backgrounds.
△ Less
Submitted 8 August, 2013; v1 submitted 18 June, 2013;
originally announced June 2013.
-
The CDEX-1 1 kg Point-Contact Germanium Detector for Low Mass Dark Matter Searches
Authors:
Ke-Jun Kang,
Qian Yue,
Yu-Cheng Wu,
Jian-** Cheng,
Yuan-**g Li,
Yang Bai,
Yong Bi,
Jian-** Chang,
Nan Chen,
Ning Chen,
Qing-Hao Chen,
Yun-Hua Chen,
You-Chun Chuang,
Zhi Dend,
Qiang Du,
Hui Gong,
Xi-Qing Hao,
Qing-Ju He,
Xin-Hui Hu,
Han-Xiong Huang,
Teng-Rui Huang,
Hao Jiang,
Hau-Bin Li,
Jian-Min Li,
** Li
, et al. (51 additional authors not shown)
Abstract:
The CDEX Collaboration has been established for direct detection of light dark matter particles, using ultra-low energy threshold p-type point-contact germanium detectors, in China **** underground Laboratory (CJPL). The first 1 kg point-contact germanium detector with a sub-keV energy threshold has been tested in a passive shielding system located in CJPL. The outputs from both the point-conta…
▽ More
The CDEX Collaboration has been established for direct detection of light dark matter particles, using ultra-low energy threshold p-type point-contact germanium detectors, in China **** underground Laboratory (CJPL). The first 1 kg point-contact germanium detector with a sub-keV energy threshold has been tested in a passive shielding system located in CJPL. The outputs from both the point-contact p+ electrode and the outside n+ electrode make it possible to scan the lower energy range of less than 1 keV and at the same time to detect the higher energy range up to 3 MeV. The outputs from both p+ and n+ electrode may also provide a more powerful method for signal discrimination for dark matter experiment. Some key parameters, including energy resolution, dead time, decay times of internal X-rays, and system stability, have been tested and measured. The results show that the 1 kg point-contact germanium detector, together with its shielding system and electronics, can run smoothly with good performances. This detector system will be deployed for dark matter search experiments.
△ Less
Submitted 2 May, 2013;
originally announced May 2013.
-
Introduction of the CDEX experiment
Authors:
Ke-Jun Kang,
Jian-** Cheng,
** Li,
Yuan-**g Li,
Qian Yue,
Yang Bai,
Yong Bi,
Jian-** Chang,
Nan Chen,
Ning Chen,
Qing-Hao Chen,
Yun-Hua Chen,
Zhi Deng,
Qiang Du,
Hui Gong,
Xi-Qing Hao,
Hong-Jian He,
Qing-Ju He,
Xin-Hui Hu,
Han-Xiong Huang,
Hao Jiang,
Jian-Min Li,
Xia Li,
Xin-Ying Li,
Xue-Qian Li
, et al. (39 additional authors not shown)
Abstract:
Weakly Interacting Massive Particles (WIMPs) are the candidates of dark matter in our universe. Up to now any direct interaction of WIMP with nuclei has not been observed yet. The exclusion limits of the spin-independent cross section of WIMP-nucleon which have been experimentally obtained is about 10^{-7}pb at high mass region and only 10^{-5}pb} at low mass region. China **-** underground lab…
▽ More
Weakly Interacting Massive Particles (WIMPs) are the candidates of dark matter in our universe. Up to now any direct interaction of WIMP with nuclei has not been observed yet. The exclusion limits of the spin-independent cross section of WIMP-nucleon which have been experimentally obtained is about 10^{-7}pb at high mass region and only 10^{-5}pb} at low mass region. China **-** underground laboratory CJPL is the deepest underground lab in the world and provides a very promising environment for direct observation of dark matter. The China Dark Matter Experiment (CDEX) experiment is going to directly detect the WIMP flux with high sensitivity in the low mass region. Both CJPL and CDEX have achieved a remarkable progress in recent two years. The CDEX employs a point-contact germanium semi-conductor detector PCGe whose detection threshold is less than 300 eV. We report the measurement results of Muon flux, monitoring of radioactivity and Radon concentration carried out in CJPL, as well describe the structure and performance of the 1 kg PCGe detector CDEX-1 and 10kg detector array CDEX-10 including the detectors, electronics, shielding and cooling systems. Finally we discuss the physics goals of the CDEX-1, CDEX-10 and the future CDEX-1T detectors.
△ Less
Submitted 3 March, 2013;
originally announced March 2013.