-
Comparison of readout systems for high-rate silicon photo-multiplier applications
Authors:
M. L. Wong,
M. Kołodziej,
K. Briggl,
R. Hetzel,
G. Korcyl,
R. Lalik,
A. Malige,
A. Magiera,
G. Ostrzołek,
K. Rusiecka,
A. Stahl,
V. Urbanevych,
M. Wiebusch,
A. Wrońska
Abstract:
Recent years have shown an increased use of silicon photo-multipliers (SiPM) in experiments as they are of reasonable cost, have relatively low power consumption and are easily available in a variety of form factors allowing for a large number of readout channels. At the same time, experiments are generating data at increasingly high rates requiring the use of more efficient readout systems. In th…
▽ More
Recent years have shown an increased use of silicon photo-multipliers (SiPM) in experiments as they are of reasonable cost, have relatively low power consumption and are easily available in a variety of form factors allowing for a large number of readout channels. At the same time, experiments are generating data at increasingly high rates requiring the use of more efficient readout systems. In this work, the dead time, efficiency, dynamic range, coincidence time resolution and energy resolution of five different readout systems at various stages of maturity are evaluated to determine the best system for acquiring data from a detector in a high rate experiment. Additional functionalities of the systems are also discussed.
△ Less
Submitted 8 December, 2023;
originally announced December 2023.
-
Evaluation of the KLauS ASIC at low temperature
Authors:
Wei Wang,
Wei Shen,
Zhenxiong Yuan,
Konrad Briggl,
Hans-Christian Schultz-Coulon,
Wenqi Yan,
Guofu Cao,
Zepeng Li,
Ming Qi,
Liangjian Wen
Abstract:
The Taishan Antineutrino Observatory (TAO) is proposed to first use a cold liquid scintillator detector (-50~$^\circ$C) equipped with large-area silicon photomultipliers (SiPMs) ($\sim$10~m$^2$) to precisely measure the reactor antineutrino spectrum with a record energy resolution of < 2\% at 1 MeV. The KLauS ASIC shows excellent performance at room temperature and is a potential readout solution…
▽ More
The Taishan Antineutrino Observatory (TAO) is proposed to first use a cold liquid scintillator detector (-50~$^\circ$C) equipped with large-area silicon photomultipliers (SiPMs) ($\sim$10~m$^2$) to precisely measure the reactor antineutrino spectrum with a record energy resolution of < 2\% at 1 MeV. The KLauS ASIC shows excellent performance at room temperature and is a potential readout solution for TAO. In this work, we report evaluations of the fifth version of the KLauS ASIC (KLauS5) from room temperature to -50~$^\circ$C with inputs of injected charge or SiPMs. Our results show that KLauS5 has good performance at the tested temperatures with no significant degradation of the charge noise, charge linearity, gain uniformity or recovery time. Meanwhile, we also observe that several key parameters degrade when the chip operates in cold conditions, including the dynamic range and power consumption. However, even with this degradation, a good signal-to-noise ratio and good resolution of a single photoelectron can still be achieved for the tested SiPM with a gain of greater than 1.5$\times$10$^6$ and even an area of SiPM up to 1~cm$^2$ in one channel, corresponding to an input capacitance of approximately 5~nF. Thus, we conclude that KLauS5 can fulfill the TAO requirements for precise charge measurement.
△ Less
Submitted 11 November, 2020; v1 submitted 11 November, 2020;
originally announced November 2020.
-
Technical design of the phase I Mu3e experiment
Authors:
K. Arndt,
H. Augustin,
P. Baesso,
N. Berger,
F. Berg,
C. Betancourt,
D. Bortoletto,
A. Bravar,
K. Briggl,
D. vom Bruch,
A. Buonaura,
F. Cadoux,
C. Chavez Barajas,
H. Chen,
K. Clark,
P. Cooke,
S. Corrodi,
A. Damyanova,
Y. Demets,
S. Dittmeier,
P. Eckert,
F. Ehrler,
D. Fahrni,
S. Gagneur,
L. Gerritzen
, et al. (80 additional authors not shown)
Abstract:
The Mu3e experiment aims to find or exclude the lepton flavour violating decay $μ\rightarrow eee$ at branching fractions above $10^{-16}$. A first phase of the experiment using an existing beamline at the Paul Scherrer Institute (PSI) is designed to reach a single event sensitivity of $2\cdot 10^{-15}$. We present an overview of all aspects of the technical design and expected performance of the p…
▽ More
The Mu3e experiment aims to find or exclude the lepton flavour violating decay $μ\rightarrow eee$ at branching fractions above $10^{-16}$. A first phase of the experiment using an existing beamline at the Paul Scherrer Institute (PSI) is designed to reach a single event sensitivity of $2\cdot 10^{-15}$. We present an overview of all aspects of the technical design and expected performance of the phase~I Mu3e detector. The high rate of up to $10^{8}$ muon decays per second and the low momenta of the decay electrons and positrons pose a unique set of challenges, which we tackle using an ultra thin tracking detector based on high-voltage monolithic active pixel sensors combined with scintillating fibres and tiles for precise timing measurements.
△ Less
Submitted 26 August, 2021; v1 submitted 24 September, 2020;
originally announced September 2020.
-
Shower development of particles with momenta from 15 GeV to 150 GeV in the CALICE scintillator-tungsten hadronic calorimeter
Authors:
The CALICE collaboration,
M. Chefdeville,
Y. Karyotakis,
J. Repond,
J. Schlereth,
L. Xia,
G. Eigen,
J. S. Marshall,
M. A. Thomson,
D. R. Ward,
N. Alipour Tehrani,
J. Apostolakis,
D. Dannheim,
K. Elsener,
G. Folger,
C. Grefe,
V. Ivantchenko,
M. Killenberg,
W. Klempt,
E. van der Kraaij,
L. Linssen,
A. -I. Lucaci-Timoce,
A. Münnich,
S. Poss,
A. Ribon
, et al. (158 additional authors not shown)
Abstract:
We present a study of showers initiated by electrons, pions, kaons, and protons with momenta from 15 GeV to 150 GeV in the highly granular CALICE scintillator-tungsten analogue hadronic calorimeter. The data were recorded at the CERN Super Proton Synchrotron in 2011. The analysis includes measurements of the calorimeter response to each particle type as well as measurements of the energy resolutio…
▽ More
We present a study of showers initiated by electrons, pions, kaons, and protons with momenta from 15 GeV to 150 GeV in the highly granular CALICE scintillator-tungsten analogue hadronic calorimeter. The data were recorded at the CERN Super Proton Synchrotron in 2011. The analysis includes measurements of the calorimeter response to each particle type as well as measurements of the energy resolution and studies of the longitudinal and radial shower development for selected particles. The results are compared to Geant4 simulations (version 9.6.p02). In the study of the energy resolution we include previously published data with beam momenta from 1 GeV to 10 GeV recorded at the CERN Proton Synchrotron in 2010.
△ Less
Submitted 11 December, 2015; v1 submitted 2 September, 2015;
originally announced September 2015.
-
Pion and proton showers in the CALICE scintillator-steel analogue hadron calorimeter
Authors:
The CALICE Collaboration,
B. Bilki,
J. Repond,
L. Xia,
G. Eigen,
M. A. Thomson,
D. R. Ward,
D. Benchekroun,
A. Hoummada,
Y. Khoulaki,
S. Chang,
A. Khan,
D. H. Kim,
D. J. Kong,
Y. D. Oh,
G. C. Blazey,
A. Dyshkant,
K. Francis,
J. G. R. Lima,
R. Salcido,
V. Zutshi,
F. Salvatore,
K. Kawagoe,
Y. Miyazaki,
Y. Sudo
, et al. (147 additional authors not shown)
Abstract:
Showers produced by positive hadrons in the highly granular CALICE scintillator-steel analogue hadron calorimeter were studied. The experimental data were collected at CERN and FNAL for single particles with initial momenta from 10 to 80 GeV/c. The calorimeter response and resolution and spatial characteristics of shower development for proton- and pion-induced showers for test beam data and simul…
▽ More
Showers produced by positive hadrons in the highly granular CALICE scintillator-steel analogue hadron calorimeter were studied. The experimental data were collected at CERN and FNAL for single particles with initial momenta from 10 to 80 GeV/c. The calorimeter response and resolution and spatial characteristics of shower development for proton- and pion-induced showers for test beam data and simulations using Geant4 version 9.6 are compared.
△ Less
Submitted 15 March, 2015; v1 submitted 8 December, 2014;
originally announced December 2014.
-
The Time Structure of Hadronic Showers in highly granular Calorimeters with Tungsten and Steel Absorbers
Authors:
C. Adloff,
J. -J. Blaising,
M. Chefdeville,
C. Drancourt,
R. Gaglione,
N. Geffroy,
Y. Karyotakis,
I. Koletsou,
J. Prast,
G. Vouters J. Repond,
J. Schlereth,
L. Xia E. Baldolemar,
J. Li,
S. T. Park,
M. Sosebee,
A. P. White,
J. Yu,
G. Eigen,
M. A. Thomson,
D. R. Ward,
D. Benchekroun,
A. Hoummada,
Y. Khoulaki J. Apostolakis,
S. Arfaoui,
M. Benoit
, et al. (188 additional authors not shown)
Abstract:
The intrinsic time structure of hadronic showers influences the timing capability and the required integration time of hadronic calorimeters in particle physics experiments, and depends on the active medium and on the absorber of the calorimeter. With the CALICE T3B experiment, a setup of 15 small plastic scintillator tiles read out with Silicon Photomultipliers, the time structure of showers is m…
▽ More
The intrinsic time structure of hadronic showers influences the timing capability and the required integration time of hadronic calorimeters in particle physics experiments, and depends on the active medium and on the absorber of the calorimeter. With the CALICE T3B experiment, a setup of 15 small plastic scintillator tiles read out with Silicon Photomultipliers, the time structure of showers is measured on a statistical basis with high spatial and temporal resolution in sampling calorimeters with tungsten and steel absorbers. The results are compared to GEANT4 (version 9.4 patch 03) simulations with different hadronic physics models. These comparisons demonstrate the importance of using high precision treatment of low-energy neutrons for tungsten absorbers, while an overall good agreement between data and simulations for all considered models is observed for steel.
△ Less
Submitted 21 July, 2014; v1 submitted 25 April, 2014;
originally announced April 2014.
-
Performance of the first prototype of the CALICE scintillator strip electromagnetic calorimeter
Authors:
CALICE Collaboration,
K. Francis,
J. Repond,
J. Schlereth,
J. Smith,
L. Xia,
E. Baldolemar,
J. Li,
S. T. Park,
M. Sosebee,
A. P. White,
J. Yu,
G. Eigen,
Y. Mikami,
N. K. Watson,
M. A. Thomson,
D. R. Ward,
D. Benchekroun,
A. Hoummada,
Y. Khoulaki,
J. Apostolakis,
A. Dotti,
G. Folger,
V. Ivantchenko,
A. Ribon
, et al. (169 additional authors not shown)
Abstract:
A first prototype of a scintillator strip-based electromagnetic calorimeter was built, consisting of 26 layers of tungsten absorber plates interleaved with planes of 45x10x3 mm3 plastic scintillator strips. Data were collected using a positron test beam at DESY with momenta between 1 and 6 GeV/c. The prototype's performance is presented in terms of the linearity and resolution of the energy measur…
▽ More
A first prototype of a scintillator strip-based electromagnetic calorimeter was built, consisting of 26 layers of tungsten absorber plates interleaved with planes of 45x10x3 mm3 plastic scintillator strips. Data were collected using a positron test beam at DESY with momenta between 1 and 6 GeV/c. The prototype's performance is presented in terms of the linearity and resolution of the energy measurement. These results represent an important milestone in the development of highly granular calorimeters using scintillator strip technology. This technology is being developed for a future linear collider experiment, aiming at the precise measurement of jet energies using particle flow techniques.
△ Less
Submitted 11 June, 2014; v1 submitted 15 November, 2013;
originally announced November 2013.
-
Track segments in hadronic showers in a highly granular scintillator-steel hadron calorimeter
Authors:
CALICE Collaboration,
C. Adloff,
J. -J. Blaising,
M. Chefdeville,
C. Drancourt,
R. Gaglione,
N. Geffroy,
Y. Karyotakis,
I. Koletsou,
J. Prast,
G. Vouters,
K. Francis,
J. Repond,
J. Schlereth,
J. Smith,
L. Xia,
E. Baldolemar,
J. Li,
S. T. Park,
M. Sosebee,
A. P. White,
J. Yu,
G. Eigen,
Y. Mikami,
N. K. Watson
, et al. (184 additional authors not shown)
Abstract:
We investigate the three dimensional substructure of hadronic showers in the CALICE scintillator-steel hadronic calorimeter. The high granularity of the detector is used to find track segments of minimum ionising particles within hadronic showers, providing sensitivity to the spatial structure and the details of secondary particle production in hadronic cascades. The multiplicity, length and angul…
▽ More
We investigate the three dimensional substructure of hadronic showers in the CALICE scintillator-steel hadronic calorimeter. The high granularity of the detector is used to find track segments of minimum ionising particles within hadronic showers, providing sensitivity to the spatial structure and the details of secondary particle production in hadronic cascades. The multiplicity, length and angular distribution of identified track segments are compared to GEANT4 simulations with several different shower models. Track segments also provide the possibility for in-situ calibration of highly granular calorimeters.
△ Less
Submitted 29 July, 2013; v1 submitted 30 May, 2013;
originally announced May 2013.