-
The Belle II Detector Upgrades Framework Conceptual Design Report
Authors:
H. Aihara,
A. Aloisio,
D. P. Auguste,
M. Aversano,
M. Babeluk,
S. Bahinipati,
Sw. Banerjee,
M. Barbero,
J. Baudot,
A. Beaubien,
F. Becherer,
T. Bergauer,
F. U. Bernlochner.,
V. Bertacchi,
G. Bertolone,
C. Bespin,
M. Bessner,
S. Bettarini,
A. J. Bevan,
B. Bhuyan,
M. Bona,
J. F. Bonis,
J. Borah,
F. Bosi,
R. Boudagga
, et al. (186 additional authors not shown)
Abstract:
We describe the planned near-term and potential longer-term upgrades of the Belle II detector at the SuperKEKB electron-positron collider operating at the KEK laboratory in Tsukuba, Japan. These upgrades will allow increasingly sensitive searches for possible new physics beyond the Standard Model in flavor, tau, electroweak and dark sector physics that are both complementary to and competitive wit…
▽ More
We describe the planned near-term and potential longer-term upgrades of the Belle II detector at the SuperKEKB electron-positron collider operating at the KEK laboratory in Tsukuba, Japan. These upgrades will allow increasingly sensitive searches for possible new physics beyond the Standard Model in flavor, tau, electroweak and dark sector physics that are both complementary to and competitive with the LHC and other experiments.
△ Less
Submitted 4 July, 2024; v1 submitted 26 June, 2024;
originally announced June 2024.
-
Using graph neural networks to reconstruct charged pion showers in the CMS High Granularity Calorimeter
Authors:
M. Aamir,
B. Acar,
G. Adamov,
T. Adams,
C. Adloff,
S. Afanasiev,
C. Agrawal,
C. Agrawal,
A. Ahmad,
H. A. Ahmed,
S. Akbar,
N. Akchurin,
B. Akgul,
B. Akgun,
R. O. Akpinar,
E. Aktas,
A. AlKadhim,
V. Alexakhin,
J. Alimena,
J. Alison,
A. Alpana,
W. Alshehri,
P. Alvarez Dominguez,
M. Alyari,
C. Amendola
, et al. (550 additional authors not shown)
Abstract:
A novel method to reconstruct the energy of hadronic showers in the CMS High Granularity Calorimeter (HGCAL) is presented. The HGCAL is a sampling calorimeter with very fine transverse and longitudinal granularity. The active media are silicon sensors and scintillator tiles readout by SiPMs and the absorbers are a combination of lead and Cu/CuW in the electromagnetic section, and steel in the hadr…
▽ More
A novel method to reconstruct the energy of hadronic showers in the CMS High Granularity Calorimeter (HGCAL) is presented. The HGCAL is a sampling calorimeter with very fine transverse and longitudinal granularity. The active media are silicon sensors and scintillator tiles readout by SiPMs and the absorbers are a combination of lead and Cu/CuW in the electromagnetic section, and steel in the hadronic section. The shower reconstruction method is based on graph neural networks and it makes use of a dynamic reduction network architecture. It is shown that the algorithm is able to capture and mitigate the main effects that normally hinder the reconstruction of hadronic showers using classical reconstruction methods, by compensating for fluctuations in the multiplicity, energy, and spatial distributions of the shower's constituents. The performance of the algorithm is evaluated using test beam data collected in 2018 prototype of the CMS HGCAL accompanied by a section of the CALICE AHCAL prototype. The capability of the method to mitigate the impact of energy leakage from the calorimeter is also demonstrated.
△ Less
Submitted 30 June, 2024; v1 submitted 17 June, 2024;
originally announced June 2024.
-
Upgrade of Belle II Vertex Detector with CMOS Pixel Technology
Authors:
M. Schwickardi,
M. Babeluk,
M. Barbero,
J. Baudot,
T. Bergauer,
G. Bertolone,
S. Bettarini,
F. Bosi,
P. Breugnon,
Y. Buch,
G. Casarosa,
G. Dujany,
C. Finck,
F. Forti,
A. Frey,
A. Himmi,
C. Irmler,
A. Kumar,
C. Marinas,
M. Massa,
L. Massaccesi,
J. Mazzora de Cos,
M. Minuti,
S. Mondal,
P. Pangaud
, et al. (5 additional authors not shown)
Abstract:
The Belle II experiment at KEK in Japan considers upgrading its vertex detector system to address the challenges posed by high background levels caused by the increased luminosity of the SuperKEKB collider. One proposal for upgrading the vertex detector aims to install a 5-layer all monolithic pixel vertex detector based on fully depleted CMOS sensors in 2027. The new system will use the OBELIX MA…
▽ More
The Belle II experiment at KEK in Japan considers upgrading its vertex detector system to address the challenges posed by high background levels caused by the increased luminosity of the SuperKEKB collider. One proposal for upgrading the vertex detector aims to install a 5-layer all monolithic pixel vertex detector based on fully depleted CMOS sensors in 2027. The new system will use the OBELIX MAPS chips to improve background robustness and reduce occupancy levels through small and fast pixels. This causes better track finding, especially for low transverse momenta tracks. This text will focus on the predecessor of the OBELIX sensor, the TJ-Monopix2, presenting laboratory and test beam results on pixel response, efficiency, and spatial resolution.
△ Less
Submitted 12 December, 2023; v1 submitted 22 November, 2023;
originally announced November 2023.
-
RD50-MPW3: A fully monolithic digital CMOS sensor for future tracking detectors
Authors:
Patrick Sieberer,
Chenfan Zhang,
Thomas Bergauer,
Raimon Casanova Mohr,
Christian Irmler,
Nissar Karim,
Jose Mazorra de Cos,
Bernhard Pilsl,
Eva Vilella
Abstract:
The CERN-RD50 CMOS working group develops the RD50-MPWseries of monolithic high-voltage CMOS pixel sensors for potential use in future high luminosity experiments such as the HL-LHC and FCC-hh. In this contribution, the design of the latest prototype in this series, RD50-MPW3, is presented. An overview of its pixel matrix and digital readout periphery is given, with discussion of the new structure…
▽ More
The CERN-RD50 CMOS working group develops the RD50-MPWseries of monolithic high-voltage CMOS pixel sensors for potential use in future high luminosity experiments such as the HL-LHC and FCC-hh. In this contribution, the design of the latest prototype in this series, RD50-MPW3, is presented. An overview of its pixel matrix and digital readout periphery is given, with discussion of the new structures implemented in the chip and the problems they aim to solve. The main analog and digital features of the sensor are already tested and initial laboratory characterisation of the chip is presented.
△ Less
Submitted 17 January, 2023; v1 submitted 21 November, 2022;
originally announced November 2022.
-
4H-Silicon Carbide as particle detector for high-intensity ion beams
Authors:
Manuel Christanell,
Maximilian Tomaschek,
Thomas Bergauer
Abstract:
In ion cancer therapy, high-intensity ion beams are used to treat tumors by taking advantage of the Bragg-Peak. Typical ion therapy centers use particle rates up to $10^{10}$ ions/second for treatment. On the other hand, such intensities are often too high when using these beamlines for particle physics experiments or as a test-beam environment in general. The project presented here aims to develo…
▽ More
In ion cancer therapy, high-intensity ion beams are used to treat tumors by taking advantage of the Bragg-Peak. Typical ion therapy centers use particle rates up to $10^{10}$ ions/second for treatment. On the other hand, such intensities are often too high when using these beamlines for particle physics experiments or as a test-beam environment in general. The project presented here aims to develop a beam position and intensity monitor, to cover a wide intensity range from a few Hz up to GHz rates, as used in clinical settings. Silicon carbide (SiC) is an attractive detector material for this application because it combines potential high radiation hardness with high thermal conductivity to avoid cooling. Moreover, its high electron saturation velocity allows very fast signals to mitigate pile-ups. However, some special properties of the material like different crystal polytypes have to be considered. In this paper, measurements on both a pad and a micro-strip SiC sensor prototype of 4H lattice geometry are shown. The sensors were tested in the laboratory using radioactive sources and with a proton beam in a wide intensity range (kHz-GHz) and with different energies (60-800 MeV) available at MedAustron, an ion cancer therapy center located in Austria. The measurements show that MIP particles cannot be detected reliably with the used discrete electronics setup in combination with the single-channel sensor. However, the strip sensor combined with an ASIC-based readout electronics from the CMS/Belle-II experiments allows to recover a certain part of the signal. This makes it possible to determine the ionization energy and average number of electron/hole pairs generated in the studied sensor samples.
△ Less
Submitted 4 December, 2021;
originally announced December 2021.
-
Response of a CMS HGCAL silicon-pad electromagnetic calorimeter prototype to 20-300 GeV positrons
Authors:
B. Acar,
G. Adamov,
C. Adloff,
S. Afanasiev,
N. Akchurin,
B. Akgün,
F. Alam Khan,
M. Alhusseini,
J. Alison,
A. Alpana,
G. Altopp,
M. Alyari,
S. An,
S. Anagul,
I. Andreev,
P. Aspell,
I. O. Atakisi,
O. Bach,
A. Baden,
G. Bakas,
A. Bakshi,
S. Bannerjee,
P. Bargassa,
D. Barney,
F. Beaudette
, et al. (364 additional authors not shown)
Abstract:
The Compact Muon Solenoid Collaboration is designing a new high-granularity endcap calorimeter, HGCAL, to be installed later this decade. As part of this development work, a prototype system was built, with an electromagnetic section consisting of 14 double-sided structures, providing 28 sampling layers. Each sampling layer has an hexagonal module, where a multipad large-area silicon sensor is glu…
▽ More
The Compact Muon Solenoid Collaboration is designing a new high-granularity endcap calorimeter, HGCAL, to be installed later this decade. As part of this development work, a prototype system was built, with an electromagnetic section consisting of 14 double-sided structures, providing 28 sampling layers. Each sampling layer has an hexagonal module, where a multipad large-area silicon sensor is glued between an electronics circuit board and a metal baseplate. The sensor pads of approximately 1 cm$^2$ are wire-bonded to the circuit board and are readout by custom integrated circuits. The prototype was extensively tested with beams at CERN's Super Proton Synchrotron in 2018. Based on the data collected with beams of positrons, with energies ranging from 20 to 300 GeV, measurements of the energy resolution and linearity, the position and angular resolutions, and the shower shapes are presented and compared to a detailed Geant4 simulation.
△ Less
Submitted 31 March, 2022; v1 submitted 12 November, 2021;
originally announced November 2021.
-
Construction and commissioning of CMS CE prototype silicon modules
Authors:
B. Acar,
G. Adamov,
C. Adloff,
S. Afanasiev,
N. Akchurin,
B. Akgün,
M. Alhusseini,
J. Alison,
G. Altopp,
M. Alyari,
S. An,
S. Anagul,
I. Andreev,
M. Andrews,
P. Aspell,
I. A. Atakisi,
O. Bach,
A. Baden,
G. Bakas,
A. Bakshi,
P. Bargassa,
D. Barney,
E. Becheva,
P. Behera,
A. Belloni
, et al. (307 additional authors not shown)
Abstract:
As part of its HL-LHC upgrade program, the CMS Collaboration is develo** a High Granularity Calorimeter (CE) to replace the existing endcap calorimeters. The CE is a sampling calorimeter with unprecedented transverse and longitudinal readout for both electromagnetic (CE-E) and hadronic (CE-H) compartments. The calorimeter will be built with $\sim$30,000 hexagonal silicon modules. Prototype modul…
▽ More
As part of its HL-LHC upgrade program, the CMS Collaboration is develo** a High Granularity Calorimeter (CE) to replace the existing endcap calorimeters. The CE is a sampling calorimeter with unprecedented transverse and longitudinal readout for both electromagnetic (CE-E) and hadronic (CE-H) compartments. The calorimeter will be built with $\sim$30,000 hexagonal silicon modules. Prototype modules have been constructed with 6-inch hexagonal silicon sensors with cell areas of 1.1~$cm^2$, and the SKIROC2-CMS readout ASIC. Beam tests of different sampling configurations were conducted with the prototype modules at DESY and CERN in 2017 and 2018. This paper describes the construction and commissioning of the CE calorimeter prototype, the silicon modules used in the construction, their basic performance, and the methods used for their calibration.
△ Less
Submitted 10 December, 2020;
originally announced December 2020.
-
The DAQ system of the 12,000 Channel CMS High Granularity Calorimeter Prototype
Authors:
B. Acar,
G. Adamov,
C. Adloff,
S. Afanasiev,
N. Akchurin,
B. Akgün,
M. Alhusseini,
J. Alison,
G. Altopp,
M. Alyari,
S. An,
S. Anagul,
I. Andreev,
M. Andrews,
P. Aspell,
I. A. Atakisi,
O. Bach,
A. Baden,
G. Bakas,
A. Bakshi,
P. Bargassa,
D. Barney,
E. Becheva,
P. Behera,
A. Belloni
, et al. (307 additional authors not shown)
Abstract:
The CMS experiment at the CERN LHC will be upgraded to accommodate the 5-fold increase in the instantaneous luminosity expected at the High-Luminosity LHC (HL-LHC). Concomitant with this increase will be an increase in the number of interactions in each bunch crossing and a significant increase in the total ionising dose and fluence. One part of this upgrade is the replacement of the current endca…
▽ More
The CMS experiment at the CERN LHC will be upgraded to accommodate the 5-fold increase in the instantaneous luminosity expected at the High-Luminosity LHC (HL-LHC). Concomitant with this increase will be an increase in the number of interactions in each bunch crossing and a significant increase in the total ionising dose and fluence. One part of this upgrade is the replacement of the current endcap calorimeters with a high granularity sampling calorimeter equipped with silicon sensors, designed to manage the high collision rates. As part of the development of this calorimeter, a series of beam tests have been conducted with different sampling configurations using prototype segmented silicon detectors. In the most recent of these tests, conducted in late 2018 at the CERN SPS, the performance of a prototype calorimeter equipped with ${\approx}12,000\rm{~channels}$ of silicon sensors was studied with beams of high-energy electrons, pions and muons. This paper describes the custom-built scalable data acquisition system that was built with readily available FPGA mezzanines and low-cost Raspberry PI computers.
△ Less
Submitted 8 December, 2020; v1 submitted 7 December, 2020;
originally announced December 2020.
-
Observation of the rare $B^0_s\toμ^+μ^-$ decay from the combined analysis of CMS and LHCb data
Authors:
The CMS,
LHCb Collaborations,
:,
V. Khachatryan,
A. M. Sirunyan,
A. Tumasyan,
W. Adam,
T. Bergauer,
M. Dragicevic,
J. Erö,
M. Friedl,
R. Frühwirth,
V. M. Ghete,
C. Hartl,
N. Hörmann,
J. Hrubec,
M. Jeitler,
W. Kiesenhofer,
V. Knünz,
M. Krammer,
I. Krätschmer,
D. Liko,
I. Mikulec,
D. Rabady,
B. Rahbaran
, et al. (2807 additional authors not shown)
Abstract:
A joint measurement is presented of the branching fractions $B^0_s\toμ^+μ^-$ and $B^0\toμ^+μ^-$ in proton-proton collisions at the LHC by the CMS and LHCb experiments. The data samples were collected in 2011 at a centre-of-mass energy of 7 TeV, and in 2012 at 8 TeV. The combined analysis produces the first observation of the $B^0_s\toμ^+μ^-$ decay, with a statistical significance exceeding six sta…
▽ More
A joint measurement is presented of the branching fractions $B^0_s\toμ^+μ^-$ and $B^0\toμ^+μ^-$ in proton-proton collisions at the LHC by the CMS and LHCb experiments. The data samples were collected in 2011 at a centre-of-mass energy of 7 TeV, and in 2012 at 8 TeV. The combined analysis produces the first observation of the $B^0_s\toμ^+μ^-$ decay, with a statistical significance exceeding six standard deviations, and the best measurement of its branching fraction so far. Furthermore, evidence for the $B^0\toμ^+μ^-$ decay is obtained with a statistical significance of three standard deviations. The branching fraction measurements are statistically compatible with SM predictions and impose stringent constraints on several theories beyond the SM.
△ Less
Submitted 17 August, 2015; v1 submitted 17 November, 2014;
originally announced November 2014.
-
Infrastructure for Detector Research and Development towards the International Linear Collider
Authors:
J. Aguilar,
P. Ambalathankandy,
T. Fiutowski,
M. Idzik,
Sz. Kulis,
D. Przyborowski,
K. Swientek,
A. Bamberger,
M. Köhli,
M. Lupberger,
U. Renz,
M. Schumacher,
Andreas Zwerger,
A. Calderone,
D. G. Cussans,
H. F. Heath,
S. Mandry,
R. F. Page,
J. J. Velthuis,
D. Attié,
D. Calvet,
P. Colas,
X. Coppolani,
Y. Degerli,
E. Delagnes
, et al. (252 additional authors not shown)
Abstract:
The EUDET-project was launched to create an infrastructure for develo** and testing new and advanced detector technologies to be used at a future linear collider. The aim was to make possible experimentation and analysis of data for institutes, which otherwise could not be realized due to lack of resources. The infrastructure comprised an analysis and software network, and instrumentation infras…
▽ More
The EUDET-project was launched to create an infrastructure for develo** and testing new and advanced detector technologies to be used at a future linear collider. The aim was to make possible experimentation and analysis of data for institutes, which otherwise could not be realized due to lack of resources. The infrastructure comprised an analysis and software network, and instrumentation infrastructures for tracking detectors as well as for calorimetry.
△ Less
Submitted 23 January, 2012;
originally announced January 2012.
-
Belle II Technical Design Report
Authors:
T. Abe,
I. Adachi,
K. Adamczyk,
S. Ahn,
H. Aihara,
K. Akai,
M. Aloi,
L. Andricek,
K. Aoki,
Y. Arai,
A. Arefiev,
K. Arinstein,
Y. Arita,
D. M. Asner,
V. Aulchenko,
T. Aushev,
T. Aziz,
A. M. Bakich,
V. Balagura,
Y. Ban,
E. Barberio,
T. Barvich,
K. Belous,
T. Bergauer,
V. Bhardwaj
, et al. (387 additional authors not shown)
Abstract:
The Belle detector at the KEKB electron-positron collider has collected almost 1 billion Y(4S) events in its decade of operation. Super-KEKB, an upgrade of KEKB is under construction, to increase the luminosity by two orders of magnitude during a three-year shutdown, with an ultimate goal of 8E35 /cm^2 /s luminosity. To exploit the increased luminosity, an upgrade of the Belle detector has been pr…
▽ More
The Belle detector at the KEKB electron-positron collider has collected almost 1 billion Y(4S) events in its decade of operation. Super-KEKB, an upgrade of KEKB is under construction, to increase the luminosity by two orders of magnitude during a three-year shutdown, with an ultimate goal of 8E35 /cm^2 /s luminosity. To exploit the increased luminosity, an upgrade of the Belle detector has been proposed. A new international collaboration Belle-II, is being formed. The Technical Design Report presents physics motivation, basic methods of the accelerator upgrade, as well as key improvements of the detector.
△ Less
Submitted 1 November, 2010;
originally announced November 2010.
-
Resolution Studies on Silicon Strip Sensors with fine Pitch
Authors:
S. Haensel,
T. Bergauer,
Z. Dolezal,
M. Dragicevic,
Z. Drasal,
M. Friedl,
J. Hrubec,
C. Irmler,
W. Kiesenhofer,
M. Krammer,
P. Kvasnicka
Abstract:
In June 2008 single-sided silicon strip sensors with 50 $μ$m readout pitch were tested in a highly energetic pion beam at the SPS at CERN. The purpose of the test was to evaluate characteristic detector properties by varying the strip width and the number of intermediate strips. The experimental setup and first results for the spatial resolution are discussed.
In June 2008 single-sided silicon strip sensors with 50 $μ$m readout pitch were tested in a highly energetic pion beam at the SPS at CERN. The purpose of the test was to evaluate characteristic detector properties by varying the strip width and the number of intermediate strips. The experimental setup and first results for the spatial resolution are discussed.
△ Less
Submitted 19 February, 2009; v1 submitted 30 January, 2009;
originally announced January 2009.