Searches for new physics below twice the electron mass with GERDA
Authors:
GERDA Collaboration,
M. Agostini,
A. Alexander,
G. R. Araujo,
A. M. Bakalyarov,
M. Balata,
I. Barabanov,
L. Baudis,
C. Bauer,
S. Belogurov,
A. Bettini,
L. Bezrukov,
V. Biancacci,
E. Bossio,
V. Bothe,
R. Brugnera,
A. Caldwell,
S. Calgaro,
C. Cattadori,
A. Chernogorov,
P. -J. Chiu,
T. Comellato,
V. D'Andrea,
E. V. Demidova,
N. Di Marco
, et al. (86 additional authors not shown)
Abstract:
A search for full energy depositions from bosonic keV-scale dark matter candidates of masses between 65 keV and 1021 keV has been performed with data collected during Phase II of the GERmanium Detector Array (GERDA) experiment. Our analysis includes direct dark matter absorption as well as dark Compton scattering. With a total exposure of 105.5 kg yr, no evidence for a signal above the background…
▽ More
A search for full energy depositions from bosonic keV-scale dark matter candidates of masses between 65 keV and 1021 keV has been performed with data collected during Phase II of the GERmanium Detector Array (GERDA) experiment. Our analysis includes direct dark matter absorption as well as dark Compton scattering. With a total exposure of 105.5 kg yr, no evidence for a signal above the background has been observed. The resulting exclusion limits deduced with either Bayesian or Frequentist statistics are the most stringent direct constraints in the major part of the 140-1021 keV mass range. As an example, at a mass of 150 keV the dimensionless coupling of dark photons and axion-like particles to electrons has been constrained to $α$'/$α$ < 8.7x10$^{-24}$ and g$_{ae}$ < 3.3x10$^{-12}$ at 90% credible interval (CI), respectively. Additionally, a search for peak-like signals from beyond the Standard Model decays of nucleons and electrons is performed. We find for the inclusive decay of a single neutron in $^{76}$Ge a lower lifetime limit of $τ_n$ > 1.5x10$^{24}$ yr and for a proton $τ_p$ > 1.3x10$^{24}$ yr at 90% CI. For the electron decay e$^-\rightarrowν_eγ$ a lower limit of $τ_e$ > 5.4x10$^{25}$ yr at 90% CI has been determined.
△ Less
Submitted 24 May, 2024;
originally announced May 2024.
-
Mineral Detection of Neutrinos and Dark Matter 2024. Proceedings
Authors:
Sebastian Baum,
Patrick Huber,
Patrick Stengel,
Natsue Abe,
Daniel G. Ang,
Lorenzo Apollonio,
Gabriela R. Araujo,
Levente Balogh,
Pranshu Bhaumik Yilda Boukhtouchen,
Joseph Bramante,
Lorenzo Caccianiga,
Andrew Calabrese-Day,
Qing Chang,
Juan I. Collar,
Reza Ebadi,
Alexey Elykov,
Katherine Freese,
Audrey Fung,
Claudio Galelli,
Arianna E. Gleason,
Mariano Guerrero Perez,
Janina Hakenmüller,
Takeshi Hanyu,
Noriko Hasebe,
Shigenobu Hirose
, et al. (35 additional authors not shown)
Abstract:
The second "Mineral Detection of Neutrinos and Dark Matter" (MDvDM'24) meeting was held January 8-11, 2024 in Arlington, VA, USA, hosted by Virginia Tech's Center for Neutrino Physics. This document collects contributions from this workshop, providing an overview of activities in the field. MDvDM'24 was the second topical workshop dedicated to the emerging field of mineral detection of neutrinos a…
▽ More
The second "Mineral Detection of Neutrinos and Dark Matter" (MDvDM'24) meeting was held January 8-11, 2024 in Arlington, VA, USA, hosted by Virginia Tech's Center for Neutrino Physics. This document collects contributions from this workshop, providing an overview of activities in the field. MDvDM'24 was the second topical workshop dedicated to the emerging field of mineral detection of neutrinos and dark matter, following a meeting hosted by IFPU in Trieste, Italy in October 2022. Mineral detectors have been proposed for a wide variety of applications, including searching for dark matter, measuring various fluxes of astrophysical neutrinos over gigayear timescales, monitoring nuclear reactors, and nuclear disarmament protocols; both as paleo-detectors using natural minerals that could have recorded the traces of nuclear recoils for timescales as long as a billion years and as detectors recording nuclear recoil events on laboratory timescales using natural or artificial minerals. Contributions to this proceedings discuss the vast physics potential, the progress in experimental studies, and the numerous challenges lying ahead on the path towards mineral detection. These include a better understanding of the formation and annealing of recoil defects in crystals; identifying the best classes of minerals and, for paleo-detectors, understanding their geology; modeling and control of the relevant backgrounds; develo**, combining, and scaling up imaging and data analysis techniques; and many others. During the last years, MDvDM has grown rapidly and gained attention. Small-scale experimental efforts focused on establishing various microscopic readout techniques are underway at institutions in North America, Europe and Asia. We are looking ahead to an exciting future full of challenges to overcome, surprises to be encountered, and discoveries lying ahead of us.
△ Less
Submitted 2 May, 2024;
originally announced May 2024.
-
Precision Measurement of the Specific Activity of $^{39}$Ar in Atmospheric Argon with the DEAP-3600 Detector
Authors:
P. Adhikari,
R. Ajaj,
M. Alpízar-Venegas,
P. -A. Amaudruz,
J. Anstey,
G. R. Araujo,
D. J. Auty,
M. Baldwin,
M. Batygov,
B. Beltran,
H. Benmansour,
C. E. Bina,
J. Bonatt,
W. Bonivento,
M. G. Boulay,
B. Broerman,
J. F. Bueno,
P. M. Burghardt,
A. Butcher,
M. Cadeddu,
B. Cai,
M. Cárdenas-Montes,
S. Cavuoti,
M. Chen,
Y. Chen
, et al. (125 additional authors not shown)
Abstract:
The specific activity of the beta decay of $^{39}$Ar in atmospheric argon is measured using the DEAP-3600 detector. DEAP-3600, located 2 km underground at SNOLAB, uses a total of (3269 $\pm$ 24) kg of liquid argon distilled from the atmosphere to search for dark matter. This detector with very low background uses pulseshape discrimination to differentiate between nuclear recoils and electron recoi…
▽ More
The specific activity of the beta decay of $^{39}$Ar in atmospheric argon is measured using the DEAP-3600 detector. DEAP-3600, located 2 km underground at SNOLAB, uses a total of (3269 $\pm$ 24) kg of liquid argon distilled from the atmosphere to search for dark matter. This detector with very low background uses pulseshape discrimination to differentiate between nuclear recoils and electron recoils and is well-suited to measure the decay of $^{39}$Ar. With 167 live-days of data, the measured specific activity at the time of atmospheric extraction is [0.964 $\pm$ 0.001 (stat) $\pm$ 0.024 (sys)] Bq/kg$_{\rm atmAr}$ which is consistent with results from other experiments. A cross-check analysis using different event selection criteria provides a consistent result.
△ Less
Submitted 10 October, 2023; v1 submitted 27 February, 2023;
originally announced February 2023.
-
Mineral Detection of Neutrinos and Dark Matter. A Whitepaper
Authors:
Sebastian Baum,
Patrick Stengel,
Natsue Abe,
Javier F. Acevedo,
Gabriela R. Araujo,
Yoshihiro Asahara,
Frank Avignone,
Levente Balogh,
Laura Baudis,
Yilda Boukhtouchen,
Joseph Bramante,
Pieter Alexander Breur,
Lorenzo Caccianiga,
Francesco Capozzi,
Juan I. Collar,
Reza Ebadi,
Thomas Edwards,
Klaus Eitel,
Alexey Elykov,
Rodney C. Ewing,
Katherine Freese,
Audrey Fung,
Claudio Galelli,
Ulrich A. Glasmacher,
Arianna Gleason
, et al. (44 additional authors not shown)
Abstract:
Minerals are solid state nuclear track detectors - nuclear recoils in a mineral leave latent damage to the crystal structure. Depending on the mineral and its temperature, the damage features are retained in the material from minutes (in low-melting point materials such as salts at a few hundred degrees C) to timescales much larger than the 4.5 Gyr-age of the Solar System (in refractory materials…
▽ More
Minerals are solid state nuclear track detectors - nuclear recoils in a mineral leave latent damage to the crystal structure. Depending on the mineral and its temperature, the damage features are retained in the material from minutes (in low-melting point materials such as salts at a few hundred degrees C) to timescales much larger than the 4.5 Gyr-age of the Solar System (in refractory materials at room temperature). The damage features from the $O(50)$ MeV fission fragments left by spontaneous fission of $^{238}$U and other heavy unstable isotopes have long been used for fission track dating of geological samples. Laboratory studies have demonstrated the readout of defects caused by nuclear recoils with energies as small as $O(1)$ keV. This whitepaper discusses a wide range of possible applications of minerals as detectors for $E_R \gtrsim O(1)$ keV nuclear recoils: Using natural minerals, one could use the damage features accumulated over $O(10)$ Myr$-O(1)$ Gyr to measure astrophysical neutrino fluxes (from the Sun, supernovae, or cosmic rays interacting with the atmosphere) as well as search for Dark Matter. Using signals accumulated over months to few-years timescales in laboratory-manufactured minerals, one could measure reactor neutrinos or use them as Dark Matter detectors, potentially with directional sensitivity. Research groups in Europe, Asia, and America have started develo** microscopy techniques to read out the $O(1) - O(100)$ nm damage features in crystals left by $O(0.1) - O(100)$ keV nuclear recoils. We report on the status and plans of these programs. The research program towards the realization of such detectors is highly interdisciplinary, combining geoscience, material science, applied and fundamental physics with techniques from quantum information and Artificial Intelligence.
△ Less
Submitted 16 May, 2023; v1 submitted 17 January, 2023;
originally announced January 2023.
-
Liquid argon light collection and veto modeling in GERDA Phase II
Authors:
GERDA collaboration,
M. Agostini,
A. Alexander,
G. R. Araujo,
A. M. Bakalyarov,
M. Balata,
I. Barabanov,
L. Baudis,
C. Bauer,
S. Belogurov,
A. Bettini,
L. Bezrukov,
V. Biancacci,
E. Bossio,
V. Bothe,
R. Brugnera,
A. Caldwell,
S. Calgaro,
C. Cattadori,
A. Chernogorov,
P-J. Chiu,
T. Comellato,
V. D'Andrea,
E. V. Demidova,
A. Di Giacinto
, et al. (94 additional authors not shown)
Abstract:
The ability to detect liquid argon scintillation light from within a densely packed high-purity germanium detector array allowed the GERDA experiment to reach an exceptionally low background rate in the search for neutrinoless double beta decay of $^{76}$Ge. Proper modeling of the light propagation throughout the experimental setup, from any origin in the liquid argon volume to its eventual detect…
▽ More
The ability to detect liquid argon scintillation light from within a densely packed high-purity germanium detector array allowed the GERDA experiment to reach an exceptionally low background rate in the search for neutrinoless double beta decay of $^{76}$Ge. Proper modeling of the light propagation throughout the experimental setup, from any origin in the liquid argon volume to its eventual detection by the novel light read-out system, provides insight into the rejection capability and is a necessary ingredient to obtain robust background predictions. In this paper, we present a model of the GERDA liquid argon veto, as obtained by Monte Carlo simulations and constrained by calibration data, and highlight its application for background decomposition.
△ Less
Submitted 6 December, 2022;
originally announced December 2022.
-
Passive low energy nuclear recoil detection with color centers -- PALEOCCENE
Authors:
Krystal Alfonso,
Gabriela R. Araujo,
Laura Baudis,
Nathaniel Bowden,
Bernadette K. Cogswell,
Anna Erickson,
Michelle Galloway,
Adam A. Hecht,
Rathsara R. H. Herath Mudiyanselage,
Patrick Huber,
Igor Jovanovic,
Giti A. Khodaparast,
Brenden A. Magill,
Thomas O'Donnell,
Nicholas W. G. Smith,
Xianyi Zhang
Abstract:
The PALEOCCENE concept offers the potential for room-temperature, passive and robust detectors in the gram to kilogram range for the detection of low-energy nuclear recoil events. Nuclear recoil events can be caused by neutron scattering, coherent elastic neutrino nucleus scattering (CEvNS) or dark matter scattering and therefore, PALEOCCENE could find applications in all three areas. In this whit…
▽ More
The PALEOCCENE concept offers the potential for room-temperature, passive and robust detectors in the gram to kilogram range for the detection of low-energy nuclear recoil events. Nuclear recoil events can be caused by neutron scattering, coherent elastic neutrino nucleus scattering (CEvNS) or dark matter scattering and therefore, PALEOCCENE could find applications in all three areas. In this white paper we present current and planned R&D efforts to study the feasibility of this technique.
△ Less
Submitted 10 March, 2022;
originally announced March 2022.
-
R&D of Wavelength-Shifting Reflectors and Characterization of the Quantum Efficiency of Tetraphenyl Butadiene and Polyethylene Naphthalate in Liquid Argon
Authors:
G. R. Araujo,
L. Baudis,
N. McFadden,
P. Krause,
S. Schönert,
V. H. S. Wu
Abstract:
Detectors based on liquid argon (LAr) often require surfaces that can shift vacuum ultraviolet (VUV) light and reflect the visible shifted light. For the LAr instrumentation of the LEGEND-200 neutrinoless double beta decay experiment, several square meters of wavelength-shifting reflectors (WLSR) were prepared: the reflector Tetratex (TTX) was in-situ evaporated with the wavelength shifter tetraph…
▽ More
Detectors based on liquid argon (LAr) often require surfaces that can shift vacuum ultraviolet (VUV) light and reflect the visible shifted light. For the LAr instrumentation of the LEGEND-200 neutrinoless double beta decay experiment, several square meters of wavelength-shifting reflectors (WLSR) were prepared: the reflector Tetratex (TTX) was in-situ evaporated with the wavelength shifter tetraphenyl butadiene (TPB). For even larger detectors, TPB evaporation will be more challenging and plastic films of polyethylene naphthalate (PEN) are considered as an option to ease scalability.
In this work, we first characterized the absorption (and reflectivity) of PEN, TPB (and TTX) films in response to visible light. We then measured TPB and PEN coupled to TTX in a LAr setup equipped with a VUV sensitive photomultiplier tube. The effective light yield in the setup was first measured using an absorbing reference sample, and the VUV reflectivity of TTX quantified. The characterization and simulation of the setup along with the measurements and modelling of the optical parameters of TPB, PEN and TTX allowed to estimate the quantum efficiency (QE) of TPB and PEN in LAr (at 87K) for the first time: these were found to be above 67% and 49%, respectively (at 90% CL). These results provide relevant input for the optical simulations of experiments that use TPB in LAr, such as LEGEND-200, and for experiments that plan to use TPB or PEN to shift VUV scintillation light.
△ Less
Submitted 14 May, 2022; v1 submitted 13 December, 2021;
originally announced December 2021.
-
Final Results of GERDA on the Search for Neutrinoless Double-$β$ Decay
Authors:
GERDA collaboration,
M. Agostini,
G. R. Araujo,
A. M. Bakalyarov,
M. Balata,
I. Barabanov,
L. Baudis,
C. Bauer,
E. Bellotti,
S. Belogurov,
A. Bettini,
L. Bezrukov,
V. Biancacci,
D. Borowicz,
E. Bossio,
V. Bothe,
V. Brudanin,
R. Brugnera,
A. Caldwell,
C. Cattadori,
A. Chernogorov,
T. Comellato,
V. D'Andrea,
E. V. Demidova,
N. Di Marco
, et al. (90 additional authors not shown)
Abstract:
The GERmanium Detector Array (GERDA) experiment searched for the lepton-number-violating neutrinoless double-$β$ ($0νββ$) decay of $^{76}$Ge, whose discovery would have far-reaching implications in cosmology and particle physics. By operating bare germanium diodes, enriched in $^{76}$Ge, in an active liquid argon shield, GERDA achieved an unprecedently low background index of $5.2\times10^{-4}$ co…
▽ More
The GERmanium Detector Array (GERDA) experiment searched for the lepton-number-violating neutrinoless double-$β$ ($0νββ$) decay of $^{76}$Ge, whose discovery would have far-reaching implications in cosmology and particle physics. By operating bare germanium diodes, enriched in $^{76}$Ge, in an active liquid argon shield, GERDA achieved an unprecedently low background index of $5.2\times10^{-4}$ counts/(keV$\cdot$kg$\cdot$yr) in the signal region and met the design goal to collect an exposure of 100 kg$\cdot$yr in a background-free regime. When combined with the result of Phase I, no signal is observed after 127.2 kg$\cdot$yr of total exposure. A limit on the half-life of $0νββ$ decay in $^{76}$Ge is set at $T_{1/2}>1.8\times10^{26}$ yr at 90% C.L., which coincides with the sensitivity assuming no signal.
△ Less
Submitted 13 September, 2020;
originally announced September 2020.
-
Search for dark matter with a 231-day exposure of liquid argon using DEAP-3600 at SNOLAB
Authors:
R. Ajaj,
P. -A. Amaudruz,
G. R. Araujo,
M. Baldwin,
M. Batygov,
B. Beltran,
C. E. Bina,
J. Bonatt,
M. G. Boulay,
B. Broerman,
J. F. Bueno,
P. M. Burghardt,
A. Butcher,
B. Cai,
S. Cavuoti,
M. Chen,
Y. Chen,
B. T. Cleveland,
D. Cranshaw,
K. Dering,
J. DiGioseffo,
L. Doria,
F. A. Duncan,
M. Dunford,
A. Erlandson
, et al. (77 additional authors not shown)
Abstract:
DEAP-3600 is a single-phase liquid argon (LAr) direct-detection dark matter experiment, operating 2 km underground at SNOLAB (Sudbury, Canada). The detector consists of 3279 kg of LAr contained in a spherical acrylic vessel. This paper reports on the analysis of a 758 tonne\cdot day exposure taken over a period of 231 live-days during the first year of operation. No candidate signal events are obs…
▽ More
DEAP-3600 is a single-phase liquid argon (LAr) direct-detection dark matter experiment, operating 2 km underground at SNOLAB (Sudbury, Canada). The detector consists of 3279 kg of LAr contained in a spherical acrylic vessel. This paper reports on the analysis of a 758 tonne\cdot day exposure taken over a period of 231 live-days during the first year of operation. No candidate signal events are observed in the WIMP-search region of interest, which results in the leading limit on the WIMP-nucleon spin-independent cross section on a LAr target of $3.9\times10^{-45}$ cm$^{2}$ ($1.5\times10^{-44}$ cm$^{2}$) for a 100 GeV/c$^{2}$ (1 TeV/c$^{2}$) WIMP mass at 90\% C. L. In addition to a detailed background model, this analysis demonstrates the best pulse-shape discrimination in LAr at threshold, employs a Bayesian photoelectron-counting technique to improve the energy resolution and discrimination efficiency, and utilizes two position reconstruction algorithms based on PMT charge and photon arrival times.
△ Less
Submitted 4 July, 2019; v1 submitted 11 February, 2019;
originally announced February 2019.
-
Polyethylene naphthalate film as a wavelength shifter in liquid argon detectors
Authors:
M. Kuźniak,
B. Broerman,
T. Pollmann,
G. R. Araujo
Abstract:
Liquid argon-based scintillation detectors are important for dark matter searches and neutrino physics. Argon scintillation light is in the vacuum ultraviolet region, making it hard to be detected by conventional means. Polyethylene naphthalate (PEN), an optically transparent thermoplastic polyester commercially available as large area sheets or rolls, is proposed as an alternative wavelength shif…
▽ More
Liquid argon-based scintillation detectors are important for dark matter searches and neutrino physics. Argon scintillation light is in the vacuum ultraviolet region, making it hard to be detected by conventional means. Polyethylene naphthalate (PEN), an optically transparent thermoplastic polyester commercially available as large area sheets or rolls, is proposed as an alternative wavelength shifter to the commonly-used tetraphenyl butadiene (TPB). By combining the existing literature data and spectrometer measurements relative to TPB, we conclude that the fluorescence yield and timing of both materials may be very close. The evidence collected suggests that PEN is a suitable replacement for TPB in liquid argon neutrino detectors, and is also a promising candidate for dark matter detectors. Advantages of PEN are discussed in the context of scaling-up existing technologies to the next generation of very large ktonne-scale detectors. Its simplicity has a potential to facilitate such scale-ups, revolutionizing the field.
△ Less
Submitted 15 March, 2019; v1 submitted 11 June, 2018;
originally announced June 2018.