Using graph neural networks to reconstruct charged pion showers in the CMS High Granularity Calorimeter
Authors:
M. Aamir,
B. Acar,
G. Adamov,
T. Adams,
C. Adloff,
S. Afanasiev,
C. Agrawal,
C. Agrawal,
A. Ahmad,
H. A. Ahmed,
S. Akbar,
N. Akchurin,
B. Akgul,
B. Akgun,
R. O. Akpinar,
E. Aktas,
A. AlKadhim,
V. Alexakhin,
J. Alimena,
J. Alison,
A. Alpana,
W. Alshehri,
P. Alvarez Dominguez,
M. Alyari,
C. Amendola
, et al. (550 additional authors not shown)
Abstract:
A novel method to reconstruct the energy of hadronic showers in the CMS High Granularity Calorimeter (HGCAL) is presented. The HGCAL is a sampling calorimeter with very fine transverse and longitudinal granularity. The active media are silicon sensors and scintillator tiles readout by SiPMs and the absorbers are a combination of lead and Cu/CuW in the electromagnetic section, and steel in the hadr…
▽ More
A novel method to reconstruct the energy of hadronic showers in the CMS High Granularity Calorimeter (HGCAL) is presented. The HGCAL is a sampling calorimeter with very fine transverse and longitudinal granularity. The active media are silicon sensors and scintillator tiles readout by SiPMs and the absorbers are a combination of lead and Cu/CuW in the electromagnetic section, and steel in the hadronic section. The shower reconstruction method is based on graph neural networks and it makes use of a dynamic reduction network architecture. It is shown that the algorithm is able to capture and mitigate the main effects that normally hinder the reconstruction of hadronic showers using classical reconstruction methods, by compensating for fluctuations in the multiplicity, energy, and spatial distributions of the shower's constituents. The performance of the algorithm is evaluated using test beam data collected in 2018 prototype of the CMS HGCAL accompanied by a section of the CALICE AHCAL prototype. The capability of the method to mitigate the impact of energy leakage from the calorimeter is also demonstrated.
△ Less
Submitted 30 June, 2024; v1 submitted 17 June, 2024;
originally announced June 2024.
Effects of oxygen on the optical properties of phenyl-based scintillators during irradiation and recovery
Authors:
C. Papageorgakis,
M. Y. Aamir,
A. Belloni,
T. K. Edberg,
S. C. Eno,
B. Kronheim,
C. Palmer
Abstract:
Plastic scintillators are a versatile and inexpensive option for particle detection, which is why the largest particle physics experiments, CMS and ATLAS, use them extensively in their calorimeters. One of their challenging aspects, however, is their relatively low radiation hardness, which might be inadequate for very high luminosity future projects like the FCC-hh. In this study, results on the…
▽ More
Plastic scintillators are a versatile and inexpensive option for particle detection, which is why the largest particle physics experiments, CMS and ATLAS, use them extensively in their calorimeters. One of their challenging aspects, however, is their relatively low radiation hardness, which might be inadequate for very high luminosity future projects like the FCC-hh. In this study, results on the effects of ionizing radiation on the optical properties of plastic scintillator samples are presented. The samples are made from two different matrix materials, polystyrene and polyvinyltoluene, and have been irradiated at dose rates ranging from $2.2\,$Gy/h up to $3.4\,$kGy/h at room temperature. An internal boundary that separates two regions of different indices of refraction is visible in the samples depending on the dose rate, and it is compatible with the expected oxygen penetration depth during irradiation. The dose rate dependence of the oxygen penetration depth for the two matrix materials suggests that the oxygen penetration coefficient differs for PS and PVT. The values of the refractive index for the internal regions are elevated compared to those of the outer regions, which are compatible with the indices of unirradiated samples.
△ Less
Submitted 8 December, 2023; v1 submitted 23 October, 2023;
originally announced October 2023.