Skip to main content

Showing 1–3 of 3 results for author: van der Heide, O

Searching in archive eess. Search in all archives.
.
  1. arXiv:2403.15379  [pdf

    physics.med-ph eess.IV

    Time-efficient, high-resolution 3T whole-brain relaxometry using Cartesian 3D MR-STAT with CSF suppression

    Authors: Hongyan Liu, Edwin Versteeg, Miha Fuderer, Oscar van der Heide, Martin B. Schilder, Cornelis A. T. van den Berg, Alessandro Sbrizzi

    Abstract: Purpose: Current 3D Magnetic Resonance Spin TomogrAphy in Time-domain (MR-STAT) protocols use transient-state, gradient-spoiled gradient-echo sequences that are prone to cerebrospinal fluid (CSF) pulsation artifacts when applied to the brain. This study aims at develo** a 3D MR-STAT protocol for whole-brain relaxometry that overcomes the challenges posed by CSF-induced ghosting artifacts. Method… ▽ More

    Submitted 22 March, 2024; originally announced March 2024.

  2. arXiv:2205.02335  [pdf

    physics.med-ph eess.IV

    Acceleration Strategies for MR-STAT: Achieving High-Resolution Reconstructions on a Desktop PC within 3 minutes

    Authors: Hongyan Liu, Oscar van der Heide, Stefano Mandija, Cornelis A. T. van den Berg, Alessandro Sbrizzi

    Abstract: MR-STAT is an emerging quantitative magnetic resonance imaging technique which aims at obtaining multi-parametric tissue parameter maps from single short scans. It describes the relationship between the spatial-domain tissue parameters and the time-domain measured signal by using a comprehensive, volumetric forward model. The MR-STAT reconstruction solves a large-scale nonlinear problem, thus is v… ▽ More

    Submitted 4 May, 2022; originally announced May 2022.

    Comments: 12 pages, 7 figures, accepted by IEEE Transactions on Medical Imaging (in press)

  3. arXiv:2008.07440  [pdf

    eess.IV physics.med-ph

    Fast and Accurate Modeling of Transient-State Gradient-Spoiled Sequences by Recurrent Neural Networks

    Authors: Hongyan Liu, Oscar van der Heide, Cornelis A. T. van den Berg, Alessandro Sbrizzi

    Abstract: Fast and accurate modeling of MR signal responses are typically required for various quantitative MRI applications, such as MR Fingerprinting and MR-STAT. This work uses a new EPG-Bloch model for accurate simulation of transient-state gradient-spoiled MR sequences, and proposes a Recurrent Neural Network (RNN) as a fast surrogate of the EPG-Bloch model for computing large-scale MR signals and deri… ▽ More

    Submitted 21 August, 2020; v1 submitted 17 August, 2020; originally announced August 2020.

    Comments: Correct for typo errors