CBCT-to-CT synthesis with a single neural network for head-and-neck, lung and breast cancer adaptive radiotherapy
Authors:
Matteo Maspero,
Mark HF Savenije,
Tristan CF van Heijst,
Joost JC Verhoeff,
Alexis NTJ Kotte,
Anette C Houweling,
Cornelis AT van den Berg
Abstract:
Purpose: CBCT-based adaptive radiotherapy requires daily images for accurate dose calculations. This study investigates the feasibility of applying a single convolutional network to facilitate CBCT-to-CT synthesis for head-and-neck, lung, and breast cancer patients. Methods: Ninety-nine patients diagnosed with head-and-neck, lung or breast cancer undergoing radiotherapy with CBCT-based position ve…
▽ More
Purpose: CBCT-based adaptive radiotherapy requires daily images for accurate dose calculations. This study investigates the feasibility of applying a single convolutional network to facilitate CBCT-to-CT synthesis for head-and-neck, lung, and breast cancer patients. Methods: Ninety-nine patients diagnosed with head-and-neck, lung or breast cancer undergoing radiotherapy with CBCT-based position verification were included in this study. CBCTs were registered to planning CTs according to clinical procedures. Three cycle-consistent generative adversarial networks (cycle-GANs) were trained in an unpaired manner on 15 patients per anatomical site generating synthetic-CTs (sCTs). Another network was trained with all the anatomical sites together. Performances of all four networks were compared and evaluated for image similarity against rescan CT (rCT). Clinical plans were recalculated on CT and sCT and analysed through voxel-based dose differences and γ-analysis. Results: A sCT was generated in 10 seconds. Image similarity was comparable between models trained on different anatomical sites and a single model for all sites. Mean dose differences < 0.5% were obtained in high-dose regions. Mean gamma (2%,2mm) pass-rates > 95% were achieved for all sites. Conclusions: Cycle-GAN reduced CBCT artefacts and increased HU similarity to CT, enabling sCT-based dose calculations. The speed of the network can facilitate on-line adaptive radiotherapy using a single network for head-and-neck, lung and breast cancer patients.
△ Less
Submitted 23 December, 2019;
originally announced December 2019.
Automatic Online Quality Control of Synthetic CTs
Authors:
Louis D. van Harten,
Jelmer M. Wolterink,
Joost J. C. Verhoeff,
Ivana Išgum
Abstract:
Accurate MR-to-CT synthesis is a requirement for MR-only workflows in radiotherapy (RT) treatment planning. In recent years, deep learning-based approaches have shown impressive results in this field. However, to prevent downstream errors in RT treatment planning, it is important that deep learning models are only applied to data for which they are trained and that generated synthetic CT (sCT) ima…
▽ More
Accurate MR-to-CT synthesis is a requirement for MR-only workflows in radiotherapy (RT) treatment planning. In recent years, deep learning-based approaches have shown impressive results in this field. However, to prevent downstream errors in RT treatment planning, it is important that deep learning models are only applied to data for which they are trained and that generated synthetic CT (sCT) images do not contain severe errors. For this, a mechanism for online quality control should be in place. In this work, we use an ensemble of sCT generators and assess their disagreement as a measure of uncertainty of the results. We show that this uncertainty measure can be used for two kinds of online quality control. First, to detect input images that are outside the expected distribution of MR images. Second, to identify sCT images that were generated from suitable MR images but potentially contain errors. Such automatic online quality control for sCT generation is likely to become an integral part of MR-only RT workflows.
△ Less
Submitted 12 November, 2019;
originally announced November 2019.