-
A SOCP-based ACOPF for Operational Scheduling of Three-phase Unbalanced Distribution Systems and Coordination of PV Smart Inverters
Authors:
Mingyue He,
Zahra Soltani,
Mohammad Ghaljehei,
Masoud Esmaili,
Shanshan Ma,
Mengxi Chen,
Mojdeh Khorsand,
Raja Ayyanar,
Vijay Vittal
Abstract:
The proliferation of distributed energy resources (DERs) im-poses new challenges to distribution system operation, e.g., power quality issues. To overcome these challenges and enhance system operation, it is critical to effectively utilize all available resources and accurately characterize unbalanced distribution networks in operational tools. This paper proposes a convex second-order-cone progra…
▽ More
The proliferation of distributed energy resources (DERs) im-poses new challenges to distribution system operation, e.g., power quality issues. To overcome these challenges and enhance system operation, it is critical to effectively utilize all available resources and accurately characterize unbalanced distribution networks in operational tools. This paper proposes a convex second-order-cone programming (SOCP)-based AC optimal power flow (ACOPF) model for three-phase unbalanced distribution net-works, including smart inverters and Volt-VAr controller (VVC) devices. Reactive power-voltage (Q-V) characteristics of smart inverters of solar photovoltaic (PV) units are also modeled. More-over, the settings of Q-V characteristics of VVC are co-optimized within the proposed ACOPF, considering the allowable range of the IEEE 1547-2018 standard. Furthermore, dynamic analyses are conducted to verify the stability of optimal settings of VVC. The proposed models are tested on an actual 1747-node primary distribution feeder in Arizona. The results illustrate the effective-ness of the proposed ACOPF for unbalanced systems in provid-ing a global optimal solution while capturing the non-linearity and non-convexity of ACOPF. By co-optimizing settings, system operation is improved due to the flexibility of adjusting reactive power output from PV units with VVC. The time-domain simu-lations show that the optimal settings result in a stable system
△ Less
Submitted 12 September, 2022;
originally announced September 2022.
-
Optimal Placement of PV Smart Inverters with Volt-VAr Control in Electric Distribution Systems
Authors:
Mengxi Chen,
Shanshan Ma,
Zahra Soltani,
Raja Ayyanar,
Vijay Vittal,
Mojdeh Khorsand
Abstract:
The high R/X ratio of typical distribution systems makes the system voltage vulnerable to the active power injection from distributed energy resources (DERs). Moreover, the intermittent and uncertain nature of the DER generation brings new challenges to the voltage control. This paper proposes a two-stage stochastic optimization strategy to optimally place the PV smart inverters with Volt-VAr capa…
▽ More
The high R/X ratio of typical distribution systems makes the system voltage vulnerable to the active power injection from distributed energy resources (DERs). Moreover, the intermittent and uncertain nature of the DER generation brings new challenges to the voltage control. This paper proposes a two-stage stochastic optimization strategy to optimally place the PV smart inverters with Volt-VAr capability for distribution systems with high photovoltaic (PV) penetration to mitigate voltage violation issues. The proposed optimization strategy enables a planningstage guide for upgrading the existing PV inverters to smart inverters with Volt-VAr capability while considering the operationstage characteristics of the Volt-VAr control. One advantage of this planning strategy is that it utilizes the local control capability of the smart inverter that requires no communication, thus avoiding issues related to communication delays and failures. Another advantage is that the Volt-VAr control characteristic is internally integrated into the optimization model as a set of constraints, making placement decisions more accurate. The objective of the optimization is to minimize the upgrading cost and the number of the smart inverters required while maintaining the voltage profile within the acceptable range. Case studies on an actual 12.47kV, 9km long Arizona utility feeder have been conducted using OpenDSS to validate the effectiveness of the proposed placement strategy in both static and dynamic simulations. Index Terms
△ Less
Submitted 1 July, 2022;
originally announced July 2022.
-
Detailed Primary and Secondary Distribution System Model Enhancement Using AMI Data
Authors:
Karen Montano-Martinez,
Sushrut Thakar,
Shanshan Ma,
Zahra Soltani,
Vijay Vittal,
Mojdeh Khorsand,
Raja Ayyanar,
Cynthia Rojas
Abstract:
Reliable and accurate distribution system modeling, including the secondary network, is essential in examining distribution system performance with high penetration of distributed energy resources (DERs). This paper presents a highly automated, novel method to enhance the accuracy of utility distribution feeder models to capture their performance by matching simulation results with corresponding f…
▽ More
Reliable and accurate distribution system modeling, including the secondary network, is essential in examining distribution system performance with high penetration of distributed energy resources (DERs). This paper presents a highly automated, novel method to enhance the accuracy of utility distribution feeder models to capture their performance by matching simulation results with corresponding field measurements. The method is demonstrated using an actual feeder from an electrical utility with high penetration of DERs. The method proposed uses advanced metering infrastructure (AMI) voltage and derived active power measurements at the customer level, and data acquisition systems (DAS) measurements at the feeder-head, in conjunction with an AC optimal power flow (ACOPF) to estimate customer active and reactive power consumption over a time horizon, while accounting for unmetered loads. Additionally, the method proposed estimates both voltage magnitude and angle for each phase at the unbalanced distribution substation. Furthermore, the accuracy of the method developed is verified by comparing the time-series power flow results obtained from the enhancement algorithm with OpenDSS results. The proposed approach seamlessly manages the data available from the optimization procedure through the final model verification automatically.
△ Less
Submitted 28 May, 2021;
originally announced May 2021.
-
Stochastic AC Network-constrained Scheduling of CAES and Wind Power Generation in Joint Energy and reserve market: Toward More Realistic Results
Authors:
Mohammad Ghaljehei,
Mahrad Rahimi,
Zahra Soltani,
Behrouz Azimian,
Behzad Vatandoust,
Masoud Aliakbar Golkar
Abstract:
In this paper, a two-stage stochastic day-ahead (DA) scheduling model is proposed incorporating wind power units and compressed air energy storage (CAES) to clear a co-optimized energy and reserve market. The two-stage stochastic programming method is employed to deal with the wind power generation uncertain nature. A linearized AC optimal power flow (LAC-OPF) approach with consideration of networ…
▽ More
In this paper, a two-stage stochastic day-ahead (DA) scheduling model is proposed incorporating wind power units and compressed air energy storage (CAES) to clear a co-optimized energy and reserve market. The two-stage stochastic programming method is employed to deal with the wind power generation uncertain nature. A linearized AC optimal power flow (LAC-OPF) approach with consideration of network losses, reactive power, and voltage magnitude constraints is utilized in the proposed two-stage stochastic DA scheduling model. Using an engineering insight, a two-level LAC-OPF (TL-LAC-OPF) approach is proposed to (i) reduce the number of binary variables of the LAC-OPF approach which decreases the computational burden, and (ii) obtain LAC-OPF pre-defined parameters adaptively so that the accuracy of LAC-OPF approach is increased as a result of reducing artificial losses. Furthermore, as the CAES efficiency depends on its thermodynamic and operational conditions, the proposed two-stage stochastic DA scheduling model is developed by considering its thermodynamic characteristics to obtain a more realistic market decision at the first place. The proposed model is applied to IEEE 30-bus and 57-bus test systems using GAMS software, and is compared with three traditional approaches, i.e., AC-OPF, DC-OPF, and LAC-OPF. Simulation results demonstrate effectiveness of the proposed methodology.
△ Less
Submitted 21 February, 2021;
originally announced February 2021.
-
Two-Stage Distributed Energy Resources Scheduling via Chance-Constrained AC Optimal Power Flow: A Second-Order Cone Programming Approach
Authors:
Mingyue He,
Zahra Soltani,
Mojdeh Khorsand
Abstract:
The penetration of distributed energy resources (DERs) is increasing dramatically. Due to the uncertainty of DERs, the operation of the distribution system is facing higher risks and challenges. To overcome such challenges, a two-stage chance-constrained convex AC optimal power flow (ACOPF) model is proposed in this paper, which can increase the economic efficiency of distribution system operation…
▽ More
The penetration of distributed energy resources (DERs) is increasing dramatically. Due to the uncertainty of DERs, the operation of the distribution system is facing higher risks and challenges. To overcome such challenges, a two-stage chance-constrained convex AC optimal power flow (ACOPF) model is proposed in this paper, which can increase the economic efficiency of distribution system operation and manage the intermittency of DERs. In the first stage, a convex second-order cone programming (SOCP)-based ACOPF model is proposed in which the detailed models and limitations of DER, namely, demand response (DR), energy storage units, and rooftop PV systems are modeled to obtain participation ratio of DERs. In the second stage, Monte Carlo simulation is utilized to model the uncertainties of DERs. A probability violation index is introduced to make a trade-off between scheduling more DERs and imposing a higher risk to the distribution system. In this stage, power flow analysis is conducted for each scenario to determine the probability violation index of system. Then, a modified SOCP-based ACOPF is proposed to satisfy the system probability violation criterion. Simulation results illustrate that the proposed two-stage chance-constrained model improves economic efficiency and reliability of real-time operation of the distribution system.
△ Less
Submitted 6 May, 2020;
originally announced May 2020.