-
DeepEMC-T2 Map**: Deep Learning-Enabled T2 Map** Based on Echo Modulation Curve Modeling
Authors:
Haoyang Pei,
Timothy M. Shepherd,
Yao Wang,
Fang Liu,
Daniel K Sodickson,
Noam Ben-Eliezer,
Li Feng
Abstract:
Purpose: Echo modulation curve (EMC) modeling can provide accurate and reproducible quantification of T2 relaxation times. The standard EMC-T2 map** framework, however, requires sufficient echoes and cumbersome pixel-wise dictionary-matching steps. This work proposes a deep learning version of EMC-T2 map**, called DeepEMC-T2 map**, to efficiently estimate accurate T2 maps from fewer echoes w…
▽ More
Purpose: Echo modulation curve (EMC) modeling can provide accurate and reproducible quantification of T2 relaxation times. The standard EMC-T2 map** framework, however, requires sufficient echoes and cumbersome pixel-wise dictionary-matching steps. This work proposes a deep learning version of EMC-T2 map**, called DeepEMC-T2 map**, to efficiently estimate accurate T2 maps from fewer echoes without a dictionary.
Methods: DeepEMC-T2 map** was developed using a modified U-Net to estimate both T2 and Proton Density (PD) maps directly from multi-echo spin-echo (MESE) images. The modified U-Net employs several new features to improve the accuracy of T2/PD estimation. MESE datasets from 68 subjects were used for training and evaluation of the DeepEMC-T2 map** technique. Multiple experiments were conducted to evaluate the impact of the proposed new features on DeepEMC-T2 map**.
Results: DeepEMC-T2 map** achieved T2 estimation errors ranging from 3%-12% in different T2 ranges and 0.8%-1.7% for PD estimation with 10/7/5/3 echoes, which yielded more accurate parameter estimation than standard EMC-T2 map**. The new features proposed in DeepEMC-T2 map** enabled improved parameter estimation. The use of a larger echo spacing with fewer echoes can maintain the accuracy of T2 and PD estimations while reducing the number of 180-degree refocusing pulses.
Conclusions: DeepEMC-T2 map** enables simplified, efficient, and accurate T2 quantification directly from MESE images without a time-consuming dictionary-matching step and requires fewer echoes. This allows for increased volumetric coverage and/or decreased SAR by reducing the number of 180-degree refocusing pulses.
△ Less
Submitted 29 February, 2024;
originally announced February 2024.
-
On Sensitivity and Robustness of Normalization Schemes to Input Distribution Shifts in Automatic MR Image Diagnosis
Authors:
Divyam Madaan,
Daniel Sodickson,
Kyunghyun Cho,
Sumit Chopra
Abstract:
Magnetic Resonance Imaging (MRI) is considered the gold standard of medical imaging because of the excellent soft-tissue contrast exhibited in the images reconstructed by the MRI pipeline, which in-turn enables the human radiologist to discern many pathologies easily. More recently, Deep Learning (DL) models have also achieved state-of-the-art performance in diagnosing multiple diseases using thes…
▽ More
Magnetic Resonance Imaging (MRI) is considered the gold standard of medical imaging because of the excellent soft-tissue contrast exhibited in the images reconstructed by the MRI pipeline, which in-turn enables the human radiologist to discern many pathologies easily. More recently, Deep Learning (DL) models have also achieved state-of-the-art performance in diagnosing multiple diseases using these reconstructed images as input. However, the image reconstruction process within the MRI pipeline, which requires the use of complex hardware and adjustment of a large number of scanner parameters, is highly susceptible to noise of various forms, resulting in arbitrary artifacts within the images. Furthermore, the noise distribution is not stationary and varies within a machine, across machines, and patients, leading to varying artifacts within the images. Unfortunately, DL models are quite sensitive to these varying artifacts as it leads to changes in the input data distribution between the training and testing phases. The lack of robustness of these models against varying artifacts impedes their use in medical applications where safety is critical. In this work, we focus on improving the generalization performance of these models in the presence of multiple varying artifacts that manifest due to the complexity of the MR data acquisition. In our experiments, we observe that Batch Normalization, a widely used technique during the training of DL models for medical image analysis, is a significant cause of performance degradation in these changing environments. As a solution, we propose to use other normalization techniques, such as Group Normalization and Layer Normalization (LN), to inject robustness into model performance against varying image artifacts. Through a systematic set of experiments, we show that GN and LN provide better accuracy for various MR artifacts and distribution shifts.
△ Less
Submitted 22 June, 2023;
originally announced June 2023.
-
FastMRI Prostate: A Publicly Available, Biparametric MRI Dataset to Advance Machine Learning for Prostate Cancer Imaging
Authors:
Radhika Tibrewala,
Tarun Dutt,
Angela Tong,
Luke Ginocchio,
Mahesh B Keerthivasan,
Steven H Baete,
Sumit Chopra,
Yvonne W Lui,
Daniel K Sodickson,
Hersh Chandarana,
Patricia M Johnson
Abstract:
The fastMRI brain and knee dataset has enabled significant advances in exploring reconstruction methods for improving speed and image quality for Magnetic Resonance Imaging (MRI) via novel, clinically relevant reconstruction approaches. In this study, we describe the April 2023 expansion of the fastMRI dataset to include biparametric prostate MRI data acquired on a clinical population. The dataset…
▽ More
The fastMRI brain and knee dataset has enabled significant advances in exploring reconstruction methods for improving speed and image quality for Magnetic Resonance Imaging (MRI) via novel, clinically relevant reconstruction approaches. In this study, we describe the April 2023 expansion of the fastMRI dataset to include biparametric prostate MRI data acquired on a clinical population. The dataset consists of raw k-space and reconstructed images for T2-weighted and diffusion-weighted sequences along with slice-level labels that indicate the presence and grade of prostate cancer. As has been the case with fastMRI, increasing accessibility to raw prostate MRI data will further facilitate research in MR image reconstruction and evaluation with the larger goal of improving the utility of MRI for prostate cancer detection and evaluation. The dataset is available at https://fastmri.med.nyu.edu.
△ Less
Submitted 18 April, 2023;
originally announced April 2023.
-
An Orchestration Platform that Puts Radiologists in the Driver's Seat of AI Innovation: A Methodological Approach
Authors:
Raphael Y. Cohen,
Aaron D. Sodickson
Abstract:
Current AI-driven research in radiology requires resources and expertise that are often inaccessible to small and resource-limited labs. The clinicians who are able to participate in AI research are frequently well-funded, well-staffed, and either have significant experience with AI and computing, or have access to colleagues or facilities that do. Current imaging data is clinician-oriented and is…
▽ More
Current AI-driven research in radiology requires resources and expertise that are often inaccessible to small and resource-limited labs. The clinicians who are able to participate in AI research are frequently well-funded, well-staffed, and either have significant experience with AI and computing, or have access to colleagues or facilities that do. Current imaging data is clinician-oriented and is not easily amenable to machine learning initiatives, resulting in inefficient, time consuming, and costly efforts that rely upon a crew of data engineers and machine learning scientists, and all too often preclude radiologists from driving AI research and innovation. We present the system and methodology we have developed to address infrastructure and platform needs, while reducing the staffing and resource barriers to entry. We emphasize a data-first and modular approach that streamlines the AI development and deployment process while providing efficient and familiar interfaces for radiologists, such that they can be the drivers of new AI innovations.
△ Less
Submitted 6 July, 2021;
originally announced July 2021.
-
Differences between human and machine perception in medical diagnosis
Authors:
Taro Makino,
Stanislaw Jastrzebski,
Witold Oleszkiewicz,
Celin Chacko,
Robin Ehrenpreis,
Naziya Samreen,
Chloe Chhor,
Eric Kim,
Jiyon Lee,
Kristine Pysarenko,
Beatriu Reig,
Hildegard Toth,
Divya Awal,
Linda Du,
Alice Kim,
James Park,
Daniel K. Sodickson,
Laura Heacock,
Linda Moy,
Kyunghyun Cho,
Krzysztof J. Geras
Abstract:
Deep neural networks (DNNs) show promise in image-based medical diagnosis, but cannot be fully trusted since their performance can be severely degraded by dataset shifts to which human perception remains invariant. If we can better understand the differences between human and machine perception, we can potentially characterize and mitigate this effect. We therefore propose a framework for comparin…
▽ More
Deep neural networks (DNNs) show promise in image-based medical diagnosis, but cannot be fully trusted since their performance can be severely degraded by dataset shifts to which human perception remains invariant. If we can better understand the differences between human and machine perception, we can potentially characterize and mitigate this effect. We therefore propose a framework for comparing human and machine perception in medical diagnosis. The two are compared with respect to their sensitivity to the removal of clinically meaningful information, and to the regions of an image deemed most suspicious. Drawing inspiration from the natural image domain, we frame both comparisons in terms of perturbation robustness. The novelty of our framework is that separate analyses are performed for subgroups with clinically meaningful differences. We argue that this is necessary in order to avert Simpson's paradox and draw correct conclusions. We demonstrate our framework with a case study in breast cancer screening, and reveal significant differences between radiologists and DNNs. We compare the two with respect to their robustness to Gaussian low-pass filtering, performing a subgroup analysis on microcalcifications and soft tissue lesions. For microcalcifications, DNNs use a separate set of high frequency components than radiologists, some of which lie outside the image regions considered most suspicious by radiologists. These features run the risk of being spurious, but if not, could represent potential new biomarkers. For soft tissue lesions, the divergence between radiologists and DNNs is even starker, with DNNs relying heavily on spurious high frequency components ignored by radiologists. Importantly, this deviation in soft tissue lesions was only observable through subgroup analysis, which highlights the importance of incorporating medical domain knowledge into our comparison framework.
△ Less
Submitted 27 November, 2020;
originally announced November 2020.
-
Magnetic-resonance-based electrical property map** using Global Maxwell Tomography with an 8-channel head coil at 7 Tesla: a simulation study
Authors:
Ilias I. Giannakopoulos,
José E. C. Serrallés,
Luca Daniel,
Daniel K. Sodickson,
Athanasios G. Polimeridis,
Jacob K. White,
Riccardo Lattanzi
Abstract:
Objective: Global Maxwell Tomography (GMT) is a recently introduced volumetric technique for noninvasive estimation of electrical properties (EP) from magnetic resonance measurements. Previous work evaluated GMT using ideal radiofrequency (RF) excitations. The aim of this simulation study was to assess GMT performance with a realistic RF coil. Methods: We designed a transmit-receive RF coil with…
▽ More
Objective: Global Maxwell Tomography (GMT) is a recently introduced volumetric technique for noninvasive estimation of electrical properties (EP) from magnetic resonance measurements. Previous work evaluated GMT using ideal radiofrequency (RF) excitations. The aim of this simulation study was to assess GMT performance with a realistic RF coil. Methods: We designed a transmit-receive RF coil with $8$ decoupled channels for $7$T head imaging. We calculated the RF transmit field ($B_1^+$) inside heterogeneous head models for different RF shimming approaches, and used them as input for GMT to reconstruct EP for all voxels. Results: Coil tuning/decoupling remained relatively stable when the coil was loaded with different head models. Mean error in EP estimation changed from $7.5\%$ to $9.5\%$ and from $4.8\%$ to $7.2\%$ for relative permittivity and conductivity, respectively, when changing head model without re-tuning the coil. Results slightly improved when an SVD-based RF shimming algorithm was applied, in place of excitation with one coil at a time. Despite errors in EP, RF transmit field ($B_1^+$) and absorbed power could be predicted with less than $0.5\%$ error over the entire head. GMT could accurately detect a numerically inserted tumor. Conclusion: This work demonstrates that GMT can reliably reconstruct EP in realistic simulated scenarios using a tailored 8-channel RF coil design at $7$T. Future work will focus on construction of the coil and optimization of GMT's robustness to noise, to enable in-vivo GMT experiments. Significance: GMT could provide accurate estimations of tissue EP, which could be used as biomarkers and could enable patient-specific estimation of RF power deposition, which is an unsolved problem for ultra-high-field magnetic resonance imaging.
△ Less
Submitted 20 March, 2020;
originally announced March 2020.
-
Advancing machine learning for MR image reconstruction with an open competition: Overview of the 2019 fastMRI challenge
Authors:
Florian Knoll,
Tullie Murrell,
Anuroop Sriram,
Nafissa Yakubova,
Jure Zbontar,
Michael Rabbat,
Aaron Defazio,
Matthew J. Muckley,
Daniel K. Sodickson,
C. Lawrence Zitnick,
Michael P. Recht
Abstract:
Purpose: To advance research in the field of machine learning for MR image reconstruction with an open challenge. Methods: We provided participants with a dataset of raw k-space data from 1,594 consecutive clinical exams of the knee. The goal of the challenge was to reconstruct images from these data. In order to strike a balance between realistic data and a shallow learning curve for those not al…
▽ More
Purpose: To advance research in the field of machine learning for MR image reconstruction with an open challenge. Methods: We provided participants with a dataset of raw k-space data from 1,594 consecutive clinical exams of the knee. The goal of the challenge was to reconstruct images from these data. In order to strike a balance between realistic data and a shallow learning curve for those not already familiar with MR image reconstruction, we ran multiple tracks for multi-coil and single-coil data. We performed a two-stage evaluation based on quantitative image metrics followed by evaluation by a panel of radiologists. The challenge ran from June to December of 2019. Results: We received a total of 33 challenge submissions. All participants chose to submit results from supervised machine learning approaches. Conclusion: The challenge led to new developments in machine learning for image reconstruction, provided insight into the current state of the art in the field, and highlighted remaining hurdles for clinical adoption.
△ Less
Submitted 6 January, 2020;
originally announced January 2020.
-
GrappaNet: Combining Parallel Imaging with Deep Learning for Multi-Coil MRI Reconstruction
Authors:
Anuroop Sriram,
Jure Zbontar,
Tullie Murrell,
C. Lawrence Zitnick,
Aaron Defazio,
Daniel K. Sodickson
Abstract:
Magnetic Resonance Image (MRI) acquisition is an inherently slow process which has spurred the development of two different acceleration methods: acquiring multiple correlated samples simultaneously (parallel imaging) and acquiring fewer samples than necessary for traditional signal processing methods (compressed sensing). Both methods provide complementary approaches to accelerating the speed of…
▽ More
Magnetic Resonance Image (MRI) acquisition is an inherently slow process which has spurred the development of two different acceleration methods: acquiring multiple correlated samples simultaneously (parallel imaging) and acquiring fewer samples than necessary for traditional signal processing methods (compressed sensing). Both methods provide complementary approaches to accelerating the speed of MRI acquisition. In this paper, we present a novel method to integrate traditional parallel imaging methods into deep neural networks that is able to generate high quality reconstructions even for high acceleration factors. The proposed method, called GrappaNet, performs progressive reconstruction by first map** the reconstruction problem to a simpler one that can be solved by a traditional parallel imaging methods using a neural network, followed by an application of a parallel imaging method, and finally fine-tuning the output with another neural network. The entire network can be trained end-to-end. We present experimental results on the recently released fastMRI dataset and show that GrappaNet can generate higher quality reconstructions than competing methods for both $4\times$ and $8\times$ acceleration.
△ Less
Submitted 30 March, 2020; v1 submitted 27 October, 2019;
originally announced October 2019.
-
Magnetization Transfer in Magnetic Resonance Fingerprinting
Authors:
Tom Hilbert,
Ding Xia,
Kai Tobias Block,
Zidan Yu,
Riccardo Lattanzi,
Daniel K. Sodickson,
Tobias Kober,
Martijn A. Cloos
Abstract:
Purpose: To study the effects of magnetization transfer (MT, in which a semisolid spin pool interacts with the free pool), in the context of magnetic resonance fingerprinting (MRF).
Methods: Simulations and phantom experiments were performed to study the impact of MT on the MRF signal and its potential influence on T1 and T2 estimation. Subsequently, an MRF sequence implementing off-resonance MT…
▽ More
Purpose: To study the effects of magnetization transfer (MT, in which a semisolid spin pool interacts with the free pool), in the context of magnetic resonance fingerprinting (MRF).
Methods: Simulations and phantom experiments were performed to study the impact of MT on the MRF signal and its potential influence on T1 and T2 estimation. Subsequently, an MRF sequence implementing off-resonance MT pulses and a dictionary with an MT dimension by incorporating a two-pool model were used to estimate the fractional pool size in addition to the B1+, T1, and T2 values. The proposed method was evaluated in the human brain.
Results: Simulations and phantom experiments showed that an MRF signal obtained from a cross-linked bovine serum sample is influenced by MT. Using a dictionary based on an MT model, a better match between simulations and acquired MR signals can be obtained (NRMSE 1.3% versus 4.7%). Adding off-resonance MT pulses can improve the differentiation of MT from T1 and T2. In-vivo results showed that MT affects the MRF signals from white matter (fractional pool-size ~16%) and gray matter (fractional pool-size ~10%). Furthermore, longer T1 (~1060 ms versus ~860 ms) and T2 values (~47 ms versus ~35 ms) can be observed in white matter if MT is accounted for.
Conclusion: Our experiments demonstrated a potential influence of MT on the quantification of T1 and T2 with MRF. A model that encompasses MT effects can improve the accuracy of estimated relaxation parameters and allows quantification of the fractional pool size.
△ Less
Submitted 30 July, 2019;
originally announced July 2019.
-
Training a Neural Network for Gibbs and Noise Removal in Diffusion MRI
Authors:
Matthew J. Muckley,
Benjamin Ades-Aron,
Antonios Papaioannou,
Gregory Lemberskiy,
Eddy Solomon,
Yvonne W. Lui,
Daniel K. Sodickson,
Els Fieremans,
Dmitry S. Novikov,
Florian Knoll
Abstract:
We develop and evaluate a neural network-based method for Gibbs artifact and noise removal. A convolutional neural network (CNN) was designed for artifact removal in diffusion-weighted imaging data. Two implementations were considered: one for magnitude images and one for complex images. Both models were based on the same encoder-decoder structure and were trained by simulating MRI acquisitions on…
▽ More
We develop and evaluate a neural network-based method for Gibbs artifact and noise removal. A convolutional neural network (CNN) was designed for artifact removal in diffusion-weighted imaging data. Two implementations were considered: one for magnitude images and one for complex images. Both models were based on the same encoder-decoder structure and were trained by simulating MRI acquisitions on synthetic non-MRI images. Both machine learning methods were able to mitigate artifacts in diffusion-weighted images and diffusion parameter maps. The CNN for complex images was also able to reduce artifacts in partial Fourier acquisitions. The proposed CNNs extend the ability of artifact correction in diffusion MRI. The machine learning method described here can be applied on each imaging slice independently, allowing it to be used flexibly in clinical applications.
△ Less
Submitted 15 May, 2019; v1 submitted 10 May, 2019;
originally announced May 2019.
-
Deep Learning Methods for Parallel Magnetic Resonance Image Reconstruction
Authors:
Florian Knoll,
Kerstin Hammernik,
Chi Zhang,
Steen Moeller,
Thomas Pock,
Daniel K. Sodickson,
Mehmet Akcakaya
Abstract:
Following the success of deep learning in a wide range of applications, neural network-based machine learning techniques have received interest as a means of accelerating magnetic resonance imaging (MRI). A number of ideas inspired by deep learning techniques from computer vision and image processing have been successfully applied to non-linear image reconstruction in the spirit of compressed sens…
▽ More
Following the success of deep learning in a wide range of applications, neural network-based machine learning techniques have received interest as a means of accelerating magnetic resonance imaging (MRI). A number of ideas inspired by deep learning techniques from computer vision and image processing have been successfully applied to non-linear image reconstruction in the spirit of compressed sensing for both low dose computed tomography and accelerated MRI. The additional integration of multi-coil information to recover missing k-space lines in the MRI reconstruction process, is still studied less frequently, even though it is the de-facto standard for currently used accelerated MR acquisitions. This manuscript provides an overview of the recent machine learning approaches that have been proposed specifically for improving parallel imaging. A general background introduction to parallel MRI is given that is structured around the classical view of image space and k-space based methods. Both linear and non-linear methods are covered, followed by a discussion of recent efforts to further improve parallel imaging using machine learning, and specifically using artificial neural networks. Image-domain based techniques that introduce improved regularizers are covered as well as k-space based methods, where the focus is on better interpolation strategies using neural networks. Issues and open problems are discussed as well as recent efforts for producing open datasets and benchmarks for the community.
△ Less
Submitted 1 April, 2019;
originally announced April 2019.
-
fastMRI: An Open Dataset and Benchmarks for Accelerated MRI
Authors:
Jure Zbontar,
Florian Knoll,
Anuroop Sriram,
Tullie Murrell,
Zhengnan Huang,
Matthew J. Muckley,
Aaron Defazio,
Ruben Stern,
Patricia Johnson,
Mary Bruno,
Marc Parente,
Krzysztof J. Geras,
Joe Katsnelson,
Hersh Chandarana,
Zizhao Zhang,
Michal Drozdzal,
Adriana Romero,
Michael Rabbat,
Pascal Vincent,
Nafissa Yakubova,
James Pinkerton,
Duo Wang,
Erich Owens,
C. Lawrence Zitnick,
Michael P. Recht
, et al. (2 additional authors not shown)
Abstract:
Accelerating Magnetic Resonance Imaging (MRI) by taking fewer measurements has the potential to reduce medical costs, minimize stress to patients and make MRI possible in applications where it is currently prohibitively slow or expensive. We introduce the fastMRI dataset, a large-scale collection of both raw MR measurements and clinical MR images, that can be used for training and evaluation of ma…
▽ More
Accelerating Magnetic Resonance Imaging (MRI) by taking fewer measurements has the potential to reduce medical costs, minimize stress to patients and make MRI possible in applications where it is currently prohibitively slow or expensive. We introduce the fastMRI dataset, a large-scale collection of both raw MR measurements and clinical MR images, that can be used for training and evaluation of machine-learning approaches to MR image reconstruction. By introducing standardized evaluation criteria and a freely-accessible dataset, our goal is to help the community make rapid advances in the state of the art for MR image reconstruction. We also provide a self-contained introduction to MRI for machine learning researchers with no medical imaging background.
△ Less
Submitted 11 December, 2019; v1 submitted 21 November, 2018;
originally announced November 2018.