Skip to main content

Showing 1–8 of 8 results for author: Scannell, C M

Searching in archive eess. Search in all archives.
.
  1. arXiv:2109.12940  [pdf

    eess.IV cs.CV

    Optimized Automated Cardiac MR Scar Quantification with GAN-Based Data Augmentation

    Authors: Didier R. P. R. M. Lustermans, Sina Amirrajab, Mitko Veta, Marcel Breeuwer, Cian M. Scannell

    Abstract: Background: The clinical utility of late gadolinium enhancement (LGE) cardiac MRI is limited by the lack of standardization, and time-consuming postprocessing. In this work, we tested the hypothesis that a cascaded deep learning pipeline trained with augmentation by synthetically generated data would improve model accuracy and robustness for automated scar quantification. Methods: A cascaded pip… ▽ More

    Submitted 27 September, 2021; originally announced September 2021.

    Comments: Submitted for peer review

  2. CardiSort: a convolutional neural network for cross vendor automated sorting of cardiac MR images

    Authors: Ruth P Lim, Stefan Kachel, Adriana DM Villa, Leighton Kearney, Nuno Bettencourt, Alistair A Young, Amedeo Chiribiri, Cian M Scannell

    Abstract: Objectives: To develop an image-based automatic deep learning method to classify cardiac MR images by sequence type and imaging plane for improved clinical post-processing efficiency. Methods: Multi-vendor cardiac MRI studies were retrospectively collected from 4 centres and 3 vendors. A two-head convolutional neural network ('CardiSort') was trained to classify 35 sequences by imaging sequence (n… ▽ More

    Submitted 8 April, 2022; v1 submitted 17 September, 2021; originally announced September 2021.

    Comments: Published in European Radiology 2022

    Journal ref: European Radiology 2022

  3. arXiv:2105.04690  [pdf, other

    eess.IV physics.med-ph

    Automated quantitative analysis of first-pass myocardial perfusion magnetic resonance imaging data

    Authors: Cian M Scannell

    Abstract: Coronary artery disease (CAD) remains the world's leading cause of mortality and the disease burden is continually expanding as the population ages. Recently, the MR-INFORM randomised trial has demonstrated that the management of patients with stable CAD can be guided by stress perfusion cardiovascular magnetic resonance (CMR) imaging and it is non-inferior to the using the invasive reference stan… ▽ More

    Submitted 10 May, 2021; originally announced May 2021.

    Comments: PhD Thesis. King's College London (University of London)

  4. arXiv:2011.12844  [pdf, other

    eess.IV cs.CV physics.med-ph

    Physics-informed neural networks for myocardial perfusion MRI quantification

    Authors: Rudolf L. M. van Herten, Amedeo Chiribiri, Marcel Breeuwer, Mitko Veta, Cian M. Scannell

    Abstract: Tracer-kinetic models allow for the quantification of kinetic parameters such as blood flow from dynamic contrast-enhanced magnetic resonance (MR) images. Fitting the observed data with multi-compartment exchange models is desirable, as they are physiologically plausible and resolve directly for blood flow and microvascular function. However, the reliability of model fitting is limited by the low… ▽ More

    Submitted 7 April, 2022; v1 submitted 25 November, 2020; originally announced November 2020.

    Comments: Published in Medical Image Analysis

  5. arXiv:2010.08469  [pdf, other

    eess.IV

    Automatic Myocardial Disease Prediction From Delayed-Enhancement Cardiac MRI and Clinical Information

    Authors: Ana Lourenço, Eric Kerfoot, Irina Grigorescu, Cian M Scannell, Marta Varela, Teresa M Correia

    Abstract: Delayed-enhancement cardiac magnetic resonance (DE-CMR)provides important diagnostic and prognostic information on myocardial viability. The presence and extent of late gadolinium enhancement (LGE)in DE-CMR is negatively associated with the probability of improvement in left ventricular function after revascularization. Moreover, LGE findings can support the diagnosis of several other cardiomyopat… ▽ More

    Submitted 16 October, 2020; originally announced October 2020.

    Comments: Accepted for the EMIDEC classification challenge; part of the 11th Statistical Atlases and Computational Modelling of the Heart (STACOM 2020), a MICCAI satellite workshop

  6. arXiv:2008.11776  [pdf, other

    eess.IV cs.CV

    Domain-Adversarial Learning for Multi-Centre, Multi-Vendor, and Multi-Disease Cardiac MR Image Segmentation

    Authors: Cian M. Scannell, Amedeo Chiribiri, Mitko Veta

    Abstract: Cine cardiac magnetic resonance (CMR) has become the gold standard for the non-invasive evaluation of cardiac function. In particular, it allows the accurate quantification of functional parameters including the chamber volumes and ejection fraction. Deep learning has shown the potential to automate the requisite cardiac structure segmentation. However, the lack of robustness of deep learning mode… ▽ More

    Submitted 26 August, 2020; originally announced August 2020.

    Comments: Accepted at the STACOM workshop at MICCAI 2020

  7. arXiv:1907.11899  [pdf, other

    eess.IV cs.CV physics.med-ph q-bio.QM

    Deep learning-based prediction of kinetic parameters from myocardial perfusion MRI

    Authors: Cian M. Scannell, Piet van den Bosch, Amedeo Chiribiri, Jack Lee, Marcel Breeuwer, Mitko Veta

    Abstract: The quantification of myocardial perfusion MRI has the potential to provide a fast, automated and user-independent assessment of myocardial ischaemia. However, due to the relatively high noise level and low temporal resolution of the acquired data and the complexity of the tracer-kinetic models, the model fitting can yield unreliable parameter estimates. A solution to this problem is the use of Ba… ▽ More

    Submitted 27 July, 2019; originally announced July 2019.

    Comments: Medical Imaging with Deep Learning: MIDL 2019 Extended Abstract Track. MIDL 2019 [arXiv:1907.08612]

    Report number: MIDL/2019/ExtendedAbstract/HyxyNmQAF4

  8. arXiv:1906.02540  [pdf

    eess.IV cs.CV physics.med-ph

    Hierarchical Bayesian myocardial perfusion quantification

    Authors: Cian M. Scannell, Amedeo Chiribiri, Adriana D. M. Villa, Marcel Breeuwer, Jack Lee

    Abstract: Purpose: Tracer-kinetic models can be used for the quantitative assessment of contrast-enhanced MRI data. However, the model-fitting can produce unreliable results due to the limited data acquired and the high noise levels. Such problems are especially prevalent in myocardial perfusion MRI leading to the compromise of constrained numerical deconvolutions and segmental signal averaging being common… ▽ More

    Submitted 21 November, 2019; v1 submitted 6 June, 2019; originally announced June 2019.

    Comments: Published in Medical Image Analysis