Modeling Multivariate Biosignals With Graph Neural Networks and Structured State Space Models
Authors:
Siyi Tang,
Jared A. Dunnmon,
Liangqiong Qu,
Khaled K. Saab,
Tina Baykaner,
Christopher Lee-Messer,
Daniel L. Rubin
Abstract:
Multivariate biosignals are prevalent in many medical domains, such as electroencephalography, polysomnography, and electrocardiography. Modeling spatiotemporal dependencies in multivariate biosignals is challenging due to (1) long-range temporal dependencies and (2) complex spatial correlations between the electrodes. To address these challenges, we propose representing multivariate biosignals as…
▽ More
Multivariate biosignals are prevalent in many medical domains, such as electroencephalography, polysomnography, and electrocardiography. Modeling spatiotemporal dependencies in multivariate biosignals is challenging due to (1) long-range temporal dependencies and (2) complex spatial correlations between the electrodes. To address these challenges, we propose representing multivariate biosignals as time-dependent graphs and introduce GraphS4mer, a general graph neural network (GNN) architecture that improves performance on biosignal classification tasks by modeling spatiotemporal dependencies in biosignals. Specifically, (1) we leverage the Structured State Space architecture, a state-of-the-art deep sequence model, to capture long-range temporal dependencies in biosignals and (2) we propose a graph structure learning layer in GraphS4mer to learn dynamically evolving graph structures in the data. We evaluate our proposed model on three distinct biosignal classification tasks and show that GraphS4mer consistently improves over existing models, including (1) seizure detection from electroencephalographic signals, outperforming a previous GNN with self-supervised pre-training by 3.1 points in AUROC; (2) sleep staging from polysomnographic signals, a 4.1 points improvement in macro-F1 score compared to existing sleep staging models; and (3) 12-lead electrocardiogram classification, outperforming previous state-of-the-art models by 2.7 points in macro-F1 score.
△ Less
Submitted 29 April, 2023; v1 submitted 20 November, 2022;
originally announced November 2022.
-
SplitAVG: A heterogeneity-aware federated deep learning method for medical imaging
Authors:
Miao Zhang,
Liangqiong Qu,
Praveer Singh,
Jayashree Kalpathy-Cramer,
Daniel L. Rubin
Abstract:
Federated learning is an emerging research paradigm for enabling collaboratively training deep learning models without sharing patient data. However, the data from different institutions are usually heterogeneous across institutions, which may reduce the performance of models trained using federated learning. In this study, we propose a novel heterogeneity-aware federated learning method, SplitAVG…
▽ More
Federated learning is an emerging research paradigm for enabling collaboratively training deep learning models without sharing patient data. However, the data from different institutions are usually heterogeneous across institutions, which may reduce the performance of models trained using federated learning. In this study, we propose a novel heterogeneity-aware federated learning method, SplitAVG, to overcome the performance drops from data heterogeneity in federated learning. Unlike previous federated methods that require complex heuristic training or hyper parameter tuning, our SplitAVG leverages the simple network split and feature map concatenation strategies to encourage the federated model training an unbiased estimator of the target data distribution. We compare SplitAVG with seven state-of-the-art federated learning methods, using centrally hosted training data as the baseline on a suite of both synthetic and real-world federated datasets. We find that the performance of models trained using all the comparison federated learning methods degraded significantly with the increasing degrees of data heterogeneity. In contrast, SplitAVG method achieves comparable results to the baseline method under all heterogeneous settings, that it achieves 96.2% of the accuracy and 110.4% of the mean absolute error obtained by the baseline in a diabetic retinopathy binary classification dataset and a bone age prediction dataset, respectively, on highly heterogeneous data partitions. We conclude that SplitAVG method can effectively overcome the performance drops from variability in data distributions across institutions. Experimental results also show that SplitAVG can be adapted to different base networks and generalized to various types of medical imaging tasks.
△ Less
Submitted 10 April, 2022; v1 submitted 5 July, 2021;
originally announced July 2021.
-
COVID-19 Lung Lesion Segmentation Using a Sparsely Supervised Mask R-CNN on Chest X-rays Automatically Computed from Volumetric CTs
Authors:
Vignav Ramesh,
Blaine Rister,
Daniel L. Rubin
Abstract:
Chest X-rays of coronavirus disease 2019 (COVID-19) patients are frequently obtained to determine the extent of lung disease and are a valuable source of data for creating artificial intelligence models. Most work to date assessing disease severity on chest imaging has focused on segmenting computed tomography (CT) images; however, given that CTs are performed much less frequently than chest X-ray…
▽ More
Chest X-rays of coronavirus disease 2019 (COVID-19) patients are frequently obtained to determine the extent of lung disease and are a valuable source of data for creating artificial intelligence models. Most work to date assessing disease severity on chest imaging has focused on segmenting computed tomography (CT) images; however, given that CTs are performed much less frequently than chest X-rays for COVID-19 patients, automated lung lesion segmentation on chest X-rays could be clinically valuable. There currently exists a universal shortage of chest X-rays with ground truth COVID-19 lung lesion annotations, and manually contouring lung opacities is a tedious, labor-intensive task. To accelerate severity detection and augment the amount of publicly available chest X-ray training data for supervised deep learning (DL) models, we leverage existing annotated CT images to generate frontal projection "chest X-ray" images for training COVID-19 chest X-ray models. In this paper, we propose an automated pipeline for segmentation of COVID-19 lung lesions on chest X-rays comprised of a Mask R-CNN trained on a mixed dataset of open-source chest X-rays and coronal X-ray projections computed from annotated volumetric CTs. On a test set containing 40 chest X-rays of COVID-19 positive patients, our model achieved IoU scores of 0.81 $\pm$ 0.03 and 0.79 $\pm$ 0.03 when trained on a dataset of 60 chest X-rays and on a mixed dataset of 10 chest X-rays and 50 projections from CTs, respectively. Our model far outperforms current baselines with limited supervised training and may assist in automated COVID-19 severity quantification on chest X-rays.
△ Less
Submitted 19 May, 2021; v1 submitted 17 May, 2021;
originally announced May 2021.
-
Self-Supervised Graph Neural Networks for Improved Electroencephalographic Seizure Analysis
Authors:
Siyi Tang,
Jared A. Dunnmon,
Khaled Saab,
Xuan Zhang,
Qianying Huang,
Florian Dubost,
Daniel L. Rubin,
Christopher Lee-Messer
Abstract:
Automated seizure detection and classification from electroencephalography (EEG) can greatly improve seizure diagnosis and treatment. However, several modeling challenges remain unaddressed in prior automated seizure detection and classification studies: (1) representing non-Euclidean data structure in EEGs, (2) accurately classifying rare seizure types, and (3) lacking a quantitative interpretabi…
▽ More
Automated seizure detection and classification from electroencephalography (EEG) can greatly improve seizure diagnosis and treatment. However, several modeling challenges remain unaddressed in prior automated seizure detection and classification studies: (1) representing non-Euclidean data structure in EEGs, (2) accurately classifying rare seizure types, and (3) lacking a quantitative interpretability approach to measure model ability to localize seizures. In this study, we address these challenges by (1) representing the spatiotemporal dependencies in EEGs using a graph neural network (GNN) and proposing two EEG graph structures that capture the electrode geometry or dynamic brain connectivity, (2) proposing a self-supervised pre-training method that predicts preprocessed signals for the next time period to further improve model performance, particularly on rare seizure types, and (3) proposing a quantitative model interpretability approach to assess a model's ability to localize seizures within EEGs. When evaluating our approach on seizure detection and classification on a large public dataset, we find that our GNN with self-supervised pre-training achieves 0.875 Area Under the Receiver Operating Characteristic Curve on seizure detection and 0.749 weighted F1-score on seizure classification, outperforming previous methods for both seizure detection and classification. Moreover, our self-supervised pre-training strategy significantly improves classification of rare seizure types. Furthermore, quantitative interpretability analysis shows that our GNN with self-supervised pre-training precisely localizes 25.4% focal seizures, a 21.9 point improvement over existing CNNs. Finally, by superimposing the identified seizure locations on both raw EEG signals and EEG graphs, our approach could provide clinicians with an intuitive visualization of localized seizure regions.
△ Less
Submitted 13 March, 2022; v1 submitted 16 April, 2021;
originally announced April 2021.
-
Learning domain-agnostic visual representation for computational pathology using medically-irrelevant style transfer augmentation
Authors:
Rikiya Yamashita,
** Long,
Snikitha Banda,
Jeanne Shen,
Daniel L. Rubin
Abstract:
Suboptimal generalization of machine learning models on unseen data is a key challenge which hampers the clinical applicability of such models to medical imaging. Although various methods such as domain adaptation and domain generalization have evolved to combat this challenge, learning robust and generalizable representations is core to medical image understanding, and continues to be a problem.…
▽ More
Suboptimal generalization of machine learning models on unseen data is a key challenge which hampers the clinical applicability of such models to medical imaging. Although various methods such as domain adaptation and domain generalization have evolved to combat this challenge, learning robust and generalizable representations is core to medical image understanding, and continues to be a problem. Here, we propose STRAP (Style TRansfer Augmentation for histoPathology), a form of data augmentation based on random style transfer from non-medical style source such as artistic paintings, for learning domain-agnostic visual representations in computational pathology. Style transfer replaces the low-level texture content of an image with the uninformative style of randomly selected style source image, while preserving the original high-level semantic content. This improves robustness to domain shift and can be used as a simple yet powerful tool for learning domain-agnostic representations. We demonstrate that STRAP leads to state-of-the-art performance, particularly in the presence of domain shifts, on two particular classification tasks in computational pathology.
△ Less
Submitted 3 June, 2021; v1 submitted 2 February, 2021;
originally announced February 2021.
-
Data Valuation for Medical Imaging Using Shapley Value: Application on A Large-scale Chest X-ray Dataset
Authors:
Siyi Tang,
Amirata Ghorbani,
Rikiya Yamashita,
Sameer Rehman,
Jared A. Dunnmon,
James Zou,
Daniel L. Rubin
Abstract:
The reliability of machine learning models can be compromised when trained on low quality data. Many large-scale medical imaging datasets contain low quality labels extracted from sources such as medical reports. Moreover, images within a dataset may have heterogeneous quality due to artifacts and biases arising from equipment or measurement errors. Therefore, algorithms that can automatically ide…
▽ More
The reliability of machine learning models can be compromised when trained on low quality data. Many large-scale medical imaging datasets contain low quality labels extracted from sources such as medical reports. Moreover, images within a dataset may have heterogeneous quality due to artifacts and biases arising from equipment or measurement errors. Therefore, algorithms that can automatically identify low quality data are highly desired. In this study, we used data Shapley, a data valuation metric, to quantify the value of training data to the performance of a pneumonia detection algorithm in a large chest X-ray dataset. We characterized the effectiveness of data Shapley in identifying low quality versus valuable data for pneumonia detection. We found that removing training data with high Shapley values decreased the pneumonia detection performance, whereas removing data with low Shapley values improved the model performance. Furthermore, there were more mislabeled examples in low Shapley value data and more true pneumonia cases in high Shapley value data. Our results suggest that low Shapley value indicates mislabeled or poor quality images, whereas high Shapley value indicates data that are valuable for pneumonia detection. Our method can serve as a framework for using data Shapley to denoise large-scale medical imaging datasets.
△ Less
Submitted 15 October, 2020;
originally announced October 2020.
-
Plexus Convolutional Neural Network (PlexusNet): A novel neural network architecture for histologic image analysis
Authors:
Okyaz Eminaga,
Mahmoud Abbas,
Christian Kunder,
Andreas M. Loening,
Jeanne Shen,
James D. Brooks,
Curtis P. Langlotz,
Daniel L. Rubin
Abstract:
Different convolutional neural network (CNN) models have been tested for their application in histological image analyses. However, these models are prone to overfitting due to their large parameter capacity, requiring more data or valuable computational resources for model training. Given these limitations, we introduced a novel architecture (termed PlexusNet). We utilized 310 Hematoxylin and Eos…
▽ More
Different convolutional neural network (CNN) models have been tested for their application in histological image analyses. However, these models are prone to overfitting due to their large parameter capacity, requiring more data or valuable computational resources for model training. Given these limitations, we introduced a novel architecture (termed PlexusNet). We utilized 310 Hematoxylin and Eosin stained (H&E) annotated histological images of prostate cancer cases from TCGA-PRAD and Stanford University and 398 H&E whole slides images from the Camelyon 2016 challenge. PlexusNet-architecture -derived models were compared to models derived from several existing "state of the art" architectures. We measured discrimination accuracy, calibration, and clinical utility. An ablation study was conducted to study the effect of each component of PlexusNet on model performance. A well-fitted PlexusNet-based model delivered comparable classification performance (AUC: 0.963) in distinguishing prostate cancer from healthy tissues, although it was at least 23 times smaller, had a better model calibration and clinical utility than the comparison models. A separate smaller PlexusNet model accurately detected slides with breast cancer metastases (AUC: 0.978); it helped reduce the slide number to examine by 43.8% without consequences, although its parameter capacity was 200 times smaller than ResNet18. We found that the partitioning of the development set influences the model calibration for all models. However, with PlexusNet architecture, we could achieve comparable well-calibrated models trained on different partitions. In conclusion, PlexusNet represents a novel model architecture for histological image analysis that achieves classification performance comparable to other models while providing orders-of-magnitude parameter reduction.
△ Less
Submitted 3 June, 2020; v1 submitted 23 August, 2019;
originally announced August 2019.
-
Deep Learning Enables Automatic Detection and Segmentation of Brain Metastases on Multi-Sequence MRI
Authors:
Endre Grøvik,
Darvin Yi,
Michael Iv,
Elisabeth Tong,
Daniel L. Rubin,
Greg Zaharchuk
Abstract:
Detecting and segmenting brain metastases is a tedious and time-consuming task for many radiologists, particularly with the growing use of multi-sequence 3D imaging. This study demonstrates automated detection and segmentation of brain metastases on multi-sequence MRI using a deep learning approach based on a fully convolution neural network (CNN). In this retrospective study, a total of 156 patie…
▽ More
Detecting and segmenting brain metastases is a tedious and time-consuming task for many radiologists, particularly with the growing use of multi-sequence 3D imaging. This study demonstrates automated detection and segmentation of brain metastases on multi-sequence MRI using a deep learning approach based on a fully convolution neural network (CNN). In this retrospective study, a total of 156 patients with brain metastases from several primary cancers were included. Pre-therapy MR images (1.5T and 3T) included pre- and post-gadolinium T1-weighted 3D fast spin echo, post-gadolinium T1-weighted 3D axial IR-prepped FSPGR, and 3D fluid attenuated inversion recovery. The ground truth was established by manual delineation by two experienced neuroradiologists. CNN training/development was performed using 100 and 5 patients, respectively, with a 2.5D network based on a GoogLeNet architecture. The results were evaluated in 51 patients, equally separated into those with few (1-3), multiple (4-10), and many (>10) lesions. Network performance was evaluated using precision, recall, Dice/F1 score, and ROC-curve statistics. For an optimal probability threshold, detection and segmentation performance was assessed on a per metastasis basis. The area under the ROC-curve (AUC), averaged across all patients, was 0.98. The AUC in the subgroups was 0.99, 0.97, and 0.97 for patients having 1-3, 4-10, and >10 metastases, respectively. Using an average optimal probability threshold determined by the development set, precision, recall, and Dice-score were 0.79, 0.53, and 0.79, respectively. At the same probability threshold, the network showed an average false positive rate of 8.3/patient (no lesion-size limit) and 3.4/patient (10 mm3 lesion size limit). In conclusion, a deep learning approach using multi-sequence MRI can aid in the detection and segmentation of brain metastases.
△ Less
Submitted 18 March, 2019;
originally announced March 2019.