Performance assessment of medical and non-medical CPAP interfaces used during the COVID-19 pandemic
Authors:
Marco Marini,
Lorenzo Capponi,
Ilaria Battistoni,
Tommaso Tocci,
Giulio Tribbiani,
Francesco Merante,
Matteo Francioni,
Maria Vittoria Matassini,
Giulia Pongetti,
Matilda Skhoza,
Luca Angelini,
Roberto Marsili,
Marco Mazzanti,
Gian Piero Perna,
Gianluca Rossi,
Alberto Gili
Abstract:
Background: At the beginning of 2020, a high number of COVID-19 cases affected Italy in a short period, causing a difficult supply of medical equipment. To deal with the problem, many healthcare operators readapted different masks to medical devices, but no experiment was conducted to evaluate their performance. The aims of our study were: to assess the performances of three masks and a CPAP helme…
▽ More
Background: At the beginning of 2020, a high number of COVID-19 cases affected Italy in a short period, causing a difficult supply of medical equipment. To deal with the problem, many healthcare operators readapted different masks to medical devices, but no experiment was conducted to evaluate their performance. The aims of our study were: to assess the performances of three masks and a CPAP helmet in their original configuration and after modifications, in the maintenance of mean pressure and half-amplitude variations using different PEEP valves and to analyse the impact of antibacterial (AB) or antibacterial-viral (ABV) pre-valve PEEP filters on the effective PEEP delivered to the patients. Four pressure ports were installed on each mask (three on helmet), mean values and half amplitudes of pressure were recorded. Tests were performed with any, AB, ABV filter before the PEEP valve. CPAP helmet was the most efficient interface producing more stable mean pressure and less prominent half-amplitude variations but the non-medical masks, especially after the modifications, maintained a stable mean pressure value with only a moderate increase of half-amplitude. The use of AB and ABV filters, produced respectively an increase of 2,23% and 16.5% in mean pressure, compared to no filter condition. CPAP helmet is the most reliable interface in terms of detected performance, but readapted masks can assure almost a similar performance. The use of ABV filters before the PEEP valve significantly increases the detected mean pressure while the AB filters have almost a neutral effect.
△ Less
Submitted 9 May, 2022;
originally announced May 2022.
-
Motion Compensated Whole-Heart Coronary Magnetic Resonance Angiography using Focused Navigation (fNAV)
Authors:
Christopher W Roy,
John Heerfordt,
Davide Piccini,
Giulia Rossi,
Anna Giulia Pavon,
Juerg Schwitter,
Matthias Stuber
Abstract:
Background: RSN whole-heart CMRA is a technique that estimates and corrects for respiratory motion. However, RSN has been limited to a 1D rigid correction which is often insufficient for patients with complex respiratory patterns. The goal of this work is therefore to improve the robustness and quality of 3D radial CMRA by incorporating both 3D motion information and nonrigid intra-acquisition cor…
▽ More
Background: RSN whole-heart CMRA is a technique that estimates and corrects for respiratory motion. However, RSN has been limited to a 1D rigid correction which is often insufficient for patients with complex respiratory patterns. The goal of this work is therefore to improve the robustness and quality of 3D radial CMRA by incorporating both 3D motion information and nonrigid intra-acquisition correction of the data into a framework called focused navigation (fNAV). Methods: We applied fNAV to 500 data sets from a numerical simulation, 22 healthy volunteers, and 549 cardiac patients. We compared fNAV to RSN and respiratory resolved XD-GRASP reconstructions of the same data and recorded reconstruction times. Motion accuracy was measured as the correlation between fNAV and ground truth for simulations, and fNAV and image registration for in vivo data. Vessel sharpness was measured using Soap-Bubble. Finally, image quality analysis was performed by a blinded expert reviewer who chose the best image for each data set. Results The reconstruction time for fNAV images was significantly higher than RSN (6.1 +/- 2.1 minutes vs 1.4 +/- 0.3, minutes, p<0.025) but significantly lower than XD-GRASP (25.6 +/- 7.1, minutes, p<0.025). There is high correlation between the fNAV, and reference displacement estimates across all data sets (0.73 +/- 0.29). For all data, fNAV lead to significantly sharper vessels than all other reconstructions (p < 0.01). Finally, a blinded reviewer chose fNAV as the best image in 239 out of 571 cases (p = 10-5). Conclusion: fNAV is a promising technique for improving free-breathing 3D radial whole-heart CMRA. This novel approach to respiratory self-navigation can derive 3D nonrigid motion estimations from an acquired 1D signal yielding statistically significant improvement in image sharpness relative to 1D translational correction as well as XD-GRASP reconstructions.
△ Less
Submitted 27 October, 2020;
originally announced October 2020.
-
An Analysis of Sampling Effect on the Absolute Stability of Discrete-time Bilateral Teleoperation Systems
Authors:
Amir Aminzadeh Ghavifekr,
Seyedshahab Chehraghi,
Giacomo De Rossi
Abstract:
Absolute stability of discrete-time teleoperation systems can be jeopardized by choosing inappropriate sampling time architecture. A modified structure is presented for the bilateral teleoperation system including continuous-time slave robot, master robot, human operator, and the environment with sampled-data PD-like + dissipation controllers which make the system absolute stable in the presence o…
▽ More
Absolute stability of discrete-time teleoperation systems can be jeopardized by choosing inappropriate sampling time architecture. A modified structure is presented for the bilateral teleoperation system including continuous-time slave robot, master robot, human operator, and the environment with sampled-data PD-like + dissipation controllers which make the system absolute stable in the presence of the time delay and sampling rates in the communication network. The output position and force signals are quantized with uniform sampling periods. Input-delay approach is used in this paper to convert the sampled-data system to a continuous-time counterpart. The main contribution of this paper is calculating a lower bound on the maximum sampling period as a stability condition. Also, the presented method imposes upper bounds on the dam** of robots and notifies the sampling time importance on the transparency and stability of the system. Both simulation and experimental results are performed to show the validity of the proposed conditions and verify the effectiveness of the sampling scheme.
△ Less
Submitted 15 August, 2020;
originally announced August 2020.