-
Investigation of mmWave Radar Technology For Non-contact Vital Sign Monitoring
Authors:
Steven Marty,
Federico Pantanella,
Andrea Ronco,
Kanika Dheman,
Michele Magno
Abstract:
Non-contact vital sign monitoring has many advantages over conventional methods in being comfortable, unobtrusive and without any risk of spreading infection. The use of millimeter-wave (mmWave) radars is one of the most promising approaches that enable contact-less monitoring of vital signs. Novel low-power implementations of this technology promise to enable vital sign sensing in embedded, batte…
▽ More
Non-contact vital sign monitoring has many advantages over conventional methods in being comfortable, unobtrusive and without any risk of spreading infection. The use of millimeter-wave (mmWave) radars is one of the most promising approaches that enable contact-less monitoring of vital signs. Novel low-power implementations of this technology promise to enable vital sign sensing in embedded, battery-operated devices. The nature of these new low-power sensors exacerbates the challenges of accurate and robust vital sign monitoring and especially the problem of heart-rate tracking. This work focuses on the investigation and characterization of three Frequency Modulated Continuous Wave (FMCW) low-power radars with different carrier frequencies of 24 GHz, 60 GHz and 120 GHz. The evaluation platforms were first tested on phantom models that emulated human bodies to accurately evaluate the baseline noise, error in range estimation, and error in displacement estimation. Additionally, the systems were also used to collect data from three human subjects to gauge the feasibility of identifying heartbeat peaks and breathing peaks with simple and lightweight algorithms that could potentially run in low-power embedded processors. The investigation revealed that the 24 GHz radar has the highest baseline noise level, 0.04mm at 0° angle of incidence, and an error in range estimation of 3.45 +- 1.88 cm at a distance of 60 cm. At the same distance, the 60 GHz and the 120 GHz radar system shows the least noise level, 0.0lmm at 0° angle of incidence, and error in range estimation 0.64 +- 0.01 cm and 0.04 +- 0.0 cm respectively. Additionally, tests on humans showed that all three radar systems were able to identify heart and breathing activity but the 120 GHz radar system outperformed the other two.
△ Less
Submitted 15 September, 2023;
originally announced September 2023.
-
In-Ear-Voice: Towards Milli-Watt Audio Enhancement With Bone-Conduction Microphones for In-Ear Sensing Platforms
Authors:
Philipp Schilk,
Niccolò Polvani,
Andrea Ronco,
Milos Cernak,
Michele Magno
Abstract:
The recent ubiquitous adoption of remote conferencing has been accompanied by omnipresent frustration with distorted or otherwise unclear voice communication. Audio enhancement can compensate for low-quality input signals from, for example, small true wireless earbuds, by applying noise suppression techniques. Such processing relies on voice activity detection (VAD) with low latency and the added…
▽ More
The recent ubiquitous adoption of remote conferencing has been accompanied by omnipresent frustration with distorted or otherwise unclear voice communication. Audio enhancement can compensate for low-quality input signals from, for example, small true wireless earbuds, by applying noise suppression techniques. Such processing relies on voice activity detection (VAD) with low latency and the added capability of discriminating the wearer's voice from others - a task of significant computational complexity. The tight energy budget of devices as small as modern earphones, however, requires any system attempting to tackle this problem to do so with minimal power and processing overhead, while not relying on speaker-specific voice samples and training due to usability concerns.
This paper presents the design and implementation of a custom research platform for low-power wireless earbuds based on novel, commercial, MEMS bone-conduction microphones. Such microphones can record the wearer's speech with much greater isolation, enabling personalized voice activity detection and further audio enhancement applications. Furthermore, the paper accurately evaluates a proposed low-power personalized speech detection algorithm based on bone conduction data and a recurrent neural network running on the implemented research platform. This algorithm is compared to an approach based on traditional microphone input. The performance of the bone conduction system, achieving detection of speech within 12.8ms at an accuracy of 95\% is evaluated. Different SoC choices are contrasted, with the final implementation based on the cutting-edge Ambiq Apollo 4 Blue SoC achieving 2.64mW average power consumption at 14uJ per inference, reaching 43h of battery life on a miniature 32mAh li-ion cell and without duty cycling.
△ Less
Submitted 5 September, 2023;
originally announced September 2023.
-
Towards Robust Velocity and Position Estimation of Opponents for Autonomous Racing Using Low-Power Radar
Authors:
Andrea Ronco,
Nicolas Baumann,
Marco Giordano,
Michele Magno
Abstract:
This paper presents the design and development of an intelligent subsystem that includes a novel low-power radar sensor integrated into an autonomous racing perception pipeline to robustly estimate the position and velocity of dynamic obstacles. The proposed system, based on the Infineon BGT60TR13D radar, is evaluated in a real-world scenario with scaled race cars. The paper explores the benefits…
▽ More
This paper presents the design and development of an intelligent subsystem that includes a novel low-power radar sensor integrated into an autonomous racing perception pipeline to robustly estimate the position and velocity of dynamic obstacles. The proposed system, based on the Infineon BGT60TR13D radar, is evaluated in a real-world scenario with scaled race cars. The paper explores the benefits and limitations of using such a sensor subsystem and draws conclusions based on field-collected data. The results demonstrate a tracking error up to 0.21 +- 0.29 m in distance estimation and 0.39 +- 0.19 m/s in velocity estimation, despite the power consumption in the range of 10s of milliwatts. The presented system provides complementary information to other sensors such as LiDAR and camera, and can be used in a wide range of applications beyond autonomous racing.
△ Less
Submitted 4 September, 2023;
originally announced September 2023.
-
Lung airway geometry as an early predictor of autism: A preliminary machine learning-based study
Authors:
Asef Islam,
Anthony Ronco,
Stephen M. Becker,
Jeremiah Blackburn,
Johannes C. Schittny,
Kyoungmi Kim,
Rebecca Stein-Wexler,
Anthony S. Wexler
Abstract:
The goal of this study is to assess the feasibility of airway geometry as a biomarker for ASD. Chest CT images of children with a documented diagnosis of ASD as well as healthy controls were identified retrospectively. 54 scans were obtained for analysis, including 31 ASD cases and 23 age and sex-matched controls. A feature selection and classification procedure using principal component analysis…
▽ More
The goal of this study is to assess the feasibility of airway geometry as a biomarker for ASD. Chest CT images of children with a documented diagnosis of ASD as well as healthy controls were identified retrospectively. 54 scans were obtained for analysis, including 31 ASD cases and 23 age and sex-matched controls. A feature selection and classification procedure using principal component analysis (PCA) and support vector machine (SVM) achieved a peak cross validation accuracy of nearly 89% using a feature set of 8 airway branching angles. Sensitivity was 94%, but specificity was only 78%. The results suggest a measurable difference in airway branchpoint angles between children with ASD and the control population. Under review at Scientific Reports
△ Less
Submitted 9 February, 2023; v1 submitted 13 January, 2023;
originally announced January 2023.