-
Dose-aware Diffusion Model for 3D Low-dose PET: Multi-institutional Validation with Reader Study and Real Low-dose Data
Authors:
Huidong Xie,
Weijie Gan,
Bo Zhou,
Ming-Kai Chen,
Michal Kulon,
Annemarie Boustani,
Benjamin A. Spencer,
Reimund Bayerlein,
Xiongchao Chen,
Qiong Liu,
Xueqi Guo,
Menghua Xia,
Yinchi Zhou,
Hui Liu,
Liang Guo,
Hongyu An,
Ulugbek S. Kamilov,
Hanzhong Wang,
Biao Li,
Axel Rominger,
Kuangyu Shi,
Ge Wang,
Ramsey D. Badawi,
Chi Liu
Abstract:
As PET imaging is accompanied by radiation exposure and potentially increased cancer risk, reducing radiation dose in PET scans without compromising the image quality is an important topic. Deep learning (DL) techniques have been investigated for low-dose PET imaging. However, existing models have often resulted in compromised image quality when achieving low-dose PET and have limited generalizabi…
▽ More
As PET imaging is accompanied by radiation exposure and potentially increased cancer risk, reducing radiation dose in PET scans without compromising the image quality is an important topic. Deep learning (DL) techniques have been investigated for low-dose PET imaging. However, existing models have often resulted in compromised image quality when achieving low-dose PET and have limited generalizability to different image noise-levels, acquisition protocols, patient populations, and hospitals. Recently, diffusion models have emerged as the new state-of-the-art generative model to generate high-quality samples and have demonstrated strong potential for medical imaging tasks. However, for low-dose PET imaging, existing diffusion models failed to generate consistent 3D reconstructions, unable to generalize across varying noise-levels, often produced visually-appealing but distorted image details, and produced images with biased tracer uptake. Here, we develop DDPET-3D, a dose-aware diffusion model for 3D low-dose PET imaging to address these challenges. Collected from 4 medical centers globally with different scanners and clinical protocols, we extensively evaluated the proposed model using a total of 9,783 18F-FDG studies (1,596 patients) with low-dose/low-count levels ranging from 1% to 50%. With a cross-center, cross-scanner validation, the proposed DDPET-3D demonstrated its potential to generalize to different low-dose levels, different scanners, and different clinical protocols. As confirmed with reader studies performed by nuclear medicine physicians, the proposed method produced superior denoised results that are comparable to or even better than the 100% full-count images as well as previous DL baselines. The presented results show the potential of achieving low-dose PET while maintaining image quality. Lastly, a group of real low-dose scans was also included for evaluation.
△ Less
Submitted 2 May, 2024;
originally announced May 2024.
-
LpQcM: Adaptable Lesion-Quantification-Consistent Modulation for Deep Learning Low-Count PET Image Denoising
Authors:
Menghua Xia,
Huidong Xie,
Qiong Liu,
Bo Zhou,
Hanzhong Wang,
Biao Li,
Axel Rominger,
Kuangyu Shi,
Georges EI Fakhri,
Chi Liu
Abstract:
Deep learning-based positron emission tomography (PET) image denoising offers the potential to reduce radiation exposure and scanning time by transforming low-count images into high-count equivalents. However, existing methods typically blur crucial details, leading to inaccurate lesion quantification. This paper proposes a lesion-perceived and quantification-consistent modulation (LpQcM) strategy…
▽ More
Deep learning-based positron emission tomography (PET) image denoising offers the potential to reduce radiation exposure and scanning time by transforming low-count images into high-count equivalents. However, existing methods typically blur crucial details, leading to inaccurate lesion quantification. This paper proposes a lesion-perceived and quantification-consistent modulation (LpQcM) strategy for enhanced PET image denoising, via employing downstream lesion quantification analysis as auxiliary tools. The LpQcM is a plug-and-play design adaptable to a wide range of model architectures, modulating the sampling and optimization procedures of model training without adding any computational burden to the inference phase. Specifically, the LpQcM consists of two components, the lesion-perceived modulation (LpM) and the multiscale quantification-consistent modulation (QcM). The LpM enhances lesion contrast and visibility by allocating higher sampling weights and stricter loss criteria to lesion-present samples determined by an auxiliary segmentation network than lesion-absent ones. The QcM further emphasizes accuracy of quantification for both the mean and maximum standardized uptake value (SUVmean and SUVmax) across multiscale sub-regions throughout the entire image, thereby enhancing the overall image quality. Experiments conducted on large PET datasets from multiple centers and vendors, and varying noise levels demonstrated the LpQcM efficacy across various denoising frameworks. Compared to frameworks without LpQcM, the integration of LpQcM reduces the lesion SUVmean bias by 2.92% on average and increases the peak signal-to-noise ratio (PSNR) by 0.34 on average, for denoising images of extremely low-count levels below 10%.
△ Less
Submitted 27 April, 2024;
originally announced April 2024.
-
FedFTN: Personalized Federated Learning with Deep Feature Transformation Network for Multi-institutional Low-count PET Denoising
Authors:
Bo Zhou,
Huidong Xie,
Qiong Liu,
Xiongchao Chen,
Xueqi Guo,
Zhicheng Feng,
Jun Hou,
S. Kevin Zhou,
Biao Li,
Axel Rominger,
Kuangyu Shi,
James S. Duncan,
Chi Liu
Abstract:
Low-count PET is an efficient way to reduce radiation exposure and acquisition time, but the reconstructed images often suffer from low signal-to-noise ratio (SNR), thus affecting diagnosis and other downstream tasks. Recent advances in deep learning have shown great potential in improving low-count PET image quality, but acquiring a large, centralized, and diverse dataset from multiple institutio…
▽ More
Low-count PET is an efficient way to reduce radiation exposure and acquisition time, but the reconstructed images often suffer from low signal-to-noise ratio (SNR), thus affecting diagnosis and other downstream tasks. Recent advances in deep learning have shown great potential in improving low-count PET image quality, but acquiring a large, centralized, and diverse dataset from multiple institutions for training a robust model is difficult due to privacy and security concerns of patient data. Moreover, low-count PET data at different institutions may have different data distribution, thus requiring personalized models. While previous federated learning (FL) algorithms enable multi-institution collaborative training without the need of aggregating local data, addressing the large domain shift in the application of multi-institutional low-count PET denoising remains a challenge and is still highly under-explored. In this work, we propose FedFTN, a personalized federated learning strategy that addresses these challenges. FedFTN uses a local deep feature transformation network (FTN) to modulate the feature outputs of a globally shared denoising network, enabling personalized low-count PET denoising for each institution. During the federated learning process, only the denoising network's weights are communicated and aggregated, while the FTN remains at the local institutions for feature transformation. We evaluated our method using a large-scale dataset of multi-institutional low-count PET imaging data from three medical centers located across three continents, and showed that FedFTN provides high-quality low-count PET images, outperforming previous baseline FL reconstruction methods across all low-count levels at all three institutions.
△ Less
Submitted 6 October, 2023; v1 submitted 2 April, 2023;
originally announced April 2023.