-
Hyperuniformity and non-hyperuniformity of zeros of Gaussian Weyl-Heisenberg Functions
Authors:
Naomi Feldheim,
Antti Haimi,
Günther Koliander,
José Luis Romero
Abstract:
We study zero sets of twisted stationary Gaussian random functions on the complex plane, i.e., Gaussian random functions that are stochastically invariant under the action of the Weyl-Heisenberg group. This model includes translation invariant Gaussian entire functions (GEFs), and also many other non-analytic examples, in which case winding numbers around zeros can be either positive or negative.…
▽ More
We study zero sets of twisted stationary Gaussian random functions on the complex plane, i.e., Gaussian random functions that are stochastically invariant under the action of the Weyl-Heisenberg group. This model includes translation invariant Gaussian entire functions (GEFs), and also many other non-analytic examples, in which case winding numbers around zeros can be either positive or negative. We investigate zero statistics both when zeros are weighted with their winding numbers (charged zero set) and when they are not (uncharged zero set).
We show that the variance of the charged zero statistic always grows linearly with the radius of the observation disk (hyperuniformity). Importantly, this holds for functions with possibly non-zero means and without assuming additional symmetries such as radiality. With respect to uncharged zero statistics, we provide an example for which the variance grows with the area of the observation disk (non-hyperuniformity). This is used to show that, while the zeros of GEFs are hyperuniform, the set of their critical points fails to be so.
Our work contributes to recent developments in statistical signal processing, where the time-frequency profile of a non-stationary signal embedded into noise is revealed by performing a statistical test on the zeros of its spectrogram (``silent points''). We show that empirical spectrogram zero counts enjoy moderate deviation from their ensemble averages over large observation windows (something that was previously known only for pure noise). In contrast, we also show that spectogram maxima (``loud points") fail to enjoy a similar property. This gives the first formal evidence for the statistical superiority of silent points over the competing feature of loud points, a fact that has been noted by practitioners.
△ Less
Submitted 28 June, 2024;
originally announced June 2024.
-
Novel Smart N95 Filtering Facepiece Respirator with Real-time Adaptive Fit Functionality and Wireless Humidity Monitoring for Enhanced Wearable Comfort
Authors:
Kangkyu Kwon,
Yoon Jae Lee,
Yeongju Jung,
Ira Soltis,
Chanyeong Choi,
Yewon Na,
Lissette Romero,
Myung Chul Kim,
Nathan Rodeheaver,
Hodam Kim,
Michael S. Lloyd,
Ziqing Zhuang,
William King,
Susan Xu,
Seung-Hwan Ko,
**woo Lee,
Woon-Hong Yeo
Abstract:
The widespread emergence of the COVID-19 pandemic has transformed our lifestyle, and facial respirators have become an essential part of daily life. Nevertheless, the current respirators possess several limitations such as poor respirator fit because they are incapable of covering diverse human facial sizes and shapes, potentially diminishing the effect of wearing respirators. In addition, the cur…
▽ More
The widespread emergence of the COVID-19 pandemic has transformed our lifestyle, and facial respirators have become an essential part of daily life. Nevertheless, the current respirators possess several limitations such as poor respirator fit because they are incapable of covering diverse human facial sizes and shapes, potentially diminishing the effect of wearing respirators. In addition, the current facial respirators do not inform the user of the air quality within the smart facepiece respirator in case of continuous long-term use. Here, we demonstrate the novel smart N-95 filtering facepiece respirator that incorporates the humidity sensor and pressure sensory feedback-enabled self-fit adjusting functionality for the effective performance of the facial respirator to prevent the transmission of airborne pathogens. The laser-induced graphene (LIG) constitutes the humidity sensor, and the pressure sensor array based on the dielectric elastomeric sponge monitors the respirator contact on the face of the user, providing the sensory information for a closed-loop feedback mechanism. As a result of the self-fit adjusting mode along with elastomeric lining, the fit factor is increased by 3.20 and 5 times at average and maximum respectively. We expect that the experimental proof-of-concept of this work will offer viable solutions to the current commercial respirators to address the limitations.
△ Less
Submitted 8 September, 2023;
originally announced September 2023.
-
Intelligent upper-limb exoskeleton integrated with soft wearable bioelectronics and deep-learning for human intention-driven strength augmentation based on sensory feedback
Authors:
**woo Lee,
Kangkyu Kwon,
Ira Soltis,
Jared Matthews,
Yoonjae Lee,
Hojoong Kim,
Lissette Romero,
Nathan Zavanelli,
Young** Kwon,
Shinjae Kwon,
Jimin Lee,
Yewon Na,
Sung Hoon Lee,
Ki Jun Yu,
Minoru Shinohara,
Frank L. Hammond,
Woon-Hong Yeo
Abstract:
The age and stroke-associated decline in musculoskeletal strength degrades the ability to perform daily human tasks using the upper extremities. Although there are a few examples of exoskeletons, they need manual operations due to the absence of sensor feedback and no intention prediction of movements. Here, we introduce an intelligent upper-limb exoskeleton system that uses cloud-based deep learn…
▽ More
The age and stroke-associated decline in musculoskeletal strength degrades the ability to perform daily human tasks using the upper extremities. Although there are a few examples of exoskeletons, they need manual operations due to the absence of sensor feedback and no intention prediction of movements. Here, we introduce an intelligent upper-limb exoskeleton system that uses cloud-based deep learning to predict human intention for strength augmentation. The embedded soft wearable sensors provide sensory feedback by collecting real-time muscle signals, which are simultaneously computed to determine the user's intended movement. The cloud-based deep-learning predicts four upper-limb joint motions with an average accuracy of 96.2% at a 200-250 millisecond response rate, suggesting that the exoskeleton operates just by human intention. In addition, an array of soft pneumatics assists the intended movements by providing 897 newton of force and 78.7 millimeter of displacement at maximum. Collectively, the intent-driven exoskeleton can augment human strength by 5.15 times on average compared to the unassisted exoskeleton. This report demonstrates an exoskeleton robot that augments the upper-limb joint movements by human intention based on a machine-learning cloud computing and sensory feedback.
△ Less
Submitted 26 January, 2024; v1 submitted 8 September, 2023;
originally announced September 2023.
-
COVID-VR: A Deep Learning COVID-19 Classification Model Using Volume-Rendered Computer Tomography
Authors:
Noemi Maritza L. Romero,
Ricco Vasconcellos,
Mariana R. Mendoza,
João L. D. Comba
Abstract:
The COVID-19 pandemic presented numerous challenges to healthcare systems worldwide. Given that lung infections are prevalent among COVID-19 patients, chest Computer Tomography (CT) scans have frequently been utilized as an alternative method for identifying COVID-19 conditions and various other types of pulmonary diseases. Deep learning architectures have emerged to automate the identification of…
▽ More
The COVID-19 pandemic presented numerous challenges to healthcare systems worldwide. Given that lung infections are prevalent among COVID-19 patients, chest Computer Tomography (CT) scans have frequently been utilized as an alternative method for identifying COVID-19 conditions and various other types of pulmonary diseases. Deep learning architectures have emerged to automate the identification of pulmonary disease types by leveraging CT scan slices as inputs for classification models. This paper introduces COVID-VR, a novel approach for classifying pulmonary diseases based on volume rendering images of the lungs captured from multiple angles, thereby providing a comprehensive view of the entire lung in each image. To assess the effectiveness of our proposal, we compared it against competing strategies utilizing both private data obtained from partner hospitals and a publicly available dataset. The results demonstrate that our approach effectively identifies pulmonary lesions and performs competitively when compared to slice-based methods.
△ Less
Submitted 2 August, 2023;
originally announced August 2023.
-
Corneal endothelium assessment in specular microscopy images with Fuchs' dystrophy via deep regression of signed distance maps
Authors:
Juan S. Sierra,
Jesus Pineda,
Daniela Rueda,
Alejandro Tello,
Angelica M. Prada,
Virgilio Galvis,
Giovanni Volpe,
Maria S. Millan,
Lenny A. Romero,
Andres G. Marrugo
Abstract:
Specular microscopy assessment of the human corneal endothelium (CE) in Fuchs' dystrophy is challenging due to the presence of dark image regions called guttae. This paper proposes a UNet-based segmentation approach that requires minimal post-processing and achieves reliable CE morphometric assessment and guttae identification across all degrees of Fuchs' dystrophy. We cast the segmentation proble…
▽ More
Specular microscopy assessment of the human corneal endothelium (CE) in Fuchs' dystrophy is challenging due to the presence of dark image regions called guttae. This paper proposes a UNet-based segmentation approach that requires minimal post-processing and achieves reliable CE morphometric assessment and guttae identification across all degrees of Fuchs' dystrophy. We cast the segmentation problem as a regression task of the cell and gutta signed distance maps instead of a pixel-level classification task as typically done with UNets. Compared to the conventional UNet classification approach, the distance-map regression approach converges faster in clinically relevant parameters. It also produces morphometric parameters that agree with the manually-segmented ground-truth data, namely the average cell density difference of -41.9 cells/mm2 (95% confidence interval (CI) [-306.2, 222.5]) and the average difference of mean cell area of 14.8 um2 (95% CI [-41.9, 71.5]). These results suggest a promising alternative for CE assessment.
△ Less
Submitted 29 November, 2022; v1 submitted 13 October, 2022;
originally announced October 2022.
-
Estimation of binary time-frequency masks from ambient noise
Authors:
José Luis Romero,
Michael Speckbacher
Abstract:
We investigate the retrieval of a binary time-frequency mask from a few observations of filtered white ambient noise. Confirming household wisdom in acoustic modeling, we show that this is possible by inspecting the average spectrogram of ambient noise. Specifically, we show that the lower quantile of the average of $\mathcal{O}(\log(|Ω|/\varepsilon))$ masked spectrograms is enough to identify a r…
▽ More
We investigate the retrieval of a binary time-frequency mask from a few observations of filtered white ambient noise. Confirming household wisdom in acoustic modeling, we show that this is possible by inspecting the average spectrogram of ambient noise. Specifically, we show that the lower quantile of the average of $\mathcal{O}(\log(|Ω|/\varepsilon))$ masked spectrograms is enough to identify a rather general mask $Ω$ with confidence at least $\varepsilon$, up to shape details concentrated near the boundary of $Ω$. As an application, the expected measure of the estimation error is dominated by the perimeter of the time-frequency mask. The estimator requires no knowledge of the noise variance, and only a very qualitative profile of the filtering window, but no exact knowledge of it.
△ Less
Submitted 2 February, 2024; v1 submitted 20 May, 2022;
originally announced May 2022.
-
Three-dimensional multimodal medical imaging system based on free-hand ultrasound and structured light
Authors:
Jhacson Meza,
Sonia H. Contreras-Ortiz,
Lenny A. Romero,
Andres G. Marrugo
Abstract:
We propose a three-dimensional (3D) multimodal medical imaging system that combines freehand ultrasound and structured light 3D reconstruction in a single coordinate system without requiring registration. To the best of our knowledge, these techniques have not been combined before as a multimodal imaging technique. The system complements the internal 3D information acquired with ultrasound, with t…
▽ More
We propose a three-dimensional (3D) multimodal medical imaging system that combines freehand ultrasound and structured light 3D reconstruction in a single coordinate system without requiring registration. To the best of our knowledge, these techniques have not been combined before as a multimodal imaging technique. The system complements the internal 3D information acquired with ultrasound, with the external surface measured with the structure light technique. Moreover, the ultrasound probe's optical tracking for pose estimation was implemented based on a convolutional neural network. Experimental results show the system's high accuracy and reproducibility, as well as its potential for preoperative and intraoperative applications. The experimental multimodal error, or the distance from two surfaces obtained with different modalities, was 0.12 mm. The code is available as a Github repository.
△ Less
Submitted 29 May, 2021;
originally announced May 2021.
-
Sampling the flow of a bandlimited function
Authors:
Akram Aldroubi,
Karlheinz Gröchenig,
Longxiu Huang,
Philippe Jaming,
Ilya Krishtal,
José Luis Romero
Abstract:
We analyze the problem of reconstruction of a bandlimited function $f$ from the space-time samples of its states $f_t=φ_t\ast f$ resulting from the convolution with a kernel $φ_t$. It is well-known that, in natural phenomena, uniform space-time samples of $f$ are not sufficient to reconstruct $f$ in a stable way. To enable stable reconstruction, a space-time sampling with periodic nonuniformly spa…
▽ More
We analyze the problem of reconstruction of a bandlimited function $f$ from the space-time samples of its states $f_t=φ_t\ast f$ resulting from the convolution with a kernel $φ_t$. It is well-known that, in natural phenomena, uniform space-time samples of $f$ are not sufficient to reconstruct $f$ in a stable way. To enable stable reconstruction, a space-time sampling with periodic nonuniformly spaced samples must be used as was shown by Lu and Vetterli. We show that the stability of reconstruction, as measured by a condition number, controls the maximal gap between the spacial samples. We provide a quantitative statement of this result. In addition, instead of irregular space-time samples, we show that uniform dynamical samples at sub-Nyquist spatial rate allow one to stably reconstruct the function $\widehat f$ away from certain, explicitly described blind spots. We also consider several classes of finite dimensional subsets of bandlimited functions in which the stable reconstruction is possible, even inside the blind spots. We obtain quantitative estimates for it using Remez-Turán type inequalities. En route, we obtain a Remez-Turán inequality for prolate spheroidal wave functions. To illustrate our results, we present some numerics and explicit estimates for the heat flow problem.
△ Less
Submitted 3 February, 2021; v1 submitted 29 April, 2020;
originally announced April 2020.
-
Hybrid calibration procedure for fringe projection profilometry based on stereo-vision and polynomial fitting
Authors:
Raul Vargas,
Andres G. Marrugo,
Song Zhang,
Lenny A. Romero
Abstract:
The key to accurate 3D shape measurement in Fringe Projection Profilometry (FPP) is the proper calibration of the measurement system. Current calibration techniques rely on phase-coordinate map** (PCM) or back-projection stereo-vision (SV) methods. PCM methods are cumbersome to implement as they require precise positioning of the calibration target relative to the FPP system but produce highly a…
▽ More
The key to accurate 3D shape measurement in Fringe Projection Profilometry (FPP) is the proper calibration of the measurement system. Current calibration techniques rely on phase-coordinate map** (PCM) or back-projection stereo-vision (SV) methods. PCM methods are cumbersome to implement as they require precise positioning of the calibration target relative to the FPP system but produce highly accurate measurements within the calibration volume. SV methods generally do not achieve the same accuracy level. However, the calibration is more flexible in that the calibration target can be arbitrarily positioned. In this work, we propose a hybrid calibration method that leverages the SV calibration approach using a PCM method to achieve higher accuracy. The method has the flexibility of SV methods, is robust to lens distortions, and has a simple relation between the recovered phase and the metric coordinates. Experimental results show that the proposed Hybrid method outperforms the SV method in terms of accuracy and reconstruction time due to its low computational complexity.
△ Less
Submitted 9 March, 2020;
originally announced March 2020.