Acceleration of Power System Dynamic Simulations using a Deep Equilibrium Layer and Neural ODE Surrogate
Authors:
Matthew Bossart,
Jose Daniel Lara,
Ciaran Roberts,
Rodrigo Henriquez-Auba,
Duncan Callaway,
Bri-Mathias Hodge
Abstract:
The dominant paradigm for power system dynamic simulation is to build system-level simulations by combining physics-based models of individual components. The sheer size of the system along with the rapid integration of inverter-based resources exacerbates the computational burden of running time domain simulations. In this paper, we propose a data-driven surrogate model based on implicit machine…
▽ More
The dominant paradigm for power system dynamic simulation is to build system-level simulations by combining physics-based models of individual components. The sheer size of the system along with the rapid integration of inverter-based resources exacerbates the computational burden of running time domain simulations. In this paper, we propose a data-driven surrogate model based on implicit machine learning -- specifically deep equilibrium layers and neural ordinary differential equations -- to learn a reduced order model of a portion of the full underlying system. The data-driven surrogate achieves similar accuracy and reduction in simulation time compared to a physics-based surrogate, without the constraint of requiring detailed knowledge of the underlying dynamic models. This work also establishes key requirements needed to integrate the surrogate into existing simulation workflows; the proposed surrogate is initialized to a steady state operating point that matches the power flow solution by design.
△ Less
Submitted 10 May, 2024;
originally announced May 2024.
-
Adaptive Control of Distributed Energy Resources for Distribution Grid Voltage Stability
Authors:
Daniel Arnold,
Shammya Saha,
Sy-Toan Ngo,
Ciaran Roberts,
Anna Scaglione,
Nathan Johnson,
Sean Peisert,
David Pinney
Abstract:
Volt-VAR and Volt-Watt functionality in photovoltaic (PV) smart inverters provide mechanisms to ensure system voltage magnitudes and power factors remain within acceptable limits. However, these control functions can become unstable, introducing oscillations in system voltages when not appropriately configured or maliciously altered during a cyberattack. In the event that Volt-VAR and Volt-Watt co…
▽ More
Volt-VAR and Volt-Watt functionality in photovoltaic (PV) smart inverters provide mechanisms to ensure system voltage magnitudes and power factors remain within acceptable limits. However, these control functions can become unstable, introducing oscillations in system voltages when not appropriately configured or maliciously altered during a cyberattack. In the event that Volt-VAR and Volt-Watt control functions in a portion of PV smart inverters in a distribution grid are unstable, the proposed adaptation scheme utilizes the remaining and stably-behaving PV smart inverters and other Distributed Energy Resources to mitigate the effect of the instability. The adaptation mechanism is entirely decentralized, model-free, communication-free, and requires virtually no external configuration. We provide a derivation of the adaptive control approach and validate the algorithm in experiments on the IEEE 37 and 8500 node test feeders.
△ Less
Submitted 10 February, 2022;
originally announced February 2022.
-
Adam-based Augmented Random Search for Control Policies for Distributed Energy Resource Cyber Attack Mitigation
Authors:
Daniel Arnold,
Sy-Toan Ngo,
Ciaran Roberts,
Yize Chen,
Anna Scaglione,
Sean Peisert
Abstract:
Volt-VAR and Volt-Watt control functions are mechanisms that are included in distributed energy resource (DER) power electronic inverters to mitigate excessively high or low voltages in distribution systems. In the event that a subset of DER have had their Volt-VAR and Volt-Watt settings compromised as part of a cyber-attack, we propose a mechanism to control the remaining set of non-compromised D…
▽ More
Volt-VAR and Volt-Watt control functions are mechanisms that are included in distributed energy resource (DER) power electronic inverters to mitigate excessively high or low voltages in distribution systems. In the event that a subset of DER have had their Volt-VAR and Volt-Watt settings compromised as part of a cyber-attack, we propose a mechanism to control the remaining set of non-compromised DER to ameliorate large oscillations in system voltages and large voltage imbalances in real time. To do so, we construct control policies for individual non-compromised DER, directly searching the policy space using an Adam-based augmented random search (ARS). In this paper we show that, compared to previous efforts aimed at training policies for DER cybersecurity using deep reinforcement learning (DRL), the proposed approach is able to learn optimal (and sometimes linear) policies an order of magnitude faster than conventional DRL techniques (e.g., Proximal Policy Optimization).
△ Less
Submitted 27 January, 2022;
originally announced January 2022.
-
Convex Optimization for Fuel Cell Hybrid Trains: Speed, Energy Management System, and Battery Thermals
Authors:
Rabee Jibrin,
Stuart Hillmansen,
Clive Roberts
Abstract:
We optimize the operation of a fuel cell hybrid train using convex optimization. The main objective is to minimize hydrogen fuel consumption for a target journey time while considering battery thermal constraints. The state trajectories: train speed, energy management system, and battery temperature, are all optimized concurrently within a single optimization problem. A novel thermal model is prop…
▽ More
We optimize the operation of a fuel cell hybrid train using convex optimization. The main objective is to minimize hydrogen fuel consumption for a target journey time while considering battery thermal constraints. The state trajectories: train speed, energy management system, and battery temperature, are all optimized concurrently within a single optimization problem. A novel thermal model is proposed in order to include battery temperature yet maintain formulation convexity. Simulations show fuel savings and better thermal management when temperature is optimized concurrently with the other states rather than sequentially -- separately afterwards. The fuel reduction is caused by reduced cooling effort which is motivated by the formulation's awareness of active cooling energy consumption. The benefit is more pronounced for warmer ambient temperatures that require more cooling.
△ Less
Submitted 17 November, 2021;
originally announced November 2021.
-
Mathematical Modeling for Holistic Convex Optimization of Hybrid Trains
Authors:
Rabee Jibrin,
Stuart Hillmansen,
Clive Roberts
Abstract:
We look into modeling fuel cell hybrid trains for the purpose of optimizing their operation using convex optimization. Models and constraints necessary to form a physically feasible yet convex problem are reviewed. This effort is described as holistic due to the broad consideration of train speed, energy management system, and battery thermals. The minimized objective is hydrogen fuel consumption…
▽ More
We look into modeling fuel cell hybrid trains for the purpose of optimizing their operation using convex optimization. Models and constraints necessary to form a physically feasible yet convex problem are reviewed. This effort is described as holistic due to the broad consideration of train speed, energy management system, and battery thermals. The minimized objective is hydrogen fuel consumption for a given target journey time. A novel battery thermal model is proposed to aid with battery thermal management and thus preserve battery lifetime. All models are derived in the space-domain which along constraint relaxations guarantee a convex optimization problem. First-principle knowledge and real-world data justify the suitableness of the proposed models for the intended optimization problem.
△ Less
Submitted 24 October, 2021;
originally announced October 2021.
-
Convex Optimization of Speed and Energy Management System for Fuel Cell Hybrid Trains
Authors:
Rabee Jibrin,
Stuart Hillmansen,
Clive Roberts,
Ning Zhao,
Zhongbei Tian
Abstract:
We look into minimizing the hydrogen fuel consumption of hydrogen hybrid trains by optimizing their operation. The powertrain considered is a fuel cell charge-sustaining hybrid. Convex optimization is utilized to compute optimal speed and energy management trajectories. The barrier method is used to solve the optimization problems quickly on the order of tens of seconds for the entire journey. Sim…
▽ More
We look into minimizing the hydrogen fuel consumption of hydrogen hybrid trains by optimizing their operation. The powertrain considered is a fuel cell charge-sustaining hybrid. Convex optimization is utilized to compute optimal speed and energy management trajectories. The barrier method is used to solve the optimization problems quickly on the order of tens of seconds for the entire journey. Simulations show a considerable reduction in fuel consumption when both trajectories -- speed and energy management -- are optimized concurrently within a single optimization problem in comparison to being optimized separately in a sequential manner -- optimizing energy management after optimizing speed. It is concluded that the concurrent method greatly benefits from its holistic powertrain knowledge while optimizing all trajectories together within a single optimization problem.
△ Less
Submitted 28 September, 2021;
originally announced September 2021.
-
Lyapunov Stability of Smart Inverters Using Linearized DistFlow Approximation
Authors:
Shammya Shananda Saha,
Daniel Arnold,
Anna Scaglione,
Eran Schweitzer,
Ciaran Roberts,
Sean Peisert,
Nathan G. Johnson
Abstract:
Fast-acting smart inverters that utilize preset operating conditions to determine real and reactive power injection/consumption can create voltage instabilities (over-voltage, voltage oscillations and more) in an electrical distribution network if set-points are not properly configured. In this work, linear distribution power flow equations and droop-based Volt-Var and Volt-Watt control curves are…
▽ More
Fast-acting smart inverters that utilize preset operating conditions to determine real and reactive power injection/consumption can create voltage instabilities (over-voltage, voltage oscillations and more) in an electrical distribution network if set-points are not properly configured. In this work, linear distribution power flow equations and droop-based Volt-Var and Volt-Watt control curves are used to analytically derive a stability criterion using \lyapnouv analysis that includes the network operating condition. The methodology is generally applicable for control curves that can be represented as Lipschitz functions. The derived Lipschitz constants account for smart inverter hardware limitations for reactive power generation. A local policy is derived from the stability criterion that allows inverters to adapt their control curves by monitoring only local voltage, thus avoiding centralized control or information sharing with other inverters. The criterion is independent of the internal time-delays of smart inverters. Simulation results for inverters with and without the proposed stabilization technique demonstrate how smart inverters can mitigate voltage oscillations locally and mitigate real and reactive power flow disturbances at the substation under multiple scenarios. The study concludes with illustrations of how the control policy can dampen oscillations caused by solar intermittency and cyber-attacks.
△ Less
Submitted 18 November, 2020;
originally announced November 2020.
-
Deep Reinforcement Learning for DER Cyber-Attack Mitigation
Authors:
Ciaran Roberts,
Sy-Toan Ngo,
Alexandre Milesi,
Sean Peisert,
Daniel Arnold,
Shammya Saha,
Anna Scaglione,
Nathan Johnson,
Anton Kocheturov,
Dmitriy Fradkin
Abstract:
The increasing penetration of DER with smart-inverter functionality is set to transform the electrical distribution network from a passive system, with fixed injection/consumption, to an active network with hundreds of distributed controllers dynamically modulating their operating setpoints as a function of system conditions. This transition is being achieved through standardization of functionali…
▽ More
The increasing penetration of DER with smart-inverter functionality is set to transform the electrical distribution network from a passive system, with fixed injection/consumption, to an active network with hundreds of distributed controllers dynamically modulating their operating setpoints as a function of system conditions. This transition is being achieved through standardization of functionality through grid codes and/or international standards. DER, however, are unique in that they are typically neither owned nor operated by distribution utilities and, therefore, represent a new emerging attack vector for cyber-physical attacks. Within this work we consider deep reinforcement learning as a tool to learn the optimal parameters for the control logic of a set of uncompromised DER units to actively mitigate the effects of a cyber-attack on a subset of network DER.
△ Less
Submitted 28 September, 2020;
originally announced September 2020.
-
Grid-Coupled Dynamic Response of Battery-Driven Voltage Source Converters
Authors:
Ciaran Roberts,
Jose Daniel Lara,
Rodrigo Henriquez-Auba,
Bala Kameshwar Poolla,
Duncan S. Callaway
Abstract:
With the increasing interest in converter-fed islanded microgrids, particularly for resilience, it is becoming more critical to understand the dynamical behavior of these systems. This paper takes a holistic view of grid-forming converters and considers control approaches for both modeling and regulating the DC-link voltage when the DC-source is a battery energy storage system. We are specifically…
▽ More
With the increasing interest in converter-fed islanded microgrids, particularly for resilience, it is becoming more critical to understand the dynamical behavior of these systems. This paper takes a holistic view of grid-forming converters and considers control approaches for both modeling and regulating the DC-link voltage when the DC-source is a battery energy storage system. We are specifically interested in understanding the performance of these controllers, subject to large load changes, for decreasing values of the DC-side capacitance. We consider a fourth, second, and zero-order model of the battery; and establish that the zero-order model captures the dynamics of interest for the timescales considered for disturbances examined. Additionally, we adapt a grid search for optimizing the controller parameters of the DC/DC controller and show how the inclusion of AC side measurements into the DC/DC controller can improve its dynamic performance. This improvement in performance offers the opportunity to reduce the DC-side capacitance given an admissible DC voltage transient deviation, thereby, potentially allowing for more reliable capacitor technology to be deployed.
△ Less
Submitted 28 July, 2020; v1 submitted 22 July, 2020;
originally announced July 2020.
-
LITS.jl -- An Open-Source Julia based Simulation Toolbox for Low-Inertia Power Systems
Authors:
Rodrigo Henriquez-Auba,
Jose D. Lara,
Ciaran Roberts,
Nathan Pallo,
Duncan S. Callaway
Abstract:
The integration of converter-interfaced generation (CIG) from renewable energy sources poses challenges to the stability and transient behavior of electric power systems. Understanding the dynamic behavior of low-inertia power systems is critical to addressing these stability questions. However, there is a limited availability of open source tools explicitly geared towards low-inertia systems mode…
▽ More
The integration of converter-interfaced generation (CIG) from renewable energy sources poses challenges to the stability and transient behavior of electric power systems. Understanding the dynamic behavior of low-inertia power systems is critical to addressing these stability questions. However, there is a limited availability of open source tools explicitly geared towards low-inertia systems modeling. In this paper, we develop an open source simulation toolbox to study transient responses under high penetration scenarios. LITS.jl is implemented in the Julia computing language and features multi-machine modeling capability, a rich library of synchronous generators components (AVR, PSS, Governor, etc.) and inverter configurations. Several case studies are conducted and benchmarked and validated against existing toolboxes. Case studies are selected to showcase the integration of different device models' behavior in power systems.
△ Less
Submitted 5 March, 2020;
originally announced March 2020.
-
Anomaly Detection Using Optimally-Placed Micro-PMU Sensors in Distribution Grids
Authors:
Mahdi Jamei,
Anna Scaglione,
Ciaran Roberts,
Emma Stewart,
Sean Peisert,
Chuck McParland,
Alex McEachern
Abstract:
As the distribution grid moves toward a tightly-monitored network, it is important to automate the analysis of the enormous amount of data produced by the sensors to increase the operators situational awareness about the system. In this paper, focusing on Micro-Phasor Measurement Unit ($μ$PMU) data, we propose a hierarchical architecture for monitoring the grid and establish a set of analytics and…
▽ More
As the distribution grid moves toward a tightly-monitored network, it is important to automate the analysis of the enormous amount of data produced by the sensors to increase the operators situational awareness about the system. In this paper, focusing on Micro-Phasor Measurement Unit ($μ$PMU) data, we propose a hierarchical architecture for monitoring the grid and establish a set of analytics and sensor fusion primitives for the detection of abnormal behavior in the control perimeter. Due to the key role of the $μ$PMU devices in our architecture, a source-constrained optimal $μ$PMU placement is also described that finds the best location of the devices with respect to our rules. The effectiveness of the proposed methods are tested through the synthetic and real $μ$PMU data.
△ Less
Submitted 31 July, 2017;
originally announced August 2017.
-
Automated Anomaly Detection in Distribution Grids Using $μ$PMU Measurements
Authors:
Mahdi Jamei,
Anna Scaglione,
Ciaran Roberts,
Emma Stewart,
Sean Peisert,
Chuck McParland,
Alex McEachern
Abstract:
The impact of Phasor Measurement Units (PMUs) for providing situational awareness to transmission system operators has been widely documented. Micro-PMUs ($μ$PMUs) are an emerging sensing technology that can provide similar benefits to Distribution System Operators (DSOs), enabling a level of visibility into the distribution grid that was previously unattainable. In order to support the deployment…
▽ More
The impact of Phasor Measurement Units (PMUs) for providing situational awareness to transmission system operators has been widely documented. Micro-PMUs ($μ$PMUs) are an emerging sensing technology that can provide similar benefits to Distribution System Operators (DSOs), enabling a level of visibility into the distribution grid that was previously unattainable. In order to support the deployment of these high resolution sensors, the automation of data analysis and prioritizing communication to the DSO becomes crucial. In this paper, we explore the use of $μ$PMUs to detect anomalies on the distribution grid. Our methodology is motivated by growing concern about failures and attacks to distribution automation equipment. The effectiveness of our approach is demonstrated through both real and simulated data.
△ Less
Submitted 30 September, 2016;
originally announced October 2016.
-
Towards Real-Time Estimation of Solar Generation From Micro-Synchrophasor Measurements
Authors:
Emre C. Kara,
Ciaran M. Roberts,
Michaelangelo Tabone,
Lilliana Alvarez,
Duncan S. Callaway,
Emma M. Stewart
Abstract:
This paper presents a set of methods for estimating the renewable energy generation downstream of a measurement device using real-world measurements. First, we present a generation disaggregation scheme where the only information available for estimation is the micro-synchrophasor measurements obtained at the substation or feeder head. We then propose two strategies in which we use measurements fr…
▽ More
This paper presents a set of methods for estimating the renewable energy generation downstream of a measurement device using real-world measurements. First, we present a generation disaggregation scheme where the only information available for estimation is the micro-synchrophasor measurements obtained at the substation or feeder head. We then propose two strategies in which we use measurements from the substation as well as a proxy solar irradiance measurement. Using these two measurement points, we first propose a multiple linear regression strategy, in which we estimate a relationship between the measured reactive power and the load active power consumption, which are then used in disaggregation. Finally, we expand this strategy to strategically manage the reconstruction errors in the estimators. We simultaneously disaggregate the solar generation and load. We show that it is possible to disaggragate the generation of a 7.5 megawatt photovoltaic site with a root-mean-squared error of approximately 450 kilowatts.
△ Less
Submitted 13 July, 2016; v1 submitted 11 July, 2016;
originally announced July 2016.