An AI tool for automated analysis of large-scale unstructured clinical cine CMR databases
Authors:
Jorge Mariscal-Harana,
Clint Asher,
Vittoria Vergani,
Maleeha Rizvi,
Louise Keehn,
Raymond J. Kim,
Robert M. Judd,
Steffen E. Petersen,
Reza Razavi,
Andrew King,
Bram Ruijsink,
Esther Puyol-Antón
Abstract:
Artificial intelligence (AI) techniques have been proposed for automating analysis of short axis (SAX) cine cardiac magnetic resonance (CMR), but no CMR analysis tool exists to automatically analyse large (unstructured) clinical CMR datasets. We develop and validate a robust AI tool for start-to-end automatic quantification of cardiac function from SAX cine CMR in large clinical databases. Our pip…
▽ More
Artificial intelligence (AI) techniques have been proposed for automating analysis of short axis (SAX) cine cardiac magnetic resonance (CMR), but no CMR analysis tool exists to automatically analyse large (unstructured) clinical CMR datasets. We develop and validate a robust AI tool for start-to-end automatic quantification of cardiac function from SAX cine CMR in large clinical databases. Our pipeline for processing and analysing CMR databases includes automated steps to identify the correct data, robust image pre-processing, an AI algorithm for biventricular segmentation of SAX CMR and estimation of functional biomarkers, and automated post-analysis quality control to detect and correct errors. The segmentation algorithm was trained on 2793 CMR scans from two NHS hospitals and validated on additional cases from this dataset (n=414) and five external datasets (n=6888), including scans of patients with a range of diseases acquired at 12 different centres using CMR scanners from all major vendors. Median absolute errors in cardiac biomarkers were within the range of inter-observer variability: <8.4mL (left ventricle volume), <9.2mL (right ventricle volume), <13.3g (left ventricular mass), and <5.9% (ejection fraction) across all datasets. Stratification of cases according to phenotypes of cardiac disease and scanner vendors showed good performance across all groups. We show that our proposed tool, which combines image pre-processing steps, a domain-generalisable AI algorithm trained on a large-scale multi-domain CMR dataset and quality control steps, allows robust analysis of (clinical or research) databases from multiple centres, vendors, and cardiac diseases. This enables translation of our tool for use in fully-automated processing of large multi-centre databases.
△ Less
Submitted 5 July, 2023; v1 submitted 15 June, 2022;
originally announced June 2022.
Hybrid Voltage Stability and Security Assessment using Synchrophasors with Consideration of Generator Q-limits
Authors:
Syed Muhammad Hur Rizvi,
Pratim Kundu,
Anurag K. Srivastava
Abstract:
Increased power demands, push for economics and limited investment in grid infrastructure have led utilities to operatepower systems closer to their stability limits. Voltage instability may trigger cascade trip**, wide-area voltage collapse and powerblackouts. Real-time voltage stability monitoring possible with deployment of phasor measurement units (PMUs) is essential totake proactive control…
▽ More
Increased power demands, push for economics and limited investment in grid infrastructure have led utilities to operatepower systems closer to their stability limits. Voltage instability may trigger cascade trip**, wide-area voltage collapse and powerblackouts. Real-time voltage stability monitoring possible with deployment of phasor measurement units (PMUs) is essential totake proactive control actions and minimize the impact on system. This paper presents a novel online algorithm for a) hybridperturbation analysis-based voltage stability monitoring (HPVSM), b) including Q-limit in voltage stability index and c) real timesecurity analysis using voltage stability index. HPVSM based voltage stability index is computed using the data obtained fromlinear state estimator and PMU measurements. Typically measurement-based schemes ignore the impact of generator Q-limitsand security analysis is not feasible. The proposed HPVSM based index considers the impact of generator Q-limits violationsby anticipating the critical generators using real-time PMU measurements. Contingencies are ranked using the proposed voltagestability index for security analysis. Results simulated for the 9-bus WECC, IEEE 14, 57 and 118 bus systems highlights thesuperiority of the proposed method in real time voltage stability and security analysis
△ Less
Submitted 27 May, 2020;
originally announced May 2020.