-
TotalVibeSegmentator: Full Torso Segmentation for the NAKO and UK Biobank in Volumetric Interpolated Breath-hold Examination Body Images
Authors:
Robert Graf,
Paul-Sören Platzek,
Evamaria Olga Riedel,
Constanze Ramschütz,
Sophie Starck,
Hendrik Kristian Möller,
Matan Atad,
Henry Völzke,
Robin Bülow,
Carsten Oliver Schmidt,
Julia Rüdebusch,
Matthias Jung,
Marco Reisert,
Jakob Weiss,
Maximilian Löffler,
Fabian Bamberg,
Bene Wiestler,
Johannes C. Paetzold,
Daniel Rueckert,
Jan Stefan Kirschke
Abstract:
Objectives: To present a publicly available torso segmentation network for large epidemiology datasets on volumetric interpolated breath-hold examination (VIBE) images. Materials & Methods: We extracted preliminary segmentations from TotalSegmentator, spine, and body composition networks for VIBE images, then improved them iteratively and retrained a nnUNet network. Using subsets of NAKO (85 subje…
▽ More
Objectives: To present a publicly available torso segmentation network for large epidemiology datasets on volumetric interpolated breath-hold examination (VIBE) images. Materials & Methods: We extracted preliminary segmentations from TotalSegmentator, spine, and body composition networks for VIBE images, then improved them iteratively and retrained a nnUNet network. Using subsets of NAKO (85 subjects) and UK Biobank (16 subjects), we evaluated with Dice-score on a holdout set (12 subjects) and existing organ segmentation approach (1000 subjects), generating 71 semantic segmentation types for VIBE images. We provide an additional network for the vertebra segments 22 individual vertebra types. Results: We achieved an average Dice score of 0.89 +- 0.07 overall 71 segmentation labels. We scored > 0.90 Dice-score on the abdominal organs except for the pancreas with a Dice of 0.70. Conclusion: Our work offers a detailed and refined publicly available full torso segmentation on VIBE images.
△ Less
Submitted 31 May, 2024;
originally announced June 2024.
-
TotalSegmentator MRI: Sequence-Independent Segmentation of 59 Anatomical Structures in MR images
Authors:
Tugba Akinci D'Antonoli,
Lucas K. Berger,
Ashraya K. Indrakanti,
Nathan Vishwanathan,
Jakob Weiß,
Matthias Jung,
Zeynep Berkarda,
Alexander Rau,
Marco Reisert,
Thomas Küstner,
Alexandra Walter,
Elmar M. Merkle,
Martin Segeroth,
Joshy Cyriac,
Shan Yang,
Jakob Wasserthal
Abstract:
Purpose: To develop an open-source and easy-to-use segmentation model that can automatically and robustly segment most major anatomical structures in MR images independently of the MR sequence.
Materials and Methods: In this study we extended the capabilities of TotalSegmentator to MR images. 298 MR scans and 227 CT scans were used to segment 59 anatomical structures (20 organs, 18 bones, 11 mus…
▽ More
Purpose: To develop an open-source and easy-to-use segmentation model that can automatically and robustly segment most major anatomical structures in MR images independently of the MR sequence.
Materials and Methods: In this study we extended the capabilities of TotalSegmentator to MR images. 298 MR scans and 227 CT scans were used to segment 59 anatomical structures (20 organs, 18 bones, 11 muscles, 7 vessels, 3 tissue types) relevant for use cases such as organ volumetry, disease characterization, and surgical planning. The MR and CT images were randomly sampled from routine clinical studies and thus represent a real-world dataset (different ages, pathologies, scanners, body parts, sequences, contrasts, echo times, repetition times, field strengths, slice thicknesses and sites). We trained an nnU-Net segmentation algorithm on this dataset and calculated Dice similarity coefficients (Dice) to evaluate the model's performance.
Results: The model showed a Dice score of 0.824 (CI: 0.801, 0.842) on the test set, which included a wide range of clinical data with major pathologies. The model significantly outperformed two other publicly available segmentation models (Dice score, 0.824 versus 0.762; p<0.001 and 0.762 versus 0.542; p<0.001). On the CT image test set of the original TotalSegmentator paper it almost matches the performance of the original TotalSegmentator (Dice score, 0.960 versus 0.970; p<0.001).
Conclusion: Our proposed model extends the capabilities of TotalSegmentator to MR images. The annotated dataset (https://zenodo.org/doi/10.5281/zenodo.11367004) and open-source toolkit (https://www.github.com/wasserth/TotalSegmentator) are publicly available.
△ Less
Submitted 29 May, 2024;
originally announced May 2024.
-
Optimization and Validation of Diffusion MRI-based Fiber Tracking with Neural Tracer Data as a Reference
Authors:
Carlos Enrique Gutierrez,
Henrik Skibbe,
Ken Nakae,
Hiromichi Tsukada,
Jean Lienard,
Akiya Watakabe,
Junichi Hata,
Marco Reisert,
Alexander Woodward,
Hideyuki Okano,
Tetsuo Yamamori,
Yoko Yamaguchi,
Shin Ishii,
Kenji Doya
Abstract:
Diffusion-weighted magnetic resonance imaging (dMRI) allows non-invasive investigation of whole-brain connectivity, which can potentially help to reveal the brain's global network architecture and abnormalities involved in neurological and mental disorders. However, the reliability of connection inferences from dMRI-based fiber tracking is still debated, due to low sensitivity, dominance of false…
▽ More
Diffusion-weighted magnetic resonance imaging (dMRI) allows non-invasive investigation of whole-brain connectivity, which can potentially help to reveal the brain's global network architecture and abnormalities involved in neurological and mental disorders. However, the reliability of connection inferences from dMRI-based fiber tracking is still debated, due to low sensitivity, dominance of false positives, and inaccurate and incomplete reconstruction of long-range connections. Furthermore, parameters of tracking algorithms are typically tuned in a heuristic way, which leaves room for manipulation of an intended result. Here we propose a data-driven framework to optimize and validate parameters of dMRI-based fiber-tracking algorithms using neural tracer data as a reference. Japan's Brain/MINDS Project provides invaluable datasets containing both dMRI and neural tracer data from the same primates. We considered four criteria for goodness of fiber tracking: distance-weighted coverage, true/false positive ratio, projection coincidence, and commissural passage, applied using a multi-objective optimization algorithm. We implemented a variant of non-dominated sorting genetic algorithm II (NSGA-II) to optimize five major parameters of a global fiber-tracking algorithm over multiple brain samples in parallel. Using optimized parameters compared to the default parameters, dMRI-based fiber tracking performance was significantly improved, while minimizing false positives and impossible cross-hemisphere connections. Parameters optimized for 10 tracer injection sites showed good generalization capability for other brain samples. These results demonstrate the importance of data-driven adjustment of fiber-tracking algorithms and support the validity of dMRI-based tractography, if appropriate adjustments are employed.
△ Less
Submitted 24 April, 2020; v1 submitted 27 November, 2019;
originally announced November 2019.