-
CMRxRecon2024: A Multi-Modality, Multi-View K-Space Dataset Boosting Universal Machine Learning for Accelerated Cardiac MRI
Authors:
Zi Wang,
Fanwen Wang,
Chen Qin,
Jun Lyu,
Ouyang Cheng,
Shuo Wang,
Yan Li,
Mengyao Yu,
Haoyu Zhang,
Kunyuan Guo,
Zhang Shi,
Qirong Li,
Ziqiang Xu,
Ya**g Zhang,
Hao Li,
Sha Hua,
Binghua Chen,
Longyu Sun,
Mengting Sun,
Qin Li,
Ying-Hua Chu,
Wenjia Bai,
**g Qin,
Xiahai Zhuang,
Claudia Prieto
, et al. (7 additional authors not shown)
Abstract:
Cardiac magnetic resonance imaging (MRI) has emerged as a clinically gold-standard technique for diagnosing cardiac diseases, thanks to its ability to provide diverse information with multiple modalities and anatomical views. Accelerated cardiac MRI is highly expected to achieve time-efficient and patient-friendly imaging, and then advanced image reconstruction approaches are required to recover h…
▽ More
Cardiac magnetic resonance imaging (MRI) has emerged as a clinically gold-standard technique for diagnosing cardiac diseases, thanks to its ability to provide diverse information with multiple modalities and anatomical views. Accelerated cardiac MRI is highly expected to achieve time-efficient and patient-friendly imaging, and then advanced image reconstruction approaches are required to recover high-quality, clinically interpretable images from undersampled measurements. However, the lack of publicly available cardiac MRI k-space dataset in terms of both quantity and diversity has severely hindered substantial technological progress, particularly for data-driven artificial intelligence. Here, we provide a standardized, diverse, and high-quality CMRxRecon2024 dataset to facilitate the technical development, fair evaluation, and clinical transfer of cardiac MRI reconstruction approaches, towards promoting the universal frameworks that enable fast and robust reconstructions across different cardiac MRI protocols in clinical practice. To the best of our knowledge, the CMRxRecon2024 dataset is the largest and most diverse publicly available cardiac k-space dataset. It is acquired from 330 healthy volunteers, covering commonly used modalities, anatomical views, and acquisition trajectories in clinical cardiac MRI workflows. Besides, an open platform with tutorials, benchmarks, and data processing tools is provided to facilitate data usage, advanced method development, and fair performance evaluation.
△ Less
Submitted 27 June, 2024;
originally announced June 2024.
-
Self-Supervised k-Space Regularization for Motion-Resolved Abdominal MRI Using Neural Implicit k-Space Representation
Authors:
Veronika Spieker,
Hannah Eichhorn,
Jonathan K. Stelter,
Wenqi Huang,
Rickmer F. Braren,
Daniel Rückert,
Francisco Sahli Costabal,
Kerstin Hammernik,
Claudia Prieto,
Dimitrios C. Karampinos,
Julia A. Schnabel
Abstract:
Neural implicit k-space representations have shown promising results for dynamic MRI at high temporal resolutions. Yet, their exclusive training in k-space limits the application of common image regularization methods to improve the final reconstruction. In this work, we introduce the concept of parallel imaging-inspired self-consistency (PISCO), which we incorporate as novel self-supervised k-spa…
▽ More
Neural implicit k-space representations have shown promising results for dynamic MRI at high temporal resolutions. Yet, their exclusive training in k-space limits the application of common image regularization methods to improve the final reconstruction. In this work, we introduce the concept of parallel imaging-inspired self-consistency (PISCO), which we incorporate as novel self-supervised k-space regularization enforcing a consistent neighborhood relationship. At no additional data cost, the proposed regularization significantly improves neural implicit k-space reconstructions on simulated data. Abdominal in-vivo reconstructions using PISCO result in enhanced spatio-temporal image quality compared to state-of-the-art methods. Code is available at https://github.com/vjspi/PISCO-NIK.
△ Less
Submitted 12 April, 2024;
originally announced April 2024.
-
Unsupervised reconstruction of accelerated cardiac cine MRI using Neural Fields
Authors:
Tabita Catalán,
Matías Courdurier,
Axel Osses,
René Botnar,
Francisco Sahli Costabal,
Claudia Prieto
Abstract:
Cardiac cine MRI is the gold standard for cardiac functional assessment, but the inherently slow acquisition process creates the necessity of reconstruction approaches for accelerated undersampled acquisitions. Several regularization approaches that exploit spatial-temporal redundancy have been proposed to reconstruct undersampled cardiac cine MRI. More recently, methods based on supervised deep l…
▽ More
Cardiac cine MRI is the gold standard for cardiac functional assessment, but the inherently slow acquisition process creates the necessity of reconstruction approaches for accelerated undersampled acquisitions. Several regularization approaches that exploit spatial-temporal redundancy have been proposed to reconstruct undersampled cardiac cine MRI. More recently, methods based on supervised deep learning have been also proposed to further accelerate acquisition and reconstruction. However, these techniques rely on usually large dataset for training, which are not always available. In this work, we propose an unsupervised approach based on implicit neural field representations for cardiac cine MRI (so called NF-cMRI). The proposed method was evaluated in in-vivo undersampled golden-angle radial multi-coil acquisitions for undersampling factors of 26x and 52x, achieving good image quality, and comparable spatial and improved temporal depiction than a state-of-the-art reconstruction technique.
△ Less
Submitted 24 July, 2023;
originally announced July 2023.
-
Innovative use of X-ray radiography in the study of daguerreotypes: identification of hallmarks
Authors:
Sara Barrio,
Laura Alba,
Clara M. Prieto
Abstract:
X-ray radiography is an imaging technique widely used in the examination of works of art and heritage objects, however no references to its application to the study of daguerreotypes have been found. The results obtained in this study demonstrate for the first time the usefulness of X-ray radiography for locating, identifying, and characterizing the hallmarks on the daguerreotype plates. Hallmarks…
▽ More
X-ray radiography is an imaging technique widely used in the examination of works of art and heritage objects, however no references to its application to the study of daguerreotypes have been found. The results obtained in this study demonstrate for the first time the usefulness of X-ray radiography for locating, identifying, and characterizing the hallmarks on the daguerreotype plates. Hallmarks are of great importance for the knowledge of these photographic objects since they provide unique information for their dating. In this study five daguerreotypes were X-rayed using two different working procedures designed with the aim of recording the hallmarks, one by means of radiographic film and the other using a digital detector. The working procedures presented here not only enabled locating the hallmarks of all daguerreotypes studied, but also allowed its positive identification without extracting the daguerrean package or handling the plate, avoiding its exposure to damaging environmental factors. X-ray radiography is thus revealed as an innovative and easy to integrate tool for the study of daguerreotypes, both for the characterization of hallmarks on the plate and the analysis of other elements and manufacturing procedures.
△ Less
Submitted 27 April, 2023;
originally announced July 2023.
-
Multi-view Attention for gestational age at birth prediction
Authors:
Mathieu Leclercq,
Martin Styner,
Juan Carlos Prieto
Abstract:
We present our method for gestational age at birth prediction for the SLCN (surface learning for clinical neuroimaging) challenge. Our method is based on a multi-view shape analysis technique that captures 2D renderings of a 3D object from different viewpoints. We render the brain features on the surface of the sphere and then the 2D images are analyzed via 2D CNNs and an attention layer for the r…
▽ More
We present our method for gestational age at birth prediction for the SLCN (surface learning for clinical neuroimaging) challenge. Our method is based on a multi-view shape analysis technique that captures 2D renderings of a 3D object from different viewpoints. We render the brain features on the surface of the sphere and then the 2D images are analyzed via 2D CNNs and an attention layer for the regression task. The regression task achieves a MAE of 1.637 +- 1.3 on the Native space and MAE of 1.38 +- 1.14 on the template space. The source code for this project is available in our github repository https://github.com/MathieuLeclercq/SLCN_challenge_UNC
△ Less
Submitted 8 July, 2022;
originally announced July 2022.
-
A Deep Learning-based Integrated Framework for Quality-aware Undersampled Cine Cardiac MRI Reconstruction and Analysis
Authors:
Inês P. Machado,
Esther Puyol-Antón,
Kerstin Hammernik,
Gastão Cruz,
Devran Ugurlu,
Ihsane Olakorede,
Ilkay Oksuz,
Bram Ruijsink,
Miguel Castelo-Branco,
Alistair A. Young,
Claudia Prieto,
Julia A. Schnabel,
Andrew P. King
Abstract:
Cine cardiac magnetic resonance (CMR) imaging is considered the gold standard for cardiac function evaluation. However, cine CMR acquisition is inherently slow and in recent decades considerable effort has been put into accelerating scan times without compromising image quality or the accuracy of derived results. In this paper, we present a fully-automated, quality-controlled integrated framework…
▽ More
Cine cardiac magnetic resonance (CMR) imaging is considered the gold standard for cardiac function evaluation. However, cine CMR acquisition is inherently slow and in recent decades considerable effort has been put into accelerating scan times without compromising image quality or the accuracy of derived results. In this paper, we present a fully-automated, quality-controlled integrated framework for reconstruction, segmentation and downstream analysis of undersampled cine CMR data. The framework enables active acquisition of radial k-space data, in which acquisition can be stopped as soon as acquired data are sufficient to produce high quality reconstructions and segmentations. This results in reduced scan times and automated analysis, enabling robust and accurate estimation of functional biomarkers. To demonstrate the feasibility of the proposed approach, we perform realistic simulations of radial k-space acquisitions on a dataset of subjects from the UK Biobank and present results on in-vivo cine CMR k-space data collected from healthy subjects. The results demonstrate that our method can produce quality-controlled images in a mean scan time reduced from 12 to 4 seconds per slice, and that image quality is sufficient to allow clinically relevant parameters to be automatically estimated to within 5% mean absolute difference.
△ Less
Submitted 2 May, 2022;
originally announced May 2022.
-
Quality-aware Cine Cardiac MRI Reconstruction and Analysis from Undersampled k-space Data
Authors:
Ines Machado,
Esther Puyol-Anton,
Kerstin Hammernik,
Gastao Cruz,
Devran Ugurlu,
Bram Ruijsink,
Miguel Castelo-Branco,
Alistair Young,
Claudia Prieto,
Julia A. Schnabel,
Andrew P. King
Abstract:
Cine cardiac MRI is routinely acquired for the assessment of cardiac health, but the imaging process is slow and typically requires several breath-holds to acquire sufficient k-space profiles to ensure good image quality. Several undersampling-based reconstruction techniques have been proposed during the last decades to speed up cine cardiac MRI acquisition. However, the undersampling factor is co…
▽ More
Cine cardiac MRI is routinely acquired for the assessment of cardiac health, but the imaging process is slow and typically requires several breath-holds to acquire sufficient k-space profiles to ensure good image quality. Several undersampling-based reconstruction techniques have been proposed during the last decades to speed up cine cardiac MRI acquisition. However, the undersampling factor is commonly fixed to conservative values before acquisition to ensure diagnostic image quality, potentially leading to unnecessarily long scan times. In this paper, we propose an end-to-end quality-aware cine short-axis cardiac MRI framework that combines image acquisition and reconstruction with downstream tasks such as segmentation, volume curve analysis and estimation of cardiac functional parameters. The goal is to reduce scan time by acquiring only a fraction of k-space data to enable the reconstruction of images that can pass quality control checks and produce reliable estimates of cardiac functional parameters. The framework consists of a deep learning model for the reconstruction of 2D+t cardiac cine MRI images from undersampled data, an image quality-control step to detect good quality reconstructions, followed by a deep learning model for bi-ventricular segmentation, a quality-control step to detect good quality segmentations and automated calculation of cardiac functional parameters. To demonstrate the feasibility of the proposed approach, we perform simulations using a cohort of selected participants from the UK Biobank (n=270), 200 healthy subjects and 70 patients with cardiomyopathies. Our results show that we can produce quality-controlled images in a scan time reduced from 12 to 4 seconds per slice, enabling reliable estimates of cardiac functional parameters such as ejection fraction within 5% mean absolute error.
△ Less
Submitted 16 September, 2021;
originally announced September 2021.
-
LAPNet: Non-rigid Registration derived in k-space for Magnetic Resonance Imaging
Authors:
Thomas Küstner,
Jiazhen Pan,
Haikun Qi,
Gastao Cruz,
Christopher Gilliam,
Thierry Blu,
Bin Yang,
Sergios Gatidis,
René Botnar,
Claudia Prieto
Abstract:
Physiological motion, such as cardiac and respiratory motion, during Magnetic Resonance (MR) image acquisition can cause image artifacts. Motion correction techniques have been proposed to compensate for these types of motion during thoracic scans, relying on accurate motion estimation from undersampled motion-resolved reconstruction. A particular interest and challenge lie in the derivation of re…
▽ More
Physiological motion, such as cardiac and respiratory motion, during Magnetic Resonance (MR) image acquisition can cause image artifacts. Motion correction techniques have been proposed to compensate for these types of motion during thoracic scans, relying on accurate motion estimation from undersampled motion-resolved reconstruction. A particular interest and challenge lie in the derivation of reliable non-rigid motion fields from the undersampled motion-resolved data. Motion estimation is usually formulated in image space via diffusion, parametric-spline, or optical flow methods. However, image-based registration can be impaired by remaining aliasing artifacts due to the undersampled motion-resolved reconstruction. In this work, we describe a formalism to perform non-rigid registration directly in the sampled Fourier space, i.e. k-space. We propose a deep-learning based approach to perform fast and accurate non-rigid registration from the undersampled k-space data. The basic working principle originates from the Local All-Pass (LAP) technique, a recently introduced optical flow-based registration. The proposed LAPNet is compared against traditional and deep learning image-based registrations and tested on fully-sampled and highly-accelerated (with two undersampling strategies) 3D respiratory motion-resolved MR images in a cohort of 40 patients with suspected liver or lung metastases and 25 healthy subjects. The proposed LAPNet provided consistent and superior performance to image-based approaches throughout different sampling trajectories and acceleration factors.
△ Less
Submitted 19 July, 2021;
originally announced July 2021.
-
Magnetization Transfer-Mediated MR Fingerprinting
Authors:
Daniel J. West,
Gastao Cruz,
Rui P. A. G. Teixeira,
Torben Schneider,
Jacques-Donald Tournier,
Joseph V. Hajnal,
Claudia Prieto,
Shaihan J. Malik
Abstract:
Purpose: Magnetization transfer (MT) and inhomogeneous MT (ihMT) contrasts are used in MRI to provide information about macromolecular tissue content. In particular, MT is sensitive to macromolecules and ihMT appears to be specific to myelinated tissue. This study proposes a technique to characterize MT and ihMT properties from a single acquisition, producing both semiquantitative contrast ratios,…
▽ More
Purpose: Magnetization transfer (MT) and inhomogeneous MT (ihMT) contrasts are used in MRI to provide information about macromolecular tissue content. In particular, MT is sensitive to macromolecules and ihMT appears to be specific to myelinated tissue. This study proposes a technique to characterize MT and ihMT properties from a single acquisition, producing both semiquantitative contrast ratios, and quantitative parameter maps.
Theory and Methods: Building upon previous work that uses multiband radiofrequency (RF) pulses to efficiently generate ihMT contrast, we propose a cyclic-steady-state approach that cycles between multiband and single-band pulses to boost the achieved contrast. Resultant time-variable signals are reminiscent of a magnetic resonance fingerprinting (MRF) acquisition, except that the signal fluctuations are entirely mediated by magnetization transfer effects. A dictionary-based low-rank inversion method is used to reconstruct the resulting images and to produce both semiquantitative MT ratio (MTR) and ihMT ratio (ihMTR) maps, as well as quantitative parameter estimates corresponding to an ihMT tissue model.
Results: Phantom and in vivo brain data acquired at 1.5T demonstrate the expected contrast trends, with ihMTR maps showing contrast more specific to white matter (WM), as has been reported by others. Quantitative estimation of semisolid fraction and dipolar T1 was also possible and yielded measurements consistent with literature values in the brain.
Conclusions: By cycling between multiband and single-band pulses, an entirely magnetization transfer mediated 'fingerprinting' method was demonstrated. This proof-of-concept approach can be used to generate semiquantitative maps and quantitatively estimate some macromolecular specific tissue parameters.
△ Less
Submitted 23 August, 2021; v1 submitted 6 April, 2021;
originally announced April 2021.
-
Complementary Time-Frequency Domain Networks for Dynamic Parallel MR Image Reconstruction
Authors:
Chen Qin,
**ming Duan,
Kerstin Hammernik,
Jo Schlemper,
Thomas Küstner,
René Botnar,
Claudia Prieto,
Anthony N. Price,
Joseph V. Hajnal,
Daniel Rueckert
Abstract:
Purpose: To introduce a novel deep learning based approach for fast and high-quality dynamic multi-coil MR reconstruction by learning a complementary time-frequency domain network that exploits spatio-temporal correlations simultaneously from complementary domains.
Theory and Methods: Dynamic parallel MR image reconstruction is formulated as a multi-variable minimisation problem, where the data…
▽ More
Purpose: To introduce a novel deep learning based approach for fast and high-quality dynamic multi-coil MR reconstruction by learning a complementary time-frequency domain network that exploits spatio-temporal correlations simultaneously from complementary domains.
Theory and Methods: Dynamic parallel MR image reconstruction is formulated as a multi-variable minimisation problem, where the data is regularised in combined temporal Fourier and spatial (x-f) domain as well as in spatio-temporal image (x-t) domain. An iterative algorithm based on variable splitting technique is derived, which alternates among signal de-aliasing steps in x-f and x-t spaces, a closed-form point-wise data consistency step and a weighted coupling step. The iterative model is embedded into a deep recurrent neural network which learns to recover the image via exploiting spatio-temporal redundancies in complementary domains.
Results: Experiments were performed on two datasets of highly undersampled multi-coil short-axis cardiac cine MRI scans. Results demonstrate that our proposed method outperforms the current state-of-the-art approaches both quantitatively and qualitatively. The proposed model can also generalise well to data acquired from a different scanner and data with pathologies that were not seen in the training set.
Conclusion: The work shows the benefit of reconstructing dynamic parallel MRI in complementary time-frequency domains with deep neural networks. The method can effectively and robustly reconstruct high-quality images from highly undersampled dynamic multi-coil data ($16 \times$ and $24 \times$ yielding 15s and 10s scan times respectively) with fast reconstruction speed (2.8s). This could potentially facilitate achieving fast single-breath-hold clinical 2D cardiac cine imaging.
△ Less
Submitted 18 June, 2021; v1 submitted 22 December, 2020;
originally announced December 2020.
-
Channel Attention Networks for Robust MR Fingerprinting Matching
Authors:
Refik Soyak,
Ebru Navruz,
Eda Ozgu Ersoy,
Gastao Cruz,
Claudia Prieto,
Andrew P. King,
Devrim Unay,
Ilkay Oksuz
Abstract:
Magnetic Resonance Fingerprinting (MRF) enables simultaneous map** of multiple tissue parameters such as T1 and T2 relaxation times. The working principle of MRF relies on varying acquisition parameters pseudo-randomly, so that each tissue generates its unique signal evolution during scanning. Even though MRF provides faster scanning, it has disadvantages such as erroneous and slow generation of…
▽ More
Magnetic Resonance Fingerprinting (MRF) enables simultaneous map** of multiple tissue parameters such as T1 and T2 relaxation times. The working principle of MRF relies on varying acquisition parameters pseudo-randomly, so that each tissue generates its unique signal evolution during scanning. Even though MRF provides faster scanning, it has disadvantages such as erroneous and slow generation of the corresponding parametric maps, which needs to be improved. Moreover, there is a need for explainable architectures for understanding the guiding signals to generate accurate parametric maps. In this paper, we addressed both of these shortcomings by proposing a novel neural network architecture consisting of a channel-wise attention module and a fully convolutional network. The proposed approach, evaluated over 3 simulated MRF signals, reduces error in the reconstruction of tissue parameters by 8.88% for T1 and 75.44% for T2 with respect to state-of-the-art methods. Another contribution of this study is a new channel selection method: attention-based channel selection. Furthermore, the effect of patch size and temporal frames of MRF signal on channel reduction are analyzed by employing a channel-wise attention.
△ Less
Submitted 2 December, 2020;
originally announced December 2020.
-
Deep Learning Based Detection and Correction of Cardiac MR Motion Artefacts During Reconstruction for High-Quality Segmentation
Authors:
Ilkay Oksuz,
James R. Clough,
Bram Ruijsink,
Esther Puyol Anton,
Aurelien Bustin,
Gastao Cruz,
Claudia Prieto,
Andrew P. King,
Julia A. Schnabel
Abstract:
Segmenting anatomical structures in medical images has been successfully addressed with deep learning methods for a range of applications. However, this success is heavily dependent on the quality of the image that is being segmented. A commonly neglected point in the medical image analysis community is the vast amount of clinical images that have severe image artefacts due to organ motion, moveme…
▽ More
Segmenting anatomical structures in medical images has been successfully addressed with deep learning methods for a range of applications. However, this success is heavily dependent on the quality of the image that is being segmented. A commonly neglected point in the medical image analysis community is the vast amount of clinical images that have severe image artefacts due to organ motion, movement of the patient and/or image acquisition related issues. In this paper, we discuss the implications of image motion artefacts on cardiac MR segmentation and compare a variety of approaches for jointly correcting for artefacts and segmenting the cardiac cavity. The method is based on our recently developed joint artefact detection and reconstruction method, which reconstructs high quality MR images from k-space using a joint loss function and essentially converts the artefact correction task to an under-sampled image reconstruction task by enforcing a data consistency term. In this paper, we propose to use a segmentation network coupled with this in an end-to-end framework. Our training optimises three different tasks: 1) image artefact detection, 2) artefact correction and 3) image segmentation. We train the reconstruction network to automatically correct for motion-related artefacts using synthetically corrupted cardiac MR k-space data and uncorrected reconstructed images. Using a test set of 500 2D+time cine MR acquisitions from the UK Biobank data set, we achieve demonstrably good image quality and high segmentation accuracy in the presence of synthetic motion artefacts. We showcase better performance compared to various image correction architectures.
△ Less
Submitted 3 July, 2020; v1 submitted 11 October, 2019;
originally announced October 2019.
-
Motion-corrected and high-resolution anatomically-assisted (MOCHA) reconstruction of arterial spin labelling MRI
Authors:
Abolfazl Mehranian,
Colm J. McGinnity,
Radhouene Neji,
Claudia Prieto,
Alexander Hammers,
Enrico De Vita,
Andrew J. Reader
Abstract:
A model-based reconstruction framework is proposed for MOtion-Corrected and High-resolution anatomically-Assisted (MOCHA) reconstruction of ASL data. In this framework, all low-resolution ASL control-label pairs are used to reconstruct a single high-resolution cerebral blood flow (CBF) map, corrected for rigid motion, point-spread-function (PSF) blurring and partial-volume effect (PVE).Six volunte…
▽ More
A model-based reconstruction framework is proposed for MOtion-Corrected and High-resolution anatomically-Assisted (MOCHA) reconstruction of ASL data. In this framework, all low-resolution ASL control-label pairs are used to reconstruct a single high-resolution cerebral blood flow (CBF) map, corrected for rigid motion, point-spread-function (PSF) blurring and partial-volume effect (PVE).Six volunteers were recruited for CBF imaging using PCASL labelling, 2-shot 3D-GRASE sequences and high-resolution T1-weighted MRI. For two volunteers, high-resolution scans with double and triple resolution in the partition direction were additionally collected. Simulations were designed for evaluations against a high-resolution ground-truth CBF map, including a simulated hyper-perfused lesion and hyper/hypo-perfusion abnormalities. MOCHA was compared to standard reconstruction and a 3D linear regression (3DLR) PVE correction method and was further evaluated for acquisitions with reduced control-label pairs and k-space undersampling. MOCHA reconstructions of low-resolution ASL data showed enhanced image quality particularly in the partition direction. In simulations, both MOCHA and 3DLR provided more accurate CBF maps than the standard reconstruction, however MOCHA resulted in the lowest errors and well delineated the abnormalities. MOCHA reconstruction of standard-resolution in-vivo data showed good agreement with higher-resolution scans requiring 4x and 9x longer acquisitions. MOCHA was found to be robust for 4x-accelerated ASL acquisitions, achieved by reduced control-label pairs or k-space undersampling. Conclusion: MOCHA reconstruction reduces PVE by direct reconstruction of CBF maps in the high-resolution space of the corresponding anatomical image, incorporating motion correction and PSF modelling. Following further evaluation, MOCHA should promote the clinical application of ASL.
△ Less
Submitted 28 September, 2019;
originally announced September 2019.
-
Detection and Correction of Cardiac MR Motion Artefacts during Reconstruction from K-space
Authors:
lkay Oksuz,
James Clough,
Bram Ruijsink,
Esther Puyol-Anton,
Aurelien Bustin,
Gastao Cruz,
Claudia Prieto,
Daniel Rueckert,
Andrew P. King,
Julia A. Schnabel
Abstract:
In fully sampled cardiac MR (CMR) acquisitions, motion can lead to corruption of k-space lines, which can result in artefacts in the reconstructed images. In this paper, we propose a method to automatically detect and correct motion-related artefacts in CMR acquisitions during reconstruction from k-space data. Our correction method is inspired by work on undersampled CMR reconstruction, and uses d…
▽ More
In fully sampled cardiac MR (CMR) acquisitions, motion can lead to corruption of k-space lines, which can result in artefacts in the reconstructed images. In this paper, we propose a method to automatically detect and correct motion-related artefacts in CMR acquisitions during reconstruction from k-space data. Our correction method is inspired by work on undersampled CMR reconstruction, and uses deep learning to optimize a data-consistency term for under-sampled k-space reconstruction. Our main methodological contribution is the addition of a detection network to classify motion-corrupted k-space lines to convert the problem of artefact correction to a problem of reconstruction using the data consistency term. We train our network to automatically correct for motion-related artefacts using synthetically corrupted cine CMR k-space data as well as uncorrupted CMR images. Using a test set of 50 2D+time cine CMR datasets from the UK Biobank, we achieve good image quality in the presence of synthetic motion artefacts. We quantitatively compare our method with a variety of techniques for recovering good image quality and showcase better performance compared to state of the art denoising techniques with a PSNR of 37.1. Moreover, we show that our method preserves the quality of uncorrupted images and therefore can be also utilized as a general image reconstruction algorithm.
△ Less
Submitted 12 June, 2019;
originally announced June 2019.