Extended State Observer for Mismatch Disturbances Using Taylor Approximation of the Integral
Authors:
Cuong Duc Nguyen
Abstract:
The development of disturbance estimators using extended state observers (ESOs) typically assumes that the system is observable. This paper introduces an improved method for systems that are initially unobservable, leveraging Taylor expansion to approximate the integral of disturbance dynamics. A new extended system is formulated based on this approximation, enabling the design of an observer that…
▽ More
The development of disturbance estimators using extended state observers (ESOs) typically assumes that the system is observable. This paper introduces an improved method for systems that are initially unobservable, leveraging Taylor expansion to approximate the integral of disturbance dynamics. A new extended system is formulated based on this approximation, enabling the design of an observer that achieves exponential stability of the error dynamics. The proposed method's efficacy is demonstrated through a practical example, highlighting its potential for robust disturbance estimation in dynamic systems.
△ Less
Submitted 5 May, 2024;
originally announced May 2024.
VisualCheXbert: Addressing the Discrepancy Between Radiology Report Labels and Image Labels
Authors:
Saahil Jain,
Akshay Smit,
Steven QH Truong,
Chanh DT Nguyen,
Minh-Thanh Huynh,
Mudit Jain,
Victoria A. Young,
Andrew Y. Ng,
Matthew P. Lungren,
Pranav Rajpurkar
Abstract:
Automatic extraction of medical conditions from free-text radiology reports is critical for supervising computer vision models to interpret medical images. In this work, we show that radiologists labeling reports significantly disagree with radiologists labeling corresponding chest X-ray images, which reduces the quality of report labels as proxies for image labels. We develop and evaluate methods…
▽ More
Automatic extraction of medical conditions from free-text radiology reports is critical for supervising computer vision models to interpret medical images. In this work, we show that radiologists labeling reports significantly disagree with radiologists labeling corresponding chest X-ray images, which reduces the quality of report labels as proxies for image labels. We develop and evaluate methods to produce labels from radiology reports that have better agreement with radiologists labeling images. Our best performing method, called VisualCheXbert, uses a biomedically-pretrained BERT model to directly map from a radiology report to the image labels, with a supervisory signal determined by a computer vision model trained to detect medical conditions from chest X-ray images. We find that VisualCheXbert outperforms an approach using an existing radiology report labeler by an average F1 score of 0.14 (95% CI 0.12, 0.17). We also find that VisualCheXbert better agrees with radiologists labeling chest X-ray images than do radiologists labeling the corresponding radiology reports by an average F1 score across several medical conditions of between 0.12 (95% CI 0.09, 0.15) and 0.21 (95% CI 0.18, 0.24).
△ Less
Submitted 15 March, 2021; v1 submitted 22 February, 2021;
originally announced February 2021.