Skip to main content

Showing 1–5 of 5 results for author: Natori, H

Searching in archive eess. Search in all archives.
.
  1. Realistic Endoscopic Image Generation Method Using Virtual-to-real Image-domain Translation

    Authors: Masahiro Oda, Kiyohito Tanaka, Hirotsugu Takabatake, Masaki Mori, Hiroshi Natori, Kensaku Mori

    Abstract: This paper proposes a realistic image generation method for visualization in endoscopic simulation systems. Endoscopic diagnosis and treatment are performed in many hospitals. To reduce complications related to endoscope insertions, endoscopic simulation systems are used for training or rehearsal of endoscope insertions. However, current simulation systems generate non-realistic virtual endoscopic… ▽ More

    Submitted 13 January, 2022; originally announced January 2022.

    Comments: Accepted paper as an oral presentation at the Joint MICCAI workshop MIAR | AE-CAI | CARE 2019

    Journal ref: Healthcare Technology Letters, Vol.6, No.6, pp.214-219, 2019

  2. Depth Estimation from Single-shot Monocular Endoscope Image Using Image Domain Adaptation And Edge-Aware Depth Estimation

    Authors: Masahiro Oda, Hayato Itoh, Kiyohito Tanaka, Hirotsugu Takabatake, Masaki Mori, Hiroshi Natori, Kensaku Mori

    Abstract: We propose a depth estimation method from a single-shot monocular endoscopic image using Lambertian surface translation by domain adaptation and depth estimation using multi-scale edge loss. We employ a two-step estimation process including Lambertian surface translation from unpaired data and depth estimation. The texture and specular reflection on the surface of an organ reduce the accuracy of d… ▽ More

    Submitted 12 January, 2022; originally announced January 2022.

    Comments: Accepted paper as an oral presentation at Joint MICCAI workshop 2021, AE-CAI/CARE/OR2.0

    Journal ref: Computer Methods in Biomechanics and Biomedical Engineering: Imaging & Visualization, 2021

  3. arXiv:2010.10207  [pdf, other

    eess.IV cs.CV cs.LG

    Micro CT Image-Assisted Cross Modality Super-Resolution of Clinical CT Images Utilizing Synthesized Training Dataset

    Authors: Tong Zheng, Hirohisa Oda, Masahiro Oda, Shota Nakamura, Masaki Mori, Hirotsugu Takabatake, Hiroshi Natori, Kensaku Mori

    Abstract: This paper proposes a novel, unsupervised super-resolution (SR) approach for performing the SR of a clinical CT into the resolution level of a micro CT ($μ$CT). The precise non-invasive diagnosis of lung cancer typically utilizes clinical CT data. Due to the resolution limitations of clinical CT (about $0.5 \times 0.5 \times 0.5$ mm$^3$), it is difficult to obtain enough pathological information s… ▽ More

    Submitted 20 October, 2020; originally announced October 2020.

  4. arXiv:2004.03272  [pdf

    cs.CV eess.IV

    Super-resolution of clinical CT volumes with modified CycleGAN using micro CT volumes

    Authors: Tong ZHENG, Hirohisa ODA, Takayasu MORIYA, Takaaki SUGINO, Shota NAKAMURA, Masahiro ODA, Masaki MORI, Hirotsugu TAKABATAKE, Hiroshi NATORI, Kensaku MORI

    Abstract: This paper presents a super-resolution (SR) method with unpaired training dataset of clinical CT and micro CT volumes. For obtaining very detailed information such as cancer invasion from pre-operative clinical CT volumes of lung cancer patients, SR of clinical CT volumes to $\m$}CT level is desired. While most SR methods require paired low- and high- resolution images for training, it is infeasib… ▽ More

    Submitted 7 April, 2020; originally announced April 2020.

    Comments: 6 pages, 2 figures

  5. arXiv:1912.12838  [pdf, other

    eess.IV cs.CV

    Multi-modality super-resolution loss for GAN-based super-resolution of clinical CT images using micro CT image database

    Authors: Tong Zheng, Hirohisa Oda, Takayasu Moriya, Shota Nakamura, Masahiro Oda, Masaki Mori, Horitsugu Takabatake, Hiroshi Natori, Kensaku Mori

    Abstract: This paper newly introduces multi-modality loss function for GAN-based super-resolution that can maintain image structure and intensity on unpaired training dataset of clinical CT and micro CT volumes. Precise non-invasive diagnosis of lung cancer mainly utilizes 3D multidetector computed-tomography (CT) data. On the other hand, we can take micro CT images of resected lung specimen in 50 micro met… ▽ More

    Submitted 7 April, 2020; v1 submitted 30 December, 2019; originally announced December 2019.

    Comments: 6 pages, 2 figures