-
An Implantable Piezofilm Middle Ear Microphone: Performance in Human Cadaveric Temporal Bones
Authors:
John Z. Zhang,
Lukas Graf,
Annesya Banerjee,
Aaron Yeiser,
Christopher I. McHugh,
Ioannis Kymissis,
Jeffrey H. Lang,
Elizabeth S. Olson,
Hideko Heidi Nakajima
Abstract:
Purpose: One of the major reasons that totally implantable cochlear microphones are not readily available is the lack of good implantable microphones. An implantable microphone has the potential to provide a range of benefits over external microphones for cochlear implant users including the filtering ability of the outer ear, cosmetics, and usability in all situations. This paper presents results…
▽ More
Purpose: One of the major reasons that totally implantable cochlear microphones are not readily available is the lack of good implantable microphones. An implantable microphone has the potential to provide a range of benefits over external microphones for cochlear implant users including the filtering ability of the outer ear, cosmetics, and usability in all situations. This paper presents results from experiments in human cadaveric ears of a piezofilm microphone concept under development as a possible component of a future implantable microphone system for use with cochlear implants. This microphone is referred to here as a drum microphone (DrumMic) that senses the robust and predictable motion of the umbo, the tip of the malleus. Methods: The performance was measured of five DrumMics inserted in four different human cadaveric temporal bones. Sensitivity, linearity, bandwidth, and equivalent input noise were measured during these experiments using a sound stimulus and measurement setup. Results: The sensitivity of the DrumMics was found to be tightly clustered across different microphones and ears despite differences in umbo and middle ear anatomy. The DrumMics were shown to behave linearly across a large dynamic range (46 dB SPL to 100 dB SPL) across a wide bandwidth (100 Hz to 8 kHz). The equivalent input noise (0.1-10 kHz) of the DrumMic and amplifier referenced to the ear canal was measured to be 54 dB SPL and estimated to be 46 dB SPL after accounting for the pressure gain of the outer ear. Conclusion: The results demonstrate that the DrumMic behaves robustly across ears and fabrication. The equivalent input noise performance was shown to approach that of commercial hearing aid microphones. To advance this demonstration of the DrumMic concept to a future prototype implantable in humans, work on encapsulation, biocompatibility, connectorization will be required.
△ Less
Submitted 22 December, 2023;
originally announced December 2023.
-
The UmboMic: A PVDF Cantilever Microphone
Authors:
Aaron J. Yeiser,
Emma F. Wawrzynek,
John Z. Zhang,
Lukas Graf,
Christopher I. McHugh,
Ioannis Kymissis,
Elizabeth S. Olson,
Jeffrey H. Lang,
Hideko Heidi Nakajima
Abstract:
Objective: We present the "UmboMic," a prototype piezoelectric cantilever microphone designed for future use with totally-implantable cochlear implants. Methods: The UmboMic sensor is made from polyvinylidene difluoride (PVDF) because of its low Young's modulus and biocompatibility. The sensor is designed to fit in the middle ear and measure the motion of the underside of the eardrum at the umbo.…
▽ More
Objective: We present the "UmboMic," a prototype piezoelectric cantilever microphone designed for future use with totally-implantable cochlear implants. Methods: The UmboMic sensor is made from polyvinylidene difluoride (PVDF) because of its low Young's modulus and biocompatibility. The sensor is designed to fit in the middle ear and measure the motion of the underside of the eardrum at the umbo. To maximize its performance, we developed a low noise charge amplifier in tandem with the UmboMic sensor. This paper presents the performance of the UmboMic sensor and amplifier in fresh cadaveric human temporal bones. Results: When tested in human temporal bones, the UmboMic apparatus achieves an equivalent input noise of 32.3 dB SPL over the frequency range 100 Hz to 7 kHz, good linearity, and a flat frequency response to within 10 dB from about 100 Hz to 6 kHz. Conclusion: These results demonstrate the feasibility of a PVDF-based microphone when paired with a low-noise amplifier. The reported UmboMic apparatus is comparable in performance to a conventional hearing aid microphone. Significance: The proof-of-concept UmboMic apparatus is a promising step towards creating a totally-implantable cochlear implant. A completely internal system would enhance the quality of life of cochlear implant users.
△ Less
Submitted 21 December, 2023;
originally announced December 2023.
-
Optimizing the Homogeneity and Efficiency of an SOEC Based on Multiphysics Simulation and Data-driven Surrogate Model
Authors:
Yingtian Chi,
Kentaro Yokoo,
Hironori Nakajima,
Kohei Ito,
** Lin,
Yonghua Song
Abstract:
Inhomogeneous current and temperature distributions are harmful to the durability of the solid oxide electrolysis cell (SOEC). Segmented SOEC experiments reveal that a high steam utilization, which is favorable for system efficiency, leads to local steam starvation and enhanced the inhomogeneity. It is necessary to consider inhomogeneity and efficiency jointly in optimization studies. Three-dimens…
▽ More
Inhomogeneous current and temperature distributions are harmful to the durability of the solid oxide electrolysis cell (SOEC). Segmented SOEC experiments reveal that a high steam utilization, which is favorable for system efficiency, leads to local steam starvation and enhanced the inhomogeneity. It is necessary to consider inhomogeneity and efficiency jointly in optimization studies. Three-dimensional (3D) multiphysics models validated with experiments can simulate the inhomogeneity in a reliable manner, but they are unsuitable for optimization due to the high computational cost. This study proposes a method that combines segmented SOEC experiments, multiphysics simulation, and artificial intelligence to optimize the inhomogeneity and efficiency of SOEC jointly. A 3D cell model is first built and verified by segmented SOEC experiments. Then, fast neural network surrogate models are built from the simulation data and integrated into a multi-objective optimization problem. Its solutions form a Pareto front reflecting the conflicting relationships among different objectives. It is found that the down-stream current is 60%-65% of the up-stream current when the steam utilization is 0.7. To increase the steam utilization to 0.8, the down-stream current will further drop to 50%-60% of the up-stream current. The Pareto fronts enable system operators to achieve a balance between efficiency and inhomogeneity.
△ Less
Submitted 25 October, 2022;
originally announced October 2022.
-
Independent Low-Rank Matrix Analysis Based on Time-Variant Sub-Gaussian Source Model
Authors:
Shinichi Mogami,
Norihiro Takamune,
Daichi Kitamura,
Hiroshi Saruwatari,
Yu Takahashi,
Kazunobu Kondo,
Hiroaki Nakajima,
Nobutaka Ono
Abstract:
Independent low-rank matrix analysis (ILRMA) is a fast and stable method for blind audio source separation. Conventional ILRMAs assume time-variant (super-)Gaussian source models, which can only represent signals that follow a super-Gaussian distribution. In this paper, we focus on ILRMA based on a generalized Gaussian distribution (GGD-ILRMA) and propose a new type of GGD-ILRMA that adopts a time…
▽ More
Independent low-rank matrix analysis (ILRMA) is a fast and stable method for blind audio source separation. Conventional ILRMAs assume time-variant (super-)Gaussian source models, which can only represent signals that follow a super-Gaussian distribution. In this paper, we focus on ILRMA based on a generalized Gaussian distribution (GGD-ILRMA) and propose a new type of GGD-ILRMA that adopts a time-variant sub-Gaussian distribution for the source model. By using a new update scheme called generalized iterative projection for homogeneous source models, we obtain a convergence-guaranteed update rule for demixing spatial parameters. In the experimental evaluation, we show the versatility of the proposed method, i.e., the proposed time-variant sub-Gaussian source model can be applied to various types of source signal.
△ Less
Submitted 24 August, 2018;
originally announced August 2018.
-
Monaural source enhancement maximizing source-to-distortion ratio via automatic differentiation
Authors:
Hiroaki Nakajima,
Yu Takahashi,
Kazunobu Kondo,
Yuji Hisaminato
Abstract:
Recently, deep neural network (DNN) has made a breakthrough in monaural source enhancement. Through a training step by using a large amount of data, DNN estimates a map** between mixed signals and clean signals. At this time, we use an objective function that numerically expresses the quality of a map** by DNN. In the conventional methods, L1 norm, L2 norm, and Itakura-Saito divergence are oft…
▽ More
Recently, deep neural network (DNN) has made a breakthrough in monaural source enhancement. Through a training step by using a large amount of data, DNN estimates a map** between mixed signals and clean signals. At this time, we use an objective function that numerically expresses the quality of a map** by DNN. In the conventional methods, L1 norm, L2 norm, and Itakura-Saito divergence are often used as objective functions. Recently, an objective function based on short-time objective intelligibility (STOI) has also been proposed. However, these functions only indicate similarity between the clean signal and the estimated signal by DNN. In other words, they do not show the quality of noise reduction or source enhancement. Motivated by the fact, this paper adopts signal-to-distortion ratio (SDR) as the objective function. Since SDR virtually shows signal-to-noise ratio (SNR), maximizing SDR solves the above problem. The experimental results revealed that the proposed method achieved better performance than the conventional methods.
△ Less
Submitted 14 June, 2018;
originally announced June 2018.