Marine Integrated Energy Microgrids
Authors:
Chendan Li,
Muzaidi Othman,
Nor Baizura Ahamad,
Marta Molinas
Abstract:
Marine sector decarbonization is another important battlefield for meeting the goal of climate action and ensuring the fulfillment of ambitions for a zero-emission society. Driven immediately by the policy incentives such as Energy Efficiency Design Index (EEDI) from International Maritime Organization(IMO), carbon taxation and labeling, a series of innovations centered around marine transportatio…
▽ More
Marine sector decarbonization is another important battlefield for meeting the goal of climate action and ensuring the fulfillment of ambitions for a zero-emission society. Driven immediately by the policy incentives such as Energy Efficiency Design Index (EEDI) from International Maritime Organization(IMO), carbon taxation and labeling, a series of innovations centered around marine transportation are emerging from both industry and academia. As an efficient energy system form, the microgrid is playing an increasingly important role as the system constitution form for various marine energy systems. With specific concern about multi-energy integrations, the conventional definition of the microgrid needs also to be extended for an integrated energy system. In this paper, we will first introduce the extended concept of the microgrid as an integrated energy system and its applications in the marine sector, and then present the state of the art for the control, operation, and system integration for it and its clusters. The challenges and opportunities for marine integrated energy microgrids will also be discussed to shed light on future research.
△ Less
Submitted 27 August, 2022;
originally announced August 2022.
-
A Practical Method for Automated Modeling and Parametric Stability Analysis of VSC with Periodical Steady State
Authors:
Chen Zhang,
Jon Are Suul,
Marta Molinas
Abstract:
Linear Time Periodic (LTP) framework-based analysis of Voltage Source Converters (VSCs) is becoming popular, a driven factor is that many of the existing VSC applications inevitably exhibit the periodic steady-state (PSS), e.g., VSCs with unbalanced grid connections and the operation of a modular multilevel converter (MMC). In these studies, acquisition of the VSC's PSS conditions is a necessary p…
▽ More
Linear Time Periodic (LTP) framework-based analysis of Voltage Source Converters (VSCs) is becoming popular, a driven factor is that many of the existing VSC applications inevitably exhibit the periodic steady-state (PSS), e.g., VSCs with unbalanced grid connections and the operation of a modular multilevel converter (MMC). In these studies, acquisition of the VSC's PSS conditions is a necessary precondition for proper linearization and stability analysis, and the efficiency of this process is particularly important for parametric studies. To this end, this work develops a computational method for automating the LTP analyses of VSCs with an integrated PSS solver. The core of the method lies in a unified frequency-domain iteration process that is developed by applying the generalized averaging principle. Given this, modeling, stability analysis, as well as the solution of PSS conditions can be unified in one process. The algorithmic implementation of the method in MATLAB is elaborated. Application of the obtained tool in impedance generation and parametric stability test is presented with an unbalanced grid-tied VSC as the exemplification. Finally, PSCAD/EMTDC simulations further consolidate the validity of the results.
△ Less
Submitted 3 December, 2021;
originally announced December 2021.
-
Impedance Network of Interconnected Power Electronics Systems: Impedance Operator and Stability Criterion
Authors:
Chen Zhang,
Marta Molinas,
Atle Rygg,
Xu Cai
Abstract:
Impedance is an intuitive and efficient way for dynamic representation of power electronics devices. One of the evident strengths, when compared to other small-signal methods, is the natural association with circuit theory. This makes them possible to be connected through basic circuit laws. However, careful attention should be paid when making this association since the impedances obtained throug…
▽ More
Impedance is an intuitive and efficient way for dynamic representation of power electronics devices. One of the evident strengths, when compared to other small-signal methods, is the natural association with circuit theory. This makes them possible to be connected through basic circuit laws. However, careful attention should be paid when making this association since the impedances obtained through linearization are local variables, often referred to locally defined reference frames. To allow the operations of these impedances using basic circuit laws, a unified reference has to be defined. Though this issue was properly addressed on the state-space models, a thorough analysis and a clarification regarding the unified impedances and stability effects are still missing. This paper aims to bridge this gap by introducing the Impedance Operator (IO) and associated properties to the development of impedance networks. First, the IO for both the AC coupled and AC/DC coupled systems are presented and verified through impedance measurements in PSCAD. Then, three types of impedance network-based stability criterions are presented along with a clarification on the consistency of stability conclusions. Finally, the Nyquist-based analysis is explored, regarding the sensitivity to partition points, to open the discussion on the identification of systems weak points.
△ Less
Submitted 15 November, 2018;
originally announced November 2018.
-
EEG-based Subjects Identification based on Biometrics of Imagined Speech using EMD
Authors:
Luis Alfredo Moctezuma,
Marta Molinas
Abstract:
When brain activity is translated into commands for real applications, the potential for human capacities augmentation is promising. In this paper, EMD is used to decompose EEG signals during Imagined Speech in order to use it as a biometric marker for creating a Biometric Recognition System. For each EEG channel, the most relevant Intrinsic Mode Functions (IMFs) are decided based on the Minkowski…
▽ More
When brain activity is translated into commands for real applications, the potential for human capacities augmentation is promising. In this paper, EMD is used to decompose EEG signals during Imagined Speech in order to use it as a biometric marker for creating a Biometric Recognition System. For each EEG channel, the most relevant Intrinsic Mode Functions (IMFs) are decided based on the Minkowski distance, and for each IMF 4 features are computed: Instantaneous and Teager energy distribution and Higuchi and Petrosian Fractal Dimension. To test the proposed method, a dataset with 20 subjects who imagined 30 repetitions of 5 words in Spanish, is used. Four classifiers are used for this task - random forest, SVM, naive Bayes, and k-NN - and their performances are compared. The accuracy obtained (up to 0.92 using Linear SVM) after 10-folds cross-validation suggest that the proposed method based on EMD can be valuable for creating EEG-based biometrics of imagined speech for Subjects identification.
△ Less
Submitted 13 September, 2018;
originally announced September 2018.
-
Impact of Digital Time Delay on the Stable Grid Hosting Capacity of Large-scale Centralized Photovoltaic Plant
Authors:
**hong Liu,
Lin Zhou,
Marta Molinas
Abstract:
In view of the trend towards extensive application of digital controllers in the PV inverter of large-scale centralized photovoltaic (LSCPV) plant and the increasing number of grid-connected LSCPV plants, this paper investigates in detail the influence of the digital time delay of the inverter digital controller on the stable grid-hosting capacity of LSCPV plant. The studies are based on the Norto…
▽ More
In view of the trend towards extensive application of digital controllers in the PV inverter of large-scale centralized photovoltaic (LSCPV) plant and the increasing number of grid-connected LSCPV plants, this paper investigates in detail the influence of the digital time delay of the inverter digital controller on the stable grid-hosting capacity of LSCPV plant. The studies are based on the Norton equivalent model of the grid-connected LSCPV system considering the digital time delay when modelling the digital control system of the PV inverter. Taking into account the actual situation in LSCPV plant, the stable grid-hosting capacity of LSCPV is discussed for the cases in which the PV inverters in the LSCPV plant have the same and different digital time delay values by using the root-locus method. Simulation results of the digitally controlled grid-connected LSCPV system model validates the theoretical analysis.
△ Less
Submitted 16 July, 2018;
originally announced July 2018.
-
Understanding the Nonlinear Behavior and Frequency Stability of a Grid-synchronized VSC Under Grid Voltage Dips
Authors:
Chen Zhang,
Marta Molinas,
Xu Cai,
Atle Rygg
Abstract:
Transients of a grid-synchronized voltage source converter (VSC) are closely related to over- currents and voltages occurred under large disturbances (e.g. a grid fault). Previous analysis in evaluating these transients usually neglect the nonlinear control effects of a VSC (e.g. phase-locked-loop, PLL). Therefore, potential stability issues related with nonlinear dynamics cannot be revealed prope…
▽ More
Transients of a grid-synchronized voltage source converter (VSC) are closely related to over- currents and voltages occurred under large disturbances (e.g. a grid fault). Previous analysis in evaluating these transients usually neglect the nonlinear control effects of a VSC (e.g. phase-locked-loop, PLL). Therefore, potential stability issues related with nonlinear dynamics cannot be revealed properly. This work aims to move further in this respect. To better analyze and gain more insights into the nonlinear properties, dynamical analysis of a grid-tied VSC is conducted by parts. Specifically, the nonlinear behaviors of VSC power control loop (PCL) are firstly analyzed, in which the dynamics of PLL are assumed steady. Then, the nonlinear behaviors of PLL-dominant dynamics are further explored in detail, where the PCL is assumed steady. In this case, frequency instability and the mechanisms behind it are revealed. At last, effects of PQ controller regulation as well as controller bandwidth on the frequency stability are discussed. All the analysis and conclusions are verified by time domain simulations in PSCAD/EMTDC, where a switching model of VSC is adopted.
△ Less
Submitted 29 June, 2018;
originally announced June 2018.
-
Comparison of frequency estimation methods for wave energy control
Authors:
Paula B. Garcia-Rosa,
John V. Ringwood,
Olav B. Fosso,
Marta Molinas
Abstract:
A number of wave energy controllers tune the power take-off (PTO) system to the frequency of incident waves. Since real ocean waves are non-stationary by nature and not defined by a single frequency component, the PTO can be either tuned at a constant frequency characterized by the local spectrum, or continuously tuned to a representative wave frequency. In either case, a time-frequency representa…
▽ More
A number of wave energy controllers tune the power take-off (PTO) system to the frequency of incident waves. Since real ocean waves are non-stationary by nature and not defined by a single frequency component, the PTO can be either tuned at a constant frequency characterized by the local spectrum, or continuously tuned to a representative wave frequency. In either case, a time-frequency representation of the waves is expected since the wave profile changes over time. This paper discusses about the PTO tuning problem for passive and reactive controllers, in real waves, by comparing different methods for time-varying frequency estimation: the extended Kalman filter (EKF), frequency-locked loop (FLL), and Hilbert-Huang transform (HHT). The aim is to verify the impact of such methods on the absorbed and reactive powers, and the PTO rating. It is shown that the mean estimated frequency of the EKF, and FLL, converges respectively to the mean centroid frequency, and energy frequency, of the excitation force spectrum. Moreover, the HHT mean frequency has no correlation with the spectral statistical properties. A comparison of the energy absorbed shows that up to 37% more energy is obtained with the HHT over the other estimation methods. Numerical simulations are performed with sea elevation data from the Irish coast.
△ Less
Submitted 6 April, 2018;
originally announced April 2018.
-
Harmonic State Space Modeling of a Three-Phase Modular Multilevel Converter
Authors:
**g Lyu,
Marta Molinas,
Xu Cai
Abstract:
This paper presents the harmonic state space (HSS) modeling of a three-phase modular multilevel converter (MMC). MMC is a converter system with a typical multi-frequency response due to its significant harmonics in the arm currents, capacitor voltages, and control signals. These internal harmonic dynamics can have a great influence on the operation characteristics of MMC. However, the conventional…
▽ More
This paper presents the harmonic state space (HSS) modeling of a three-phase modular multilevel converter (MMC). MMC is a converter system with a typical multi-frequency response due to its significant harmonics in the arm currents, capacitor voltages, and control signals. These internal harmonic dynamics can have a great influence on the operation characteristics of MMC. However, the conventional modeling methods commonly used in two-level voltage-source converters (VSCs), where only the fundamental-frequency dynamic is considered, will lead to an inaccurate model that cannot accurately reflect the real dynamic characteristics of MMC. Therefore, the HSS modeling method, in which harmonics of state variables, inputs, and outputs are posed separately in a state-space form, is introduced in this paper to model the MMC in order to capture all the harmonics and the frequency couplings. The steady-state and small-signal dynamic HSS models of a three-phase MMC are developed, respectively. The validity of the developed HSS model of a three-phase MMC has been verified by the results from both the nonlinear time domain simulation model in MATLAB/Simulink and the laboratory prototype with 12 submodules per arm.
△ Less
Submitted 29 June, 2017;
originally announced June 2017.
-
A simple method for shifting local dq impedance models to a global reference frame for stability analysis
Authors:
Atle Rygg,
Marta Molinas,
Eneko Unamuno,
Chen Zhang,
Xu Cai
Abstract:
Impedance-based stability analysis in the dq-domain is a widely applied method for power electronic dominated systems. An inconvenient property with this method is that impedance models are normally referred to their own local reference frame, and need to be recalculated when referring to a global reference frame in a given network. This letter presents a simple method for translating impedance su…
▽ More
Impedance-based stability analysis in the dq-domain is a widely applied method for power electronic dominated systems. An inconvenient property with this method is that impedance models are normally referred to their own local reference frame, and need to be recalculated when referring to a global reference frame in a given network. This letter presents a simple method for translating impedance sub-models within a complex network, from their own reference frames to any given point in the network. What distinguishes this method is that by using a simple rotational matrix, it only needs impedance models in their own local reference frames, to be translated to a global reference in the network. By way of this method, standard circuit analysis rules for series and parallel connection are applicable, as proven in the letter. The method is defined and validated for impedances in the dq and modified sequence domains, and it is shown that the dependency on reference frame is marginal in the latter. An additional finding from the application of this method is that components or subsystems with a certain symmetry property called Mirror Frequency Decoupling are invariant to the choice of reference frame.
△ Less
Submitted 26 June, 2017;
originally announced June 2017.
-
Impedance Analysis of Modular Multilevel Converter Based on Harmonic State-Space Modeling Method
Authors:
**g Lyu,
Qiang Chen,
Xu Cai,
Marta Molinas
Abstract:
The small-signal impedance modeling of modular multilevel converter (MMC) is the key for analyzing resonance and stability of MMC-based ac power electronics systems. MMC is a converter system with a typical multi-frequency response due to its significant steady-state harmonic components in the arm currents, capacitor voltages, and control signals. Therefore, traditional small-signal modeling metho…
▽ More
The small-signal impedance modeling of modular multilevel converter (MMC) is the key for analyzing resonance and stability of MMC-based ac power electronics systems. MMC is a converter system with a typical multi-frequency response due to its significant steady-state harmonic components in the arm currents, capacitor voltages, and control signals. Therefore, traditional small-signal modeling methods for 2-level voltage-source converters (VSCs) cannot be directly applied to the MMC. In this paper, the harmonic state-space (HSS) modeling approach is introduced to characterize the harmonic coupling behavior of the MMC. On this basis, the small-signal impedance models of the MMC are developed according to the harmonic linearization principle, which can include all the steady-state harmonic effects of the state variables, leading to the accurate impedance models. Furthermore, in order to reveal the impact of the internal dynamics and closed-loop control on the small-signal impedance of the MMC, three cases are considered in this paper, i.e., open-loop control, ac voltage closed-loop control, and circulating current closed-loop control. Finally, the analytical impedance models are verified by both simulation and experimental results.
△ Less
Submitted 2 May, 2017;
originally announced May 2017.
-
Non-parametric Impedance based Stability and Controller Bandwidth Extraction from Impedance Measurements of HVDC-connected Wind Farms
Authors:
Mohammad Amin,
Marta Molinas
Abstract:
Impedance measurements have been widely used with the Nyquist plot to estimate the stability of interconnected power systems. Being a black-box method for equivalent and aggregated impedance estimation, its use for the identification of sub-components bandwidth is not a straightforward task. This paper proposes a simple method that will enable to identify the specific part of the equivalent impeda…
▽ More
Impedance measurements have been widely used with the Nyquist plot to estimate the stability of interconnected power systems. Being a black-box method for equivalent and aggregated impedance estimation, its use for the identification of sub-components bandwidth is not a straightforward task. This paper proposes a simple method that will enable to identify the specific part of the equivalent impedance (e.g. controller's bandwidth) that has major impact on the stability of the system. For doing that, the paper analyses the stability of an interconnected system of wind farms and high voltage dc (HVDC) transmission system. The impedance frequency responses of the wind farms and HVDC system from the ac collection point are measured and it is shown by the method proposed in this paper, which controller has major impact in the observed oscillation. A mitigation technique is proposed based on re-tuning of the critical controller bandwidth of the interconnected converters. The method suggested can reveal the internal controllers' dynamics of the wind farm from the measured impedance combined with an analytical expression of the impedance and a transfer function identity when no information about the controllers is provided by the vendors due to confidentiality and industry secrecy.
△ Less
Submitted 16 April, 2017;
originally announced April 2017.
-
Model Predictive Control of Voltage Source Converter in a HVDC System
Authors:
Mohammad Amin,
Marta Molinas
Abstract:
Model Predictive Control (MPC) method is a class of advanced control techniques most widely applied in industry. The major advantages of the MPC are its straightforward procedure which can be applied for both linear and nonlinear system. This paper proposes the use of MPC for voltage source converter (VSC) in a high voltage direct current (HVDC) system. A MPC controller is modeled based on the sta…
▽ More
Model Predictive Control (MPC) method is a class of advanced control techniques most widely applied in industry. The major advantages of the MPC are its straightforward procedure which can be applied for both linear and nonlinear system. This paper proposes the use of MPC for voltage source converter (VSC) in a high voltage direct current (HVDC) system. A MPC controller is modeled based on the state-space model of a single VSC-HVDC station including the dynamics of the main ac grid. A full scale nonlinear switching model of point-to-point connected VSC-based HVDC system is developed in Matlab/Simulink association with SimPower system to demonstrate the application of the proposed controller.
△ Less
Submitted 13 April, 2017;
originally announced April 2017.
-
Accurate and reduced SISO Sequence Impedance Models of Grid-tied Voltage Source Converter for Small Signal Stability Analysis
Authors:
Chen Zhang,
Xu Cai,
Atle Rygg,
Marta Molinas
Abstract:
Impedance models are widely used in assessing small signal stability of grid-tied voltage source converter (VSC) systems. Recent research has proven that impedance models of grid-tied VSC in both dq and sequence domains are generally Multi-Input Multi-Output (MIMO) systems, and the generalized Nyquist criterion has to be applied for stability analysis to these MIMO systems. However, finding Single…
▽ More
Impedance models are widely used in assessing small signal stability of grid-tied voltage source converter (VSC) systems. Recent research has proven that impedance models of grid-tied VSC in both dq and sequence domains are generally Multi-Input Multi-Output (MIMO) systems, and the generalized Nyquist criterion has to be applied for stability analysis to these MIMO systems. However, finding Single-Input and Single-Output (SISO) equivalents for this system is always appealing because of the simplicity and the convenience for physical interpretation when assessing the stability, compared to MIMO systems. This paper presents two types of SISO impedance models of grid-tied VSC system, one is derived from the strong grid assumption, and the other is from the closed-loop equivalence. The accuracy of these models is assessed with respect to the measured impedances in PSCAD/EMTDC, and their effects on the stability assessment were analyzed as well. It is proven that the accurate SISO model gives identical result as the MIMO (matrix-based) impedance model with respect to stability analysis. However, the reduced SISO model may lead to wrong results if the bandwidth of phase locked loop is large.
△ Less
Submitted 13 April, 2017;
originally announced April 2017.
-
Augmented Sequence Impedance Networks of Grid-tied Voltage Source Converter for Stability Analysis
Authors:
Chen Zhang,
Xu Cai,
Atle Rygg,
Marta Molinas
Abstract:
Impedance-based stability analysis is appealing in the case of Single-Input Single-Output (SISO) systems. However, in the case of grid-tied voltage source converter (VSC) systems, dq impedances of source and load (VSC) subsystems are typically Multi-Input Multi-Output (MIMO) systems in which case the Generalized Nyquist Criterion (GNC) is required for analyzing the closed loop stability, which inc…
▽ More
Impedance-based stability analysis is appealing in the case of Single-Input Single-Output (SISO) systems. However, in the case of grid-tied voltage source converter (VSC) systems, dq impedances of source and load (VSC) subsystems are typically Multi-Input Multi-Output (MIMO) systems in which case the Generalized Nyquist Criterion (GNC) is required for analyzing the closed loop stability, which increases the complexity of the analysis. This paper explores further the coupling between positive and negative sequence impedances, in particular the dependency and bindings between them. It shows that the couplings in each subsystem can be compounded into two non-coupled sequence impedances if the source and load subsystems are viewed as an integrated system instead of as two separate subsystems. Therefore, two decoupled SISO systems are obtained which are defined as Augmented Sequence Impedance Networks (ASIN). The stability analysis of the closed loop system is performed directly on the ASIN with the principal of Argument. Both numerical and time domain verifications are presented.
△ Less
Submitted 11 March, 2017;
originally announced March 2017.
-
Coupled and decoupled impedance models compared in power electronics systems
Authors:
Atle Rygg,
Marta Molinas,
Chen Zhang,
Xu Cai
Abstract:
This paper provides a comparative analysis of impedance models for power electronic converters and systems for the purpose of stability investigations. Such models can be divided into either decoupled models or matrix models. A decoupled impedance model is highly appealing since the Single-Input-Single-Output (SISO) structure makes the analysis and result interpretation very simple. On the other h…
▽ More
This paper provides a comparative analysis of impedance models for power electronic converters and systems for the purpose of stability investigations. Such models can be divided into either decoupled models or matrix models. A decoupled impedance model is highly appealing since the Single-Input-Single-Output (SISO) structure makes the analysis and result interpretation very simple. On the other hand, matrix impedance models are more accurate, and in some cases necessary. Previous works have applied various approximations to obtain decoupled models, and both the dq- and sequence domains have been used. This paper introduces the terms decoupled and semi-decoupled impedance models in order to have a clear classification of the available approximations.
The accuracy of 4 decoupled impedance models are discussed based on the concept of Mirror Frequency Coupling (MFC). By definition the decoupled models based on sequence domain impedances will be exact for systems without MFC. In the general case, they are expected to be more accurate than the decoupled dq-impedance models. The paper defines a norm $ε$ to measure the degree of coupling in the impedance matrices. This norm equals the error in the eigenvalue loci between the matrix and semi-decoupled models. This can also be viewed as the error in the semi-decoupled Nyquist plot.
An example case study consisting of a grid-connected VSC with current controller and PLL is used to compare the different methods. It is found that decoupled and semi-decoupled models in the dq-domain are only applicable in grids with very low X/R-ratio. Furthermore, it is concluded that the decoupled model in the sequence domain gives close to equal results as the semi-decoupled model.
△ Less
Submitted 17 October, 2016;
originally announced October 2016.
-
A modified sequence domain impedance definition and its equivalence to the dq-domain impedance definition for the stability analysis of AC power electronic systems
Authors:
Atle Rygg,
Marta Molinas,
Zhang Chen,
Xu Cai
Abstract:
Representations of AC power systems by frequency dependent impedance equivalents is an emerging technique in the dynamic analysis of power systems including power electronic converters. The technique has been applied for decades in DC-power systems, and it was recently adopted to map the impedances in AC systems. Most of the work on AC systems can be categorized in two approaches. One is the analy…
▽ More
Representations of AC power systems by frequency dependent impedance equivalents is an emerging technique in the dynamic analysis of power systems including power electronic converters. The technique has been applied for decades in DC-power systems, and it was recently adopted to map the impedances in AC systems. Most of the work on AC systems can be categorized in two approaches. One is the analysis of the system in the \textit{dq}-domain, whereas the other applies harmonic linearization in the phase domain through symmetric components. Impedance models based on analytical calculations, numerical simulation and experimental studies have been previously developed and verified in both domains independently. The authors of previous studies discuss the advantages and disadvantages of each domain separately, but neither a rigorous comparison nor an attempt to bridge them has been conducted. The present paper attempts to close this gap by deriving the mathematical formulation that shows the equivalence between the \textit{dq}-domain and the sequence domain impedances. A modified form of the sequence domain impedance matrix is proposed, and with this definition the stability estimates obtained with the Generalized Nyquist Criterion (GNC) become equivalent in both domains. The second contribution of the paper is the definition of a \textit{Mirror Frequency Decoupled} (MFD) system. The analysis of MFD systems is less complex than that of non-MFD systems because the positive and negative sequences are decoupled. This paper shows that if a system is incorrectly assumed to be MFD, this will lead to an erroneous or ambiguous estimation of the equivalent impedance.
△ Less
Submitted 28 April, 2016;
originally announced May 2016.
-
Global Tracking Passivity--based PI Control of Bilinear Systems and its Application to the Boost and Modular Multilevel Converters
Authors:
R. Cisneros,
M. Pirro,
G. Bergna,
R. Ortega,
G. Ippoliti,
M. Molinas
Abstract:
This paper deals with the problem of trajectory tracking of a class of bilinear systems with time--varying measurable disturbance. A set of matrices {A,B_i} has been identified, via a linear matrix inequality, for which it is possible to ensure global tracking of (admissible, differentiable) trajectories with a simple linear time--varying PI controller. Instrumental to establish the result is the…
▽ More
This paper deals with the problem of trajectory tracking of a class of bilinear systems with time--varying measurable disturbance. A set of matrices {A,B_i} has been identified, via a linear matrix inequality, for which it is possible to ensure global tracking of (admissible, differentiable) trajectories with a simple linear time--varying PI controller. Instrumental to establish the result is the construction of an output signal with respect to which the incremental model is passive. The result is applied to the boost and the modular multilevel converter for which experimental results are given.
△ Less
Submitted 25 March, 2015;
originally announced March 2015.
-
Enhanced active power filter control for nonlinear non-stationary reactive power compensation
Authors:
Phen Chiak See,
Vin Cent Tai,
Marta Molinas,
Kjetil Uhlen,
Olav Bjarte Fosso
Abstract:
This paper describes a method to implement Reactive Power Compensation (RPC) in power systems that possess nonlinear non-stationary current disturbances. The Empirical Mode Decomposition (EMD) introduced in the Hilbert-Huang Transform (HHT) is used to separate the disturbances from the original current waveform. These disturbances are subsequently removed. Following that, Power Factor Correction (…
▽ More
This paper describes a method to implement Reactive Power Compensation (RPC) in power systems that possess nonlinear non-stationary current disturbances. The Empirical Mode Decomposition (EMD) introduced in the Hilbert-Huang Transform (HHT) is used to separate the disturbances from the original current waveform. These disturbances are subsequently removed. Following that, Power Factor Correction (PFC) based on the well-known p-q power theory is conducted to remove the reactive power. Both operations were implemented in a shunt Active Power Filter (APF). The EMD significantly simplifies the singulation and the removal of the current disturbances. This helps to effectively identify the fundamental current waveform. Hence, it simplifies the implementation of RPC on nonlinear non-stationary power systems.
△ Less
Submitted 19 June, 2012;
originally announced June 2012.
-
Performance assessment of two active power filter control strategies in the presence of non-stationary currents
Authors:
Vin Cent Tai,
Phen Chiak See,
Marta Molinas,
Kjetil Uhlen
Abstract:
This paper describes an active power filter (APF) control strategy, which eliminates harmonics and compensates reactive power in a three-phase four-wire power system supplying non-linear unbalanced loads in the presence of non-linear non-stationary currents. Empirical Mode Decomposition (EMD) technique developed as part of the Hilbert-Huang Transform (HHT) is used to singulate the harmonics and no…
▽ More
This paper describes an active power filter (APF) control strategy, which eliminates harmonics and compensates reactive power in a three-phase four-wire power system supplying non-linear unbalanced loads in the presence of non-linear non-stationary currents. Empirical Mode Decomposition (EMD) technique developed as part of the Hilbert-Huang Transform (HHT) is used to singulate the harmonics and non-linear non stationary disturbances from the load currents. The control strategy for the APF is formulated by hybridizing the so called modified p-q theory with the EMD algorithm. A four-leg split-capacitor converter controlled by hysteresis band current controller is used as an APF. The results obtained are compared with those obtained with the conventional modified p-q theory, which does not possess current harmonics or distortions separation strategy, to validate its performance.
△ Less
Submitted 7 June, 2012;
originally announced June 2012.