No-gold-standard evaluation of quantitative imaging methods in the presence of correlated noise
Authors:
Zi** Liu,
Zekun Li,
Joyce C. Mhlanga,
Barry A. Siegel,
Abhinav K. Jha
Abstract:
Objective evaluation of quantitative imaging (QI) methods with patient data is highly desirable, but is hindered by the lack or unreliability of an available gold standard. To address this issue, techniques that can evaluate QI methods without access to a gold standard are being actively developed. These techniques assume that the true and measured values are linearly related by a slope, bias, and…
▽ More
Objective evaluation of quantitative imaging (QI) methods with patient data is highly desirable, but is hindered by the lack or unreliability of an available gold standard. To address this issue, techniques that can evaluate QI methods without access to a gold standard are being actively developed. These techniques assume that the true and measured values are linearly related by a slope, bias, and Gaussian-distributed noise term, where the noise between measurements made by different methods is independent of each other. However, this noise arises in the process of measuring the same quantitative value, and thus can be correlated. To address this limitation, we propose a no-gold-standard evaluation (NGSE) technique that models this correlated noise by a multi-variate Gaussian distribution parameterized by a covariance matrix. We derive a maximum-likelihood-based approach to estimate the parameters that describe the relationship between the true and measured values, without any knowledge of the true values. We then use the estimated slopes and diagonal elements of the covariance matrix to compute the noise-to-slope ratio (NSR) to rank the QI methods on the basis of precision. The proposed NGSE technique was evaluated with multiple numerical experiments. Our results showed that the technique reliably estimated the NSR values and yielded accurate rankings of the considered methods for ~ 83% of 160 trials. In particular, the technique correctly identified the most precise method for ~ 97% of the trials. Overall, this study demonstrates the efficacy of the NGSE technique to accurately rank different QI methods when the correlated noise is present, and without access to any knowledge of the ground truth. The results motivate further validation of this technique with realistic simulation studies and patient data.
△ Less
Submitted 3 March, 2022;
originally announced March 2022.
A Bayesian approach to tissue-fraction estimation for oncological PET segmentation
Authors:
Zi** Liu,
Joyce C. Mhlanga,
Richard Laforest,
Paul-Robert Derenoncourt,
Barry A. Siegel,
Abhinav K. Jha
Abstract:
Tumor segmentation in oncological PET is challenging, a major reason being the partial-volume effects that arise due to low system resolution and finite voxel size. The latter results in tissue-fraction effects, i.e. voxels contain a mixture of tissue classes. Conventional segmentation methods are typically designed to assign each voxel in the image as belonging to a certain tissue class. Thus, th…
▽ More
Tumor segmentation in oncological PET is challenging, a major reason being the partial-volume effects that arise due to low system resolution and finite voxel size. The latter results in tissue-fraction effects, i.e. voxels contain a mixture of tissue classes. Conventional segmentation methods are typically designed to assign each voxel in the image as belonging to a certain tissue class. Thus, these methods are inherently limited in modeling tissue-fraction effects. To address the challenge of accounting for partial-volume effects, and in particular, tissue-fraction effects, we propose a Bayesian approach to tissue-fraction estimation for oncological PET segmentation. Specifically, this Bayesian approach estimates the posterior mean of fractional volume that the tumor occupies within each voxel of the image. The proposed method, implemented using a deep-learning-based technique, was first evaluated using clinically realistic 2-D simulation studies with known ground truth, in the context of segmenting the primary tumor in PET images of patients with lung cancer. The evaluation studies demonstrated that the method accurately estimated the tumor-fraction areas and significantly outperformed widely used conventional PET segmentation methods, including a U-net-based method, on the task of segmenting the tumor. In addition, the proposed method was relatively insensitive to partial-volume effects and yielded reliable tumor segmentation for different clinical-scanner configurations. The method was then evaluated using clinical images of patients with stage IIB/III non-small cell lung cancer from ACRIN 6668/RTOG 0235 multi-center clinical trial. Here, the results showed that the proposed method significantly outperformed all other considered methods and yielded accurate tumor segmentation on patient images with Dice similarity coefficient (DSC) of 0.82 (95 % CI: [0.78, 0.86]).
△ Less
Submitted 27 May, 2022; v1 submitted 29 February, 2020;
originally announced March 2020.