Plane-wave compounding with adaptive joint coherence factor weighting
Authors:
Nikunj Khetan,
Jerome Mertz
Abstract:
Coherent Plane Wave Compounding (CPWC) is widely used for ultrasound imaging. This technique involves sending plane waves into a sample at different transmit angles and recording the resultant backscattered echo at different receive positions. The time-delayed signals from the different combinations of transmit angles and receive positions are then coherently summed to produce a beamformed image.…
▽ More
Coherent Plane Wave Compounding (CPWC) is widely used for ultrasound imaging. This technique involves sending plane waves into a sample at different transmit angles and recording the resultant backscattered echo at different receive positions. The time-delayed signals from the different combinations of transmit angles and receive positions are then coherently summed to produce a beamformed image. Various techniques have been developed to characterize the quality of CPWC beamforming based on the measured coherence across the transmit or receive apertures. Here, we propose a more fine-grained approach where the signals from every transmit/receive combination are separately evaluated using a quality metric based on their joint spatio-angular coherence. The signals are then individually weighted according to their measured Joint Coherence Factor (JCF) prior to being coherently summed. To facilitate the comparison of JCF beamforming compared to alternative techniques, we further propose a method of image display standardization based on contrast matching. We show results from tissue-mimicking phantoms and human soft-tissue imaging. Fine-grained JCF weighting is found to improve CPWC image quality compared to alternative approaches.
△ Less
Submitted 17 June, 2024; v1 submitted 18 April, 2024;
originally announced April 2024.
-
Interferometric speckle visibility spectroscopy (iSVS) for measuring decorrelation time and dynamics of moving samples with enhanced signal-to-noise ratio and relaxed reference requirements
Authors:
Yu Xi Huang,
Simon Mahler,
Jerome Mertz,
Changhuei Yang
Abstract:
Diffusing wave spectroscopy (DWS) is a group of techniques used to measure the dynamics of a scattering medium in a non-invasive manner. DWS methods rely on detecting the speckle light field from the moving scattering media and measuring the speckle decorrelation time to quantify the scattering mediums dynamics. For DWS, the signal-to-noise (SNR) is determined by the ratio between measured decorre…
▽ More
Diffusing wave spectroscopy (DWS) is a group of techniques used to measure the dynamics of a scattering medium in a non-invasive manner. DWS methods rely on detecting the speckle light field from the moving scattering media and measuring the speckle decorrelation time to quantify the scattering mediums dynamics. For DWS, the signal-to-noise (SNR) is determined by the ratio between measured decorrelation time to the standard error of the measurement. This SNR is often low in certain applications because of high noise variances and low signal intensity, especially in biological applications with restricted exposure and emission levels. To address this photon-limited signal-to-noise ratio problem, we investigated, theoretically and experimentally, the SNR of an interferometric speckle visibility spectroscopy (iSVS) compared to more traditional DWS methods. We found that iSVS can provide excellent SNR performance through its ability to overcome camera noise. We also proved iSVS system has more relaxed constraints on the reference beam properties than most other interferometric systems. For an iSVS to function properly, we simply require the reference beam to exhibit local temporal stability, while incident angle, reference phase, and intensity uniformity do not need to be constrained. This flexibility can potentially enable more unconventional iSVS implementation schemes.
△ Less
Submitted 30 June, 2023;
originally announced June 2023.
-
Ultrasound differential phase contrast using backscattering and the memory effect
Authors:
Timothy D. Weber,
Nikunj Khetan,
Ruohui Yang,
Jerome Mertz
Abstract:
We describe a simple and fast technique to perform ultrasound differential phase contrast (DPC) imaging in arbitrarily thick scattering media. Though configured in a reflection geometry, DPC is based on transmission imaging and is a direct analogue of optical differential interference contrast (DIC). DPC exploits the memory effect and works in combination with standard pulse-echo imaging, with no…
▽ More
We describe a simple and fast technique to perform ultrasound differential phase contrast (DPC) imaging in arbitrarily thick scattering media. Though configured in a reflection geometry, DPC is based on transmission imaging and is a direct analogue of optical differential interference contrast (DIC). DPC exploits the memory effect and works in combination with standard pulse-echo imaging, with no additional hardware or data requirements, enabling complementary phase contrast (in the transverse direction) without any need for intensive numerical computation. We experimentally demonstrate the principle of DPC using tissue phantoms with calibrated speed-of-sound inclusions.
△ Less
Submitted 14 March, 2021;
originally announced March 2021.
-
Speed-of-sound imaging by differential phase contrast with angular compounding
Authors:
Nikunj Khetan,
Timothy Weber,
Jerome Mertz
Abstract:
We describe a technique to reveal speed-of-sound (SoS) variations within an echogenic sample. The technique uses the same receive data as standard pulse-echo imaging based on plane-wave compounding, and can be operated in parallel. Point-like scatterers randomly distributed throughout the sample serve as local probes of the downstream transmit-beam phase shifts caused by aberrating structures with…
▽ More
We describe a technique to reveal speed-of-sound (SoS) variations within an echogenic sample. The technique uses the same receive data as standard pulse-echo imaging based on plane-wave compounding, and can be operated in parallel. Point-like scatterers randomly distributed throughout the sample serve as local probes of the downstream transmit-beam phase shifts caused by aberrating structures within the sample. Phase shifts are monitored in a differential manner, providing signatures of transverse gradients of the local sample SoS. The contrast of the signatures is augmented by a method of angular compounding, which provides ``focus" control of the image sharpness, which, in turn, enables a visual localization of aberrating inclusions within the sample on the fly. The localization can be performed in 2D when operated with standard B-mode imaging, or in 3D when operated with C-mode imaging. Finally, we present a wave-acoustic forward model that provides insight into the principle of differential phase contrast (DPC) imaging, and roughly recapitulates experimental results obtained with an elastography phantom. In particular, we demonstrate that our technique easily reveals relative SoS variations as small as 0.5\% in real time. Such imaging may ultimately be useful for clinical diagnosis of pathologies in soft tissue.
△ Less
Submitted 6 July, 2020;
originally announced July 2020.