The STOIC2021 COVID-19 AI challenge: applying reusable training methodologies to private data
Authors:
Luuk H. Boulogne,
Julian Lorenz,
Daniel Kienzle,
Robin Schon,
Katja Ludwig,
Rainer Lienhart,
Simon Jegou,
Guang Li,
Cong Chen,
Qi Wang,
Derik Shi,
Mayug Maniparambil,
Dominik Muller,
Silvan Mertes,
Niklas Schroter,
Fabio Hellmann,
Miriam Elia,
Ine Dirks,
Matias Nicolas Bossa,
Abel Diaz Berenguer,
Tanmoy Mukherjee,
Jef Vandemeulebroucke,
Hichem Sahli,
Nikos Deligiannis,
Panagiotis Gonidakis
, et al. (13 additional authors not shown)
Abstract:
Challenges drive the state-of-the-art of automated medical image analysis. The quantity of public training data that they provide can limit the performance of their solutions. Public access to the training methodology for these solutions remains absent. This study implements the Type Three (T3) challenge format, which allows for training solutions on private data and guarantees reusable training m…
▽ More
Challenges drive the state-of-the-art of automated medical image analysis. The quantity of public training data that they provide can limit the performance of their solutions. Public access to the training methodology for these solutions remains absent. This study implements the Type Three (T3) challenge format, which allows for training solutions on private data and guarantees reusable training methodologies. With T3, challenge organizers train a codebase provided by the participants on sequestered training data. T3 was implemented in the STOIC2021 challenge, with the goal of predicting from a computed tomography (CT) scan whether subjects had a severe COVID-19 infection, defined as intubation or death within one month. STOIC2021 consisted of a Qualification phase, where participants developed challenge solutions using 2000 publicly available CT scans, and a Final phase, where participants submitted their training methodologies with which solutions were trained on CT scans of 9724 subjects. The organizers successfully trained six of the eight Final phase submissions. The submitted codebases for training and running inference were released publicly. The winning solution obtained an area under the receiver operating characteristic curve for discerning between severe and non-severe COVID-19 of 0.815. The Final phase solutions of all finalists improved upon their Qualification phase solutions.HSUXJM-TNZF9CHSUXJM-TNZF9C
△ Less
Submitted 25 June, 2023; v1 submitted 18 June, 2023;
originally announced June 2023.
-
COVID Detection and Severity Prediction with 3D-ConvNeXt and Custom Pretrainings
Authors:
Daniel Kienzle,
Julian Lorenz,
Robin Schön,
Katja Ludwig,
Rainer Lienhart
Abstract:
Since COVID strongly affects the respiratory system, lung CT-scans can be used for the analysis of a patients health. We introduce a neural network for the prediction of the severity of lung damage and the detection of a COVID-infection using three-dimensional CT-data. Therefore, we adapt the recent ConvNeXt model to process three-dimensional data. Furthermore, we design and analyze different pret…
▽ More
Since COVID strongly affects the respiratory system, lung CT-scans can be used for the analysis of a patients health. We introduce a neural network for the prediction of the severity of lung damage and the detection of a COVID-infection using three-dimensional CT-data. Therefore, we adapt the recent ConvNeXt model to process three-dimensional data. Furthermore, we design and analyze different pretraining methods specifically designed to improve the models ability to handle three-dimensional CT-data. We rank 2nd in the 1st COVID19 Severity Detection Challenge and 3rd in the 2nd COVID19 Detection Challenge.
△ Less
Submitted 17 August, 2022; v1 submitted 30 June, 2022;
originally announced June 2022.
-
The impact of varying electrical stimulation parameters on neuromuscular response
Authors:
Dhruv Pai,
Mentor Kip Ludwig
Abstract:
High density neurostimulation systems are coming to market to help spinal cord injury patients by stimulating and recording neuromuscular function. However, the parameter space that these systems have to explore is exceedingly large, and would need an artificial intelligence (AI) system to optimize. We need a platform that will allow us to determine the optimal parameter space for these systems. O…
▽ More
High density neurostimulation systems are coming to market to help spinal cord injury patients by stimulating and recording neuromuscular function. However, the parameter space that these systems have to explore is exceedingly large, and would need an artificial intelligence (AI) system to optimize. We need a platform that will allow us to determine the optimal parameter space for these systems. Our project aims to build a platform for map** and controlling neuromuscular activity, as a high-throughput testbed for implementing and testing closed-loop neuromuscular activity. This abstract presents the first phase (the map** phase) of building that testbed by combining multi-electrode stimulation/recording with visual motion-tracking. A 3D-printed rectangular raceway was used with 4 pairs of differential recording electrodes, and two stimulation electrodes embedded in the raceway bed. Non-anesthetized earthworms were placed on the raceway with their head section on the stimulating electrodes. Bipolar sinusoidal stimulation pulses of a range of voltages (2 to 6Vp-p), pulse durations (2 ms to 6.7 ms), and a burst rate of 1 pulse per second were applied, and action potentials and physical motion were recorded and analyzed. Action potentials were found to correlate with expansion/contraction displacements of worm segments, and voltage increases were shown to increase action potential propagation amplitude. Using the multiple electrode recording allowed us to capture the wave propagation of action potential pulse over the length of the worm. Feasibility of a platform to simultaneously monitor action potentials and motion of earthworms with real-time map** was demonstrated.
△ Less
Submitted 2 December, 2021;
originally announced December 2021.