SiamQuality: A ConvNet-Based Foundation Model for Imperfect Physiological Signals
Authors:
Cheng Ding,
Zhicheng Guo,
Zhaoliang Chen,
Randall J Lee,
Cynthia Rudin,
Xiao Hu
Abstract:
Foundation models, especially those using transformers as backbones, have gained significant popularity, particularly in language and language-vision tasks. However, large foundation models are typically trained on high-quality data, which poses a significant challenge, given the prevalence of poor-quality real-world data. This challenge is more pronounced for develo** foundation models for phys…
▽ More
Foundation models, especially those using transformers as backbones, have gained significant popularity, particularly in language and language-vision tasks. However, large foundation models are typically trained on high-quality data, which poses a significant challenge, given the prevalence of poor-quality real-world data. This challenge is more pronounced for develo** foundation models for physiological data; such data are often noisy, incomplete, or inconsistent. The present work aims to provide a toolset for develo** foundation models on physiological data. We leverage a large dataset of photoplethysmography (PPG) signals from hospitalized intensive care patients. For this data, we propose SimQuality, a novel self-supervised learning task based on convolutional neural networks (CNNs) as the backbone to enforce representations to be similar for good and poor quality signals that are from similar physiological states. We pre-trained the SimQuality on over 36 million 30-second PPG pairs and then fine-tuned and tested on six downstream tasks using external datasets. The results demonstrate the superiority of the proposed approach on all the downstream tasks, which are extremely important for heart monitoring on wearable devices. Our method indicates that CNNs can be an effective backbone for foundation models that are robust to training data quality.
△ Less
Submitted 26 April, 2024;
originally announced April 2024.
-
SQUWA: Signal Quality Aware DNN Architecture for Enhanced Accuracy in Atrial Fibrillation Detection from Noisy PPG Signals
Authors:
Runze Yan,
Cheng Ding,
Ran Xiao,
Aleksandr Fedorov,
Randall J Lee,
Fadi Nahab,
Xiao Hu
Abstract:
Atrial fibrillation (AF), a common cardiac arrhythmia, significantly increases the risk of stroke, heart disease, and mortality. Photoplethysmography (PPG) offers a promising solution for continuous AF monitoring, due to its cost efficiency and integration into wearable devices. Nonetheless, PPG signals are susceptible to corruption from motion artifacts and other factors often encountered in ambu…
▽ More
Atrial fibrillation (AF), a common cardiac arrhythmia, significantly increases the risk of stroke, heart disease, and mortality. Photoplethysmography (PPG) offers a promising solution for continuous AF monitoring, due to its cost efficiency and integration into wearable devices. Nonetheless, PPG signals are susceptible to corruption from motion artifacts and other factors often encountered in ambulatory settings. Conventional approaches typically discard corrupted segments or attempt to reconstruct original signals, allowing for the use of standard machine learning techniques. However, this reduces dataset size and introduces biases, compromising prediction accuracy and the effectiveness of continuous monitoring. We propose a novel deep learning model, Signal Quality Weighted Fusion of Attentional Convolution and Recurrent Neural Network (SQUWA), designed to learn how to retain accurate predictions from partially corrupted PPG. Specifically, SQUWA innovatively integrates an attention mechanism that directly considers signal quality during the learning process, dynamically adjusting the weights of time series segments based on their quality. This approach enhances the influence of higher-quality segments while reducing that of lower-quality ones, effectively utilizing partially corrupted segments. This approach represents a departure from the conventional methods that exclude such segments, enabling the utilization of a broader range of data, which has great implications for less disruption when monitoring of AF risks and more accurate estimation of AF burdens. Our extensive experiments show that SQUWA outperform existing PPG-based models, achieving the highest AUCPR of 0.89 with label noise mitigation. This also exceeds the 0.86 AUCPR of models trained with using both electrocardiogram (ECG) and PPG data.
△ Less
Submitted 14 April, 2024;
originally announced April 2024.
-
Learning From Alarms: A Robust Learning Approach for Accurate Photoplethysmography-Based Atrial Fibrillation Detection using Eight Million Samples Labeled with Imprecise Arrhythmia Alarms
Authors:
Cheng Ding,
Zhicheng Guo,
Cynthia Rudin,
Ran Xiao,
Amit Shah,
Duc H. Do,
Randall J Lee,
Gari Clifford,
Fadi B Nahab,
Xiao Hu
Abstract:
Atrial fibrillation (AF) is a common cardiac arrhythmia with serious health consequences if not detected and treated early. Detecting AF using wearable devices with photoplethysmography (PPG) sensors and deep neural networks has demonstrated some success using proprietary algorithms in commercial solutions. However, further advancement of this paradigm of continuous AF detection in ambulatory sett…
▽ More
Atrial fibrillation (AF) is a common cardiac arrhythmia with serious health consequences if not detected and treated early. Detecting AF using wearable devices with photoplethysmography (PPG) sensors and deep neural networks has demonstrated some success using proprietary algorithms in commercial solutions. However, further advancement of this paradigm of continuous AF detection in ambulatory settings, towards a population-wide screening use case, still faces several challenges, one of which is the lack of large-scale labeled training data. To address this challenge, in this study, we propose to leverage AF alarms from bedside patient monitors to label concurrent PPG signals, resulting in the largest PPG-AF dataset so far (8.5M 30-second records from 24100 patients) and demonstrating a practical approach to build large labeled PPG datasets. Furthermore, we recognize that the AF labels thus obtained contain errors because of false AF alarms generated from imperfect built-in algorithms from bedside monitors. Dealing with label noise with unknown distribution characteristics in this case requires advanced algorithms. We, therefore, introduce and open source a novel loss design, the cluster membership consistency (CMC) loss, to mitigate label errors. By comparing CMC with state-of-the-art methods selected from a noisy label competition, we demonstrate its superiority in multiple aspects including handling label noise in PPG data, resilience to poor-quality signals, and computational efficiency.
△ Less
Submitted 12 November, 2023; v1 submitted 7 November, 2022;
originally announced November 2022.
-
Log-Spectral Matching GAN: PPG-based Atrial Fibrillation Detection can be Enhanced by GAN-based Data Augmentation with Integration of Spectral Loss
Authors:
Cheng Ding,
Ran Xiao,
Duc Do,
David Scott Lee,
Shadi Kalantarian,
Randall J Lee,
Xiao Hu
Abstract:
Photoplethysmography (PPG) is a ubiquitous physiological measurement that detects beat-to-beat pulsatile blood volume changes and hence has a potential for monitoring cardiovascular conditions, particularly in ambulatory settings. A PPG dataset that is created for a particular use case is often imbalanced, due to a low prevalence of the pathological condition it targets to predict and the paroxysm…
▽ More
Photoplethysmography (PPG) is a ubiquitous physiological measurement that detects beat-to-beat pulsatile blood volume changes and hence has a potential for monitoring cardiovascular conditions, particularly in ambulatory settings. A PPG dataset that is created for a particular use case is often imbalanced, due to a low prevalence of the pathological condition it targets to predict and the paroxysmal nature of the condition as well. To tackle this problem, we propose log-spectral matching GAN (LSM-GAN), a generative model that can be used as a data augmentation technique to alleviate the class imbalance in a PPG dataset to train a classifier. LSM-GAN utilizes a novel generator that generates a synthetic signal without a up-sampling process of input white noises, as well as adds the mismatch between real and synthetic signals in frequency domain to the conventional adversarial loss. In this study, experiments are designed focusing on examining how the influence of LSM-GAN as a data augmentation technique on one specific classification task - atrial fibrillation (AF) detection using PPG. We show that by taking spectral information into consideration, LSM-GAN as a data augmentation solution can generate more realistic PPG signals. The code of LSM-GAN is available at https://github.com/chengding0713/Log-Spectral-matching-GAN.
△ Less
Submitted 31 January, 2022; v1 submitted 11 August, 2021;
originally announced August 2021.